AAAndrea Amarossi

Andrea Amarossi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrea Amarossi has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Accuracy and Early Outcomes of Patient-Specific TKA Using Inertial-Based Cutting Guides: A Pilot Study

    by Gianluca Piovan, Andrea Amarossi, Luca Bertolino, Elena Bardi, Alberto Favaro, Lorenzo Povegliano, Daniele Screpis, Francesco Iacono, Tommaso Bonanzinga

    Background and objectives: Patient-specific components (PSC) represent an innovative option for total knee arthroplasty (TKA) in advanced osteoarthritis. Their effectiveness, however, closely relies on accurate positioning. Our study investigates the accuracy achieved by means of an inertial-based extramedullary cutting guide and the postoperative clinical and radiographic outcomes. Methods and materials: This was a prospective, single-arm, pilot study involving patients undergoing primary TKA with YourKneeTM PSC. Femoral and tibial bone resections were performed using the Perseus inertial-based extramedullary cutting guide. Postoperative mechanical alignment and component positioning were assessed by computed tomography. Clinical outcomes were evaluated preoperatively and at 1, 3, 6, and 12 months postoperatively by main knee function and clinical outcome measures. Results: The study population included a small cohort (n= 12, four females/eight males, mean age 69 ± 5.65 years, mean BMI 25.7 ± 3.8 kg/m2, KL grade > 3) with no control group. The mean absolute error between the planned and obtained Hip–Knee–Ankle angle was 1.36° ± 1.06 and within ±3° of all cases. Mean coronal alignment error was 1.87° ± 0.87 and 1.67° ± 0.75 for the femoral and tibial components, respectively. The mean sagittal alignment error was 1.89° ± 1.24 and 2.45° ± 0.87 for the femoral and the tibial components, respectively. Patients showed significant improvement in clinical and functional scores within the first 6 months: OKS increased from 20.64 ± 2.77 at the preoperative screening to 42.27 ± 4.34 (p < 0.0001), total KSS rose from 90.64 ± 17.25 to 169.36 ± 23.57 (p < 0.0001), and FJS reached 85.09 ± 17.14 at 6 months (p = 0.0031), indicating excellent functional recovery and forgotten joint effect. Knee ROM improved from 90.91° ± 11.14 to 110.36° ± 8.44 (p < 0.0001). After 6 months, outcome scores plateaued, suggesting an early stabilization of clinical benefits. No signs of radiolucency were detected on X-rays at 3- and 12-month follow-ups. Conclusions: The Perseus inertial-based extramedullary cutting guide used in combination with the YourKneeTM PSCs resulted in accurate intraoperative prosthesis positioning and significant improvements in clinical and functional outcomes at 6 months after surgery. Despite the small sample size and absence of a control group, the results suggest that such combination represents a viable option to conventional surgical instrumentation and current off-the-shelf prosthetic designs.

  • Open Access

    Saving the Meniscus: A Retrospective Observational Study of the Incidence, Treatment, and Failure Rate of the Main Meniscal Tear Types at 24-Month Follow-Up

    by Daniele Screpis, Fjorela Qordja, Luca De Berardinis, Gianluca Piovan, Stefano Magnanelli, Andrea Amarossi, Antonio Pompilio Gigante, Claudio Zorzi

    Background: Despite advances in repair techniques, the failure rates of meniscal surgery are still high. The seven most common tear types—horizontal cleavage tears (HCTs), radial tears (RTs), meniscal ramp lesions (MRLs), meniscal root tears (MRTs), longitudinal tears (LTs), bucket-handle tears (BHMTs), and complex meniscal tears (CMTs)—were reviewed. The present retrospective observational study aimed to analyze their characteristics, incidence, treatment approach and failure rates of a consecutive cohort of patients undergoing meniscal arthroscopic repair. Methods: The database of a high-volume meniscal suture center was examined for lesions managed by all-inside, inside-out, outside-in, or transtibial pull-out techniques from January 2018 to September 2022. Demographic (gender, age at surgery, laterality of the affected knee) and intraoperative data (tear type/site, repair technique, and suture number/combination) were collected in order to calculate the failure rates of the cohort and of each tear type and suture technique. Results: Altogether, 636 procedures met our criteria of having at least a 2-year follow-up. The overall failure rate was 1.98%. The most frequent lesions were HCTs (41.98%), with most injuries being in the body/posterior horn (88.52%) of the right knee (56.92%). Treatment predominantly (92.50%) included all-inside sutures. All-inside repair had the highest failure rate (2.98%), followed by inside-out (1.56%) repair (p = 1.0), whereas outside-in and pull-out techniques never failed. Failure rates by lesion included BHMTs (7.27%), HCTs (2.25%), CMTs (1.49%), and LTs (1.25%); RMT, RML, and MRT repair were always successful. Conclusions: Findings at two years suggest that 1–3 all-inside sutures minimize MRL failure, whereas three or more all-inside sutures or combined techniques seem to be effective for HCTs, LTs, and RTs but not BHMTs. Pull-out repair worked best for complete tears/avulsion types of MRTs, whereas all-inside sutures effectively managed partial lesions. Results for CMTs were inconclusive.


  • Short-term clinical and radiological comparisons between two Medial Pivot Total Knee Arthroplasty implants with different geometries.

    by Eugenio Vecchini, Ramazzini Leandro, Enrico Lunardelli, Fabio Zancanaro, Andrea Amarossi, Angela Anselmi, Damiano De Cristan, Tommaso Maluta, Bruno Magnan, Matteo Ricci

    Different total knee arthroplasty (TKA) implants were created for the treatment of severe symptomatic gonarthrosis and Medial Pivot TKA (MP TKA) seem to reproduce the normal kinematics of the knee. We compare two different prosthetic designs of MP TKA in order to identify whether there is a difference between the two in terms of degree of patient satisfaction. Methods: A total of 89 patients were analyzed. A group of 46 patients who benefited from a TKA with the Evolution® prosthesis and one of 43 patients who received a TKA with the Persona® prosthesis. KSS, OKS, FJS and the ROM were analyzed at follow up. The values of KSS and OKS were similar between the two groups (p>0,05). Our statistical analysis revealed a statistically significant increase (p <0.05) in ROM in the Persona® group and in FJS in the Evolution® group. No radiolucent lines were observed in both groups at the radiological final follow-up. Conclusions: MP TKA models analysed are a valuable tool to achieve satisfactory clinical outcomes. This study demonstrates that the FJS is an important score for the evaluation of patient's satisfaction: a ROM's limitation can be accepted by the patient in exchange for a more natural perceived knee.


  • Open Access

    Posterior spine fusion in a Jehovah's Witness patient with severe rigid idiopathic scoliosis – A case report

    by Michele Da Broi, Andrea Amarossi, Mauro Spina, Torstein R. Meling, Massimo Balsano


  • Can treatment of posterior malleolus fractures with tibio-fibular instability be usefully addressed by Bartonicek classification?

    by T. Maluta, E.M. Samaila, A. Amarossi, A. Dorigotti, M. Ricci, E. Vecchini, B. Magnan


  • Open Access

    Could direct transdeltoid approach to severely displaced proximal humerus fracture be advantageous for a better reduction?

    by Tommaso Maluta, Andrea Amarossi, Manuel De Masi, Andrea Dorigotti, Matteo Ricci, Eugenio Vecchini, Stefano Negri, Elena Manuela Samaila, Bruno Magnan

    Surgical treatment of proximal humeral fractures (PHF) is a challenge for orthopaedic surgeons. Despite the wide application of open reduction and internal fixation with locking plates, the optimal surgical approach of PHF is still debated. This study aims to evaluate the radiological outcomes, defined as anatomical restoration of the greater tuberosity and humeral head-shaft angle, of the deltopectoral (DPA) and the lateral transdeltoid (LTA) approaches in three- and four-part PHF, treated with locking plate. This retrospective series review identifies 74 PHF surgically treated between January 2012 and December 2019. Patients were divided into two groups according to the surgical approach (DPA vs LTA). Demographic data, duration of surgery, radiological pre- and post-surgery parameters (greater tuberosity displacement and humeral head-shaft angle) were collected. The association between the surgical approach and the quality of fractures reduction was assessed. The use of LTA approach correlates with a better reduction of greater tuberosity displacements compare to DPA (63% in DPA vs 100% LTA). No significant association was found with the humeral head-shaft angle (restored in 89% of the patients in DPA and 86% in LTA group), and surgical times (range 40 - 210 minutes ± DS 33,56 for the DPA; range 45 - 170 minutes ± 29,60 for LTA). Conclusions: The results of this radiological study suggest that PHF with significant displacement of the grater tuberosity could benefit from the adoption of a lateral transdeltoid approach for the ORIF procedure. Further studies are needed to confirm these findings. (www.actabiomedica.it)


  • Open Access

    Impalement injuries of the shoulder: a case report with literature review.

    by Marco Scaglia, Stefano Negri, Gianmarco Pellizzari, Andrea Amarossi, Davide Pasquetto, Elena Samaila, Tommaso Maluta, Eugenio Vecchini, Matteo Ricci, Roberto Valentini, et al.

    The management of penetrating skeletal extremity trauma is a clinical challenge even for experienced surgeons. While the treatment of associated vascular injuries should be prioritized, there is still a lack of evidence regarding the management of foreign bodies in case of bone fractures or neurological injuries. Here we present a case of impalement of the right proximal humerus with a construction steel rod. The 54-year-old man was successfully treated without vascular, neurological, and thoracic sequelae. A review of the current literature about the most appropriate extrication sequences and soft tissue reconstruction following massive foreign body injuries was carried out.


    • 30 December 2020
      • Vol. 91  (Suppl 14) , e2020017
    Open Access

    External fixation for proximal humerus fractures neer type 3 and 4: results of 17 cases

    by Tommaso Maluta, Andrea Amarossi, Andrea Dorigotti, Francesco Bagnis, Elena Manuela Samaila, Lapo De Luca, Lorenzo Pezzè, Bruno Magnan

    Proximal humeral fractures (PHF) account for 4-6% of all fractures and 25% of humeral fractures. While conservative treatment is the gold standard for simple fractures, there is no consensus about the best treatment choice for complex PHF in the elderly. Recently a new external fixator was introduced in clinical practice for treatment of complex PHF. Aim of the study was to evaluate the functional results of this therapeutic approach. Data were retrospectively analyzed. Inclusion criteria were: three- and four-part PHF according to Neer, treatment with closed reduction and external fixation, normal Abbreviated Mini Mental Test score, independence in the daily living, non-pathological fracture, glenohumeral joint with moderate osteoarthritic changes and availability of clinical and radiological follow-up. For each patient demographic data, comorbidities, surgery time and estimated blood loss were recorded. Clinical and radiological evaluation were performed at 1, 2, 6, 12 months. 17 patients were enrolled. Mean age was 69.7 years. Fractures were classified according to Neer as type III in 10 cases and type IV in 7 cases. The mean operating time was 22 minutes. Mean Constant score value at follow up was 74 ± 11,52 at 2 months, 82 ± 11,16 at 6 months and 85 ± 9,86 at 12 months. These preliminary results show that the studied system is easy to use, minimally invasive, effective in reducing surgical and hospitalization time. The results in terms of functional recovery are encouraging, showing a reduced number of complications. (www.actabiomedica.it)