Xiangmeng Qu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiangmeng Qu has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
Haixia Zou
Key Laboratory of Sensing Technology and Biomedical Instruments of Guangdong Province and School of Biomedical Engineering, Sun Yat-Sen University, Shenzhen 518107, China
8 shared publicationsJunjie Yuan
Key Laboratory of Sensing Technology and Biomedical Instruments of Guangdong Province School of Biomedical Engineering Shenzhen Campus of Sun Yat‐Sen University Shenzhen Guangdong China
8 shared publicationsWentao Wang
Key Laboratory of Sensing Technology and Biomedical Instruments of Guangdong Province, School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen, Guangdong Province, 518017, China; The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, 510630, China
7 shared publicationsGuangpei Qi
Key Laboratory of Sensing Technology and Biomedical Instruments of Guangdong Province and School of Biomedical Engineering, Sun Yat-Sen University, Shenzhen 518107, China
6 shared publicationsYating Zhang
6 shared publicationsYizhou Jiang
Key Laboratory of Sensing Technology and Biomedical Instruments of Guangdong Province and School of Biomedical Engineering, Sun Yat-Sen University, Shenzhen 518107, China
6 shared publications
Latest Publications
- 20 August 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Fluorescence Event Counting for miRNA Detection Enabled by Surface-Confined Hybridization Chain Reaction with Integrated Optical Gain
MicroRNAs (miRNAs) are key biomarkers for disease diagnosis and biological research, yet their reliable quantification in complex samples remains challenging. Fluorescence-based detection is often limited by heterogeneous amplification efficiency and the inherent variability of intensity-based readouts, making measurements vulnerable to both biochemical and optical fluctuations. Although digital approaches such as digital PCR can mitigate some of this variability, they pose a significant barrier to access due to their reliance on specialized micro-partitioning devices and instrumentation. To address this, we developed an accessible, microscopy-based event-counting strategy. Our design integrates a microlens array for optical signal enhancement with a surface-confined hybridization chain reaction (HCR). This configuration transduces miRNA targets into spatially discrete, countable fluorescence events, enabling reproducible quantification under a unified imaging and analysis framework on a standard widefield microscope. The assay demonstrates log–log linearity from 10 fM to 1 nM and achieves detection limits of 2.36–3.34 fM for three model miRNAs (miR-21, miR-122, and miR-155). In a 50% serum matrix, it maintains accurate quantification with recoveries of 93–112%. By shifting the readout from error-prone analog intensity measurements to robust event counting, this work provides a scalable and accessible platform for miRNA profiling.
- 20 August 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Fluorescence Event Counting for miRNA Detection Enabled by Surface-Confined Hybridization Chain Reaction with Integrated Optical Gain
MicroRNAs (miRNAs) are key biomarkers for disease diagnosis and biological research, yet their reliable quantification in complex samples remains challenging. Fluorescence-based detection is often limited by heterogeneous amplification efficiency and the inherent variability of intensity-based readouts, making measurements vulnerable to both biochemical and optical fluctuations. Although digital approaches such as digital PCR can mitigate some of this variability, they pose a significant barrier to access due to their reliance on specialized micro-partitioning devices and instrumentation. To address this, we developed an accessible, microscopy-based event-counting strategy. Our design integrates a microlens array for optical signal enhancement with a surface-confined hybridization chain reaction (HCR). This configuration transduces miRNA targets into spatially discrete, countable fluorescence events, enabling reproducible quantification under a unified imaging and analysis framework on a standard widefield microscope. The assay demonstrates log–log linearity from 10 fM to 1 nM and achieves detection limits of 2.36–3.34 fM for three model miRNAs (miR-21, miR-122, and miR-155). In a 50% serum matrix, it maintains accurate quantification with recoveries of 93–112%. By shifting the readout from error-prone analog intensity measurements to robust event counting, this work provides a scalable and accessible platform for miRNA profiling.
Flexible ssDNA–DNA Tetrahedron FRET Sensor for Tumor Cell Discrimination via Intracellular Crowding
Intracellular crowding, a crucial biophysical parameter linked to tumor progression, can serve as a potential marker for phenotyping. Conventional intracellular crowding‐sensing approaches, particularly genetically encoded implementations, often rely on transfection reagents or other introduction procedures, which may perturb the native microenvironment and compromise measurement accuracy. Herein, we design a DNA biosensor with a DNA tetrahedron scaffold and a flexible ssDNA‐FRET element, achieving near‐physiological crowding sensing via a chemical‐driven soft‐matter response. Cy3/Cy5‐conjugated ssDNA aggregates more tightly with increased crowding, shortening the interfluorophore distance to trigger quantifiable FRET signals, validating the structure‐dependent correlation between flexible soft‐matter agglomeration and crowding degree via simulations, PEG experiments, and FRET characterization. The tetrahedron enables transfection‐agent‐free delivery, avoiding reagent drawbacks. We achieved multivariate statistical discrimination of six cell lines based on osmotic‐stress‐induced FRET fingerprints via osmotic pressure‐induced crowding variations, confirming cellular crowding as a hallmark of functional heterogeneity. This work advances soft matter‐based biosensing and tumor biophysics. [Correction added on October 10, 2026, after first online publication: The preceding sentence has been updated.]
Flexible ssDNA–DNA Tetrahedron FRET Sensor for Tumor Cell Discrimination via Intracellular Crowding
Intracellular crowding, a crucial biophysical parameter linked to tumor progression, can serve as a potential marker for phenotyping. Conventional intracellular crowding‐sensing approaches, particularly genetically encoded implementations, often rely on transfection reagents or other introduction procedures, which may perturb the native microenvironment and compromise measurement accuracy. Herein, we design a DNA biosensor with a DNA tetrahedron scaffold and a flexible ssDNA‐FRET element, achieving near‐physiological crowding sensing via a chemical‐driven soft‐matter response. Cy3/Cy5‐conjugated ssDNA aggregates more tightly with increased crowding, shortening the interfluorophore distance to trigger quantifiable FRET signals, validating the structure‐dependent correlation between flexible soft‐matter agglomeration and crowding degree via simulations, PEG experiments, and FRET characterization. The tetrahedron enables transfection‐agent‐free delivery, avoiding reagent drawbacks. We achieved multivariate statistical discrimination of six cell lines based on osmotic‐stress‐induced FRET fingerprints via osmotic pressure‐induced crowding variations, confirming cellular crowding as a hallmark of functional heterogeneity. This work advances soft matter‐based biosensing and tumor biophysics. [Correction added on October 10, 2026, after first online publication: The preceding sentence has been updated.]
- 4 April 2026
- Published by Springer Nature in Molecular and Cellular Biochemistry
- Vol. 481 (5) , 2139-2157
Downregulation of miR-194-5p impairs cardiomyocyte proliferation and differentiation through targeting Fign in congenital heart disease
- 4 April 2026
- Published by Springer Nature in Molecular and Cellular Biochemistry
- Vol. 481 (5) , 2139-2157
Downregulation of miR-194-5p impairs cardiomyocyte proliferation and differentiation through targeting Fign in congenital heart disease
- Open Access
- 18 March 2026
- Published by Elsevier in SSRN Electronic Journal
Flexible ssDNA Soft Matter-DNA Tetrahedron-FRET Sensor for AI-guided Tumor Cell Discrimination via Intracellular Crowding
Intracellular crowding, a crucial biophysical parameter linked to tumor progression, can serve as a potential marker for phenotyping. Existing sensors rely on transfection, which disrupts the intracellular microenvironment and reduces accuracy. Herein, we design a DNA biosensor with a DNA tetrahedron scaffold and a flexible ssDNA-FRET element, achieving near-physiological crowding sensing via a chemical-driven soft-matter response. Cy3/Cy5-conjugated ssDNA aggregates more tightly with increased crowding, shortening the interfluorophore distance to trigger quantifiable FRET signals, validating the structure-dependent correlation between flexible soft-matter agglomeration and crowding degree via simulations, PEG experiments, and FRET characterization. The tetrahedron enables transfection-agent-free delivery, avoiding reagent drawbacks. We achieved accurate AI-based discrimination of six tumor cell lines via osmotic pressure-induced crowding variations, confirming cellular crowding as a hallmark of functional heterogeneity. This work advances soft matter-based biosensing and tumor biophysics.
- 18 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessFlexible ssDNA Soft Matter-DNA Tetrahedron-FRET Sensor for AI-guided Tumor Cell Discrimination via Intracellular Crowding
Intracellular crowding, a crucial biophysical parameter linked to tumor progression, can serve as a potential marker for phenotyping. Existing sensors rely on transfection, which disrupts the intracellular microenvironment and reduces accuracy. Herein, we design a DNA biosensor with a DNA tetrahedron scaffold and a flexible ssDNA-FRET element, achieving near-physiological crowding sensing via a chemical-driven soft-matter response. Cy3/Cy5-conjugated ssDNA aggregates more tightly with increased crowding, shortening the interfluorophore distance to trigger quantifiable FRET signals, validating the structure-dependent correlation between flexible soft-matter agglomeration and crowding degree via simulations, PEG experiments, and FRET characterization. The tetrahedron enables transfection-agent-free delivery, avoiding reagent drawbacks. We achieved accurate AI-based discrimination of six tumor cell lines via osmotic pressure-induced crowding variations, confirming cellular crowding as a hallmark of functional heterogeneity. This work advances soft matter-based biosensing and tumor biophysics.
- 31 January 2026
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 300, 118470
Active-site rich nanostructure with dual-enhanced electron transfer for ultra-sensitive electrochemiluminescence detection of DNA methylation in colon cancer
- 31 January 2026
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 300, 118470
Active-site rich nanostructure with dual-enhanced electron transfer for ultra-sensitive electrochemiluminescence detection of DNA methylation in colon cancer
- 14 November 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 294, 118218
Simultaneously extracts and integrates cell morphology and cell surface protein expression for multimodal single-cell analysis
- 14 November 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 294, 118218
Simultaneously extracts and integrates cell morphology and cell surface protein expression for multimodal single-cell analysis
- 31 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (31) , 16812-16821
A Meta-Learning Approach for Multicenter and Small-Data Single-Cell Image Analysis
The application of algorithm-based single-cell imaging techniques can visualize and analyze cellular heterogeneity. However, algorithm-based single-cell imaging techniques are severely limited by the high workload required to label single-cell images and the high variation of cells from different sources. Herein, we propose a meta-learning approach for multicenter and small-data single-cell image analysis. Meta-learning combines automated wide-field fluorescence microscopy to build a hardware and software system to analyze cellular heterogeneity. We verified that the meta-learning single-cell imaging platform extracts the relevant information between multiple data centers through training to reduce the need for workload required to label single-cell images. The results show that the classification accuracy of the target task can reach about 92% using only 60% data volume labeled single-cell images. However, to achieve the same recognition accuracy, we need to use 100% data volume labeled single-cell images for traditional deep learning. Moreover, the accuracy achieved by our platform surpasses that of traditional deep learning methods, even when the data volume is reduced to 5%, which means our platform can significantly reduce the volume of single-cell image data labeling and the manual data labeling workload, thereby enhancing work efficiency and reducing work costs. Furthermore, our platform's robustness against data from different sources of single-cell images has been verified through knowledge migration experiments on public data sets. This robustness should instill confidence in the applicability of our platform across various research settings and data sources.
- 31 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (31) , 16812-16821
A Meta-Learning Approach for Multicenter and Small-Data Single-Cell Image Analysis
The application of algorithm-based single-cell imaging techniques can visualize and analyze cellular heterogeneity. However, algorithm-based single-cell imaging techniques are severely limited by the high workload required to label single-cell images and the high variation of cells from different sources. Herein, we propose a meta-learning approach for multicenter and small-data single-cell image analysis. Meta-learning combines automated wide-field fluorescence microscopy to build a hardware and software system to analyze cellular heterogeneity. We verified that the meta-learning single-cell imaging platform extracts the relevant information between multiple data centers through training to reduce the need for workload required to label single-cell images. The results show that the classification accuracy of the target task can reach about 92% using only 60% data volume labeled single-cell images. However, to achieve the same recognition accuracy, we need to use 100% data volume labeled single-cell images for traditional deep learning. Moreover, the accuracy achieved by our platform surpasses that of traditional deep learning methods, even when the data volume is reduced to 5%, which means our platform can significantly reduce the volume of single-cell image data labeling and the manual data labeling workload, thereby enhancing work efficiency and reducing work costs. Furthermore, our platform's robustness against data from different sources of single-cell images has been verified through knowledge migration experiments on public data sets. This robustness should instill confidence in the applicability of our platform across various research settings and data sources.
- 6 December 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (50) , 20015-20025
Highly Sensitive Multiplexed Sensing of miRNAs in a Gastric Cancer Patient’s Liquid Biopsy
Gastric cancer (GC) is one of the leading causes of cancer mortality in the world. Most patients are in the advanced stage of the disease at the time of diagnosis because the symptoms of early gastric cancer patients are not obvious. Early diagnosis of gastric cancer is still challenging due to the high cost, invasiveness, and low accuracy of traditional diagnostic methods such as endoscopy and biopsy. Herein, we develop clinically accurate and highly sensitive detection of multiple GC miRNA biomarkers in human serum using an isothermal nucleic acid primer exchange reaction (PER). The isothermal nucleic acid primer exchange reaction demonstrates high sensitivity and robustness, exemplified by a one-pot reaction achieving a detection limit of 28.71 fM. By quantifying the levels of three miRNA biomarkers selected through bioinformatics analysis in gastric cancer serum samples, the diagnostic approach effectively distinguished between clinical gastric cancer patients (n = 25) and noncancer controls (n = 10). The performance of our three-miRNA signature in discriminating between GC and controls was as follows: area under the curve (AUC): 0.808, sensitivity: 89%, specificity: 88%, positive predictive value (PPV): 96%, and negative predictive value (NPV): 70%.
- 6 December 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (50) , 20015-20025
Highly Sensitive Multiplexed Sensing of miRNAs in a Gastric Cancer Patient’s Liquid Biopsy
Gastric cancer (GC) is one of the leading causes of cancer mortality in the world. Most patients are in the advanced stage of the disease at the time of diagnosis because the symptoms of early gastric cancer patients are not obvious. Early diagnosis of gastric cancer is still challenging due to the high cost, invasiveness, and low accuracy of traditional diagnostic methods such as endoscopy and biopsy. Herein, we develop clinically accurate and highly sensitive detection of multiple GC miRNA biomarkers in human serum using an isothermal nucleic acid primer exchange reaction (PER). The isothermal nucleic acid primer exchange reaction demonstrates high sensitivity and robustness, exemplified by a one-pot reaction achieving a detection limit of 28.71 fM. By quantifying the levels of three miRNA biomarkers selected through bioinformatics analysis in gastric cancer serum samples, the diagnostic approach effectively distinguished between clinical gastric cancer patients (n = 25) and noncancer controls (n = 10). The performance of our three-miRNA signature in discriminating between GC and controls was as follows: area under the curve (AUC): 0.808, sensitivity: 89%, specificity: 88%, positive predictive value (PPV): 96%, and negative predictive value (NPV): 70%.