Ewan Gray
Research Subjects
Ewan Gray has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Mark G. Hegarty
Dxcover Ltd., Glasgow, United Kingdom
2 shared publications- Alexandra Sala
University of Strathclyde, Glasgow, United Kingdom
1 shared publication - Benjamin R. Smith
Dxcover Ltd., Glasgow, United Kingdom
1 shared publication - Daniel A. Orringer
Department of Neurosurgery, NYU Langone Health, New York, New York
1 shared publication David S. Palmer
University of Strathclyde
1 shared publication- David S. Palmer
Department of Pure and Applied Chemistry, University of Strathclyde, Thomas Graham Building, 295 Cathedral Street, Glasgow G1 1XL, U.K.
1 shared publication
Latest Publications
- Open Access
- 15 June 2022
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 82 (12_Supplem) , 5922
Abstract 5922: Clinical validation of a spectroscopic liquid biopsy for early detection of brain cancer
Diagnostic delays impact the quality of life and survival of patients with brain tumors. Earlier and expeditious diagnoses in these patients are crucial to reducing the morbidities and mortalities associated with brain tumors. A simple, rapid blood test that can be administered easily in a primary care setting to efficiently identify symptomatic patients who are most likely to have a brain tumor would enable quicker referral to brain imaging for those who need it most. Blood serum samples from 603 patients were prospectively collected and analyzed. Patients either had non-specific symptoms that could be indicative of a brain tumor on presentation to the Emergency Department, or a new brain tumor diagnosis and referral to the neurosurgical unit, NHS Lothian, Scotland. Patient blood serum samples were analyzed using the Dxcover® Brain Cancer liquid biopsy. This technology utilizes infrared spectroscopy combined with a diagnostic algorithm to predict the presence of intracranial disease. Our liquid biopsy approach reported an area under the receiver operating characteristic curve of 0.8. The sensitivity-tuned model achieves a 96% sensitivity with 45% specificity (NPV 99.3%) and identified 100% of glioblastoma multiforme patients. When tuned for a higher specificity, the model yields sensitivity of 47% with 90% specificity (PPV 28.4%). This simple, non-invasive blood test facilitates the triage and radiographic diagnosis of brain tumor patients, while providing reassurance to healthy patients. Minimizing time to diagnosis would facilitate identification of brain tumor patients at an earlier stage, enabling more effective, less morbid surgical and adjuvant care. Citation Format: James M. Cameron, Paul M. Brennan, Georgios Antoniou, Holly J. Butler, Loren Christie, Justin J.A. Conn, Tom Curran, Ewan Gray, Mark G. Hegarty, Michael Jenkinson, Daniel Orringer, David S. Palmer, Alexandra Sala, Benjamin R. Smith, Matthew J. Baker. Clinical validation of a spectroscopic liquid biopsy for early detection of brain cancer [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2022; 2022 Apr 8-13. Philadelphia (PA): AACR; Cancer Res 2022;82(12_Suppl):Abstract nr 5922.
- 15 June 2022
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 82 (12_Supplem) , 5922
Open AccessAbstract 5922: Clinical validation of a spectroscopic liquid biopsy for early detection of brain cancer
Diagnostic delays impact the quality of life and survival of patients with brain tumors. Earlier and expeditious diagnoses in these patients are crucial to reducing the morbidities and mortalities associated with brain tumors. A simple, rapid blood test that can be administered easily in a primary care setting to efficiently identify symptomatic patients who are most likely to have a brain tumor would enable quicker referral to brain imaging for those who need it most. Blood serum samples from 603 patients were prospectively collected and analyzed. Patients either had non-specific symptoms that could be indicative of a brain tumor on presentation to the Emergency Department, or a new brain tumor diagnosis and referral to the neurosurgical unit, NHS Lothian, Scotland. Patient blood serum samples were analyzed using the Dxcover® Brain Cancer liquid biopsy. This technology utilizes infrared spectroscopy combined with a diagnostic algorithm to predict the presence of intracranial disease. Our liquid biopsy approach reported an area under the receiver operating characteristic curve of 0.8. The sensitivity-tuned model achieves a 96% sensitivity with 45% specificity (NPV 99.3%) and identified 100% of glioblastoma multiforme patients. When tuned for a higher specificity, the model yields sensitivity of 47% with 90% specificity (PPV 28.4%). This simple, non-invasive blood test facilitates the triage and radiographic diagnosis of brain tumor patients, while providing reassurance to healthy patients. Minimizing time to diagnosis would facilitate identification of brain tumor patients at an earlier stage, enabling more effective, less morbid surgical and adjuvant care. Citation Format: James M. Cameron, Paul M. Brennan, Georgios Antoniou, Holly J. Butler, Loren Christie, Justin J.A. Conn, Tom Curran, Ewan Gray, Mark G. Hegarty, Michael Jenkinson, Daniel Orringer, David S. Palmer, Alexandra Sala, Benjamin R. Smith, Matthew J. Baker. Clinical validation of a spectroscopic liquid biopsy for early detection of brain cancer [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2022; 2022 Apr 8-13. Philadelphia (PA): AACR; Cancer Res 2022;82(12_Suppl):Abstract nr 5922.
- Open Access
- 24 February 2021
- Published by Cambridge University Press (CUP) in International Journal of Technology Assessment in Health Care
- Vol. 37 (1) , e41
Early economic evaluation to guide the development of a spectroscopic liquid biopsy for the detection of brain cancer
Objectives: An early economic evaluation to inform the translation into clinical practice of a spectroscopic liquid biopsy for the detection of brain cancer. Two specific aims are (1) to update an existing economic model with results from a prospective study of diagnostic accuracy and (2) to explore the potential of brain tumor-type predictions to affect patient outcomes and healthcare costs. Methods: A cost-effectiveness analysis from a UK NHS perspective of the use of spectroscopic liquid biopsy in primary and secondary care settings, as well as a cost–consequence analysis of the addition of tumor-type predictions was conducted. Decision tree models were constructed to represent simplified diagnostic pathways. Test diagnostic accuracy parameters were based on a prospective validation study. Four price points (GBP 50-200, EUR 57-228) for the test were considered. Results: In both settings, the use of liquid biopsy produced QALY gains. In primary care, at test costs below GBP 100 (EUR 114), testing was cost saving. At GBP 100 (EUR 114) per test, the ICER was GBP 13,279 (EUR 15,145), whereas at GBP 200 (EUR 228), the ICER was GBP 78,300 (EUR 89,301). In secondary care, the ICER ranged from GBP 11,360 (EUR 12,956) to GBP 43,870 (EUR 50,034) across the range of test costs. Conclusions: The results demonstrate the potential for the technology to be cost-effective in both primary and secondary care settings. Additional studies of test use in routine primary care practice are needed to resolve the remaining issues of uncertainty—prevalence in this patient population and referral behavior.
- 24 February 2021
- Published by Cambridge University Press (CUP) in International Journal of Technology Assessment in Health Care
- Vol. 37 (1) , e41
Open AccessEarly economic evaluation to guide the development of a spectroscopic liquid biopsy for the detection of brain cancer
Objectives: An early economic evaluation to inform the translation into clinical practice of a spectroscopic liquid biopsy for the detection of brain cancer. Two specific aims are (1) to update an existing economic model with results from a prospective study of diagnostic accuracy and (2) to explore the potential of brain tumor-type predictions to affect patient outcomes and healthcare costs. Methods: A cost-effectiveness analysis from a UK NHS perspective of the use of spectroscopic liquid biopsy in primary and secondary care settings, as well as a cost–consequence analysis of the addition of tumor-type predictions was conducted. Decision tree models were constructed to represent simplified diagnostic pathways. Test diagnostic accuracy parameters were based on a prospective validation study. Four price points (GBP 50-200, EUR 57-228) for the test were considered. Results: In both settings, the use of liquid biopsy produced QALY gains. In primary care, at test costs below GBP 100 (EUR 114), testing was cost saving. At GBP 100 (EUR 114) per test, the ICER was GBP 13,279 (EUR 15,145), whereas at GBP 200 (EUR 228), the ICER was GBP 78,300 (EUR 89,301). In secondary care, the ICER ranged from GBP 11,360 (EUR 12,956) to GBP 43,870 (EUR 50,034) across the range of test costs. Conclusions: The results demonstrate the potential for the technology to be cost-effective in both primary and secondary care settings. Additional studies of test use in routine primary care practice are needed to resolve the remaining issues of uncertainty—prevalence in this patient population and referral behavior.