Hugo Daguerre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hugo Daguerre has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Aude Bolopion
Université Marie et Louis Pasteur, SUPMICROTECH, CNRS, Institut FEMTO-ST, F-25000 Besançon, France
2 shared publications- Michael Gauthier
FEMTO-ST Institute, Université Bourgogne Franche-Comté, CNRS, 24 rue Savary, F-25000 Besançon, France
2 shared publications - Anastasia Lavrenko
Department of Electrical Engineering, Mathematics and Computer Sciences, Radio Systems Group, University of Twente, Enschede, The Netherlands
1 shared publication - Aude Bolopion
FEMTO-ST Institute, Université Bourgogne Franche-Comté, CNRS, 24 rue Savary, F-25000 Besançon, France
1 shared publication - Benoît Romain
Université Marie et Louis Pasteur, SUPMICROTECH, CNRS, Institut FEMTO-ST, F-25000 Besançon, France
1 shared publication - Francois Marionnet
FEMTO-ST Institute, SUPMICROTECH, CNRS, Univ. Franche-Comt, Besanon, France
1 shared publication
Latest Publications
- 16 September 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (18) , 5022-5034
Impedance-based particle tracking at micrometer scale with limited training data: a deep learning architecture analysis and optimization framework
In this study, we present and analyze a deep learning framework designed to achieve real-time particle localization from successive electrical impedance measurements with a limited training dataset.
- 16 September 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (18) , 5022-5034
Impedance-based particle tracking at micrometer scale with limited training data: a deep learning architecture analysis and optimization framework
In this study, we present and analyze a deep learning framework designed to achieve real-time particle localization from successive electrical impedance measurements with a limited training dataset.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (7) , 1-4
Towards Localization of Miniaturized Medical Robots With Microwaves
The emergence of miniaturized medical robots capable of performing targeted therapeutic procedures in deep-seated anatomical regions presents an alternative to conventional medical treatments. However, it remains a significant challenge to accurately locate the miniaturized robots in the complex environments of living organisms. Taking advantage of the short wavelength and noninvasive nature, microwave sensing holds promise in detecting small foreign objects embedded in tissue based on their dielectric properties. However, the limiting factor is the trade-off between the penetration depth and the wavelength of the microwave signals. In this study, we investigate the feasibility of using microwave signals in the frequency range from 18 GHz to 40 GHz to detect centimeter to millimeter-scale metallic objects behind tissue-mimicking gelatin screens. The insights obtained from this work pave the way for the development of novel strategies for the localization of miniaturized medical robots using microwaves.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (7) , 1-4
Towards Localization of Miniaturized Medical Robots With Microwaves
The emergence of miniaturized medical robots capable of performing targeted therapeutic procedures in deep-seated anatomical regions presents an alternative to conventional medical treatments. However, it remains a significant challenge to accurately locate the miniaturized robots in the complex environments of living organisms. Taking advantage of the short wavelength and noninvasive nature, microwave sensing holds promise in detecting small foreign objects embedded in tissue based on their dielectric properties. However, the limiting factor is the trade-off between the penetration depth and the wavelength of the microwave signals. In this study, we investigate the feasibility of using microwave signals in the frequency range from 18 GHz to 40 GHz to detect centimeter to millimeter-scale metallic objects behind tissue-mimicking gelatin screens. The insights obtained from this work pave the way for the development of novel strategies for the localization of miniaturized medical robots using microwaves.
- 28 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (5) , 3506-3516
A Localization Method for Untethered Small-Scale Robots Using Electrical Impedance Tomography
Untethered small-scale robots can be potentially used in medical applications, such as minimally invasive surgeries and targeted drug delivery. This article introduces a new localization method using electrical impedance tomography, which is an emerging medical imaging technique, to dynamically track small-scale robots. The proposed approach provides the electrical conductivity distribution within the robot workspace from a set of electrical stimulations and voltage measurements gathered from eight electrodes placed at its boundary. The position of the robot can be deduced from the conductivity map that is reconstructed with the contrast in electrical properties between the robot and the background medium. This method is experimentally validated by successfully tracking the 2-D motion of four different magnetically actuated robots within a cylindrical arena (30 mm in diameter and 4.2 mm high). The smallest detected robot is 1.5 × 1.5 × 1 mm 3 . The proposed tracking method provides a noninvasive technology with low-cost and high-speed potential that would be significant and useful for the position feedback control of untethered devices for biomedical applications in the future.
- 28 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (5) , 3506-3516
A Localization Method for Untethered Small-Scale Robots Using Electrical Impedance Tomography
Untethered small-scale robots can be potentially used in medical applications, such as minimally invasive surgeries and targeted drug delivery. This article introduces a new localization method using electrical impedance tomography, which is an emerging medical imaging technique, to dynamically track small-scale robots. The proposed approach provides the electrical conductivity distribution within the robot workspace from a set of electrical stimulations and voltage measurements gathered from eight electrodes placed at its boundary. The position of the robot can be deduced from the conductivity map that is reconstructed with the contrast in electrical properties between the robot and the background medium. This method is experimentally validated by successfully tracking the 2-D motion of four different magnetically actuated robots within a cylindrical arena (30 mm in diameter and 4.2 mm high). The smallest detected robot is 1.5 × 1.5 × 1 mm 3 . The proposed tracking method provides a noninvasive technology with low-cost and high-speed potential that would be significant and useful for the position feedback control of untethered devices for biomedical applications in the future.
- 4 September 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (20) , 3665-3689
Positional dependence of particles and cells in microfluidic electrical impedance flow cytometry: origin, challenges and opportunities
In impedance cytometry, particle trajectory can influence the measurements obtained. In this review, the physical grounds of this dependence are explained and both the challenges and the opportunities induced by this phenomenon are discussed.
- 4 September 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (20) , 3665-3689
Positional dependence of particles and cells in microfluidic electrical impedance flow cytometry: origin, challenges and opportunities
In impedance cytometry, particle trajectory can influence the measurements obtained. In this review, the physical grounds of this dependence are explained and both the challenges and the opportunities induced by this phenomenon are discussed.