Wonil Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wonil Lee has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- HyunWook Park
School of Electrical Engineering KAIST Daejeon
4 shared publications - Chao Ma
Yale School of Medicine, Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA
3 shared publications - Paul Kyu Han
Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT, USA
3 shared publications - Didi Chi
Yale Biomedical Imaging Institute Yale University School of Medicine New Haven Connecticut USA
2 shared publications Felicitas J. Bijari
Yale Biomedical Imaging Institute Yale University School of Medicine New Haven Connecticut USA
2 shared publications- Ismaël B. G. Mounime
Yale Biomedical Imaging Institute Yale University School of Medicine New Haven Connecticut USA
2 shared publications
Latest Publications
- Open Access
- 13 March 2026
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
High-resolution in utero SV2A PET imaging of the nonhuman primate brain using the NeuroEXPLORER
The NeuroEXPLORER (NX), a next generation brain-dedicated PET scanner, has demonstrated improved spatial resolution and sensitivity compared with previous PET scanners. In this study, we performed synaptic vesicle glycoprotein 2A (SV2A) PET, an in vivo marker of synaptic density, to evaluate the performance of the NX in both fetal and maternal brains of four pregnant rhesus macaques. Results were compared with the previously acquired PET images using miniEXPLORER and Biograph mCT for fetal and maternal brains (four pregnant monkeys per scanner). The NX demonstrated superior performance compared with the other scanners, providing improved image clarity and higher distribution volume ratios (DVRs), which were significant in the occipital region and putamen of the fetal brain ( p < 0.05, FDR uncorrected), as well as across all regions in the maternal brain ( p < 0.05, FDR corrected). The percentage difference in mean regional DVR between maternal and fetal brains ranged from 36.1% in the amygdala to 78.3% in the occipital lobe in the NX, which may reflect regional differences in the phase of synaptic development. This study highlights the NX as a promising non-invasive tool for investigating in utero synaptic development. The presence of in utero motion emphasizes the necessity of motion correction for reliable PET quantification.
- 13 March 2026
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
Open AccessHigh-resolution in utero SV2A PET imaging of the nonhuman primate brain using the NeuroEXPLORER
The NeuroEXPLORER (NX), a next generation brain-dedicated PET scanner, has demonstrated improved spatial resolution and sensitivity compared with previous PET scanners. In this study, we performed synaptic vesicle glycoprotein 2A (SV2A) PET, an in vivo marker of synaptic density, to evaluate the performance of the NX in both fetal and maternal brains of four pregnant rhesus macaques. Results were compared with the previously acquired PET images using miniEXPLORER and Biograph mCT for fetal and maternal brains (four pregnant monkeys per scanner). The NX demonstrated superior performance compared with the other scanners, providing improved image clarity and higher distribution volume ratios (DVRs), which were significant in the occipital region and putamen of the fetal brain ( p < 0.05, FDR uncorrected), as well as across all regions in the maternal brain ( p < 0.05, FDR corrected). The percentage difference in mean regional DVR between maternal and fetal brains ranged from 36.1% in the amygdala to 78.3% in the occipital lobe in the NX, which may reflect regional differences in the phase of synaptic development. This study highlights the NX as a promising non-invasive tool for investigating in utero synaptic development. The presence of in utero motion emphasizes the necessity of motion correction for reliable PET quantification.
- Open Access
- 8 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3360-3368
Free‐Running Three‐Dimensional Cardiac Extracellular Volume Mapping in a Single Scan With Mid‐Scan Contrast Injection
Purpose: To develop a new method for free‐running three‐dimensional (3D) extracellular volume mapping of the heart in a single scan with mid‐scan contrast injection. Methods: 3D cardiac MR imaging was performed with a single scan that acquired k ‐space data continuously using an inversion recovery (IR) sequence with a spoiled gradient‐echo readout. Contrast agent was injected in the middle of the scan. Dynamic images were reconstructed utilizing a linear tangent space alignment (LTSA) model. The pre‐ and postcontrast T 1 * was estimated by finding the best fit between the measured signal and the MR signal model, which assumes a linearly time‐varying R 1 * that accounts for T 1 * changes after the contrast agent injection. Cardiac cine images were synthesized by fitting with the signal model. The 3D ECV mapping was performed using the 3D pre‐ and postcontrast T 1 * maps and the measured hematocrit level from blood sampling. Results: The feasibility of the proposed method was demonstrated through in vivo studies conducted on three healthy subjects using a 3T MR scanner. The ECV maps from the proposed method showed good agreement with those from the MOLLI method. The estimated average myocardial ECV from the proposed and MOLLI methods was 29.82% ± 2.45% and 29.28% ± 2.15%, respectively. The cine images from the proposed method successfully captured the heart's motion. The estimated ejection fraction was 63.3% ± 8%, which was in good agreement with literature values. Conclusion: We developed a novel approach that allows 3D cardiac ECV mapping in a single, free‐running, continuous 15‐min scan with mid‐scan contrast injection.
- 8 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3360-3368
Open AccessFree‐Running Three‐Dimensional Cardiac Extracellular Volume Mapping in a Single Scan With Mid‐Scan Contrast Injection
Purpose: To develop a new method for free‐running three‐dimensional (3D) extracellular volume mapping of the heart in a single scan with mid‐scan contrast injection. Methods: 3D cardiac MR imaging was performed with a single scan that acquired k ‐space data continuously using an inversion recovery (IR) sequence with a spoiled gradient‐echo readout. Contrast agent was injected in the middle of the scan. Dynamic images were reconstructed utilizing a linear tangent space alignment (LTSA) model. The pre‐ and postcontrast T 1 * was estimated by finding the best fit between the measured signal and the MR signal model, which assumes a linearly time‐varying R 1 * that accounts for T 1 * changes after the contrast agent injection. Cardiac cine images were synthesized by fitting with the signal model. The 3D ECV mapping was performed using the 3D pre‐ and postcontrast T 1 * maps and the measured hematocrit level from blood sampling. Results: The feasibility of the proposed method was demonstrated through in vivo studies conducted on three healthy subjects using a 3T MR scanner. The ECV maps from the proposed method showed good agreement with those from the MOLLI method. The estimated average myocardial ECV from the proposed and MOLLI methods was 29.82% ± 2.45% and 29.28% ± 2.15%, respectively. The cine images from the proposed method successfully captured the heart's motion. The estimated ejection fraction was 63.3% ± 8%, which was in good agreement with literature values. Conclusion: We developed a novel approach that allows 3D cardiac ECV mapping in a single, free‐running, continuous 15‐min scan with mid‐scan contrast injection.
- 14 October 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (2) , 536-549
Free‐breathing 3D cardiac extracellular volume (ECV) mapping using a linear tangent space alignment (LTSA) model
Purpose: To develop a new method for free‐breathing 3D extracellular volume (ECV) mapping of the whole heart at 3 T.Methods: A free‐breathing 3D cardiac ECV mapping method was developed at 3 T. T1 mapping was performed before and after contrast agent injection using a free‐breathing electrocardiogram‐gated inversion recovery sequence with spoiled gradient echo readout. A linear tangent space alignment model‐based method was used to reconstruct high‐frame‐rate dynamic images from (k,t)‐space data sparsely sampled along a random stack‐of‐stars trajectory. Joint T1 and transmit B1 estimation were performed voxel‐by‐voxel for pre‐ and post‐contrast T1 mapping. To account for the time‐varying T1 after contrast agent injection, a linearly time‐varying T1 model was introduced for post‐contrast T1 mapping. ECV maps were generated by aligning pre‐ and post‐contrast T1 maps through affine transformation.Results: The feasibility of the proposed method was demonstrated using in vivo studies with six healthy volunteers at 3 T. We obtained 3D ECV maps at a spatial resolution of 1.9 × 1.9 × 4.5 mm3 and a FOV of 308 × 308 × 144 mm3, with a scan time of 10.1 ± 1.4 and 10.6 ± 1.6 min before and after contrast agent injection, respectively. The ECV maps and the pre‐ and post‐contrast T1 maps obtained by the proposed method were in good agreement with the 2D MOLLI method both qualitatively and quantitatively.Conclusion: The proposed method allows for free‐breathing 3D ECV mapping of the whole heart within a practically feasible imaging time. The estimated ECV values from the proposed method were comparable to those from the existing method.
- 14 October 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (2) , 536-549
Free‐breathing 3D cardiac extracellular volume (ECV) mapping using a linear tangent space alignment (LTSA) model
Purpose: To develop a new method for free‐breathing 3D extracellular volume (ECV) mapping of the whole heart at 3 T.Methods: A free‐breathing 3D cardiac ECV mapping method was developed at 3 T. T1 mapping was performed before and after contrast agent injection using a free‐breathing electrocardiogram‐gated inversion recovery sequence with spoiled gradient echo readout. A linear tangent space alignment model‐based method was used to reconstruct high‐frame‐rate dynamic images from (k,t)‐space data sparsely sampled along a random stack‐of‐stars trajectory. Joint T1 and transmit B1 estimation were performed voxel‐by‐voxel for pre‐ and post‐contrast T1 mapping. To account for the time‐varying T1 after contrast agent injection, a linearly time‐varying T1 model was introduced for post‐contrast T1 mapping. ECV maps were generated by aligning pre‐ and post‐contrast T1 maps through affine transformation.Results: The feasibility of the proposed method was demonstrated using in vivo studies with six healthy volunteers at 3 T. We obtained 3D ECV maps at a spatial resolution of 1.9 × 1.9 × 4.5 mm3 and a FOV of 308 × 308 × 144 mm3, with a scan time of 10.1 ± 1.4 and 10.6 ± 1.6 min before and after contrast agent injection, respectively. The ECV maps and the pre‐ and post‐contrast T1 maps obtained by the proposed method were in good agreement with the 2D MOLLI method both qualitatively and quantitatively.Conclusion: The proposed method allows for free‐breathing 3D ECV mapping of the whole heart within a practically feasible imaging time. The estimated ECV values from the proposed method were comparable to those from the existing method.
- Open Access
- 27 June 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (5) , 1980-1994
Self‐supervised learning for denoising of multidimensional MRI data
Purpose: To develop a fast denoising framework for high‐dimensional MRI data based on a self‐supervised learning scheme, which does not require ground truth clean image.Theory and Methods: Quantitative MRI faces limitations in SNR, because the variation of signal amplitude in a large set of images is the key mechanism for quantification. In addition, the complex non‐linear signal models make the fitting process vulnerable to noise. To address these issues, we propose a fast deep‐learning framework for denoising, which efficiently exploits the redundancy in multidimensional MRI data. A self‐supervised model was designed to use only noisy images for training, bypassing the challenge of clean data paucity in clinical practice. For validation, we used two different datasets of simulated magnetization transfer contrast MR fingerprinting (MTC‐MRF) dataset and in vivo DWI image dataset to show the generalizability.Results: The proposed method drastically improved denoising performance in the presence of mild‐to‐severe noise regardless of noise distributions compared to previous methods of the BM3D, tMPPCA, and Patch2self. The improvements were even pronounced in the following quantification results from the denoised images.Conclusion: The proposed MD‐S2S (Multidimensional‐Self2Self) denoising technique could be further applied to various multi‐dimensional MRI data and improve the quantification accuracy of tissue parameter maps.
- 27 June 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (5) , 1980-1994
Open AccessSelf‐supervised learning for denoising of multidimensional MRI data
Purpose: To develop a fast denoising framework for high‐dimensional MRI data based on a self‐supervised learning scheme, which does not require ground truth clean image.Theory and Methods: Quantitative MRI faces limitations in SNR, because the variation of signal amplitude in a large set of images is the key mechanism for quantification. In addition, the complex non‐linear signal models make the fitting process vulnerable to noise. To address these issues, we propose a fast deep‐learning framework for denoising, which efficiently exploits the redundancy in multidimensional MRI data. A self‐supervised model was designed to use only noisy images for training, bypassing the challenge of clean data paucity in clinical practice. For validation, we used two different datasets of simulated magnetization transfer contrast MR fingerprinting (MTC‐MRF) dataset and in vivo DWI image dataset to show the generalizability.Results: The proposed method drastically improved denoising performance in the presence of mild‐to‐severe noise regardless of noise distributions compared to previous methods of the BM3D, tMPPCA, and Patch2self. The improvements were even pronounced in the following quantification results from the denoised images.Conclusion: The proposed MD‐S2S (Multidimensional‐Self2Self) denoising technique could be further applied to various multi‐dimensional MRI data and improve the quantification accuracy of tissue parameter maps.
- 28 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (1) , 28-42
Unsupervised motion artifact correction of turbo spin‐echo MRI using deep image prior
Purpose: In MRI, motion artifacts can significantly degrade image quality. Motion artifact correction methods using deep neural networks usually required extensive training on large datasets, making them time‐consuming and resource‐intensive. In this paper, an unsupervised deep learning‐based motion artifact correction method for turbo‐spin echo MRI is proposed using the deep image prior framework.Theory and Methods: The proposed approach takes advantage of the high impedance to motion artifacts offered by the neural network parameterization to remove motion artifacts in MR images. The framework consists of parameterization of MR image, automatic spatial transformation, and motion simulation model. The proposed method synthesizes motion‐corrupted images from the motion‐corrected images generated by the convolutional neural network, where an optimization process minimizes the objective function between the synthesized images and the acquired images.Results: In the simulation study of 280 slices from 14 subjects, the proposed method showed a significant increase in the averaged structural similarity index measure by 0.2737 in individual coil images and by 0.4550 in the root‐sum‐of‐square images. In addition, the ablation study demonstrated the effectiveness of each proposed component in correcting motion artifacts compared to the corrected images produced by the baseline method. The experiments on real motion dataset has shown its clinical potential.Conclusion: The proposed method exhibited significant quantitative and qualitative improvements in correcting rigid and in‐plane motion artifacts in MR images acquired using turbo spin‐echo sequence.
- 28 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (1) , 28-42
Unsupervised motion artifact correction of turbo spin‐echo MRI using deep image prior
Purpose: In MRI, motion artifacts can significantly degrade image quality. Motion artifact correction methods using deep neural networks usually required extensive training on large datasets, making them time‐consuming and resource‐intensive. In this paper, an unsupervised deep learning‐based motion artifact correction method for turbo‐spin echo MRI is proposed using the deep image prior framework.Theory and Methods: The proposed approach takes advantage of the high impedance to motion artifacts offered by the neural network parameterization to remove motion artifacts in MR images. The framework consists of parameterization of MR image, automatic spatial transformation, and motion simulation model. The proposed method synthesizes motion‐corrupted images from the motion‐corrected images generated by the convolutional neural network, where an optimization process minimizes the objective function between the synthesized images and the acquired images.Results: In the simulation study of 280 slices from 14 subjects, the proposed method showed a significant increase in the averaged structural similarity index measure by 0.2737 in individual coil images and by 0.4550 in the root‐sum‐of‐square images. In addition, the ablation study demonstrated the effectiveness of each proposed component in correcting motion artifacts compared to the corrected images produced by the baseline method. The experiments on real motion dataset has shown its clinical potential.Conclusion: The proposed method exhibited significant quantitative and qualitative improvements in correcting rigid and in‐plane motion artifacts in MR images acquired using turbo spin‐echo sequence.
- 19 September 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (1) , 250-261
Registration and quantification network (RQnet) for IVIM‐DKI analysis in MRI
Purpose: A deep learning method is proposed for aligning diffusion weighted images (DWIs) and estimating intravoxel incoherent motion–diffusion kurtosis imaging parameters simultaneously.Methods: We propose an unsupervised deep learning method that performs 2 tasks: registration and quantification for intravoxel incoherent motion–diffusion kurtosis imaging analysis. A common registration method in diffusion MRI is based on minimizing dissimilarity between various DWIs, which may result in registration errors due to different contrasts in different DWIs.We designed a novel unsupervised deep learning method for both accurate registration and quantification of various diffusion parameters. In order to generate motion‐simulated training data and test data, 17 volunteers were scanned without moving their heads, and 4 volunteers moved their heads during the scan in a 3 Tesla MRI. In order to investigate the applicability of the proposed method to other organs, kidney images were also obtained. We compared the registration accuracy of the proposed method, statistical parametric mapping, and a deep learning method with a normalized cross‐correlation loss. In the quantification part of the proposed method, a deep learning method that considered the diffusion gradient direction was used.Results: Simulations and experimental results showed that the proposed method accurately performed registration and quantification for intravoxel incoherent motion–diffusion kurtosis imaging analysis. The registration accuracy of the proposed method was high for allbvalues. Furthermore, quantification performance was analyzed through simulations and in vivo experiments, where the proposed method showed the best performance among the compared methods.Conclusion: The proposed method aligns the DWIs and accurately quantifies the intravoxel incoherent motion–diffusion kurtosis imaging parameters.
- 19 September 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (1) , 250-261
Registration and quantification network (RQnet) for IVIM‐DKI analysis in MRI
Purpose: A deep learning method is proposed for aligning diffusion weighted images (DWIs) and estimating intravoxel incoherent motion–diffusion kurtosis imaging parameters simultaneously.Methods: We propose an unsupervised deep learning method that performs 2 tasks: registration and quantification for intravoxel incoherent motion–diffusion kurtosis imaging analysis. A common registration method in diffusion MRI is based on minimizing dissimilarity between various DWIs, which may result in registration errors due to different contrasts in different DWIs.We designed a novel unsupervised deep learning method for both accurate registration and quantification of various diffusion parameters. In order to generate motion‐simulated training data and test data, 17 volunteers were scanned without moving their heads, and 4 volunteers moved their heads during the scan in a 3 Tesla MRI. In order to investigate the applicability of the proposed method to other organs, kidney images were also obtained. We compared the registration accuracy of the proposed method, statistical parametric mapping, and a deep learning method with a normalized cross‐correlation loss. In the quantification part of the proposed method, a deep learning method that considered the diffusion gradient direction was used.Results: Simulations and experimental results showed that the proposed method accurately performed registration and quantification for intravoxel incoherent motion–diffusion kurtosis imaging analysis. The registration accuracy of the proposed method was high for allbvalues. Furthermore, quantification performance was analyzed through simulations and in vivo experiments, where the proposed method showed the best performance among the compared methods.Conclusion: The proposed method aligns the DWIs and accurately quantifies the intravoxel incoherent motion–diffusion kurtosis imaging parameters.
- 16 February 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (1) , 230-244
Quantification of intravoxel incoherent motion with optimized b‐values using deep neural network
Purpose: To develop a framework for quantifying intravoxel incoherent motion (IVIM) parameters, where a neural network for quantification and b‐values for diffusion‐weighted imaging are simultaneously optimized.Method: A deep neural network (DNN) method is proposed for accurate quantification of IVIM parameters from multiple diffusion‐weighted images. In addition, optimal b‐values are selected to acquire the multiple diffusion‐weighted images. The proposed framework consists of an MRI signal generation part and an IVIM parameter quantification part. Monte‐Carlo (MC) simulations were performed to evaluate the accuracy of the IVIM parameter quantification and the efficacy of b‐value optimization. In order to analyze the effect of noise on the optimized b‐values, simulations were performed with five different noise levels. For in vivo data, diffusion images were acquired with the b‐values from four b‐values selection methods for five healthy volunteers at 3T MRI system.Results: Experiment results showed that both the optimization of b‐values and the training of DNN were simultaneously performed to quantify IVIM parameters. We found that the accuracies of the perfusion coefficient (Dp) and perfusion fraction (f) were more sensitive to b‐values than the diffusion coefficient (D) was. Furthermore, when the noise level changed, the optimized b‐values also changed. Therefore, noise level has to be considered when optimizing b‐values for IVIM quantification.Conclusion: The proposed scheme can simultaneously optimize b‐values and train DNN to minimize quantification errors of IVIM parameters. The trained DNN can quantify IVIM parameters from the diffusion‐weighted images obtained with the optimized b‐values.
- 16 February 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (1) , 230-244
Quantification of intravoxel incoherent motion with optimized b‐values using deep neural network
Purpose: To develop a framework for quantifying intravoxel incoherent motion (IVIM) parameters, where a neural network for quantification and b‐values for diffusion‐weighted imaging are simultaneously optimized.Method: A deep neural network (DNN) method is proposed for accurate quantification of IVIM parameters from multiple diffusion‐weighted images. In addition, optimal b‐values are selected to acquire the multiple diffusion‐weighted images. The proposed framework consists of an MRI signal generation part and an IVIM parameter quantification part. Monte‐Carlo (MC) simulations were performed to evaluate the accuracy of the IVIM parameter quantification and the efficacy of b‐value optimization. In order to analyze the effect of noise on the optimized b‐values, simulations were performed with five different noise levels. For in vivo data, diffusion images were acquired with the b‐values from four b‐values selection methods for five healthy volunteers at 3T MRI system.Results: Experiment results showed that both the optimization of b‐values and the training of DNN were simultaneously performed to quantify IVIM parameters. We found that the accuracies of the perfusion coefficient (Dp) and perfusion fraction (f) were more sensitive to b‐values than the diffusion coefficient (D) was. Furthermore, when the noise level changed, the optimized b‐values also changed. Therefore, noise level has to be considered when optimizing b‐values for IVIM quantification.Conclusion: The proposed scheme can simultaneously optimize b‐values and train DNN to minimize quantification errors of IVIM parameters. The trained DNN can quantify IVIM parameters from the diffusion‐weighted images obtained with the optimized b‐values.