MAMuhammad Kabir Abdulkadir

Muhammad Kabir Abdulkadir

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Muhammad Kabir Abdulkadir has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • Anusha Achuthan

    Department of Computer Science, School of Computer Science, Universiti Sains Malaysia, Penang, Malaysia

    2 shared publications
  • Ibrahim Lutfi Shuaib

    Department of Biomedical Imaging, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Malaysia

    2 shared publications
  • Noor Diyana Osman

    Universiti Sains Malaysia

    2 shared publications
  • Abacha Mohammed

    Department of Radiography, Faculty of Clinical Sciences, College of Health Sciences, Usmanu Danfodiyo University Sokoto, Nigeria

    1 shared publication
  • Abdulaziz Abdulkarim

    Radiology Department, Federal Medical Centre, Azare, Azare, Nigeria

    1 shared publication
  • Ahmad Hadif Zaidin Samsudin

    Department of Radiology , School of Medical Sciences 16150 Kubang Kerian, Kelantan , Malaysia

    1 shared publication

Latest Publications

  • Open Access

    A Segmentation-based Automated Calculation of Patient Size and Size-specific Dose Estimates in Pediatric Computed Tomography Scans

    by Muhammad Kabir Abdulkadir, Noor Diyana Osman, Anusha Achuthan, Radin A. Nasirudin, Muhammad Zabidi Ahmad, Noor Hasyima Mat Zain, Ibrahim Lutfi Shuaib

    Background and Purpose: Size-specific dose estimates (SSDE) have been introduced into computed tomography (CT) dosimetry to tailor patients’ unique sizes to facilitate accurate CT radiation dose quantification and optimization. The purpose of this study was to develop and validate an automated algorithm for the determination of patient size (effective diameter) and SSDE. Materials and Methods: A MATLAB platform was used to develop software of algorithms based on image segmentation techniques to automate the calculation of patient size and SSDE. The algorithm was used to automatically estimate the individual size and SSDE of four CT dose index phantoms and 80 CT images of pediatric patients comprising head, thorax, and abdomen scans. For validation, the American Association of Physicists in Medicine (AAPM) manual methods were used to determine the patient’s size and SSDE for the same subjects. The accuracy of the proposed algorithm in size and SSDE calculation was evaluated for agreement with the AAPM’s estimations (manual) using Bland–Altman’s agreement and Pearson’s correlation coefficient. The normalized error, system bias, and limits of agreement (LOA) between methods were derived. Results: The results demonstrated good agreement and accuracy between the automated and AAPM’s patient size estimations with an error rate of 1.9% and 0.27% on the patient and phantoms study, respectively. A 1% percentage difference was found between the automated and manual (AAPM) SSDE estimates. A strong degree of correlation was seen with a narrow LOA between methods for clinical study ( r > 0.9771) and phantom study ( r > 0.9999). Conclusion: The proposed automated algorithm provides an accurate estimation of patient size and SSDE with negligible error after validation.


  • ESTIMATION OF PEDIATRIC DOSE DESCRIPTORS ADAPTED TO INDIVIDUAL SPECIFIC SIZE FROM CT EXAMINATIONS

    by Muhammad Kabir Abdulkadir, Ibrahim Lutfi Shuaib, Anusha Achuthan, Radin A Nasirudin, Ahmad Hadif Zaidin Samsudin, Noor Diyana Osman

    Clinical challenges in pediatrics dose estimation by the displayed computed tomography (CT) dose indices may lead to inaccuracy, and thus size-specific dose estimate (SSDE) is introduced for better-personalized dose estimation. This study aims to estimate pediatric dose adapted to specific size. This retrospective study involved pediatric population aged 0–12 y. SSDE was derived from scanner reported volume CT dose index (CTDIvol), based on individual effective diameter (Deff) with corresponding size correction factors. The correlations of Deff with other associated factors such as age, exposure setting, CTDIvol and SSDE were also studied. The average Deff of Malaysian pediatric was smaller than reference phantom size (confidence interval, CI = 0.28, mean = 14.79) and (CI = 0.51, mean = 16.33) for head and abdomen, respectively. These have led to underestimation of pediatric dose as SSDE was higher than displayed CTDIvol. The percentage differences were statistically significant (p < .001) ranged from 0 to 17% and 37 to 60% for head and abdominal CT, respectively. In conclusion, the clinical implementation of SSDE in pediatric CT imaging is highly relevant to reduce radiation risk.


  • Open Access

    Assessment of diagnostic reference levels awareness and knowledge amongst CT radiographers

    by Muhammad K. Abdulkadir, Albert D. Piersson, Goni M. Musa, Sadiq A. Audu, Auwal Abubakar, Basirat Muftaudeen, Josiah E. Umana

    Background: Reports indicated that numerous factors, including inadequate personnel knowledge, contributes to insufficient patient data for setting up diagnostic reference levels (DRLs) in developing countries. This study aims to evaluate the knowledge of DRLs as an optimisation tool amongst computed tomography (CT) radiographers in northern Nigeria. This is a quantitative cross-sectional study. A structured questionnaire was devised and distributed on site to sixty-two CT radiographers in northern Nigeria. A total of fifteen questions were included in the questionnaire focusing on DRLs, dose optimisation and dose descriptors generating quantitative data concerning overall CT radiographers’ perceived knowledge and awareness about DRLs.Results: A response rate of 77.4% (48/62) was achieved. About 83.3% of the participants declare DRLs awareness, and 37.5% carried out a local dose survey. The percentage correctly perceived knowledge of concepts; DRLs was 45.8%, dose optimisation (42%) and CT dose descriptor (39%). Radiographers with work experience ranging from 4-10 years had the highest score.Conclusion: In this survey, deficiencies were noted in radiographers’ knowledge about DRLs with precise knowledge gap in the implementation of local dose survey for DRLs and optimisation. There is a need for continuous radiographers’ training with greater emphasis on dose optimisation and institutional based dose evaluation.


  • Evaluation of age-based radiation dose in paediatric patients received from head CT examination at a tertiary hospital, Nigeria

    by Muhammad Kabir Abdulkadir, Iliyasu Yusuf Izge, Garba Haruna Yunusa, Abacha Mohammed, Noor Diyana Osman


  • Open Access

    Sonographic Assessment of Fetal Neck Circumference (NC) As a Predictor of Gestational Age

    by Muhammad K. Abdulkadir, Ivor C. Nwobi, Auwal Abubakar, Ilyasu Izge, Abdulaziz Abdulkarim

    Background The need for development of population based nomograms for ultrasound fetal dating cannot be overemphasised. The objective of this study was to develop a nomogram of Fetal Neck Circumference (NC) for predicting gestational age for this population. Methods This was a cross sectional prospective study of 203 singleton normal pregnant women of 15–40 weeks’ gestation. Fetal NC was measured the 5th, 50th and 95th centile values were estimated at each week of gestational age, 50th centile values were then compared to Caucasian and African population study to assess variability. Results A nomogram was derived and NC values showed no statistical significant difference compared to the Caucasians (p = 0.065, 0.257) and African (p = 0.947) population. There was a strong positive significant correlation (r2 = 0.799; p = 0.001) between NC and average gestational age. Method of least square yielded to the equation y = 2.22x + 5.390. NC relationship with BPD (r2 = 0.859; p = 0.001), FL (r2 = 0.842; p = 0.001) and HC (r2 = 0.662; p = 0.001) were also significant and positive. Estimated weekly increase in NC was 0.72 cm. Conclusion This study derived nomogram for ultrasound measurement of fetal NC in a Northern Nigerian population. However, NC values from this study differ less with an African population than with Caucasian study population.