  • Power Dependent Resonant Frequency of a Microwave Cavity Due to Magnetic Levitation

    by N. K. Raut, J. Miller, H. Hart, R. Chiao, J. E. Sharping

    The fact that a magnet levitates above a superconductor is a fascinating consequence of the interaction between electromagnetic fields and the macroscopic quantum state of the superconductor. Such field-matter interactions, which include the Meissner and Josephson effects, combined with superconducting devices, such as low-loss superconducting microwave cavities, are emerging as key elements used in quantum computers. One technique that can be used to monitor the levitation of a magnet is to place the magnet within a superconducting microwave cavity and monitor the microwave resonance of that cavity. Here, we report measurements of the change in resonance frequency of the microwave cavity with the Meissner-levitated permanent magnet. The cavity resonance changes because the magnet perturbs the radio-frequency field inside the microwave cavity. The changes in resonant frequency and quality factor were measured as functions of input power and temperature. The observed power-dependent variations are explained in terms of the power dependence of the London penetration depth.


  • Open Access

    Comparative Study of Magnetic Levitation Models

    by N. K. Raut, J. Miller, R. Y. Chiao, J. E. Sharping

    Levitation refers to free flotation, where the levitated object is suspended freely, against gravity without any physical contact. Among many levitation, magnetic levitation due to a finite-sized type-I superconductor was demonstrated and characterized. Here, we have developed a model by extending the two-loop method to calculate the levitation height for magnetic levitation within the superconducting microwave cavity and is compared with widely used mirror and finite-size superconductor method. The models were used to calculate the levitation height from the center and edge of the superconductor for magnet with strength 0.1 - 2.0 T. We observed a large discrepancy between the models for the edge levitation where our model underestimate the levitation height by 40-95%. Furthermore, in contrast to other models, our model has shown a superior capacity to calculate the levitation height at any location on the superconductor


  • Open Access

    Comparative study between three models for the levitation height calculation

    by Nabin K. Raut, Jeffery Miller, Raymond Y. Chiao, Jay E. Sharping

    Magnetic levitation has been demonstrated and characterized within the coaxial microwave cavity [1,2]. A permanent neodymium magnet is levitated from the edge of the finite-size superconductor [3,4]. One challenge is to develop a better method to calculate levitation height [5]. This paper compares three models, the Mirror method, finite-size superconductor, and two-loop model, for the levitation height calculation. The limitations and advantages of each model are discussed in detail.

  • Magnet Strength Dependence of Levitated Magnets in a Microwave Cavity

    by Nabin K. Raut, Jeffery Miller, Raymond Y. Chiao, Jay E. Sharping

    We report on the behavior of a superconducting microwave cavity containing levitated permanent magnets having a range of magnet strengths. By observing the changes in the cavity’s loaded quality factor and resonance frequency as functions of temperature and magnet remanence, we gain an understanding of the transient motion of the magnet as well as its steady-state levitation height when the temperature drops below 1 K. Experimental measurements of Meissner-effect levitation within a 10 GHz superconducting aluminum coaxial quarter-wave stub cavity are performed for a sequence of identically shaped millimeter-scale neodymium magnets having varying strengths. Magnet levitation within the cavity is accompanied by both gradual and abrupt shifts in the resonance frequency (with a height sensitivity as large as 400 MHz/mm) as well as changes in the total quality factor (8%-17%) as a function of temperature during the superconducting transition of the aluminum cavity. Prior to magnet motion and levitation, the Q of the cavity changes quadratically with temperature, as expected, as the walls of the cavity undergo the superconducting transition. We observe, however, a deviation from the quadratic trend which is attributable to magnet movement within the cavity. Such an electromechanical system is a transducer between mechanical and microwave oscillators enabling coupling of low-frequency mechanical motion of the magnet to other quantum objects, such as magnons and transmons, which are used for sensing and quantum information processing.


  • Open Access

    Magnetic levitation within a microwave cavity: characterization, challenges, and possibilities

    by Nabin K. Raut, Jeffery Miller, Raymond E. Chiao, Jay E. Sharping

    The low energy losses in the superconducting magnetic levitation make it attractive for exciting applications in physics. Recently, superconducting magnetic levitation has been realized as novel mechanical transduction for the individual spin qubit in the nitrogen-vacancy center [1]. Furthermore, the Meissner has been proposed for the study of modified gravitational wave detection [2]. Meissner levitation within the microwave cavity could open avenues for the novel cavity optomechanical system, readout for quantum object such as the transmon, and magnon, gravitational wave detection, and magnetomechanics [3]. This work characterized magnetic levitation within a microwave. It also discusses possibilities, challenges, and room temperature and cryogenic experiments of the cavity-magnet system.


  • Meissner Levitation of a Millimeter-Size Neodymium Magnet Within a Superconducting Radio Frequency Cavity

    by Nabin K. Raut, Jeffery Miller, Jacob Pate, Raymond Chiao, Jay E. Sharping

    We report on the magnetic levitation of a millimeter-sized neodymium permanent magnet within the interior of a superconducting radio frequency (SRF) cavity. To the best of our knowledge, this is the first experimental work on levitating a magnet within an SRF cavity. The cavity is a coaxial quarter-wave microwave resonator made from 6061 aluminum, having a resonance frequency of 10 GHz and a loaded Q of 1400. The cylindrical magnet (N50) has a height of 1 mm, a diameter of 0.75 mm, a mass of 4 mg, and a remanence of 1.44 T. This produces a peak magnetic field 140 times greater than the critical field of aluminum. The magnet is placed either on the top of the coaxial portion of the cavity or on the cavity floor before cooling it below the superconducting transition temperature of aluminum. The coaxial mode's resonance frequency shifts as a function of the levitation height of the magnet and gives an idea of the magnet's position and mechanical motion. We observe a transition at a temperature of 650 mK where the Meissner effect levitates the magnet as the material beneath the magnet becomes superconducting. The magnet is levitated to a height of 2.5 mm above the surface of the cavity stub, which is a sufficient separation for the field strength of the magnet at the surface of the stub to be less than the critical field strength of the superconducting aluminum. We measure a 120 MHz upshift in the cavity resonance as the magnet is levitated from the top of the stub and 15 MHz downshift as it levitates from the floor of the cavity. Our measurements are consistent over several heating and cooling cycles. Our work provides a path towards a novel optomechanical system.


  • Open Access

    Meissner levitation of a millimeter size neodymium magnet within a superconducting radio frequency cavity

    by N. K. Raut, J. Miller, J. Pate, R. Chiao, J. E. Sharping

    We report on the magnetic levitation of a millimeter sized neodymium permanent magnet within the interior of a superconducting radio frequency (SRF) cavity. To the best of our knowledge, this is the first experimental work on levitating a magnet within an SRF cavity. The cavity is a coaxial quarter wave microwave resonator made from 6061 aluminum, having a resonance frequency of 10GHz and a loaded Q of 1400. The cylindrical magnet (N50) has a height of 1 mm, a diameter of 0.75 mm, a mass of 4 mg, and a remanence of 1.44 T. This produces a peak magnetic field 140 times greater than the critical field of aluminum. Our measurements are consistent over several heating and cooling cycles. Our work provides a path towards a novel optomechanical system.