Akihisa Kaneko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Akihisa Kaneko has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Yasuhiro Hayashi
Department of Electrical Engineering and Bioscience, Waseda University, Tokyo 169-8555, Japan
10 shared publications - Yu Fujimoto
Advanced Collaborative Research Organization for Smart Society, Waseda University, Tokyo 169-8555, Japan
4 shared publications - Kohto Watanabe
Graduate School of Advanced Science and Engineering, Waseda University, Tokyo 169-8555, Japan
2 shared publications - Masako Kawazoe
Chubu Electric Power Grid Co., Inc., Nagoya 461-8680, Aichi, Japan
2 shared publications - Shigeru Kobori
Chubu Electric Power Grid Co., Inc., Nagoya 461-8680, Aichi, Japan
2 shared publications - Shunsuke Sasaki
Chubu Electric Power Grid Co., Inc., Nagoya 461-8680, Aichi, Japan
2 shared publications
Latest Publications
- Open Access
Step Voltage Regulator Control Parameter Determination Using Short-Term Photovoltaic Output Estimation Adapted for Sharp Voltage Fluctuations in Distribution Networks
High photovoltaic (PV) penetration in distribution networks can cause significant voltage deviations, making effective voltage regulation a critical issue for distribution system operators. Step voltage regulators (SVRs) provide a cost-effective solution; however, their performance strongly depends on control parameter settings that should account for PV-induced voltage fluctuations. Because installing high-resolution sensors at all PV sites is impractical, this paper proposes a method for determining SVR control parameters using short-term PV output estimation. The proposed approach assumes that only large-capacity PV systems are equipped with high-resolution sensors and estimates the outputs of other PV systems using the inverse distance weighting (IDW) method. Based on historical power flow data and estimated PV outputs, the method determines 48 sets of SVR control parameters for the following day while capturing rapid voltage rises caused by PV fluctuations. Numerical simulations using a practical distribution network model developed from an actual Chubu Electric Power Grid Co., Inc. system demonstrate the effectiveness of the proposed method. The results show that the allowable PV hosting capacity increases by 25% compared with a method without short-term PV output estimation, while the increase in SVR tap operations remains within an acceptable range.
Open AccessStep Voltage Regulator Control Parameter Determination Using Short-Term Photovoltaic Output Estimation Adapted for Sharp Voltage Fluctuations in Distribution Networks
High photovoltaic (PV) penetration in distribution networks can cause significant voltage deviations, making effective voltage regulation a critical issue for distribution system operators. Step voltage regulators (SVRs) provide a cost-effective solution; however, their performance strongly depends on control parameter settings that should account for PV-induced voltage fluctuations. Because installing high-resolution sensors at all PV sites is impractical, this paper proposes a method for determining SVR control parameters using short-term PV output estimation. The proposed approach assumes that only large-capacity PV systems are equipped with high-resolution sensors and estimates the outputs of other PV systems using the inverse distance weighting (IDW) method. Based on historical power flow data and estimated PV outputs, the method determines 48 sets of SVR control parameters for the following day while capturing rapid voltage rises caused by PV fluctuations. Numerical simulations using a practical distribution network model developed from an actual Chubu Electric Power Grid Co., Inc. system demonstrate the effectiveness of the proposed method. The results show that the allowable PV hosting capacity increases by 25% compared with a method without short-term PV output estimation, while the increase in SVR tap operations remains within an acceptable range.
- Open Access
Spatiotemporal Sparsified Dynamic Reconfiguration Scheduling Method for High-Photovoltaic-Penetration Distribution Systems
To address the operational challenges posed by the high penetration of photovoltaic systems in distribution networks—such as system congestion, voltage violations, and increased distribution losses—this study proposes a spatiotemporal sparsified dynamic reconfiguration scheduling method considering practical implementation in real distribution system operations. The proposed framework comprises two complementary sparsification mechanisms. Spatial sparsification is achieved by clustering hourly net-load distributions in a high-dimensional net-load space to aggregate characteristic net-load patterns, thereby restricting power flow evaluations and configuration screening to a small set of representative patterns and substantially reducing the computational burden. Temporal sparsification is realized by solving an integer linear programming problem to optimize the reconfiguration schedule under a daily reconfiguration frequency constraint, which optimizes the reconfiguration timing while mitigating excessive switching operations. Numerical experiments under deterministic forecast assumptions demonstrated that the proposed method can effectively eliminate congestion and voltage violations while achieving loss reduction by 4.56% and 27.4% respectively in two scenarios from the conventional method with the computational scalability significantly improved.
Open AccessSpatiotemporal Sparsified Dynamic Reconfiguration Scheduling Method for High-Photovoltaic-Penetration Distribution Systems
To address the operational challenges posed by the high penetration of photovoltaic systems in distribution networks—such as system congestion, voltage violations, and increased distribution losses—this study proposes a spatiotemporal sparsified dynamic reconfiguration scheduling method considering practical implementation in real distribution system operations. The proposed framework comprises two complementary sparsification mechanisms. Spatial sparsification is achieved by clustering hourly net-load distributions in a high-dimensional net-load space to aggregate characteristic net-load patterns, thereby restricting power flow evaluations and configuration screening to a small set of representative patterns and substantially reducing the computational burden. Temporal sparsification is realized by solving an integer linear programming problem to optimize the reconfiguration schedule under a daily reconfiguration frequency constraint, which optimizes the reconfiguration timing while mitigating excessive switching operations. Numerical experiments under deterministic forecast assumptions demonstrated that the proposed method can effectively eliminate congestion and voltage violations while achieving loss reduction by 4.56% and 27.4% respectively in two scenarios from the conventional method with the computational scalability significantly improved.
- Open Access
- 6 June 2026
- Published by Elsevier in SSRN Electronic Journal
Simultaneous Enhancement of Regional and System-Wide Frequency Stability via Global-Local Adaptive Control of Virtual Synchronous Generators
The integration of inverter-based resources is reducing electric power-system inertia and threatening frequency stability, motivating the deployment of virtual synchronous generators (VSGs) to provide inertial and fast frequency response. In large-scale grids, however, conventional local adaptive control (LAC) of VSGs underperforms because regional frequencies oscillate around the center-of-inertia (COI) frequency rather than evolving uniformly. This dynamic discrepancy triggers erratic parameter switching and leaves the regulatory headroom of VSGs distant from the disturbance largely unused. To overcome these limitations, this paper proposes a global-local adaptive control (GLAC) scheme that integrates the wide-area COI frequency obtained from phasor measurement units (PMUs) with the locally measured VSG internal frequency. The COI frequency is used to dictate the timing of parameter updates and thereby suppress erratic switching, while the larger of the local and global frequency deviations is selected to scale the inertia and fast frequency response gains, mobilizing the active power headroom of every VSG regardless of its electrical distance from the disturbance. The proposed scheme is validated through PSCAD/EMTDC time-domain simulations on a modified IEEJ WEST 10-machine model representing western Japan—a grid in which regional frequency oscillations are particularly significant—under three disturbance scenarios with different spatial VSG distributions. GLAC consistently outperforms LAC in maximum rate of change of frequency and frequency deviations at both regional and system levels, and sensitivity analyzes confirm its robustness across a wide range of regulation coefficients and practical PMU communication delays.
- 6 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSimultaneous Enhancement of Regional and System-Wide Frequency Stability via Global-Local Adaptive Control of Virtual Synchronous Generators
The integration of inverter-based resources is reducing electric power-system inertia and threatening frequency stability, motivating the deployment of virtual synchronous generators (VSGs) to provide inertial and fast frequency response. In large-scale grids, however, conventional local adaptive control (LAC) of VSGs underperforms because regional frequencies oscillate around the center-of-inertia (COI) frequency rather than evolving uniformly. This dynamic discrepancy triggers erratic parameter switching and leaves the regulatory headroom of VSGs distant from the disturbance largely unused. To overcome these limitations, this paper proposes a global-local adaptive control (GLAC) scheme that integrates the wide-area COI frequency obtained from phasor measurement units (PMUs) with the locally measured VSG internal frequency. The COI frequency is used to dictate the timing of parameter updates and thereby suppress erratic switching, while the larger of the local and global frequency deviations is selected to scale the inertia and fast frequency response gains, mobilizing the active power headroom of every VSG regardless of its electrical distance from the disturbance. The proposed scheme is validated through PSCAD/EMTDC time-domain simulations on a modified IEEJ WEST 10-machine model representing western Japan—a grid in which regional frequency oscillations are particularly significant—under three disturbance scenarios with different spatial VSG distributions. GLAC consistently outperforms LAC in maximum rate of change of frequency and frequency deviations at both regional and system levels, and sensitivity analyzes confirm its robustness across a wide range of regulation coefficients and practical PMU communication delays.
- Open Access
Quantitative Assessment of Short-Term Photovoltaic Output Estimation Based on Sensor Measurements in an Actual Japanese Distribution Network
The importance of considering the photovoltaic (PV) output in distribution system operations and planning has increased. Voltage violations and equipment overloads may occur during PV output peaks, making accurate power flow analysis under such conditions essential. However, the PV output is typically measured as 30 min aggregated values by smart meters, which may underestimate the peak output and related power flow fluctuations. Installing high-resolution sensors at all the PV sites can address this issue; however, the associated costs are high. As a cost-effective alternative, high-resolution sensors can be deployed at representative PV sites, and their measurements can be used to estimate short-term outputs at surrounding PV sites. Implementing such an approach requires a quantitative evaluation of the relationship between the sensor number and PV output estimation accuracy. In the Chubu area of Japan, a trial region with sufficient high-resolution PV sensors exists, enabling detailed evaluation. This study developed a framework to estimate short-term PV outputs from representative sensors and used field data from the demonstration area to quantitatively assess the relationship between sensor deployment and estimation accuracy. These results provide guidance for designing cost-effective sensor placement strategies for practical network operations.
Open AccessQuantitative Assessment of Short-Term Photovoltaic Output Estimation Based on Sensor Measurements in an Actual Japanese Distribution Network
The importance of considering the photovoltaic (PV) output in distribution system operations and planning has increased. Voltage violations and equipment overloads may occur during PV output peaks, making accurate power flow analysis under such conditions essential. However, the PV output is typically measured as 30 min aggregated values by smart meters, which may underestimate the peak output and related power flow fluctuations. Installing high-resolution sensors at all the PV sites can address this issue; however, the associated costs are high. As a cost-effective alternative, high-resolution sensors can be deployed at representative PV sites, and their measurements can be used to estimate short-term outputs at surrounding PV sites. Implementing such an approach requires a quantitative evaluation of the relationship between the sensor number and PV output estimation accuracy. In the Chubu area of Japan, a trial region with sufficient high-resolution PV sensors exists, enabling detailed evaluation. This study developed a framework to estimate short-term PV outputs from representative sensors and used field data from the demonstration area to quantitatively assess the relationship between sensor deployment and estimation accuracy. These results provide guidance for designing cost-effective sensor placement strategies for practical network operations.
- Open Access
- 29 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 96213-96225
Grid Congestion Management Based on the Renewable Energy Zones and Clustering of Grid Congestion Conditions
This study proposes a novel output curtailment method of renewable energy sources (RESs) to mitigate grid congestion while balancing curtailment minimization and fairness among power producers, considering the operational efficiency of system operators. This method is based on creating zones using sensitivity analysis and clustering grid congestion conditions. Recently, the large introduction of RESs has raised concerns of grid congestion in power systems. To mitigate congestion, the system operator curtails the output of RESs; however, the curtailment should be minimized while ensuring equal generation opportunities among power producers. The proposed method divides RESs into multiple zones according to the congestion mitigation effect of their output curtailment and uniformly curtails them in each zone. Moreover, the method divides congestion conditions throughout the year by clustering and creates zones of RESs for each congestion pattern. This approach aims to apply the optimal zone division of RESs according to the congestion condition, while removing the burden on the operator to recreate the zone division for each time step. A simulation was conducted to evaluate the effectiveness of the proposed method using a bulk power system model in the northern area of Tohoku region of Japan. Based on the simulation results, our proposed method outperforms existing approaches in terms of minimizing RES curtailment and promoting fairness across power producers, while considering the frequency of zonal creation.
- 29 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 96213-96225
Open AccessGrid Congestion Management Based on the Renewable Energy Zones and Clustering of Grid Congestion Conditions
This study proposes a novel output curtailment method of renewable energy sources (RESs) to mitigate grid congestion while balancing curtailment minimization and fairness among power producers, considering the operational efficiency of system operators. This method is based on creating zones using sensitivity analysis and clustering grid congestion conditions. Recently, the large introduction of RESs has raised concerns of grid congestion in power systems. To mitigate congestion, the system operator curtails the output of RESs; however, the curtailment should be minimized while ensuring equal generation opportunities among power producers. The proposed method divides RESs into multiple zones according to the congestion mitigation effect of their output curtailment and uniformly curtails them in each zone. Moreover, the method divides congestion conditions throughout the year by clustering and creates zones of RESs for each congestion pattern. This approach aims to apply the optimal zone division of RESs according to the congestion condition, while removing the burden on the operator to recreate the zone division for each time step. A simulation was conducted to evaluate the effectiveness of the proposed method using a bulk power system model in the northern area of Tohoku region of Japan. Based on the simulation results, our proposed method outperforms existing approaches in terms of minimizing RES curtailment and promoting fairness across power producers, while considering the frequency of zonal creation.
- Open Access
Charging Incentive Design with Minimum Price Guarantee for Battery Energy Storage Systems to Mitigate Grid Congestion
The large-scale integration of renewable energy sources (RESs) has raised concerns regarding grid congestion in Japan. Battery energy storage systems (BESSs) can mitigate congestion by adjusting charging schedules; however, BESS owners basically prioritize market arbitrage, which may not be aligned with congestion mitigation. This paper proposes a charging incentive design to guide arbitrage-oriented BESS charging toward time periods that are effective for grid congestion mitigation. The system operator predicts congested hours and ensures that BESS owners can purchase electricity at the lowest daily market price. This design intends to shift the BESS charging time towards congestion periods. Because market prices tend to decline during congestion periods, the proposed method reduces the operator’s financial burden while encouraging congestion-mitigating charging behavior. Numerical simulations using a simplified Japanese east-side power system model demonstrate that the proposed method reduced the congestion mitigation costs by 3.86% and curtailed the RES output by 3.89%, compared to using no incentive method (current operation in Japan). Furthermore, additional payments to BESS owners accounted for only around 7% of the resulting cost savings, indicating that the proposed method achieved lower overall system operating costs.
Open AccessCharging Incentive Design with Minimum Price Guarantee for Battery Energy Storage Systems to Mitigate Grid Congestion
The large-scale integration of renewable energy sources (RESs) has raised concerns regarding grid congestion in Japan. Battery energy storage systems (BESSs) can mitigate congestion by adjusting charging schedules; however, BESS owners basically prioritize market arbitrage, which may not be aligned with congestion mitigation. This paper proposes a charging incentive design to guide arbitrage-oriented BESS charging toward time periods that are effective for grid congestion mitigation. The system operator predicts congested hours and ensures that BESS owners can purchase electricity at the lowest daily market price. This design intends to shift the BESS charging time towards congestion periods. Because market prices tend to decline during congestion periods, the proposed method reduces the operator’s financial burden while encouraging congestion-mitigating charging behavior. Numerical simulations using a simplified Japanese east-side power system model demonstrate that the proposed method reduced the congestion mitigation costs by 3.86% and curtailed the RES output by 3.89%, compared to using no incentive method (current operation in Japan). Furthermore, additional payments to BESS owners accounted for only around 7% of the resulting cost savings, indicating that the proposed method achieved lower overall system operating costs.
- Open Access
Quantitative Difference Between the Effective Inertia and Set Inertia Parameter of Virtual Synchronous Generators
Virtual synchronous generators (VSGs) have been developed to mitigate the increase in the rate of change of frequency (ROCOF) in power systems by replacing synchronous generators (SGs) with inverter-based resources. VSGs mimic the dynamics and control of SGs; however, the mechanical delay typical of an SG’s turbine is often excluded, limiting improvements to the VSG’s response. The fast frequency response (FFR) of VSGs can help reduce ROCOF and enhance emulated inertia. This implies that the effective inertia (EI) of VSGs can exceed the set inertia parameter, posing challenges for operators in allocating sufficient VSG capacity considering the inertia required for stable operation. In this study, we quantitatively analyzed the difference between the EI of a VSG and the set inertia parameter by separating the active power output into inertia and governor responses. The quantitative analysis revealed that when the VSG provides FFR within the inertia-time domain, the EI exceeds the set inertia parameter. Furthermore, the sensitivities of the VSG set parameters and VSG capacity ratio, which is related to synchronizing power coefficients and the initial sharing ratio, for the EI were analyzed. These factors were theoretically considered, and the simulations validated their characteristics.
Open AccessQuantitative Difference Between the Effective Inertia and Set Inertia Parameter of Virtual Synchronous Generators
Virtual synchronous generators (VSGs) have been developed to mitigate the increase in the rate of change of frequency (ROCOF) in power systems by replacing synchronous generators (SGs) with inverter-based resources. VSGs mimic the dynamics and control of SGs; however, the mechanical delay typical of an SG’s turbine is often excluded, limiting improvements to the VSG’s response. The fast frequency response (FFR) of VSGs can help reduce ROCOF and enhance emulated inertia. This implies that the effective inertia (EI) of VSGs can exceed the set inertia parameter, posing challenges for operators in allocating sufficient VSG capacity considering the inertia required for stable operation. In this study, we quantitatively analyzed the difference between the EI of a VSG and the set inertia parameter by separating the active power output into inertia and governor responses. The quantitative analysis revealed that when the VSG provides FFR within the inertia-time domain, the EI exceeds the set inertia parameter. Furthermore, the sensitivities of the VSG set parameters and VSG capacity ratio, which is related to synchronizing power coefficients and the initial sharing ratio, for the EI were analyzed. These factors were theoretically considered, and the simulations validated their characteristics.
- Open Access
- 10 July 2024
- Published by Taylor & Francis in Big Earth Data
- Vol. 8  (4) , 732-754
Historical reconstruction dataset of hourly expected wind generation based on dynamically downscaled atmospheric reanalysis for assessing spatio-temporal impact of on-shore wind in Japan
1. The introduction of renewable energies is accelerating in numerous countries to achieve the greenhouse gas emission reduction targets of the Paris Agreement for climate change. In particular, wi...
- 10 July 2024
- Published by Taylor & Francis in Big Earth Data
- Vol. 8  (4) , 732-754
Open AccessHistorical reconstruction dataset of hourly expected wind generation based on dynamically downscaled atmospheric reanalysis for assessing spatio-temporal impact of on-shore wind in Japan
1. The introduction of renewable energies is accelerating in numerous countries to achieve the greenhouse gas emission reduction targets of the Paris Agreement for climate change. In particular, wi...
- Open Access
Challenges in Smartizing Operational Management of Functionally-Smart Inverters for Distributed Energy Resources: A Review on Machine Learning Aspects
The widespread introduction of functionally-smart inverters will be an indispensable factor for the large-scale penetration of distributed energy resources (DERs) via the power system. On the other hand, further smartization based on the data-centric operation of smart inverters (S-INVs) is required to cost-effectively achieve the same level of power system operational performance as before under circumstances where the spatio-temporal behavior of power flow is becoming significantly complex due to the penetration of DERs. This review provides an overview of current ambitious efforts toward smartization of operational management of DER inverters, clarifies the expected contribution of machine learning technology to the smart operation of DER inverters, and attempts to identify the issues currently open and areas where research is expected to be promoted in the future.
Open AccessChallenges in Smartizing Operational Management of Functionally-Smart Inverters for Distributed Energy Resources: A Review on Machine Learning Aspects
The widespread introduction of functionally-smart inverters will be an indispensable factor for the large-scale penetration of distributed energy resources (DERs) via the power system. On the other hand, further smartization based on the data-centric operation of smart inverters (S-INVs) is required to cost-effectively achieve the same level of power system operational performance as before under circumstances where the spatio-temporal behavior of power flow is becoming significantly complex due to the penetration of DERs. This review provides an overview of current ambitious efforts toward smartization of operational management of DER inverters, clarifies the expected contribution of machine learning technology to the smart operation of DER inverters, and attempts to identify the issues currently open and areas where research is expected to be promoted in the future.
- Open Access
- 7 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 220408-220421
Evaluation of an Optimal Radial-Loop Configuration for a Distribution Network With PV Systems to Minimize Power Loss
This paper proposes a method to determine an optimal radial-loop configuration to minimize power loss in a distribution network with photovoltaic (PV) systems and evaluates the effectiveness of this configuration. Due to the disaggregation of transmission and distribution in a deregulated power system, stable and efficient operations in terms of voltage regulation and power loss reduction utilizing existing equipment is becoming more important for distribution system operators (DSOs). Japanese DSOs operate distribution networks in a radial configuration while supplying power to customers with high reliability. One method to reduce further power loss is to upgrade the network topology to a radial-loop configuration, which achieves partial loop structures by closing the tie-switches of the radial configuration. To implement a radial-loop configuration, DSOs must first evaluate the reliability, as a loop configuration can cause a feeder circuit breaker (FCB) malfunction and an expansion of the nonsupplied area during fault conditions. However, the impact of a radial-loop configuration on reliability and effectiveness has not been verified. Therefore, this paper proposes a method to determine an optimal radial-loop configuration that minimizes active power loss and maintains high reliability. In a numerical simulation, the reliability of radial-loop configurations is verified, and the effectiveness of the configuration is analyzed in terms of active power loss and voltage regulation under several PV system penetration conditions. A 6.6 kV distribution network consisting of 6 feeders and 11 tie-switches is modeled based on an existing Japanese distribution network and used for numerical simulation.
- 7 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 220408-220421
Open AccessEvaluation of an Optimal Radial-Loop Configuration for a Distribution Network With PV Systems to Minimize Power Loss
This paper proposes a method to determine an optimal radial-loop configuration to minimize power loss in a distribution network with photovoltaic (PV) systems and evaluates the effectiveness of this configuration. Due to the disaggregation of transmission and distribution in a deregulated power system, stable and efficient operations in terms of voltage regulation and power loss reduction utilizing existing equipment is becoming more important for distribution system operators (DSOs). Japanese DSOs operate distribution networks in a radial configuration while supplying power to customers with high reliability. One method to reduce further power loss is to upgrade the network topology to a radial-loop configuration, which achieves partial loop structures by closing the tie-switches of the radial configuration. To implement a radial-loop configuration, DSOs must first evaluate the reliability, as a loop configuration can cause a feeder circuit breaker (FCB) malfunction and an expansion of the nonsupplied area during fault conditions. However, the impact of a radial-loop configuration on reliability and effectiveness has not been verified. Therefore, this paper proposes a method to determine an optimal radial-loop configuration that minimizes active power loss and maintains high reliability. In a numerical simulation, the reliability of radial-loop configurations is verified, and the effectiveness of the configuration is analyzed in terms of active power loss and voltage regulation under several PV system penetration conditions. A 6.6 kV distribution network consisting of 6 feeders and 11 tie-switches is modeled based on an existing Japanese distribution network and used for numerical simulation.