Hee Kwon Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hee Kwon Song has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Rong Zhou
University of Pennsylvania
3 shared publications - Stephen Pickup
Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
3 shared publications - Cynthia Clendenin
Pancreatic Cancer Research Center, University of Pennsylvania, Philadelphia, PA 19104, USA
2 shared publications - Jianbo Cao
Collaborative Innovation Center for Molecular Imaging of Precision Medicine Shanxi Medical University, Taiyuan, People’s Republic of China
2 shared publications - Mamta Gupta
University of Pennsylvania 1 Department of Radiology Philadelphia, Pennsylvania
2 shared publications - Mark A. Rosen
Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
2 shared publications
Latest Publications
- Open Access
- 24 August 2022
- Published by MDPI AG in Tomography
- Vol. 8 (5) , 2113-2128
Dynamic Contrast-Enhanced MRI in the Abdomen of Mice with High Temporal and Spatial Resolution Using Stack-of-Stars Sampling and KWIC Reconstruction
Application of quantitative dynamic contrast-enhanced (DCE) MRI in mouse models of abdominal cancer is challenging due to the effects of RF inhomogeneity, image corruption from rapid respiratory motion and the need for high spatial and temporal resolutions. Here we demonstrate a DCE protocol optimized for such applications. The method consists of three acquisitions: (1) actual flip-angle B1 mapping, (2) variable flip-angle T1 mapping and (3) acquisition of the DCE series using a motion-robust radial strategy with k-space weighted image contrast (KWIC) reconstruction. All three acquisitions employ spoiled radial imaging with stack-of-stars sampling (SoS) and golden-angle increments between the views. This scheme is shown to minimize artifacts due to respiratory motion while simultaneously facilitating view-sharing image reconstruction for the dynamic series. The method is demonstrated in a genetically engineered mouse model of pancreatic ductal adenocarcinoma and yielded mean perfusion parameters of Ktrans = 0.23 ± 0.14 min−1 and ve = 0.31 ± 0.17 (n = 22) over a wide range of tumor sizes. The SoS-sampled DCE method is shown to produce artifact-free images with good SNR leading to robust estimation of DCE parameters.
- 24 August 2022
- Published by MDPI AG in Tomography
- Vol. 8 (5) , 2113-2128
Open AccessDynamic Contrast-Enhanced MRI in the Abdomen of Mice with High Temporal and Spatial Resolution Using Stack-of-Stars Sampling and KWIC Reconstruction
Application of quantitative dynamic contrast-enhanced (DCE) MRI in mouse models of abdominal cancer is challenging due to the effects of RF inhomogeneity, image corruption from rapid respiratory motion and the need for high spatial and temporal resolutions. Here we demonstrate a DCE protocol optimized for such applications. The method consists of three acquisitions: (1) actual flip-angle B1 mapping, (2) variable flip-angle T1 mapping and (3) acquisition of the DCE series using a motion-robust radial strategy with k-space weighted image contrast (KWIC) reconstruction. All three acquisitions employ spoiled radial imaging with stack-of-stars sampling (SoS) and golden-angle increments between the views. This scheme is shown to minimize artifacts due to respiratory motion while simultaneously facilitating view-sharing image reconstruction for the dynamic series. The method is demonstrated in a genetically engineered mouse model of pancreatic ductal adenocarcinoma and yielded mean perfusion parameters of Ktrans = 0.23 ± 0.14 min−1 and ve = 0.31 ± 0.17 (n = 22) over a wide range of tumor sizes. The SoS-sampled DCE method is shown to produce artifact-free images with good SNR leading to robust estimation of DCE parameters.
- Open Access
DWI Metrics Differentiating Benign Intraductal Papillary Mucinous Neoplasms from Invasive Pancreatic Cancer: A Study in GEM Models
KPC (KrasG12D:Trp53R172H:Pdx1-Cre) and CKS (KrasG12D:Smad4L/L:Ptf1a-Cre) mice are genetically engineered mouse (GEM) models that capture features of human pancreatic ductal adenocarcinoma (PDAC) and intraductal papillary mucinous neoplasms (IPMN), respectively. We compared these autochthonous tumors using quantitative imaging metrics from diffusion-weighted MRI (DW-MRI) and dynamic contrast enhanced (DCE)-MRI in reference to quantitative histological metrics including cell density, fibrosis, and microvasculature density. Our results revealed distinct DW-MRI metrics between the KPC vs. CKS model (mimicking human PDAC vs. IPMN lesion): the apparent diffusion coefficient (ADC) of CKS tumors is significantly higher than that of KPC, with little overlap (mean ± SD vs. , ) despite intratumor and intertumor variability. Kurtosis index (KI) is also distinctively separated in the two models. DW imaging metrics are consistent with growth pattern, cell density, and the cystic nature of the CKS tumors. Coregistration of ex vivo ADC maps with H&E-stained sections allowed for regional comparison and showed a correlation between local cell density and ADC value. In conclusion, studies in GEM models demonstrate the potential utility of diffusion-weighted MRI metrics for distinguishing pancreatic cancer from benign pancreatic cysts such as IPMN.Open AccessDWI Metrics Differentiating Benign Intraductal Papillary Mucinous Neoplasms from Invasive Pancreatic Cancer: A Study in GEM Models
KPC (KrasG12D:Trp53R172H:Pdx1-Cre) and CKS (KrasG12D:Smad4L/L:Ptf1a-Cre) mice are genetically engineered mouse (GEM) models that capture features of human pancreatic ductal adenocarcinoma (PDAC) and intraductal papillary mucinous neoplasms (IPMN), respectively. We compared these autochthonous tumors using quantitative imaging metrics from diffusion-weighted MRI (DW-MRI) and dynamic contrast enhanced (DCE)-MRI in reference to quantitative histological metrics including cell density, fibrosis, and microvasculature density. Our results revealed distinct DW-MRI metrics between the KPC vs. CKS model (mimicking human PDAC vs. IPMN lesion): the apparent diffusion coefficient (ADC) of CKS tumors is significantly higher than that of KPC, with little overlap (mean ± SD vs. , ) despite intratumor and intertumor variability. Kurtosis index (KI) is also distinctively separated in the two models. DW imaging metrics are consistent with growth pattern, cell density, and the cystic nature of the CKS tumors. Coregistration of ex vivo ADC maps with H&E-stained sections allowed for regional comparison and showed a correlation between local cell density and ADC value. In conclusion, studies in GEM models demonstrate the potential utility of diffusion-weighted MRI metrics for distinguishing pancreatic cancer from benign pancreatic cysts such as IPMN. - Open Access
- 20 February 2021
- Published by MDPI AG in Tomography
- Vol. 7 (1) , 66-79
Respiratory Motion Mitigation and Repeatability of Two Diffusion-Weighted MRI Methods Applied to a Murine Model of Spontaneous Pancreatic Cancer
Respiratory motion and increased susceptibility effects at high magnetic fields pose challenges for quantitative diffusion-weighted MRI (DWI) of a mouse abdomen on preclinical MRI systems. We demonstrate the first application of radial k-space-sampled (RAD) DWI of a mouse abdomen using a genetically engineered mouse model of pancreatic ductal adenocarcinoma (PDAC) on a 4.7 T preclinical scanner equipped with moderate gradient capability. RAD DWI was compared with the echo-planar imaging (EPI)-based DWI method with similar voxel volumes and acquisition times over a wide range of b-values (0.64, 535, 1071, 1478, and 2141 mm2/s). The repeatability metrics are assessed in a rigorous test–retest study (n = 10 for each DWI protocol). The four-shot EPI DWI protocol leads to higher signal-to-noise ratio (SNR) in diffusion-weighted images with persisting ghosting artifacts, whereas the RAD DWI protocol produces relatively artifact-free images over all b-values examined. Despite different degrees of motion mitigation, both RAD DWI and EPI DWI allow parametric maps of apparent diffusion coefficients (ADC) to be produced, and the ADC of the PDAC tumor estimated by the two methods are 1.3 ± 0.24 and 1.5 ± 0.28 × 10−3 mm2/s, respectively (p = 0.075, n = 10), and those of a water phantom are 3.2 ± 0.29 and 2.8 ± 0.15 × 10−3 mm2/s, respectively (p = 0.001, n = 10). Bland-Altman plots and probability density function reveal good repeatability for both protocols, whose repeatability metrics do not differ significantly. In conclusion, RAD DWI enables a more effective respiratory motion mitigation but lower SNR, while the performance of EPI DWI is expected to improve with more advanced gradient hardware.
- 20 February 2021
- Published by MDPI AG in Tomography
- Vol. 7 (1) , 66-79
Open AccessRespiratory Motion Mitigation and Repeatability of Two Diffusion-Weighted MRI Methods Applied to a Murine Model of Spontaneous Pancreatic Cancer
Respiratory motion and increased susceptibility effects at high magnetic fields pose challenges for quantitative diffusion-weighted MRI (DWI) of a mouse abdomen on preclinical MRI systems. We demonstrate the first application of radial k-space-sampled (RAD) DWI of a mouse abdomen using a genetically engineered mouse model of pancreatic ductal adenocarcinoma (PDAC) on a 4.7 T preclinical scanner equipped with moderate gradient capability. RAD DWI was compared with the echo-planar imaging (EPI)-based DWI method with similar voxel volumes and acquisition times over a wide range of b-values (0.64, 535, 1071, 1478, and 2141 mm2/s). The repeatability metrics are assessed in a rigorous test–retest study (n = 10 for each DWI protocol). The four-shot EPI DWI protocol leads to higher signal-to-noise ratio (SNR) in diffusion-weighted images with persisting ghosting artifacts, whereas the RAD DWI protocol produces relatively artifact-free images over all b-values examined. Despite different degrees of motion mitigation, both RAD DWI and EPI DWI allow parametric maps of apparent diffusion coefficients (ADC) to be produced, and the ADC of the PDAC tumor estimated by the two methods are 1.3 ± 0.24 and 1.5 ± 0.28 × 10−3 mm2/s, respectively (p = 0.075, n = 10), and those of a water phantom are 3.2 ± 0.29 and 2.8 ± 0.15 × 10−3 mm2/s, respectively (p = 0.001, n = 10). Bland-Altman plots and probability density function reveal good repeatability for both protocols, whose repeatability metrics do not differ significantly. In conclusion, RAD DWI enables a more effective respiratory motion mitigation but lower SNR, while the performance of EPI DWI is expected to improve with more advanced gradient hardware.