HerambaGanapathy Selvarajan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
HerambaGanapathy Selvarajan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Bradley McPherson
Division of Speech and Hearing Sciences, the University of Hong Kong, Hong Kong, China
2 shared publicationsBinu Ninan
Sri Ramachandra Inst Higher Educ & Res DU, Dept Neonatol, Chennai, Tamil Nadu, India
1 shared publicationDivyaShantha Kumari Adinarayanan
Saveetha Med Coll & Hosp, Dept ENT, Chennai, Tamil Nadu, India
1 shared publicationGayathri Sundaravadhanan
Department of Speech, Language & Hearing Sciences, Sri Ramachandra University, Chennai, Tamil Nadu, India
1 shared publicationGomathi Saravanan
Department of Otorhinolaryngology, Chengalpattu Medical College & Hospital, Chengalpattu, Tamil Nadu, India
1 shared publication- Madhan Chandrasekar
Department of Speech, Language and Hearing Sciences, Sri Ramachandra Institute of Higher Education and Research Institute (DU), Tamil Nadu, Porur, India
1 shared publication
Latest Publications
- 26 February 2021
- Published by Springer Nature in Indian Journal of Otolaryngology and Head & Neck Surgery
- Vol. 74 (S1) , 639-650
Status of Newborn Hearing Screening Program in the State of Tamil Nadu, India
Newborn hearing screening in India is gaining momentum and more programs are getting established every year. We need to know their performance levels, strengths and weaknesses to provide suggestions for building effective future programs. The study aimed to report the status of Newborn Hearing Screening (NHS) program in the state of Tamil Nadu, India. A questionnaire on “Newborn Hearing Screening Survey” was developed and sent to 80 sites with NHS facility all over Tamil Nadu, India. The information collected was subjected to descriptive statistical analyses. On a 95% return rate, private sector contribution towards NHS program are the highest and most of the private hospitals have outsourced the NHS program. In most of the sites, audiologists are incharge of the NHS program and carried out the NHS testing. The majority of sites (67.1%) follow selective screening such as high risk factors, doctor’s referral and admission at NICU. The preferred testing was TEOAE in the screening program. NHS protocol was found to be variable at each site and for each patient. The time between second screening and diagnostic testing went up to 3-6 months. However, there is a lack of organized system for documenting the program outcome. The result of this study calls the need for wider implementation of UNHS and to introduce a centralised state or local reporting system for documenting and tracking the infants with hearing impairment.
- 26 February 2021
- Published by Springer Nature in Indian Journal of Otolaryngology and Head & Neck Surgery
- Vol. 74 (S1) , 639-650
Status of Newborn Hearing Screening Program in the State of Tamil Nadu, India
Newborn hearing screening in India is gaining momentum and more programs are getting established every year. We need to know their performance levels, strengths and weaknesses to provide suggestions for building effective future programs. The study aimed to report the status of Newborn Hearing Screening (NHS) program in the state of Tamil Nadu, India. A questionnaire on “Newborn Hearing Screening Survey” was developed and sent to 80 sites with NHS facility all over Tamil Nadu, India. The information collected was subjected to descriptive statistical analyses. On a 95% return rate, private sector contribution towards NHS program are the highest and most of the private hospitals have outsourced the NHS program. In most of the sites, audiologists are incharge of the NHS program and carried out the NHS testing. The majority of sites (67.1%) follow selective screening such as high risk factors, doctor’s referral and admission at NICU. The preferred testing was TEOAE in the screening program. NHS protocol was found to be variable at each site and for each patient. The time between second screening and diagnostic testing went up to 3-6 months. However, there is a lack of organized system for documenting the program outcome. The result of this study calls the need for wider implementation of UNHS and to introduce a centralised state or local reporting system for documenting and tracking the infants with hearing impairment.
- 1 January 2020
- Published by Medknow in Indian Journal of Otology
- Vol. 26 (4) , 263-264
Neonatal hearing screening during breastfeeding
- 1 January 2020
- Published by Medknow in Indian Journal of Otology
- Vol. 26 (4) , 263-264
Neonatal hearing screening during breastfeeding
- Open Access
- 1 March 2019
- Published by Angle Publishing Co., Ltd.
- Vol. 21 (99) , 83-95
Profiling indian classroom listening conditions in schools for children with hearing impairment
Introduction: An optimal classroom acoustic environment is essential for children with hearing impairment to achieve academic success. The aim of the present study is to provide an overview of classroom listening conditions in schools for children with hearing impairment in a developing country context. Materials and Methods: Noise levels were measured in 37 classrooms from four schools in Chennai, India. Teacher speech levels were measured to obtain classroom speech to noise ratio (SNR) data. The reverberation time was estimated for each classroom. Results: The mean noise level and reverberation time in all classrooms exceeded recommended maximum levels. The measured SNRs were not optimal for children with hearing impairment. Observations of the classrooms revealed that acoustical treatments were inadequate. Conclusion: The results indicated that Indian schools for children with hearing impairment should take steps to improve classroom listening environments. Possible solutions that may alleviate suboptimal classroom sound environments are discussed.
- 1 March 2019
- Published by Angle Publishing Co., Ltd.
- Vol. 21 (99) , 83-95
Open AccessProfiling indian classroom listening conditions in schools for children with hearing impairment
Introduction: An optimal classroom acoustic environment is essential for children with hearing impairment to achieve academic success. The aim of the present study is to provide an overview of classroom listening conditions in schools for children with hearing impairment in a developing country context. Materials and Methods: Noise levels were measured in 37 classrooms from four schools in Chennai, India. Teacher speech levels were measured to obtain classroom speech to noise ratio (SNR) data. The reverberation time was estimated for each classroom. Results: The mean noise level and reverberation time in all classrooms exceeded recommended maximum levels. The measured SNRs were not optimal for children with hearing impairment. Observations of the classrooms revealed that acoustical treatments were inadequate. Conclusion: The results indicated that Indian schools for children with hearing impairment should take steps to improve classroom listening environments. Possible solutions that may alleviate suboptimal classroom sound environments are discussed.
- Open Access
- 1 January 2017
- Published by Medknow in Noise and Health
- Vol. 19 (86) , 31-40
Classroom Listening Conditions in Indian Primary Schools: A Survey of Four Schools
Introduction: Background noise affects the listening environment inside classrooms, especially for younger children. High background noise level adversely affects not only student speech perception but also teacher vocal hygiene. The current study aimed to give an overview of the classroom listening conditions in selected government primary schools in India. Materials and Methods: Noise measurements were taken in 23 classrooms of four government primary schools in southern India, using a type 2 sound level meter. In each classroom measurements were taken in occupied and unoccupied conditions. Teacher voice level was measured in the same classrooms. In addition, the classroom acoustical conditions were observed and the reverberation time for each classroom was calculated. Results: The mean occupied noise level was 62.1 dBA and 65.6 dBC, and the mean unoccupied level was 62.2 dBA and 65 dBC. The mean unamplified teacher speech-to-noise ratio was 10.6 dBA. Both the occupied and unoccupied noise levels exceeded national and international recommended levels and the teacher speech-to-noise ratio was also found to be inadequate in most classrooms. The estimated reverberation time in all classrooms was greater than 2.6 seconds, which is almost double the duration of accepted standards. In addition, observation of classrooms revealed insufficient acoustical treatment to effectively reduce internal and external noise and minimize reverberation. Conclusion: The results of this study point out the need to improve the listening environment for children in government primary schools in India.
- 1 January 2017
- Published by Medknow in Noise and Health
- Vol. 19 (86) , 31-40
Open AccessClassroom Listening Conditions in Indian Primary Schools: A Survey of Four Schools
Introduction: Background noise affects the listening environment inside classrooms, especially for younger children. High background noise level adversely affects not only student speech perception but also teacher vocal hygiene. The current study aimed to give an overview of the classroom listening conditions in selected government primary schools in India. Materials and Methods: Noise measurements were taken in 23 classrooms of four government primary schools in southern India, using a type 2 sound level meter. In each classroom measurements were taken in occupied and unoccupied conditions. Teacher voice level was measured in the same classrooms. In addition, the classroom acoustical conditions were observed and the reverberation time for each classroom was calculated. Results: The mean occupied noise level was 62.1 dBA and 65.6 dBC, and the mean unoccupied level was 62.2 dBA and 65 dBC. The mean unamplified teacher speech-to-noise ratio was 10.6 dBA. Both the occupied and unoccupied noise levels exceeded national and international recommended levels and the teacher speech-to-noise ratio was also found to be inadequate in most classrooms. The estimated reverberation time in all classrooms was greater than 2.6 seconds, which is almost double the duration of accepted standards. In addition, observation of classrooms revealed insufficient acoustical treatment to effectively reduce internal and external noise and minimize reverberation. Conclusion: The results of this study point out the need to improve the listening environment for children in government primary schools in India.