Fatma Sellami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Fatma Sellami has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Albera
Department of Surgical Sciences, University of Turin, Turin, Italy
1 shared publication - Anna Warzybok
Medizinische Physik, Carl von Ossietzky Universität Oldenburg
1 shared publication - Arianna Astolfi
Department of Energy, Politecnico di Torino, 10129 Turin, Italy
1 shared publication - Birger Kollmeier
Medizinische Physik and Cluster of Excellence Hearing4all, CvO Universität, Oldenburg, 26111, Oldenburg, Germany
1 shared publication - Carla Montuschi
Section of Otorhinolaryngology, Department of Surgery, Ospedale degli Infermi, 13875 Biella, Italy
1 shared publication - Diego Zanetti
Department of Clinical Sciences and Community Health, University of Milan, 20122 Milan, Italy
1 shared publication
Latest Publications
- Open Access
- 25 February 2021
- Published by MDPI AG in Audiology Research
- Vol. 11 (1) , 73-88
Evaluation of Italian Simplified Matrix Test for Speech-Recognition Measurements in Noise
This study aimed at the evaluation of a simplified Italian matrix test (SiIMax) for speech-recognition measurements in noise for adults and children. Speech-recognition measurements with adults and children were conducted to examine the training effect and to establish reference speech-recognition thresholds of 50% (SRT50) and 80% (SRT80) correct responses. Test-list equivalency was evaluated only with adults. Twenty adults and 96 children—aged between 5 and 10 years—participated. Evaluation measurements with the adults confirmed the equivalence of the test lists, with a mean SRT50 of −8.0 dB and a standard deviation of 0.2 dB across the test lists. The test-specific slope (the average of the list-specific slopes) was 11.3%/dB, with a standard deviation of 0.6%/dB. For both adults and children, only one test list of 14 phrases needs to be presented to account for the training effect. For the adults, adaptive measurements of the SRT50 and SRT80 showed mean values of −7.0 ± 0.6 and −4.5 ± 1.1 dB, respectively. For children, a slight influence of age on the SRT was observed. The mean SRT50s were −5.6 ± 1.2, −5.8 ± 1.2 and −6.6 ± 1.3 dB for the children aged 5–6, 7–8 and 9–10 years, respectively. The corresponding SRT80s were −1.5 ± 2.7, −3.0 ± 1.7 and −3.7 ± 1.4 dB. High test–retest reliabilities of 1.0 and 1.1 dB for the SRT80 were obtained for the adults and children, respectively. This makes the test suitable for accurate and reliable speech-recognition measurements.
- 25 February 2021
- Published by MDPI AG in Audiology Research
- Vol. 11 (1) , 73-88
Open AccessEvaluation of Italian Simplified Matrix Test for Speech-Recognition Measurements in Noise
This study aimed at the evaluation of a simplified Italian matrix test (SiIMax) for speech-recognition measurements in noise for adults and children. Speech-recognition measurements with adults and children were conducted to examine the training effect and to establish reference speech-recognition thresholds of 50% (SRT50) and 80% (SRT80) correct responses. Test-list equivalency was evaluated only with adults. Twenty adults and 96 children—aged between 5 and 10 years—participated. Evaluation measurements with the adults confirmed the equivalence of the test lists, with a mean SRT50 of −8.0 dB and a standard deviation of 0.2 dB across the test lists. The test-specific slope (the average of the list-specific slopes) was 11.3%/dB, with a standard deviation of 0.6%/dB. For both adults and children, only one test list of 14 phrases needs to be presented to account for the training effect. For the adults, adaptive measurements of the SRT50 and SRT80 showed mean values of −7.0 ± 0.6 and −4.5 ± 1.1 dB, respectively. For children, a slight influence of age on the SRT was observed. The mean SRT50s were −5.6 ± 1.2, −5.8 ± 1.2 and −6.6 ± 1.3 dB for the children aged 5–6, 7–8 and 9–10 years, respectively. The corresponding SRT80s were −1.5 ± 2.7, −3.0 ± 1.7 and −3.7 ± 1.4 dB. High test–retest reliabilities of 1.0 and 1.1 dB for the SRT80 were obtained for the adults and children, respectively. This makes the test suitable for accurate and reliable speech-recognition measurements.