Anna Narezkina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anna Narezkina has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Anthony Nicholas DeMaria
Judith and Jack White Chair in Cardiology, University of California, San Diego, La Jolla, California, USA
2 shared publications - Jonathan Chong Hsu
University of California, San Diego
2 shared publications - Kevin Patrick
Qualcomm Institute, University of California San Diego, La Jolla, CA 92093, USA
2 shared publications - Kunal Vipul Shah
UC San Diego, La Jolla, CA, USA
2 shared publications - Nathan Magalit
Department of Medicine, Division of Cardiovascular Medicine, University of California San Diego, San Diego, CA, United States, 1 81896772759
2 shared publications - Ryan Moran
Department of Medicine, Division of Cardiovascular Medicine, University of California San Diego, San Diego, CA, United States, 1 81896772759
2 shared publications
Latest Publications
- Open Access
- 22 October 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e100115
Wireless Home Blood Pressure Monitoring With Health Coaching for Hypertension Management at a Federally Qualified Health Center: Pilot Randomized Controlled Feasibility and Acceptability Study
Background: Only approximately half of adults with hypertension, a leading cardiovascular risk factor, achieve blood pressure (BP) control, with persistent disparities among low-income and minority populations. Wireless home BP monitoring (HBPM) with remote patient monitoring can improve BP control, but evidence is limited in medically underserved, predominantly Hispanic populations served by federally qualified health centers (FQHCs). Objective: The primary objective was to evaluate the feasibility and acceptability of wireless HBPM among predominantly Hispanic adults with hypertension receiving FQHC care. Comparing BP outcomes between wireless and conventional HBPM was a secondary exploratory objective. Methods: We conducted a 6-month, 2-arm randomized controlled pilot feasibility and acceptability trial nested within the San Diego: Heart Attack and Stroke Free Zone program. Adults aged ≥18 years with uncontrolled or newly diagnosed hypertension (BP ≥140/90 mm Hg) were enrolled across 3 FQHC networks and randomized 1:1 by unrestricted simple randomization to wireless HBPM (Bluetooth cuff and cellular hub; weekly transmitted summaries reviewed by health coaches) or standard HBPM (home monitor with paper log). Both arms received standardized health coaching. The primary outcomes were feasibility (proportion of 210 expected BP readings transmitted) and acceptability (postintervention satisfaction survey in the wireless arm). Exploratory analyses compared BP outcomes between arms among participants with >2 BP measurements. Results: Of 316 recruited participants, 290 (92%) were eligible, and 200 (63%) were analyzed (wireless: n=73, 23%; and standard: n=127, 40%); arm-level allocation counts were not retained. The mean age was 61 years (SD 9.1), 57% (115/200) were women, and 51% (n=102) self-identified as Hispanic, with no significant baseline differences between arms. Among analyzed wireless-arm participants, 86% (63/73) transmitted multiple readings (mean 160.6, SD 129.1) over 6 months, corresponding to 76.2% (160/210) of expected readings among transmitting participants and 66% across all 73; only 5% (7/127) of standard-arm participants returned paper logs. Of 60 respondents (82.2% response rate), 95% (n=57) agreed or strongly agreed that the device was easy to set up and use. Both arms showed significant within-arm BP reductions at 6 months ( P <.001). At 6 months, 63% (46/73) of the wireless arm and 74% (94/127) of the standard arm achieved systolic BP P =.08; adjusted odds ratio, standard vs wireless, 1.6, 95% CI 0.78‐3.4; P =.19). These exploratory comparisons were not powered and do not constitute evidence of equivalence. Conclusions: Among analyzed participants, wireless HBPM was feasible, and survey respondents reported high acceptability in a medically underserved, predominantly Hispanic FQHC population. Feasibility among all randomized participants could not be estimated because arm-level allocation counts were not retained. The absence of a between-arm difference in BP control is not evidence of equivalence because this pilot was not powered to compare clinical effectiveness; the BP findings are hypothesis generating.
- 22 October 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e100115
Open AccessWireless Home Blood Pressure Monitoring With Health Coaching for Hypertension Management at a Federally Qualified Health Center: Pilot Randomized Controlled Feasibility and Acceptability Study
Background: Only approximately half of adults with hypertension, a leading cardiovascular risk factor, achieve blood pressure (BP) control, with persistent disparities among low-income and minority populations. Wireless home BP monitoring (HBPM) with remote patient monitoring can improve BP control, but evidence is limited in medically underserved, predominantly Hispanic populations served by federally qualified health centers (FQHCs). Objective: The primary objective was to evaluate the feasibility and acceptability of wireless HBPM among predominantly Hispanic adults with hypertension receiving FQHC care. Comparing BP outcomes between wireless and conventional HBPM was a secondary exploratory objective. Methods: We conducted a 6-month, 2-arm randomized controlled pilot feasibility and acceptability trial nested within the San Diego: Heart Attack and Stroke Free Zone program. Adults aged ≥18 years with uncontrolled or newly diagnosed hypertension (BP ≥140/90 mm Hg) were enrolled across 3 FQHC networks and randomized 1:1 by unrestricted simple randomization to wireless HBPM (Bluetooth cuff and cellular hub; weekly transmitted summaries reviewed by health coaches) or standard HBPM (home monitor with paper log). Both arms received standardized health coaching. The primary outcomes were feasibility (proportion of 210 expected BP readings transmitted) and acceptability (postintervention satisfaction survey in the wireless arm). Exploratory analyses compared BP outcomes between arms among participants with >2 BP measurements. Results: Of 316 recruited participants, 290 (92%) were eligible, and 200 (63%) were analyzed (wireless: n=73, 23%; and standard: n=127, 40%); arm-level allocation counts were not retained. The mean age was 61 years (SD 9.1), 57% (115/200) were women, and 51% (n=102) self-identified as Hispanic, with no significant baseline differences between arms. Among analyzed wireless-arm participants, 86% (63/73) transmitted multiple readings (mean 160.6, SD 129.1) over 6 months, corresponding to 76.2% (160/210) of expected readings among transmitting participants and 66% across all 73; only 5% (7/127) of standard-arm participants returned paper logs. Of 60 respondents (82.2% response rate), 95% (n=57) agreed or strongly agreed that the device was easy to set up and use. Both arms showed significant within-arm BP reductions at 6 months ( P <.001). At 6 months, 63% (46/73) of the wireless arm and 74% (94/127) of the standard arm achieved systolic BP P =.08; adjusted odds ratio, standard vs wireless, 1.6, 95% CI 0.78‐3.4; P =.19). These exploratory comparisons were not powered and do not constitute evidence of equivalence. Conclusions: Among analyzed participants, wireless HBPM was feasible, and survey respondents reported high acceptability in a medically underserved, predominantly Hispanic FQHC population. Feasibility among all randomized participants could not be estimated because arm-level allocation counts were not retained. The absence of a between-arm difference in BP control is not evidence of equivalence because this pilot was not powered to compare clinical effectiveness; the BP findings are hypothesis generating.
- Open Access
- 5 May 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Wireless Home Blood Pressure Monitoring for Hypertension Management at a Federally Qualified Health Center: A Pilot Randomized Controlled Trial (Preprint)
BACKGROUND Hypertension is a leading cardiovascular risk factor, yet only about half of affected individuals achieve blood pressure (BP) control, with persistent disparities among low-income and racial/ethnic minority populations. Wireless home blood pressure monitoring (HBPM) integrated with remote patient monitoring shows promise for improving BP management, but evidence is limited in medically underserved, predominantly Hispanic populations served by Federally Qualified Health Centers (FQHCs). OBJECTIVE This pilot study aimed to evaluate the feasibility and acceptability of wireless HBPM among predominantly Hispanic adults with hypertension receiving care at FQHCs and to explore its effect on BP control compared with conventional HBPM using paper logs. METHODS We conducted a 6-month prospective, two-arm randomized controlled pilot trial nested within the San Diego: Heart Attack and Stroke Free Zone cardiovascular risk-reduction program. Adults aged ≥18 years with uncontrolled or newly diagnosed hypertension (BP ≥140/90 mmHg) were enrolled across three FQHC networks and randomized to a wireless HBPM arm (Qualcomm Life 2NET hub with an A&D UA-651 BLE monitor; weekly transmitted summaries reviewed by health coaches) or a standard arm (calibrated home BP monitor with paper log). Both arms received standardized health coaching. Feasibility was defined as the proportion of expected BP readings successfully transmitted; acceptability was assessed via a post-intervention satisfaction survey in the wireless arm. Exploratory analyses compared BP outcomes between arms using t-tests, chi-square/Fisher exact tests, and multivariable logistic regression. RESULTS Of 200 participants (73 wireless; 127 standard), mean age was 61 years, 57% were women, and 51% self-identified as Hispanic, with no significant baseline differences between arms. In the wireless arm, 86% (63/73) successfully transmitted multiple readings, with a median of 159 readings (mean 160.6, SD 129.1) over 6 months, corresponding to 76.2% adherence to the prescribed schedule; only 5% of standard-arm participants returned their paper logs. On the satisfaction survey (response rate 82.2%), 95% agreed or strongly agreed that the device was easy to set up and use, and 75% reported they would more consistently use the wireless than the conventional cuff. Both arms showed significant reductions in systolic and diastolic BP at 6 months (P<.001). At 6 months, 63% of the wireless arm and 74% of the standard arm achieved systolic BP <140 mmHg (P=.079); adjusted analyses showed no significant between-group difference in BP control (adjusted odds ratio 1.6, 95% CI 0.78-3.4; P=.19). CONCLUSIONS Wireless HBPM was feasible and highly acceptable in a medically underserved, predominantly Hispanic FQHC population, with strong data-transmission adherence and high user satisfaction. Although this pilot was not powered for definitive efficacy comparisons, the findings support wireless HBPM as a viable platform for hypertension management in underserved settings and offer foundational evidence to inform contemporary digital health and remote patient monitoring program design.
- 5 May 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessWireless Home Blood Pressure Monitoring for Hypertension Management at a Federally Qualified Health Center: A Pilot Randomized Controlled Trial (Preprint)
BACKGROUND Hypertension is a leading cardiovascular risk factor, yet only about half of affected individuals achieve blood pressure (BP) control, with persistent disparities among low-income and racial/ethnic minority populations. Wireless home blood pressure monitoring (HBPM) integrated with remote patient monitoring shows promise for improving BP management, but evidence is limited in medically underserved, predominantly Hispanic populations served by Federally Qualified Health Centers (FQHCs). OBJECTIVE This pilot study aimed to evaluate the feasibility and acceptability of wireless HBPM among predominantly Hispanic adults with hypertension receiving care at FQHCs and to explore its effect on BP control compared with conventional HBPM using paper logs. METHODS We conducted a 6-month prospective, two-arm randomized controlled pilot trial nested within the San Diego: Heart Attack and Stroke Free Zone cardiovascular risk-reduction program. Adults aged ≥18 years with uncontrolled or newly diagnosed hypertension (BP ≥140/90 mmHg) were enrolled across three FQHC networks and randomized to a wireless HBPM arm (Qualcomm Life 2NET hub with an A&D UA-651 BLE monitor; weekly transmitted summaries reviewed by health coaches) or a standard arm (calibrated home BP monitor with paper log). Both arms received standardized health coaching. Feasibility was defined as the proportion of expected BP readings successfully transmitted; acceptability was assessed via a post-intervention satisfaction survey in the wireless arm. Exploratory analyses compared BP outcomes between arms using t-tests, chi-square/Fisher exact tests, and multivariable logistic regression. RESULTS Of 200 participants (73 wireless; 127 standard), mean age was 61 years, 57% were women, and 51% self-identified as Hispanic, with no significant baseline differences between arms. In the wireless arm, 86% (63/73) successfully transmitted multiple readings, with a median of 159 readings (mean 160.6, SD 129.1) over 6 months, corresponding to 76.2% adherence to the prescribed schedule; only 5% of standard-arm participants returned their paper logs. On the satisfaction survey (response rate 82.2%), 95% agreed or strongly agreed that the device was easy to set up and use, and 75% reported they would more consistently use the wireless than the conventional cuff. Both arms showed significant reductions in systolic and diastolic BP at 6 months (P<.001). At 6 months, 63% of the wireless arm and 74% of the standard arm achieved systolic BP <140 mmHg (P=.079); adjusted analyses showed no significant between-group difference in BP control (adjusted odds ratio 1.6, 95% CI 0.78-3.4; P=.19). CONCLUSIONS Wireless HBPM was feasible and highly acceptable in a medically underserved, predominantly Hispanic FQHC population, with strong data-transmission adherence and high user satisfaction. Although this pilot was not powered for definitive efficacy comparisons, the findings support wireless HBPM as a viable platform for hypertension management in underserved settings and offer foundational evidence to inform contemporary digital health and remote patient monitoring program design.
- Open Access
Deep learning enables fully automated cineCT-based assessment of regional right ventricular function
Background: Right ventricular (RV) function is a key factor in the diagnosis and prognosis of heart disease. However, current advanced CT-based assessments rely on semi-automated segmentation of the RV blood pool and manual delineation of the RV free and septal wall boundaries. Both of these steps are time-consuming and prone to inter- and intra-observer variability. Methods: We developed and evaluated a fully automated pipeline consisting of two deep learning methods to automate volumetric and regional strain analysis of the RV from contrast-enhanced, ECG-gated cineCT images. The Right Heart Blood Segmenter (RHBS) is a 3D high resolution configuration of nnU-Net to define the endocardial boundary, while the Right Ventricular Wall Labeler (RVWL) is a 3D point cloud-based deep learning method to label the free and septal walls. We trained our models using a diverse cohort of patients with different RV phenotypes and tested in an independent cohort of patients with aortic stenosis undergoing TAVR. Results: Our approach demonstrated high accuracy in both cross-validation and independent validation cohorts. RHBS and RVWL both yielded Dice scores of 0.96, and accurate volumetry metrics. RVWL achieved high Dice scores (>0.90) and high accuracy (>93%) for wall labeling. The combination of RHBS and RVWL provided accurate assessment of free and septal wall regional strain, with a median cosine similarity value of 0.97 in the independent cohort. Conclusions: A fully automated 3D cineCT-based RV regional strain analysis pipeline has the potential to significantly enhance the efficiency and reproducibility of RV function assessment, enabling the evaluation of large cohorts and multi-center studies. Key Points: RV endocardial segmentation of contrast enhanced CT scans can be utilized to perform volumetry, and when paired with labeling of free and septal walls, regional evaluation of surface strain. However, this has previously been performed using time-intensive semi-automated segmentation methods and manually labeling free wall and septal wall regions.. Here, we describe an automated, deep learning-based approach which uses two separate DL models to define the endocardial boundary (in 3D) and then label the free and septal walls on the endocardial surface. Our approach facilitates rapid and automatic advanced phenotyping of patients. This reduces prior limitations of potential interobserver variability and challenges associated with evaluating large cohorts.
Open AccessDeep learning enables fully automated cineCT-based assessment of regional right ventricular function
Background: Right ventricular (RV) function is a key factor in the diagnosis and prognosis of heart disease. However, current advanced CT-based assessments rely on semi-automated segmentation of the RV blood pool and manual delineation of the RV free and septal wall boundaries. Both of these steps are time-consuming and prone to inter- and intra-observer variability. Methods: We developed and evaluated a fully automated pipeline consisting of two deep learning methods to automate volumetric and regional strain analysis of the RV from contrast-enhanced, ECG-gated cineCT images. The Right Heart Blood Segmenter (RHBS) is a 3D high resolution configuration of nnU-Net to define the endocardial boundary, while the Right Ventricular Wall Labeler (RVWL) is a 3D point cloud-based deep learning method to label the free and septal walls. We trained our models using a diverse cohort of patients with different RV phenotypes and tested in an independent cohort of patients with aortic stenosis undergoing TAVR. Results: Our approach demonstrated high accuracy in both cross-validation and independent validation cohorts. RHBS and RVWL both yielded Dice scores of 0.96, and accurate volumetry metrics. RVWL achieved high Dice scores (>0.90) and high accuracy (>93%) for wall labeling. The combination of RHBS and RVWL provided accurate assessment of free and septal wall regional strain, with a median cosine similarity value of 0.97 in the independent cohort. Conclusions: A fully automated 3D cineCT-based RV regional strain analysis pipeline has the potential to significantly enhance the efficiency and reproducibility of RV function assessment, enabling the evaluation of large cohorts and multi-center studies. Key Points: RV endocardial segmentation of contrast enhanced CT scans can be utilized to perform volumetry, and when paired with labeling of free and septal walls, regional evaluation of surface strain. However, this has previously been performed using time-intensive semi-automated segmentation methods and manually labeling free wall and septal wall regions.. Here, we describe an automated, deep learning-based approach which uses two separate DL models to define the endocardial boundary (in 3D) and then label the free and septal walls on the endocardial surface. Our approach facilitates rapid and automatic advanced phenotyping of patients. This reduces prior limitations of potential interobserver variability and challenges associated with evaluating large cohorts.
- 1 February 2024
- Published by American Society of Clinical Oncology (ASCO) in JCO Precision Oncology
- Vol. 8 (8) , e2300265
Repotrectinib in a Patient With NTRK Fusion-Positive Pancreatic Carcinoma and Congenital Long QT Syndrome
Repotrectinib in a patient with NTRK fusion–positive pancreatic carcinoma and congenital long QT syndrome.
- 1 February 2024
- Published by American Society of Clinical Oncology (ASCO) in JCO Precision Oncology
- Vol. 8 (8) , e2300265
Repotrectinib in a Patient With NTRK Fusion-Positive Pancreatic Carcinoma and Congenital Long QT Syndrome
Repotrectinib in a patient with NTRK fusion–positive pancreatic carcinoma and congenital long QT syndrome.
- Open Access
- 1 April 2021
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 7 (4) , 242-245
Successful use of a prophylactic cerebral protection device via the radial artery during left atrial appendage occlusion device implantation in a patient with a mitral valve mass
- 1 April 2021
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 7 (4) , 242-245
Open AccessSuccessful use of a prophylactic cerebral protection device via the radial artery during left atrial appendage occlusion device implantation in a patient with a mitral valve mass