Jieli He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jieli He has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Mei Chen
West Yunnan University of Applied Sciences, School of Health Science and Technology Dali, 671000, Yunnan, China
3 shared publicationsPeng Jin
Yunnan Provincial Key Laboratory of Entomological Biopharmaceutical R&D, College of Pharmacy, Dali University, Dali 671000, Yunnan, PR China
3 shared publicationsRuining Bai
Yunnan Provincial Key Laboratory of Entomological Biopharmaceutical R&D, College of Pharmacy, Dali University, Dali 671000, Yunnan, PR China
3 shared publicationsZhouhong Tan
3 shared publicationsAnzhong Peng
2 shared publications- Anzhong Peng
College of Pharmacy, Dali University, Dali, China
2 shared publications
Latest Publications
- 10 August 2026
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 103 (9) , 4817-4827
Design and Evaluation of Personalized Learning Pathways Based on OBE Principles: A Case Study of Physical Chemistry
The integration of OBE principles into the Physical Chemistry curriculum signifies a shift from merely covering subject knowledge points to achieving multidimensional learning outcomes. To meet contemporary educational demands, constructing personalized learning pathways is crucial for enabling students to explore core disciplinary concepts while enhancing their higher-order thinking skills and comprehensive competencies. This study developed an OBE-based personalized learning pathway model centered on four key modules: goal decomposition, pathway generation, dynamic adjustment, and effectiveness evaluation. The model is implemented through a cyclical process spanning three phases: preclass, in-class, and postclass. The study involved 242 third-year chemistry majors using a mixed-methods approach, embedding quantitative data collection and personalized learning model validation within course design. These findings suggest that students in the experimental condition achieved higher academic performance and self-efficacy. They further demonstrated that under OBE-guided personalized learning pathways, enhancing self-efficacy and reducing cognitive load are two parallel and equally important objectives.
- 10 August 2026
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 103 (9) , 4817-4827
Design and Evaluation of Personalized Learning Pathways Based on OBE Principles: A Case Study of Physical Chemistry
The integration of OBE principles into the Physical Chemistry curriculum signifies a shift from merely covering subject knowledge points to achieving multidimensional learning outcomes. To meet contemporary educational demands, constructing personalized learning pathways is crucial for enabling students to explore core disciplinary concepts while enhancing their higher-order thinking skills and comprehensive competencies. This study developed an OBE-based personalized learning pathway model centered on four key modules: goal decomposition, pathway generation, dynamic adjustment, and effectiveness evaluation. The model is implemented through a cyclical process spanning three phases: preclass, in-class, and postclass. The study involved 242 third-year chemistry majors using a mixed-methods approach, embedding quantitative data collection and personalized learning model validation within course design. These findings suggest that students in the experimental condition achieved higher academic performance and self-efficacy. They further demonstrated that under OBE-guided personalized learning pathways, enhancing self-efficacy and reducing cognitive load are two parallel and equally important objectives.
- 16 March 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (12) , 2538-2547
Rapid and sensitive fluorescence detection of clozapine via g-C 3 N 4 nanosheet-based quenching
A highly sensitive g-C 3 N 4 nanosheet-based fluorescent sensor for clozapine detection via charge-transfer quenching, enabling rapid therapeutic drug monitoring with a wide linear range of 0.02–500 µM and a detection limit of 3 nM.
- 16 March 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (12) , 2538-2547
Rapid and sensitive fluorescence detection of clozapine via g-C 3 N 4 nanosheet-based quenching
A highly sensitive g-C 3 N 4 nanosheet-based fluorescent sensor for clozapine detection via charge-transfer quenching, enabling rapid therapeutic drug monitoring with a wide linear range of 0.02–500 µM and a detection limit of 3 nM.
- 26 January 2026
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 352, 127528
“On–off–on” fluorescent probe based on g-C3N4 quantum dots for sequential detection of Ag+ and glutathione
- 26 January 2026
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 352, 127528
“On–off–on” fluorescent probe based on g-C3N4 quantum dots for sequential detection of Ag+ and glutathione
- Open Access
Highly Efficient Capture of Heavy Metal Ions on Amine-Functionalized Porous Polymer Gels
Porous polymer gels (PPGs) are characterized by inherent porosity, a predictable structure, and tunable functionality, which makes them promising for the heavy metal ion trap in environmental remediation. However, their real-world application is obstructed by the balance between performance and economy in material preparation. Development of an efficient and cost-effective approach to produce PPGs with task-specific functionality remains a significant challenge. Here, a two-step strategy to fabricate amine-enriched PPGs, NUT-21-TETA (NUT means Nanjing Tech University, TETA indicates triethylenetetramine), is reported for the first time. The NUT-21-TETA was synthesized through a simple nucleophilic substitution using two readily available and low-cost monomers, mesitylene and α, α′-dichloro-p-xylene, followed by the successful post-synthetic amine functionalization. The obtained NUT-21-TETA demonstrates an extremely high Pb2+ capacity from aqueous solution. The maximum Pb2+ capacity, qm, assessed by the Langmuir model was as high as 1211 mg/g, which is much higher than most benchmark adsorbents including ZIF-8 (1120 mg/g), FGO (842 mg/g), 732-CR resin (397 mg/g), Zeolite 13X (541 mg/g), and AC (58 mg/g). The NUT-21-TETA can be regenerated easily and recycled five times without a noticeable decrease of adsorption capacity. The excellent Pb2+ uptake and perfect reusability, in combination with a low synthesis cost, gives the NUT-21-TETA a strong potential for heavy metal ion removal.
Open AccessHighly Efficient Capture of Heavy Metal Ions on Amine-Functionalized Porous Polymer Gels
Porous polymer gels (PPGs) are characterized by inherent porosity, a predictable structure, and tunable functionality, which makes them promising for the heavy metal ion trap in environmental remediation. However, their real-world application is obstructed by the balance between performance and economy in material preparation. Development of an efficient and cost-effective approach to produce PPGs with task-specific functionality remains a significant challenge. Here, a two-step strategy to fabricate amine-enriched PPGs, NUT-21-TETA (NUT means Nanjing Tech University, TETA indicates triethylenetetramine), is reported for the first time. The NUT-21-TETA was synthesized through a simple nucleophilic substitution using two readily available and low-cost monomers, mesitylene and α, α′-dichloro-p-xylene, followed by the successful post-synthetic amine functionalization. The obtained NUT-21-TETA demonstrates an extremely high Pb2+ capacity from aqueous solution. The maximum Pb2+ capacity, qm, assessed by the Langmuir model was as high as 1211 mg/g, which is much higher than most benchmark adsorbents including ZIF-8 (1120 mg/g), FGO (842 mg/g), 732-CR resin (397 mg/g), Zeolite 13X (541 mg/g), and AC (58 mg/g). The NUT-21-TETA can be regenerated easily and recycled five times without a noticeable decrease of adsorption capacity. The excellent Pb2+ uptake and perfect reusability, in combination with a low synthesis cost, gives the NUT-21-TETA a strong potential for heavy metal ion removal.
- Open Access
- 16 September 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (41) , 26704-26711
Development and validation of the UPLC-MS method for simultaneous determination of six new psychoactive substances
The combined abuse of benzodiazepines and antipsychotics has become a global problem, and to develop a highly sensitive and selective method for monitoring of benzodiazepine hypnotics and antipsychotics is urgently necessary. In this work, we established a rapid method for the simultaneous determination of benzodiazepines (diazepam, alprazolam, triazolam, and estazolam) and antipsychotic drugs (clozapine, and chlorpromazine) based on ultra performance liquid chromatography-mass spectrometry (UPLC-MS). The accuracy, precision, limit of detection (LOD), limit of quantification (LOQ), specificity, matrix effect and carry-over effect were verified in detail. The results of the recovery and repeat experiments proved that the proposed UPLC-MS method possessed very satisfactory accuracy and precision. The LOD and LOQ of the six psychoactive substances were as low as 0.001–0.005 and 0.005–0.01 μg L−1, respectively. The proposed method was employed to analyze urine samples which were pretreated with a protein precipitation process. The potential influences of precipitants on the analysis results were evaluated statistically, and 0.1% formic acid/acetonitrile/water was selected as the optimum precipitation agent. The detection of the targets was free from matrix and carryover effects.
- 16 September 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (41) , 26704-26711
Open AccessDevelopment and validation of the UPLC-MS method for simultaneous determination of six new psychoactive substances
The combined abuse of benzodiazepines and antipsychotics has become a global problem, and to develop a highly sensitive and selective method for monitoring of benzodiazepine hypnotics and antipsychotics is urgently necessary. In this work, we established a rapid method for the simultaneous determination of benzodiazepines (diazepam, alprazolam, triazolam, and estazolam) and antipsychotic drugs (clozapine, and chlorpromazine) based on ultra performance liquid chromatography-mass spectrometry (UPLC-MS). The accuracy, precision, limit of detection (LOD), limit of quantification (LOQ), specificity, matrix effect and carry-over effect were verified in detail. The results of the recovery and repeat experiments proved that the proposed UPLC-MS method possessed very satisfactory accuracy and precision. The LOD and LOQ of the six psychoactive substances were as low as 0.001–0.005 and 0.005–0.01 μg L−1, respectively. The proposed method was employed to analyze urine samples which were pretreated with a protein precipitation process. The potential influences of precipitants on the analysis results were evaluated statistically, and 0.1% formic acid/acetonitrile/water was selected as the optimum precipitation agent. The detection of the targets was free from matrix and carryover effects.
- Open Access
- 16 July 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (40) , 24892-24899
Facile synthesis of carbon nitride quantum dots as a highly selective and sensitive fluorescent sensor for the tetracycline detection
The g-C 3 N 4 QDs were synthesized by a simple solvothermal “tailoring” process from bulk g-C 3 N 4 which have a “strong quenching” behaviour in the presence of TC. The proposed fluorescent sensor has been successfully applied to detect TC in actual samples.
- 16 July 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (40) , 24892-24899
Open AccessFacile synthesis of carbon nitride quantum dots as a highly selective and sensitive fluorescent sensor for the tetracycline detection
The g-C 3 N 4 QDs were synthesized by a simple solvothermal “tailoring” process from bulk g-C 3 N 4 which have a “strong quenching” behaviour in the presence of TC. The proposed fluorescent sensor has been successfully applied to detect TC in actual samples.
- Open Access
- 29 June 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (37) , 23002-23009
Development and comparison of UPLC-ESI-MS and RP-HPLC-VWD methods for determining microcystin-LR
Microcystin-LR (MC-LR) generated by cyanobacteria is a kind of potent hepatotoxin, which poses a considerable threat to human health. In the research field of MC-LR removal, the quantitative analysis in a wide concentration range of samples is inevitable. In this paper, we presented the pseudo united use of an Ultra Performance Liquid Chromatography Mass Spectrometry (UPLC-MS) and High Performance Liquid Chromatography system with a Variable Wavelength Ultraviolet Detector (HPLC-VWD) approach to detect MC-LR. The UPLC-MS system was applied to determine MC-LR in trace concentration because of its high sensitivity. However, it is generally believed that the determination of high concentration samples by UPLC-MS will cause problems such as inaccurate quantification and contamination of ion sources. In consequence, the HPLC-VWD was employed to determine the high concentration of MC-LR. The sensitivity, precision and accuracy of the two methods were compared in detail. The linear ranges of UPLC-MS and HPLC-VWD methods were from 0.08 to 10 μg L−1 and 1 to 5000 μg L−1, respectively. The detection and quantification limits of UPLC-MS were 0.03–0.05 μg L−1 and 0.08 μg L−1, and the corresponding two values of HPLC-VWD were 0.6 and 1.0 μg L−1. The recoveries of UPLC-MS and HPLC-VWD were 88.5–106.7% and 98.7–101.6%, with the relative standard deviations of 3.72–5.45% and 0.38–1.69%, respectively. The potential adsorption properties of MC-LR on filter membranes with diverse materials and pore sizes were evaluated and the negative results were obtained. The detection of MC-LR by UPLC-MS was free from matrix effects. The presented UPLC-MS and HPLC-VWD methods were used to analyze the water samples from Erhai Lake, which is located in Dali, Yunnan, China. The results of UPLC-MS analysis indicated that the MC-LR was only identified in water samples of Shuanglang Bay and Xier River, with concentrations of 0.120 and 0.303 μg L−1, whereas MC-LR was not detected by HPLC-VWD.
- 29 June 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (37) , 23002-23009
Open AccessDevelopment and comparison of UPLC-ESI-MS and RP-HPLC-VWD methods for determining microcystin-LR
Microcystin-LR (MC-LR) generated by cyanobacteria is a kind of potent hepatotoxin, which poses a considerable threat to human health. In the research field of MC-LR removal, the quantitative analysis in a wide concentration range of samples is inevitable. In this paper, we presented the pseudo united use of an Ultra Performance Liquid Chromatography Mass Spectrometry (UPLC-MS) and High Performance Liquid Chromatography system with a Variable Wavelength Ultraviolet Detector (HPLC-VWD) approach to detect MC-LR. The UPLC-MS system was applied to determine MC-LR in trace concentration because of its high sensitivity. However, it is generally believed that the determination of high concentration samples by UPLC-MS will cause problems such as inaccurate quantification and contamination of ion sources. In consequence, the HPLC-VWD was employed to determine the high concentration of MC-LR. The sensitivity, precision and accuracy of the two methods were compared in detail. The linear ranges of UPLC-MS and HPLC-VWD methods were from 0.08 to 10 μg L−1 and 1 to 5000 μg L−1, respectively. The detection and quantification limits of UPLC-MS were 0.03–0.05 μg L−1 and 0.08 μg L−1, and the corresponding two values of HPLC-VWD were 0.6 and 1.0 μg L−1. The recoveries of UPLC-MS and HPLC-VWD were 88.5–106.7% and 98.7–101.6%, with the relative standard deviations of 3.72–5.45% and 0.38–1.69%, respectively. The potential adsorption properties of MC-LR on filter membranes with diverse materials and pore sizes were evaluated and the negative results were obtained. The detection of MC-LR by UPLC-MS was free from matrix effects. The presented UPLC-MS and HPLC-VWD methods were used to analyze the water samples from Erhai Lake, which is located in Dali, Yunnan, China. The results of UPLC-MS analysis indicated that the MC-LR was only identified in water samples of Shuanglang Bay and Xier River, with concentrations of 0.120 and 0.303 μg L−1, whereas MC-LR was not detected by HPLC-VWD.
- 19 July 2019
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 30 (16) , 15257-15266
Synthesis of Zn2+ doped AgInxSy sub-microspheres and its visible light photocatalytic activity
- 19 July 2019
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 30 (16) , 15257-15266
Synthesis of Zn2+ doped AgInxSy sub-microspheres and its visible light photocatalytic activity