Wanting Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wanting Yu has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Brad Manor
Hinda and Arthur Marcus Institute for Aging Research, Hebrew SeniorLife , Boston, Massachusetts
7 shared publications - Junhong Zhou
The Hinda and Arthur Marcus Institute for Aging Research, Hebrew SeniorLife, Boston, MA 02131, USA; Harvard Medical School, Boston, MA 02131, USA
7 shared publications - On-Yee Lo
Hinda and Arthur Marcus Institute for Aging Research, Hebrew SeniorLife , Boston, Massachusetts
5 shared publications - Pei-An Lee
Hinda and Arthur Marcus Institute for Aging Research, Hebrew SeniorLife, Boston, MA, United States
3 shared publications - Thomas G. Travison
Harvard Medical School Boston Massachusetts USA
3 shared publications - Alvaro Pascual-Leone
Department of Neurology, Harvard Medical School, Boston, MA, United States
2 shared publications
Latest Publications
- Open Access
- 13 August 2024
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 12 (1) , e52166
A Novel Approach for Improving Gait Speed Estimation Using a Single Inertial Measurement Unit Embedded in a Smartphone: Validity and Reliability Study
Background: Gait speed is a valuable biomarker for mobility and overall health assessment. Existing methods to measure gait speed require expensive equipment or personnel assistance, limiting their use in unsupervised, daily-life conditions. The availability of smartphones equipped with a single inertial measurement unit (IMU) presents a viable and convenient method for measuring gait speed outside of laboratory and clinical settings. Previous works have used the inverted pendulum model to estimate gait speed using a non–smartphone-based IMU attached to the trunk. However, it is unclear whether and how this approach can estimate gait speed using the IMU embedded in a smartphone while being carried in a pants pocket during walking, especially under various walking conditions. Objective: This study aimed to validate and test the reliability of a smartphone IMU–based gait speed measurement placed in the user’s front pants pocket in both healthy young and older adults while walking quietly (ie, normal walking) and walking while conducting a cognitive task (ie, dual-task walking). Methods: A custom-developed smartphone application (app) was used to record gait data from 12 young adults and 12 older adults during normal and dual-task walking. The validity and reliability of gait speed and step length estimations from the smartphone were compared with the gold standard GAITRite mat. A coefficient-based adjustment based upon a coefficient relative to the original estimation of step length was applied to improve the accuracy of gait speed estimation. The magnitude of error (ie, bias and limits of agreement) between the gait data from the smartphone and the GAITRite mat was calculated for each stride. The Passing-Bablok orthogonal regression model was used to provide agreement (ie, slopes and intercepts) between the smartphone and the GAITRite mat. Results: The gait speed measured by the smartphone was valid when compared to the GAITRite mat. The original limits of agreement were 0.50 m/s (an ideal value of 0 m/s), and the orthogonal regression analysis indicated a slope of 1.68 (an ideal value of 1) and an intercept of −0.70 (an ideal value of 0). After adjustment, the accuracy of the smartphone-derived gait speed estimation improved, with limits of agreement reduced to 0.34 m/s. The adjusted slope improved to 1.00, with an intercept of 0.03. The test-retest reliability of smartphone-derived gait speed was good to excellent within supervised laboratory settings and unsupervised home conditions. The adjustment coefficients were applicable to a wide range of step lengths and gait speeds. Conclusions: The inverted pendulum approach is a valid and reliable method for estimating gait speed from a smartphone IMU placed in the pockets of younger and older adults. Adjusting step length by a coefficient derived from the original estimation of step length successfully removed bias and improved the accuracy of gait speed estimation. This novel method has potential applications in various settings and populations, though fine-tuning may be necessary for specific data sets.
- 13 August 2024
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 12 (1) , e52166
Open AccessA Novel Approach for Improving Gait Speed Estimation Using a Single Inertial Measurement Unit Embedded in a Smartphone: Validity and Reliability Study
Background: Gait speed is a valuable biomarker for mobility and overall health assessment. Existing methods to measure gait speed require expensive equipment or personnel assistance, limiting their use in unsupervised, daily-life conditions. The availability of smartphones equipped with a single inertial measurement unit (IMU) presents a viable and convenient method for measuring gait speed outside of laboratory and clinical settings. Previous works have used the inverted pendulum model to estimate gait speed using a non–smartphone-based IMU attached to the trunk. However, it is unclear whether and how this approach can estimate gait speed using the IMU embedded in a smartphone while being carried in a pants pocket during walking, especially under various walking conditions. Objective: This study aimed to validate and test the reliability of a smartphone IMU–based gait speed measurement placed in the user’s front pants pocket in both healthy young and older adults while walking quietly (ie, normal walking) and walking while conducting a cognitive task (ie, dual-task walking). Methods: A custom-developed smartphone application (app) was used to record gait data from 12 young adults and 12 older adults during normal and dual-task walking. The validity and reliability of gait speed and step length estimations from the smartphone were compared with the gold standard GAITRite mat. A coefficient-based adjustment based upon a coefficient relative to the original estimation of step length was applied to improve the accuracy of gait speed estimation. The magnitude of error (ie, bias and limits of agreement) between the gait data from the smartphone and the GAITRite mat was calculated for each stride. The Passing-Bablok orthogonal regression model was used to provide agreement (ie, slopes and intercepts) between the smartphone and the GAITRite mat. Results: The gait speed measured by the smartphone was valid when compared to the GAITRite mat. The original limits of agreement were 0.50 m/s (an ideal value of 0 m/s), and the orthogonal regression analysis indicated a slope of 1.68 (an ideal value of 1) and an intercept of −0.70 (an ideal value of 0). After adjustment, the accuracy of the smartphone-derived gait speed estimation improved, with limits of agreement reduced to 0.34 m/s. The adjusted slope improved to 1.00, with an intercept of 0.03. The test-retest reliability of smartphone-derived gait speed was good to excellent within supervised laboratory settings and unsupervised home conditions. The adjustment coefficients were applicable to a wide range of step lengths and gait speeds. Conclusions: The inverted pendulum approach is a valid and reliable method for estimating gait speed from a smartphone IMU placed in the pockets of younger and older adults. Adjusting step length by a coefficient derived from the original estimation of step length successfully removed bias and improved the accuracy of gait speed estimation. This novel method has potential applications in various settings and populations, though fine-tuning may be necessary for specific data sets.
- Open Access
- 6 March 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (3) , 257
Validity and Reliability of a Smartphone Application for Home Measurement of Four-Meter Gait Speed in Older Adults
The four-meter gait speed (4MGS) is a recommended physical performance test in older adults but is challenging to implement clinically. We developed a smartphone application (App) with a four-meter ribbon for remote 4MGS testing at home. This study aimed to assess the validity and reliability of this smartphone App-based assessment of the home 4MGS. We assessed the validity of the smartphone App by comparing it against a gold standard video assessment of the 4MGS conducted by study staff visiting community-dwelling older adults and against the stopwatch-based measurement. Moreover, we assessed the test–retest reliability in two supervised sessions and three additional sessions performed by the participants independently, without staff supervision. The 4MGS measured by the smartphone App was highly correlated with video-based 4MGS (r = 0.94), with minimal differences (mean = 0.07 m/s, ± 1.96 SD = 0.12) across a range of gait speeds. The test–retest reliability for the smartphone App 4MGS was high (ICC values: 0.75 to 0.93). The home 4MGS in older adults can be measured accurately and reliably using a smartphone in the pants pocket and a four-meter strip of ribbon. Leveraging existing technology carried by a significant portion of the older adult population could overcome barriers in busy clinical settings for this well-established objective mobility test.
- 6 March 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (3) , 257
Open AccessValidity and Reliability of a Smartphone Application for Home Measurement of Four-Meter Gait Speed in Older Adults
The four-meter gait speed (4MGS) is a recommended physical performance test in older adults but is challenging to implement clinically. We developed a smartphone application (App) with a four-meter ribbon for remote 4MGS testing at home. This study aimed to assess the validity and reliability of this smartphone App-based assessment of the home 4MGS. We assessed the validity of the smartphone App by comparing it against a gold standard video assessment of the 4MGS conducted by study staff visiting community-dwelling older adults and against the stopwatch-based measurement. Moreover, we assessed the test–retest reliability in two supervised sessions and three additional sessions performed by the participants independently, without staff supervision. The 4MGS measured by the smartphone App was highly correlated with video-based 4MGS (r = 0.94), with minimal differences (mean = 0.07 m/s, ± 1.96 SD = 0.12) across a range of gait speeds. The test–retest reliability for the smartphone App 4MGS was high (ICC values: 0.75 to 0.93). The home 4MGS in older adults can be measured accurately and reliably using a smartphone in the pants pocket and a four-meter strip of ribbon. Leveraging existing technology carried by a significant portion of the older adult population could overcome barriers in busy clinical settings for this well-established objective mobility test.
- Open Access
- 25 August 2023
- Published by JMIR Publications Inc. in JMIR Preprints
A novel approach for improving the estimation of gait speed using a single inertial measurement unit embedded in a smartphone (Preprint)
BACKGROUND Gait speed is a valuable biomarker for mobility and health assessment in clinical and research settings. Existing methods to measure gait speed require expensive equipment or personal assistance, limiting their use in unsupervised, daily-life conditions. OBJECTIVE This study aimed to examine the validity and reliability of the inverted pendulum model approach to estimating gait speed and required spatial information (i.e., step length) from data collected with a single smartphone IMU placed in the user’s pants pocket, for both healthy younger and older adults. METHODS A custom-developed smartphone app was used to record gait data from healthy younger and older adults during normal and dual-task walking. Validity and reliability of gait speed and step length estimations from the smartphone were compared with the gold-standard GAITRite mat. A coefficient-based adjustment based upon a coefficient relative to the original estimation of step length was applied to improve the accuracy of gait speed estimation. RESULTS Smartphone-derived gait speed and step length showed good validity compared to the GAITRite mat, with minimal bias and acceptable limits of agreement. The test-retest reliability of app-derived gait speed was good to excellent within supervised laboratory settings and unsupervised home conditions. After adjustment, the accuracy of gait speed estimation improved, with reduced bias. The adjustment coefficients were applicable to a wide range of step lengths and gait speeds. CONCLUSIONS The inverted pendulum approach is a valid and reliable method for estimating gait speed from a smartphone IMU placed in the pocket of younger and older adults. Adjusting step length by a coefficient derived from the original estimation of step length successfully removed bias and improved the accuracy of gait speed estimation. This novel method has potential applications in various settings and populations, though fine-tuning may be necessary for specific datasets.
- 25 August 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessA novel approach for improving the estimation of gait speed using a single inertial measurement unit embedded in a smartphone (Preprint)
BACKGROUND Gait speed is a valuable biomarker for mobility and health assessment in clinical and research settings. Existing methods to measure gait speed require expensive equipment or personal assistance, limiting their use in unsupervised, daily-life conditions. OBJECTIVE This study aimed to examine the validity and reliability of the inverted pendulum model approach to estimating gait speed and required spatial information (i.e., step length) from data collected with a single smartphone IMU placed in the user’s pants pocket, for both healthy younger and older adults. METHODS A custom-developed smartphone app was used to record gait data from healthy younger and older adults during normal and dual-task walking. Validity and reliability of gait speed and step length estimations from the smartphone were compared with the gold-standard GAITRite mat. A coefficient-based adjustment based upon a coefficient relative to the original estimation of step length was applied to improve the accuracy of gait speed estimation. RESULTS Smartphone-derived gait speed and step length showed good validity compared to the GAITRite mat, with minimal bias and acceptable limits of agreement. The test-retest reliability of app-derived gait speed was good to excellent within supervised laboratory settings and unsupervised home conditions. After adjustment, the accuracy of gait speed estimation improved, with reduced bias. The adjustment coefficients were applicable to a wide range of step lengths and gait speeds. CONCLUSIONS The inverted pendulum approach is a valid and reliable method for estimating gait speed from a smartphone IMU placed in the pocket of younger and older adults. Adjusting step length by a coefficient derived from the original estimation of step length successfully removed bias and improved the accuracy of gait speed estimation. This novel method has potential applications in various settings and populations, though fine-tuning may be necessary for specific datasets.
- Open Access
- 19 February 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (2) , e25451
Simple Smartphone-Based Assessment of Gait Characteristics in Parkinson Disease: Validation Study
Background: Parkinson disease (PD) is a common movement disorder. Patients with PD have multiple gait impairments that result in an increased risk of falls and diminished quality of life. Therefore, gait measurement is important for the management of PD. Objective: We previously developed a smartphone-based dual-task gait assessment that was validated in healthy adults. The aim of this study was to test the validity of this gait assessment in people with PD, and to examine the association between app-derived gait metrics and the clinical and functional characteristics of PD. Methods: Fifty-two participants with clinically diagnosed PD completed assessments of walking, Movement Disorder Society Unified Parkinson Disease Rating Scale III (UPDRS III), Montreal Cognitive Assessment (MoCA), Hamilton Anxiety (HAM-A), and Hamilton Depression (HAM-D) rating scale tests. Participants followed multimedia instructions provided by the app to complete two 20-meter trials each of walking normally (single task) and walking while performing a serial subtraction dual task (dual task). Gait data were simultaneously collected with the app and gold-standard wearable motion sensors. Stride times and stride time variability were derived from the acceleration and angular velocity signal acquired from the internal motion sensor of the phone and from the wearable sensor system. Results: High correlations were observed between the stride time and stride time variability derived from the app and from the gold-standard system (r=0.98-0.99, P<.001), revealing excellent validity of the app-based gait assessment in PD. Compared with those from the single-task condition, the stride time (F1,103=14.1, P<.001) and stride time variability (F1,103=6.8, P=.008) in the dual-task condition were significantly greater. Participants who walked with greater stride time variability exhibited a greater UPDRS III total score (single task: β=.39, P<.001; dual task: β=.37, P=.01), HAM-A (single-task: β=.49, P=.007; dual-task: β=.48, P=.009), and HAM-D (single task: β=.44, P=.01; dual task: β=.49, P=.009). Moreover, those with greater dual-task stride time variability (β=.48, P=.001) or dual-task cost of stride time variability (β=.44, P=.004) exhibited lower MoCA scores. Conclusions: A smartphone-based gait assessment can be used to provide meaningful metrics of single- and dual-task gait that are associated with disease severity and functional outcomes in individuals with PD.
- 19 February 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (2) , e25451
Open AccessSimple Smartphone-Based Assessment of Gait Characteristics in Parkinson Disease: Validation Study
Background: Parkinson disease (PD) is a common movement disorder. Patients with PD have multiple gait impairments that result in an increased risk of falls and diminished quality of life. Therefore, gait measurement is important for the management of PD. Objective: We previously developed a smartphone-based dual-task gait assessment that was validated in healthy adults. The aim of this study was to test the validity of this gait assessment in people with PD, and to examine the association between app-derived gait metrics and the clinical and functional characteristics of PD. Methods: Fifty-two participants with clinically diagnosed PD completed assessments of walking, Movement Disorder Society Unified Parkinson Disease Rating Scale III (UPDRS III), Montreal Cognitive Assessment (MoCA), Hamilton Anxiety (HAM-A), and Hamilton Depression (HAM-D) rating scale tests. Participants followed multimedia instructions provided by the app to complete two 20-meter trials each of walking normally (single task) and walking while performing a serial subtraction dual task (dual task). Gait data were simultaneously collected with the app and gold-standard wearable motion sensors. Stride times and stride time variability were derived from the acceleration and angular velocity signal acquired from the internal motion sensor of the phone and from the wearable sensor system. Results: High correlations were observed between the stride time and stride time variability derived from the app and from the gold-standard system (r=0.98-0.99, P<.001), revealing excellent validity of the app-based gait assessment in PD. Compared with those from the single-task condition, the stride time (F1,103=14.1, P<.001) and stride time variability (F1,103=6.8, P=.008) in the dual-task condition were significantly greater. Participants who walked with greater stride time variability exhibited a greater UPDRS III total score (single task: β=.39, P<.001; dual task: β=.37, P=.01), HAM-A (single-task: β=.49, P=.007; dual-task: β=.48, P=.009), and HAM-D (single task: β=.44, P=.01; dual task: β=.49, P=.009). Moreover, those with greater dual-task stride time variability (β=.48, P=.001) or dual-task cost of stride time variability (β=.44, P=.004) exhibited lower MoCA scores. Conclusions: A smartphone-based gait assessment can be used to provide meaningful metrics of single- and dual-task gait that are associated with disease severity and functional outcomes in individuals with PD.
- Open Access
- 2 November 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Simple Smartphone-Based Assessment of Gait Characteristics in Parkinson Disease: Validation Study (Preprint)
BACKGROUND Parkinson disease (PD) is a common movement disorder. Patients with PD have multiple gait impairments that result in an increased risk of falls and diminished quality of life. Therefore, gait measurement is important for the management of PD. OBJECTIVE We previously developed a smartphone-based dual-task gait assessment that was validated in healthy adults. The aim of this study was to test the validity of this gait assessment in people with PD, and to examine the association between app-derived gait metrics and the clinical and functional characteristics of PD. METHODS Fifty-two participants with clinically diagnosed PD completed assessments of walking, Movement Disorder Society Unified Parkinson Disease Rating Scale III (UPDRS III), Montreal Cognitive Assessment (MoCA), Hamilton Anxiety (HAM-A), and Hamilton Depression (HAM-D) rating scale tests. Participants followed multimedia instructions provided by the app to complete two 20-meter trials each of walking normally (single task) and walking while performing a serial subtraction dual task (dual task). Gait data were simultaneously collected with the app and gold-standard wearable motion sensors. Stride times and stride time variability were derived from the acceleration and angular velocity signal acquired from the internal motion sensor of the phone and from the wearable sensor system. RESULTS High correlations were observed between the stride time and stride time variability derived from the app and from the gold-standard system (r=0.98-0.99, P<.001), revealing excellent validity of the app-based gait assessment in PD. Compared with those from the single-task condition, the stride time (F1,103=14.1, P<.001) and stride time variability (F1,103=6.8, P=.008) in the dual-task condition were significantly greater. Participants who walked with greater stride time variability exhibited a greater UPDRS III total score (single task: β=.39, P<.001; dual task: β=.37, P=.01), HAM-A (single-task: β=.49, P=.007; dual-task: β=.48, P=.009), and HAM-D (single task: β=.44, P=.01; dual task: β=.49, P=.009). Moreover, those with greater dual-task stride time variability (β=.48, P=.001) or dual-task cost of stride time variability (β=.44, P=.004) exhibited lower MoCA scores. CONCLUSIONS A smartphone-based gait assessment can be used to provide meaningful metrics of single- and dual-task gait that are associated with disease severity and functional outcomes in individuals with PD.
- 2 November 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessSimple Smartphone-Based Assessment of Gait Characteristics in Parkinson Disease: Validation Study (Preprint)
BACKGROUND Parkinson disease (PD) is a common movement disorder. Patients with PD have multiple gait impairments that result in an increased risk of falls and diminished quality of life. Therefore, gait measurement is important for the management of PD. OBJECTIVE We previously developed a smartphone-based dual-task gait assessment that was validated in healthy adults. The aim of this study was to test the validity of this gait assessment in people with PD, and to examine the association between app-derived gait metrics and the clinical and functional characteristics of PD. METHODS Fifty-two participants with clinically diagnosed PD completed assessments of walking, Movement Disorder Society Unified Parkinson Disease Rating Scale III (UPDRS III), Montreal Cognitive Assessment (MoCA), Hamilton Anxiety (HAM-A), and Hamilton Depression (HAM-D) rating scale tests. Participants followed multimedia instructions provided by the app to complete two 20-meter trials each of walking normally (single task) and walking while performing a serial subtraction dual task (dual task). Gait data were simultaneously collected with the app and gold-standard wearable motion sensors. Stride times and stride time variability were derived from the acceleration and angular velocity signal acquired from the internal motion sensor of the phone and from the wearable sensor system. RESULTS High correlations were observed between the stride time and stride time variability derived from the app and from the gold-standard system (r=0.98-0.99, P<.001), revealing excellent validity of the app-based gait assessment in PD. Compared with those from the single-task condition, the stride time (F1,103=14.1, P<.001) and stride time variability (F1,103=6.8, P=.008) in the dual-task condition were significantly greater. Participants who walked with greater stride time variability exhibited a greater UPDRS III total score (single task: β=.39, P<.001; dual task: β=.37, P=.01), HAM-A (single-task: β=.49, P=.007; dual-task: β=.48, P=.009), and HAM-D (single task: β=.44, P=.01; dual task: β=.49, P=.009). Moreover, those with greater dual-task stride time variability (β=.48, P=.001) or dual-task cost of stride time variability (β=.44, P=.004) exhibited lower MoCA scores. CONCLUSIONS A smartphone-based gait assessment can be used to provide meaningful metrics of single- and dual-task gait that are associated with disease severity and functional outcomes in individuals with PD.
- Open Access
- 30 January 2018
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 6 (1) , e36
Smartphone App–Based Assessment of Gait During Normal and Dual-Task Walking: Demonstration of Validity and Reliability
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.
- 30 January 2018
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 6 (1) , e36
Open AccessSmartphone App–Based Assessment of Gait During Normal and Dual-Task Walking: Demonstration of Validity and Reliability
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.
- Open Access
- 23 August 2017
- Published by JMIR Publications Inc. in JMIR Preprints
Smartphone App Based Assessment of Gait During Normal and Dual-Task Walking: Demonstration of Validity and Reliability (Preprint)
BACKGROUND Walking is a complex cognitive motor task that is commonly completed while performing another task such as talking or making decisions. Gait assessments performed under normal and “dual-task” walking conditions thus provide important insights into health. Such assessments, however, are limited primarily to laboratory-based settings. OBJECTIVE The objective of our study was to create and test a smartphone-based assessment of normal and dual-task walking for use in nonlaboratory settings. METHODS We created an iPhone app that used the phone’s motion sensors to record movements during walking under normal conditions and while performing a serial-subtraction dual task, with the phone placed in the user’s pants pocket. The app provided the user with multimedia instructions before and during the assessment. Acquired data were automatically uploaded to a cloud-based server for offline analyses. A total of 14 healthy adults completed 2 laboratory visits separated by 1 week. On each visit, they used the app to complete three 45-second trials each of normal and dual-task walking. Kinematic data were collected with the app and a gold-standard–instrumented GAITRite mat. Participants also used the app to complete normal and dual-task walking trials within their homes on 3 separate days. Within laboratory-based trials, GAITRite-derived heel strikes and toe-offs of the phone-side leg aligned with smartphone acceleration extrema, following filtering and rotation to the earth coordinate system. We derived stride times—a clinically meaningful metric of locomotor control—from GAITRite and app data, for all strides occurring over the GAITRite mat. We calculated stride times and the dual-task cost to the average stride time (ie, percentage change from normal to dual-task conditions) from both measurement devices. We calculated similar metrics from home-based app data. For these trials, periods of potential turning were identified via custom-developed algorithms and omitted from stride-time analyses. RESULTS Across all detected strides in the laboratory, stride times derived from the app and GAITRite mat were highly correlated (P<.001, r2=.98). These correlations were independent of walking condition and pocket tightness. App- and GAITRite-derived stride-time dual-task costs were also highly correlated (P<.001, r2=.95). The error of app-derived stride times (mean 16.9, SD 9.0 ms) was unaffected by the magnitude of stride time, walking condition, or pocket tightness. For both normal and dual-task trials, average stride times derived from app walking trials demonstrated excellent test-retest reliability within and between both laboratory and home-based assessments (intraclass correlation coefficient range .82-.94). CONCLUSIONS The iPhone app we created enabled valid and reliable assessment of stride timing—with the smartphone in the pocket—during both normal and dual-task walking and within both laboratory and nonlaboratory environments. Additional work is warranted to expand the functionality of this tool to older adults and other patient populations.
- 23 August 2017
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessSmartphone App Based Assessment of Gait During Normal and Dual-Task Walking: Demonstration of Validity and Reliability (Preprint)
BACKGROUND Walking is a complex cognitive motor task that is commonly completed while performing another task such as talking or making decisions. Gait assessments performed under normal and “dual-task” walking conditions thus provide important insights into health. Such assessments, however, are limited primarily to laboratory-based settings. OBJECTIVE The objective of our study was to create and test a smartphone-based assessment of normal and dual-task walking for use in nonlaboratory settings. METHODS We created an iPhone app that used the phone’s motion sensors to record movements during walking under normal conditions and while performing a serial-subtraction dual task, with the phone placed in the user’s pants pocket. The app provided the user with multimedia instructions before and during the assessment. Acquired data were automatically uploaded to a cloud-based server for offline analyses. A total of 14 healthy adults completed 2 laboratory visits separated by 1 week. On each visit, they used the app to complete three 45-second trials each of normal and dual-task walking. Kinematic data were collected with the app and a gold-standard–instrumented GAITRite mat. Participants also used the app to complete normal and dual-task walking trials within their homes on 3 separate days. Within laboratory-based trials, GAITRite-derived heel strikes and toe-offs of the phone-side leg aligned with smartphone acceleration extrema, following filtering and rotation to the earth coordinate system. We derived stride times—a clinically meaningful metric of locomotor control—from GAITRite and app data, for all strides occurring over the GAITRite mat. We calculated stride times and the dual-task cost to the average stride time (ie, percentage change from normal to dual-task conditions) from both measurement devices. We calculated similar metrics from home-based app data. For these trials, periods of potential turning were identified via custom-developed algorithms and omitted from stride-time analyses. RESULTS Across all detected strides in the laboratory, stride times derived from the app and GAITRite mat were highly correlated (P<.001, r2=.98). These correlations were independent of walking condition and pocket tightness. App- and GAITRite-derived stride-time dual-task costs were also highly correlated (P<.001, r2=.95). The error of app-derived stride times (mean 16.9, SD 9.0 ms) was unaffected by the magnitude of stride time, walking condition, or pocket tightness. For both normal and dual-task trials, average stride times derived from app walking trials demonstrated excellent test-retest reliability within and between both laboratory and home-based assessments (intraclass correlation coefficient range .82-.94). CONCLUSIONS The iPhone app we created enabled valid and reliable assessment of stride timing—with the smartphone in the pocket—during both normal and dual-task walking and within both laboratory and nonlaboratory environments. Additional work is warranted to expand the functionality of this tool to older adults and other patient populations.