Kristina Klier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kristina Klier has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Annette Schmidt
Institute of Sports Science, University of the Bundeswehr Munich, 85579 Neubiberg, Germany
5 shared publications - Timo Schinköthe
CANKADO GmbH, Ottobrunn, Germany
4 shared publications Kirstin Seiler
Institute of Sports Science, Department of Human Sciences, Universität der Bundeswehr München, Germany
2 shared publications- Lisa Graf
Institute of Sport Science, University of the Bundeswehr Munich, Neubiberg, Germany
2 shared publications - Lucas Koch
Sports Biology, University of the Bundeswehr Munich, 85579 Neubiberg, Germany
2 shared publications Matthias Wagner
Institute of Sports Science, Department of Human Sciences, Universität der Bundeswehr München, Germany
2 shared publications
Latest Publications
- Open Access
- 14 January 2026
- Published by Springer Nature in BMC Public Health
- Vol. 26 (1)
From factory floors to dream doors: a systematic review of sleep interventions in industrial workers
Background: In shift work, where sleeping and working is contrary to the usual circadian rhythm, poor sleep is often associated with observed higher risk for worse functioning, health, and well-being. Sleep-enhancing targeted promotion could be a promising work place health intervention to counteract these risk factors. The objective of this study was to systematically review to what extent and with what efficacy sleep interventions are already being used in shift work settings. Methods: We searched five databases (PubMed, Cochrane Library, Web of Science, Scopus, and EBSCO, until June 18th, 2024) for any controlled intervention study on shift workers adopting any sleep-enhancing interventions with any control/comparator and any outcome in the context of health, work ability, or sleep. The risk of bias tool II (for RCTs) and, for the non-randomized studies, the ROBINS-I-tool were used for risk of bias ratings. Results: The search yielded 11,261 studies after duplicate removal. Six studies (3 randomized controlled studies (RCTs), 3 non-randomized interventions, 518 participants) could finally be included in this review. Three studies adopted behavioral interventions (cognitive behavioral therapy), one used a pharmacological treatment (melatonin), and two applied an environmental approach (light exposure). Some concerns for an overall risk of bias were given in the RCTs, whilst the non-randomized controlled studies were judged to have a serious overall risk of bias. The efficacy of the interventions was mixed with beneficial and non-beneficial effects regarding the sleep parameters observed. Conclusions: In terms of optimizing industrial workers’ health, well-being and productivity, sleep interventions seem promising. Such interventions can be offered on a low-threshold without interfering everyday (working) life. Future research is needed not only to further prove the efficacy of such interventions, but also to derive practical implications and recommendations for suitable interventions. Trial registration: This systematic review was pre-registered in PROSPERO (CRD42024559360).
- 14 January 2026
- Published by Springer Nature in BMC Public Health
- Vol. 26 (1)
Open AccessFrom factory floors to dream doors: a systematic review of sleep interventions in industrial workers
Background: In shift work, where sleeping and working is contrary to the usual circadian rhythm, poor sleep is often associated with observed higher risk for worse functioning, health, and well-being. Sleep-enhancing targeted promotion could be a promising work place health intervention to counteract these risk factors. The objective of this study was to systematically review to what extent and with what efficacy sleep interventions are already being used in shift work settings. Methods: We searched five databases (PubMed, Cochrane Library, Web of Science, Scopus, and EBSCO, until June 18th, 2024) for any controlled intervention study on shift workers adopting any sleep-enhancing interventions with any control/comparator and any outcome in the context of health, work ability, or sleep. The risk of bias tool II (for RCTs) and, for the non-randomized studies, the ROBINS-I-tool were used for risk of bias ratings. Results: The search yielded 11,261 studies after duplicate removal. Six studies (3 randomized controlled studies (RCTs), 3 non-randomized interventions, 518 participants) could finally be included in this review. Three studies adopted behavioral interventions (cognitive behavioral therapy), one used a pharmacological treatment (melatonin), and two applied an environmental approach (light exposure). Some concerns for an overall risk of bias were given in the RCTs, whilst the non-randomized controlled studies were judged to have a serious overall risk of bias. The efficacy of the interventions was mixed with beneficial and non-beneficial effects regarding the sleep parameters observed. Conclusions: In terms of optimizing industrial workers’ health, well-being and productivity, sleep interventions seem promising. Such interventions can be offered on a low-threshold without interfering everyday (working) life. Future research is needed not only to further prove the efficacy of such interventions, but also to derive practical implications and recommendations for suitable interventions. Trial registration: This systematic review was pre-registered in PROSPERO (CRD42024559360).
- Open Access
- 11 October 2024
- Published by Elsevier in Physiology & Behavior
- Vol. 287, 114714
Does gaming keep subjects awake?: Subjective and objective sleep parameters following gaming in comparison to a passive control
- 11 October 2024
- Published by Elsevier in Physiology & Behavior
- Vol. 287, 114714
Open AccessDoes gaming keep subjects awake?: Subjective and objective sleep parameters following gaming in comparison to a passive control
- Open Access
- 27 January 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-11
Physical activity and nutrition in relation to resilience: a cross-sectional study
A healthy lifestyle is often discussed as being a characteristic of or a prerequisite for quality of life. In phases of high subjective stress (work overload, negative thoughts), however, its protective function can be limited. The two present survey studies examined two facets of a health-related lifestyle (physical activity and nutritional awareness), in particular, the correlations with general life satisfaction and their adaptive function in respect to stress (resilience). In addition, because episodes of increased stress can have a negative effect on eating, the interactions with the consumption of less healthy food were examined. Two cross-sectional studies were conducted successively with adults aged between 18 and 72 in Germany. Study 1 (N = 685) examined the research questions with correlations, moderated regression analyses, and structural equation models. Study 2 (N = 628) differentiated between sport, occupational and daily activities. Study 1 showed that the amount of physical activity and nutritional awareness are correlated with life satisfaction. The relationship between stress appraisals and general life satisfaction was moderated by physical activity and nutritional awareness (stress-buffer effect). Study 2 replicated the stress-buffer effects of nutritional awareness, daily activities, and occupational activities. Both studies showed that stress is associated with consumption of less healthy food and found interactions with physical activity and nutritional awareness. Discussed are the adaptive role of physical activity and nutritional awareness in times of stress.Trial Registration EK UniBw M 23-06, 12/16/2022.
- 27 January 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-11
Open AccessPhysical activity and nutrition in relation to resilience: a cross-sectional study
A healthy lifestyle is often discussed as being a characteristic of or a prerequisite for quality of life. In phases of high subjective stress (work overload, negative thoughts), however, its protective function can be limited. The two present survey studies examined two facets of a health-related lifestyle (physical activity and nutritional awareness), in particular, the correlations with general life satisfaction and their adaptive function in respect to stress (resilience). In addition, because episodes of increased stress can have a negative effect on eating, the interactions with the consumption of less healthy food were examined. Two cross-sectional studies were conducted successively with adults aged between 18 and 72 in Germany. Study 1 (N = 685) examined the research questions with correlations, moderated regression analyses, and structural equation models. Study 2 (N = 628) differentiated between sport, occupational and daily activities. Study 1 showed that the amount of physical activity and nutritional awareness are correlated with life satisfaction. The relationship between stress appraisals and general life satisfaction was moderated by physical activity and nutritional awareness (stress-buffer effect). Study 2 replicated the stress-buffer effects of nutritional awareness, daily activities, and occupational activities. Both studies showed that stress is associated with consumption of less healthy food and found interactions with physical activity and nutritional awareness. Discussed are the adaptive role of physical activity and nutritional awareness in times of stress.Trial Registration EK UniBw M 23-06, 12/16/2022.
- Open Access
- 23 November 2023
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 7 (1) , e50701
Diagnostic Accuracy of Single-Lead Electrocardiograms Using the Kardia Mobile App and the Apple Watch 4: Validation Study
Background: To date, the 12-lead electrocardiogram (ECG) is the gold standard for cardiological diagnosis in clinical settings. With the advancements in technology, a growing number of smartphone apps and gadgets for recording, visualizing, and evaluating physical performance as well as health data is available. Although this new smart technology is innovative and time- and cost-efficient, less is known about its diagnostic accuracy and reliability. Objective: This study aimed to examine the agreement between the mobile single-lead ECG measurements of the Kardia Mobile App and the Apple Watch 4 compared to the 12-lead gold standard ECG in healthy adults under laboratory conditions. Furthermore, it assessed whether the measurement error of the devices increases with an increasing heart rate. Methods: This study was designed as a prospective quasi-experimental 1-sample measurement, in which no randomization of the sampling was carried out. In total, ECGs at rest from 81 participants (average age 24.89, SD 8.58 years; n=58, 72% male) were recorded and statistically analyzed. Bland-Altman plots were created to graphically illustrate measurement differences. To analyze the agreement between the single-lead ECGs and the 12-lead ECG, Pearson correlation coefficient (r) and Lin concordance correlation coefficient (CCCLin) were calculated. Results: The results showed a higher agreement for the Apple Watch (mean deviation QT: 6.85%; QT interval corrected for heart rate using Fridericia formula [QTcF]: 7.43%) than Kardia Mobile (mean deviation QT: 9.53%; QTcF: 9.78%) even if both tend to underestimate QT and QTcF intervals. For Kardia Mobile, the QT and QTcF intervals correlated significantly with the gold standard (rQT=0.857 and rQTcF=0.727; P<.001). CCCLin corresponded to an almost complete heuristic agreement for the QT interval (0.835), whereas the QTcF interval was in the range of strong agreement (0.682). Further, for the Apple Watch, Pearson correlations were highly significant and in the range of a large effect (rQT=0.793 and rQTcF=0.649; P<.001). CCCLin corresponded to a strong heuristic agreement for both the QT (0.779) and QTcF (0.615) intervals. A small negative correlation between the measurement error and increasing heart rate could be found of each the devices and the reference. Conclusions: Smart technology seems to be a promising and reliable approach for nonclinical health monitoring. Further research is needed to broaden the evidence regarding its validity and usability in different target groups.
- 23 November 2023
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 7 (1) , e50701
Open AccessDiagnostic Accuracy of Single-Lead Electrocardiograms Using the Kardia Mobile App and the Apple Watch 4: Validation Study
Background: To date, the 12-lead electrocardiogram (ECG) is the gold standard for cardiological diagnosis in clinical settings. With the advancements in technology, a growing number of smartphone apps and gadgets for recording, visualizing, and evaluating physical performance as well as health data is available. Although this new smart technology is innovative and time- and cost-efficient, less is known about its diagnostic accuracy and reliability. Objective: This study aimed to examine the agreement between the mobile single-lead ECG measurements of the Kardia Mobile App and the Apple Watch 4 compared to the 12-lead gold standard ECG in healthy adults under laboratory conditions. Furthermore, it assessed whether the measurement error of the devices increases with an increasing heart rate. Methods: This study was designed as a prospective quasi-experimental 1-sample measurement, in which no randomization of the sampling was carried out. In total, ECGs at rest from 81 participants (average age 24.89, SD 8.58 years; n=58, 72% male) were recorded and statistically analyzed. Bland-Altman plots were created to graphically illustrate measurement differences. To analyze the agreement between the single-lead ECGs and the 12-lead ECG, Pearson correlation coefficient (r) and Lin concordance correlation coefficient (CCCLin) were calculated. Results: The results showed a higher agreement for the Apple Watch (mean deviation QT: 6.85%; QT interval corrected for heart rate using Fridericia formula [QTcF]: 7.43%) than Kardia Mobile (mean deviation QT: 9.53%; QTcF: 9.78%) even if both tend to underestimate QT and QTcF intervals. For Kardia Mobile, the QT and QTcF intervals correlated significantly with the gold standard (rQT=0.857 and rQTcF=0.727; P<.001). CCCLin corresponded to an almost complete heuristic agreement for the QT interval (0.835), whereas the QTcF interval was in the range of strong agreement (0.682). Further, for the Apple Watch, Pearson correlations were highly significant and in the range of a large effect (rQT=0.793 and rQTcF=0.649; P<.001). CCCLin corresponded to a strong heuristic agreement for both the QT (0.779) and QTcF (0.615) intervals. A small negative correlation between the measurement error and increasing heart rate could be found of each the devices and the reference. Conclusions: Smart technology seems to be a promising and reliable approach for nonclinical health monitoring. Further research is needed to broaden the evidence regarding its validity and usability in different target groups.
- Open Access
- 11 September 2023
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 7 (1) , e48096
Corrected QT Interval (QTc) Diagnostic App for the Oncological Routine: Development Study
Background: Numerous antineoplastic drugs such as chemotherapeutics have cardiotoxic side effects and can lead to long QT syndrome (LQTS). When diagnosed and treated in time, the potentially fatal outcomes of LQTS can be prevented. Therefore, regular electrocardiogram (ECG) assessments are critical to ensure patient safety. However, these assessments are associated with patient discomfort and require timely support of the attending oncologist by a cardiologist. Objective: This study aimed to examine whether this approach can be made more efficient and comfortable by a smartphone app (QTc Tracker), supporting single-lead ECG records on site and transferring to a tele-cardiologist for an immediate diagnosis. Methods: To evaluate the QTc Tracker, it was implemented in 54 cancer centers in Germany. In total, 266 corrected QT interval (QTc) diagnoses of 122 patients were recorded. Moreover, a questionnaire on routine ECG workflow, turnaround time, and satisfaction (1=best, 6=worst) was answered by the centers before and after the implementation of the QTc Tracker. Results: Compared to the routine ECG workflow, the QTc Tracker enabled a substantial turnaround time reduction of 98% (mean 2.67, 95% CI 1.72-2.67 h) and even further time efficiency in combination with a cardiologic on-call service (mean 12.10, 95% CI 5.67-18.67 min). Additionally, nurses and patients reported higher satisfaction when using the QTc Tracker. In particular, patients’ satisfaction sharply improved from 2.59 (95% CI 2.41-2.88) for the routine ECG workflow to 1.25 (95% CI 0.99-1.51) for the QTc Tracker workflow. Conclusions: These results reveal a significant improvement regarding reduced turnaround time and increased user satisfaction. Best patient care might be guaranteed as the exposure of patients with an uncontrolled risk of QTc prolongations can be avoided by using the fast and easy QTc Tracker. In particular, as regular side-effect monitoring, the QTc Tracker app promises more convenience for patients and their physicians. Finally, future studies are needed to empirically test the usability and validity of such mobile ECG assessment methods. Trial Registration: ClinicalTrials.gov NCT04055493; https://classic.clinicaltrials.gov/ct2/show/NCT04055493
- 11 September 2023
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 7 (1) , e48096
Open AccessCorrected QT Interval (QTc) Diagnostic App for the Oncological Routine: Development Study
Background: Numerous antineoplastic drugs such as chemotherapeutics have cardiotoxic side effects and can lead to long QT syndrome (LQTS). When diagnosed and treated in time, the potentially fatal outcomes of LQTS can be prevented. Therefore, regular electrocardiogram (ECG) assessments are critical to ensure patient safety. However, these assessments are associated with patient discomfort and require timely support of the attending oncologist by a cardiologist. Objective: This study aimed to examine whether this approach can be made more efficient and comfortable by a smartphone app (QTc Tracker), supporting single-lead ECG records on site and transferring to a tele-cardiologist for an immediate diagnosis. Methods: To evaluate the QTc Tracker, it was implemented in 54 cancer centers in Germany. In total, 266 corrected QT interval (QTc) diagnoses of 122 patients were recorded. Moreover, a questionnaire on routine ECG workflow, turnaround time, and satisfaction (1=best, 6=worst) was answered by the centers before and after the implementation of the QTc Tracker. Results: Compared to the routine ECG workflow, the QTc Tracker enabled a substantial turnaround time reduction of 98% (mean 2.67, 95% CI 1.72-2.67 h) and even further time efficiency in combination with a cardiologic on-call service (mean 12.10, 95% CI 5.67-18.67 min). Additionally, nurses and patients reported higher satisfaction when using the QTc Tracker. In particular, patients’ satisfaction sharply improved from 2.59 (95% CI 2.41-2.88) for the routine ECG workflow to 1.25 (95% CI 0.99-1.51) for the QTc Tracker workflow. Conclusions: These results reveal a significant improvement regarding reduced turnaround time and increased user satisfaction. Best patient care might be guaranteed as the exposure of patients with an uncontrolled risk of QTc prolongations can be avoided by using the fast and easy QTc Tracker. In particular, as regular side-effect monitoring, the QTc Tracker app promises more convenience for patients and their physicians. Finally, future studies are needed to empirically test the usability and validity of such mobile ECG assessment methods. Trial Registration: ClinicalTrials.gov NCT04055493; https://classic.clinicaltrials.gov/ct2/show/NCT04055493
- Open Access
- 10 July 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Diagnostic Accuracy of Single-Lead Electrocardiograms Using the Kardia Mobile App and the Apple Watch 4: Validation Study (Preprint)
BACKGROUND To date, the 12-lead electrocardiogram (ECG) is the gold standard for cardiological diagnosis in clinical settings. With the advancements in technology, a growing number of smartphone apps and gadgets for recording, visualizing, and evaluating physical performance as well as health data is available. Although this new smart technology is innovative and time- and cost-efficient, less is known about its diagnostic accuracy and reliability. OBJECTIVE This study aimed to examine the agreement between the mobile single-lead ECG measurements of the Kardia Mobile App and the Apple Watch 4 compared to the 12-lead gold standard ECG in healthy adults under laboratory conditions. Furthermore, it assessed whether the measurement error of the devices increases with an increasing heart rate. METHODS This study was designed as a prospective quasi-experimental 1-sample measurement, in which no randomization of the sampling was carried out. In total, ECGs at rest from 81 participants (average age 24.89, SD 8.58 years; n=58, 72% male) were recorded and statistically analyzed. Bland-Altman plots were created to graphically illustrate measurement differences. To analyze the agreement between the single-lead ECGs and the 12-lead ECG, Pearson correlation coefficient (r) and Lin concordance correlation coefficient (CCCLin) were calculated. RESULTS The results showed a higher agreement for the Apple Watch (mean deviation QT: 6.85%; QT interval corrected for heart rate using Fridericia formula [QTcF]: 7.43%) than Kardia Mobile (mean deviation QT: 9.53%; QTcF: 9.78%) even if both tend to underestimate QT and QTcF intervals. For Kardia Mobile, the QT and QTcF intervals correlated significantly with the gold standard (rQT=0.857 and rQTcF=0.727; P<.001). CCCLin corresponded to an almost complete heuristic agreement for the QT interval (0.835), whereas the QTcF interval was in the range of strong agreement (0.682). Further, for the Apple Watch, Pearson correlations were highly significant and in the range of a large effect (rQT=0.793 and rQTcF=0.649; P<.001). CCCLin corresponded to a strong heuristic agreement for both the QT (0.779) and QTcF (0.615) intervals. A small negative correlation between the measurement error and increasing heart rate could be found of each the devices and the reference. CONCLUSIONS Smart technology seems to be a promising and reliable approach for nonclinical health monitoring. Further research is needed to broaden the evidence regarding its validity and usability in different target groups.
- 10 July 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessDiagnostic Accuracy of Single-Lead Electrocardiograms Using the Kardia Mobile App and the Apple Watch 4: Validation Study (Preprint)
BACKGROUND To date, the 12-lead electrocardiogram (ECG) is the gold standard for cardiological diagnosis in clinical settings. With the advancements in technology, a growing number of smartphone apps and gadgets for recording, visualizing, and evaluating physical performance as well as health data is available. Although this new smart technology is innovative and time- and cost-efficient, less is known about its diagnostic accuracy and reliability. OBJECTIVE This study aimed to examine the agreement between the mobile single-lead ECG measurements of the Kardia Mobile App and the Apple Watch 4 compared to the 12-lead gold standard ECG in healthy adults under laboratory conditions. Furthermore, it assessed whether the measurement error of the devices increases with an increasing heart rate. METHODS This study was designed as a prospective quasi-experimental 1-sample measurement, in which no randomization of the sampling was carried out. In total, ECGs at rest from 81 participants (average age 24.89, SD 8.58 years; n=58, 72% male) were recorded and statistically analyzed. Bland-Altman plots were created to graphically illustrate measurement differences. To analyze the agreement between the single-lead ECGs and the 12-lead ECG, Pearson correlation coefficient (r) and Lin concordance correlation coefficient (CCCLin) were calculated. RESULTS The results showed a higher agreement for the Apple Watch (mean deviation QT: 6.85%; QT interval corrected for heart rate using Fridericia formula [QTcF]: 7.43%) than Kardia Mobile (mean deviation QT: 9.53%; QTcF: 9.78%) even if both tend to underestimate QT and QTcF intervals. For Kardia Mobile, the QT and QTcF intervals correlated significantly with the gold standard (rQT=0.857 and rQTcF=0.727; P<.001). CCCLin corresponded to an almost complete heuristic agreement for the QT interval (0.835), whereas the QTcF interval was in the range of strong agreement (0.682). Further, for the Apple Watch, Pearson correlations were highly significant and in the range of a large effect (rQT=0.793 and rQTcF=0.649; P<.001). CCCLin corresponded to a strong heuristic agreement for both the QT (0.779) and QTcF (0.615) intervals. A small negative correlation between the measurement error and increasing heart rate could be found of each the devices and the reference. CONCLUSIONS Smart technology seems to be a promising and reliable approach for nonclinical health monitoring. Further research is needed to broaden the evidence regarding its validity and usability in different target groups.
- Open Access
- 11 April 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Corrected QT Interval (QTc) Diagnostic App for the Oncological Routine: Development Study (Preprint)
BACKGROUND Numerous antineoplastic drugs such as chemotherapeutics have cardiotoxic side effects and can lead to long QT syndrome (LQTS). When diagnosed and treated in time, the potentially fatal outcomes of LQTS can be prevented. Therefore, regular electrocardiogram (ECG) assessments are critical to ensure patient safety. However, these assessments are associated with patient discomfort and require timely support of the attending oncologist by a cardiologist. OBJECTIVE This study aimed to examine whether this approach can be made more efficient and comfortable by a smartphone app (QTc Tracker), supporting single-lead ECG records on site and transferring to a tele-cardiologist for an immediate diagnosis. METHODS To evaluate the QTc Tracker, it was implemented in 54 cancer centers in Germany. In total, 266 corrected QT interval (QTc) diagnoses of 122 patients were recorded. Moreover, a questionnaire on routine ECG workflow, turnaround time, and satisfaction (1=best, 6=worst) was answered by the centers before and after the implementation of the QTc Tracker. RESULTS Compared to the routine ECG workflow, the QTc Tracker enabled a substantial turnaround time reduction of 98% (mean 2.67, 95% CI 1.72-2.67 h) and even further time efficiency in combination with a cardiologic on-call service (mean 12.10, 95% CI 5.67-18.67 min). Additionally, nurses and patients reported higher satisfaction when using the QTc Tracker. In particular, patients’ satisfaction sharply improved from 2.59 (95% CI 2.41-2.88) for the routine ECG workflow to 1.25 (95% CI 0.99-1.51) for the QTc Tracker workflow. CONCLUSIONS These results reveal a significant improvement regarding reduced turnaround time and increased user satisfaction. Best patient care might be guaranteed as the exposure of patients with an uncontrolled risk of QTc prolongations can be avoided by using the fast and easy QTc Tracker. In particular, as regular side-effect monitoring, the QTc Tracker app promises more convenience for patients and their physicians. Finally, future studies are needed to empirically test the usability and validity of such mobile ECG assessment methods. CLINICALTRIAL ClinicalTrials.gov NCT04055493; https://classic.clinicaltrials.gov/ct2/show/NCT04055493
- 11 April 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessCorrected QT Interval (QTc) Diagnostic App for the Oncological Routine: Development Study (Preprint)
BACKGROUND Numerous antineoplastic drugs such as chemotherapeutics have cardiotoxic side effects and can lead to long QT syndrome (LQTS). When diagnosed and treated in time, the potentially fatal outcomes of LQTS can be prevented. Therefore, regular electrocardiogram (ECG) assessments are critical to ensure patient safety. However, these assessments are associated with patient discomfort and require timely support of the attending oncologist by a cardiologist. OBJECTIVE This study aimed to examine whether this approach can be made more efficient and comfortable by a smartphone app (QTc Tracker), supporting single-lead ECG records on site and transferring to a tele-cardiologist for an immediate diagnosis. METHODS To evaluate the QTc Tracker, it was implemented in 54 cancer centers in Germany. In total, 266 corrected QT interval (QTc) diagnoses of 122 patients were recorded. Moreover, a questionnaire on routine ECG workflow, turnaround time, and satisfaction (1=best, 6=worst) was answered by the centers before and after the implementation of the QTc Tracker. RESULTS Compared to the routine ECG workflow, the QTc Tracker enabled a substantial turnaround time reduction of 98% (mean 2.67, 95% CI 1.72-2.67 h) and even further time efficiency in combination with a cardiologic on-call service (mean 12.10, 95% CI 5.67-18.67 min). Additionally, nurses and patients reported higher satisfaction when using the QTc Tracker. In particular, patients’ satisfaction sharply improved from 2.59 (95% CI 2.41-2.88) for the routine ECG workflow to 1.25 (95% CI 0.99-1.51) for the QTc Tracker workflow. CONCLUSIONS These results reveal a significant improvement regarding reduced turnaround time and increased user satisfaction. Best patient care might be guaranteed as the exposure of patients with an uncontrolled risk of QTc prolongations can be avoided by using the fast and easy QTc Tracker. In particular, as regular side-effect monitoring, the QTc Tracker app promises more convenience for patients and their physicians. Finally, future studies are needed to empirically test the usability and validity of such mobile ECG assessment methods. CLINICALTRIAL ClinicalTrials.gov NCT04055493; https://classic.clinicaltrials.gov/ct2/show/NCT04055493
- Open Access
- 27 December 2022
- Published by Springer Nature in BMC Psychology
- Vol. 10 (1) , 1-12
#fitspiration: a comparison of the sport-related social media usage and its impact on body image in young adults
Background: Following and posting sport-related content on social media is wide-spread among young people. To date, little is known about the interdependence between sport-related social media use and the thereby perceived personal body image. Methods: We conducted an online survey (N = 285) to examine how social media influences the sport-related body image. Results: In general, social media are frequently used for sport (n = 136, 47.7%). Resistance training correlated significantly with several motives of sport-related use of social media, and thus, represents the strong online presence of athletic sports. Less correlations could be found in team or other sports. Regarding the perception of body image, it was found that the group of rejecting (negative) body image significantly correlated with the emulation of social media mediated sport-related beauty and body ideals (r = 0.63, p = 0.001), as well as with increased body dissatisfaction when viewing sport-related posts on social media (r = 0.590, p = 0.001). Perceived social pressure and comparison were found to be mediators of the prevailing influence of social media usage. Conclusions: These results reveal the importance of taking a closer look at socially shaped beauty and body ideals, especially in sport-related contents, striving for more educational campaigns such as Body Positivity and, above all, filtering information. Finally, future research is needed to gain deeper insight into young persons’ usage behavior of social media and its impact on the individual’s body image. Trial Registration The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Ethics Committee of University of the Federal Armed Forces Munich, Germany (01/24/2022).
- 27 December 2022
- Published by Springer Nature in BMC Psychology
- Vol. 10 (1) , 1-12
Open Access#fitspiration: a comparison of the sport-related social media usage and its impact on body image in young adults
Background: Following and posting sport-related content on social media is wide-spread among young people. To date, little is known about the interdependence between sport-related social media use and the thereby perceived personal body image. Methods: We conducted an online survey (N = 285) to examine how social media influences the sport-related body image. Results: In general, social media are frequently used for sport (n = 136, 47.7%). Resistance training correlated significantly with several motives of sport-related use of social media, and thus, represents the strong online presence of athletic sports. Less correlations could be found in team or other sports. Regarding the perception of body image, it was found that the group of rejecting (negative) body image significantly correlated with the emulation of social media mediated sport-related beauty and body ideals (r = 0.63, p = 0.001), as well as with increased body dissatisfaction when viewing sport-related posts on social media (r = 0.590, p = 0.001). Perceived social pressure and comparison were found to be mediators of the prevailing influence of social media usage. Conclusions: These results reveal the importance of taking a closer look at socially shaped beauty and body ideals, especially in sport-related contents, striving for more educational campaigns such as Body Positivity and, above all, filtering information. Finally, future research is needed to gain deeper insight into young persons’ usage behavior of social media and its impact on the individual’s body image. Trial Registration The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Ethics Committee of University of the Federal Armed Forces Munich, Germany (01/24/2022).
- Open Access
Agreement of Sleep Measures—A Comparison between a Sleep Diary and Three Consumer Wearable Devices
Nowadays, self-tracking and optimization are widely spread. As sleep is essential for well-being, health, and peak performance, the number of available consumer technologies to assess individual sleep behavior is increasing rapidly. However, little is known about the consumer wearables’ usability and reliability for sleep tracking. Therefore, the aim of the present study was to compare the sleep measures of wearable devices with a standardized sleep diary in young healthy adults in free-living conditions. We tracked night sleep from 30 participants (19 females, 11 males; 24.3 ± 4.2 years old). Each wore three wearables and simultaneously assessed individual sleep patterns for four consecutive nights. Wearables and diaries correlated substantially regarding time in bed (Range CCCLin: 0.74–0.84) and total sleep time (Range CCCLin: 0.76–0.85). There was no sufficient agreement regarding the measures of sleep efficiency (Range CCCLin: 0.05–0.34) and sleep interruptions (Range CCCLin: −0.02–0.10). Finally, these results show wearables to be an easy-to-handle, time- and cost-efficient alternative to tracking sleep in healthy populations. Future research should develop and empirically test the usability of such consumer sleep technologies.
Open AccessAgreement of Sleep Measures—A Comparison between a Sleep Diary and Three Consumer Wearable Devices
Nowadays, self-tracking and optimization are widely spread. As sleep is essential for well-being, health, and peak performance, the number of available consumer technologies to assess individual sleep behavior is increasing rapidly. However, little is known about the consumer wearables’ usability and reliability for sleep tracking. Therefore, the aim of the present study was to compare the sleep measures of wearable devices with a standardized sleep diary in young healthy adults in free-living conditions. We tracked night sleep from 30 participants (19 females, 11 males; 24.3 ± 4.2 years old). Each wore three wearables and simultaneously assessed individual sleep patterns for four consecutive nights. Wearables and diaries correlated substantially regarding time in bed (Range CCCLin: 0.74–0.84) and total sleep time (Range CCCLin: 0.76–0.85). There was no sufficient agreement regarding the measures of sleep efficiency (Range CCCLin: 0.05–0.34) and sleep interruptions (Range CCCLin: −0.02–0.10). Finally, these results show wearables to be an easy-to-handle, time- and cost-efficient alternative to tracking sleep in healthy populations. Future research should develop and empirically test the usability of such consumer sleep technologies.
- Open Access
- 1 April 2022
- Published by Hogrefe Publishing Group in Zeitschrift für Sportpsychologie
- Vol. 29 (2-3) , 95-103
Influence of esports on Sleep and Stress
Recreative sleep and a low stress level are important health- and performance-enhancing factors in daily life. The present investigation examines the influence of esports on sleep and stress. In a counterbalanced within-subjects design, 44 participants (37 males, 7 females, 25.2 ± 4.6 years old) completed both a gaming and a nongaming session on two consecutive evenings. We assessed individual sleep duration and individual stress parameters via a Garmin® smartwatch in addition to a short subjective scale. The results show that, in the gaming condition, total sleep time was significantly lower than in the nongaming condition ( p = .003). The participants’ stress level was significantly increased after gaming compared to nongaming ( p = .005). Future research should not only examine the long-term effects of esports on health longitudinally, but also establish suitable sleep interventions and stress coping strategies.
- 1 April 2022
- Published by Hogrefe Publishing Group in Zeitschrift für Sportpsychologie
- Vol. 29 (2-3) , 95-103
Open AccessInfluence of esports on Sleep and Stress
Recreative sleep and a low stress level are important health- and performance-enhancing factors in daily life. The present investigation examines the influence of esports on sleep and stress. In a counterbalanced within-subjects design, 44 participants (37 males, 7 females, 25.2 ± 4.6 years old) completed both a gaming and a nongaming session on two consecutive evenings. We assessed individual sleep duration and individual stress parameters via a Garmin® smartwatch in addition to a short subjective scale. The results show that, in the gaming condition, total sleep time was significantly lower than in the nongaming condition ( p = .003). The participants’ stress level was significantly increased after gaming compared to nongaming ( p = .005). Future research should not only examine the long-term effects of esports on health longitudinally, but also establish suitable sleep interventions and stress coping strategies.