    Cable Insulation Defect Prediction Based on Harmonic Anomaly Feature Analysis

    by Yuli Wang, Haisong Xu, Anzhe Wang, Kaiwen Huang, Ge Wang, Xu Lu, Daning Zhang

    With the increasing demand for power supply reliability, online monitoring techniques for cable health condition assessments are gaining more attention. Most prevailing techniques lack the sensitivity needed to detect minor insulation defects. A new monitoring technique based on the harmonic anomaly feature analysis of the shield-to-ground current is introduced in this paper. The sensor installation and data acquisition are convenient and intrinsically safe, which makes it a preferred online monitoring technique. This study focuses on the single-core 10 kV distribution cable type. The research work includes the theoretical analysis of the cable defect’s impact on the current harmonic features, which are then demonstrated by simulation and lab experiments. It has been found that cable insulation defects cause magnetic field distortion, which introduces various harmonic current components, principally, the third-, fifth-, and seventh-order harmonic. The harmonic anomaly features are load current-, defect type-, and aging time-dependent. The K-means algorithm was selected as the data analysis algorithm and was used to achieve insulation defect prediction. The research outcome establishes a solid basis for the field application of the shield-to-ground harmonic current monitoring technique.


  • Open Access

    Effect of Temperature and Thermal Ageing of Cable Silicone Rubber Accessories on Interface Pressure of Cable Joints

    by Rong Xia, Benhong Ouyang, Yuli Wang, Jianjun Yuan, Kaiwen Huang, Chunhua Fang, Yanhui Wang

    The adequate interfacial pressure of silicone rubber in cable intermediate joints is a basic condition to ensure the normal operation of cable joints, while high temperature and ageing in the operation of actual cables and accessories would affect the magnitude of interfacial pressure. The uniaxial tensile force of two different silicone rubbers for 10 kV cold-shrink joints at different temperatures and thermal ageing times was measured by experiment, and the Yeoh rubber intrinsic structure model was fitted according to the measured data. The material model was embedded into a two-dimensional axisymmetric finite element simulation model of the structure, and the relationship between the interference, temperature, thermal ageing time and interfacial pressure was investigated. The results show that the interfacial pressure increases linearly with the increase in interference. At the same interference, the interfacial pressure at the root of insulating silicone rubber and semiconducting silicone rubber increased by 9.1%, 12.3%, 6.4% and 9.2%, 16.3%, 5.6%, respectively, at 50, 75, and 100 °C compared with room temperature, and the largest interfacial pressure of cable joints was at 75 °C. Using the established ageing life prediction model based on the Arrhenius principle, the service life of the accessories was predicted to be 28.9 years at 90 °C of operating temperature and interfacial pressure greater than 55% of initial interfacial pressure.


  • Open Access

    A Novel Fault Location Method for Power Cables Based on an Unsupervised Learning Algorithm

    by Mingzhen Li, Jialong Bu, Yupeng Song, Zhongyi Pu, Yuli Wang, Cheng Xie

    In order to locate the short-circuit fault in power cable systems accurately and in a timely manner, a novel fault location method based on traveling waves is proposed, which has been improved by unsupervised learning algorithms. There are three main steps of the method: (1) build a matrix of the traveling waves associated with the sheath currents of the cables; (2) cluster the data in the matrix according to its density level and the stability, using Hierarchical Density-Based Spatial Clustering of Applications with Noise (HDBSCAN); (3) search for the characteristic cluster point(s) of the two branch clusters with the smallest density level to identify the arrival time of the traveling wave. The main improvement is that high-dimensional data can be directly used for the clustering, making the method more effective and accurate. A Power System Computer Aided Design (PSCAD) simulation has been carried out for typical power cable circuits. The results indicate that the hierarchical structure of the condensed cluster tree corresponds exactly to the location relationship between the fault point and the monitoring point. The proposed method can be used for the identification of the arrival time of the traveling wave.