Min Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Min Kang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Jiaqiang Yang
Zhejiang University
2 shared publications - Hong Tian
School of Automation and Electrical Engineering, Zhejiang University of Science and Technology, Hangzhou 310023, China
1 shared publication - Jin Huang
State Key Laboratory of Advanced Electromagnetic Technology, Huazhong University of Science and Technology, Wuhan, China
1 shared publication Jincheng Luo
School of Automation and Electrical Engineering, Zhejiang University of Science and Technology, Hangzhou, China
1 shared publication- Qilan Huang
Department of Electrical Engineering, School of Automation and Electrical Engineering, Zhejiang University of Science and Technology, Hangzhou 310023, China
1 shared publication Weigang Wang
Hangzhou Fusheng Electrical Appliance, Co., Ltd., Hangzhou, China
1 shared publication
Latest Publications
- 24 October 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 26 (10) , 1-15
Digital current regulator based on predictive current active damping for ultra-high-speed PMSM drives
- 24 October 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 26 (10) , 1-15
Digital current regulator based on predictive current active damping for ultra-high-speed PMSM drives
- Open Access
- 1 September 2025
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Robotics and Automation (IJRA)
- Vol. 14 (3) , 438-450
Robot Gaussian-historical relocalization: inertial measurement unit-LiDAR likelihood field matching
Robot localization is a foundational technology for autonomous navigation, enabling task execution and adaptation to dynamic environments. However, failure to return to the correct pose after power loss or sudden displacement (the “kidnapping” problem) can lead to critical system failures. Existing methods often suffer from slow relocalization, high computational cost, and poor robustness to dynamic obstacles. We propose a novel inertial measurement unit (IMU)-LiDAR fusion relocalization framework based on Gaussian historical constraints and adaptive likelihood field matching. By incorporating IMU-derived yaw constraints and modeling historical poses within a 3σ Gaussian region, our method effectively narrows the LiDAR search space. Curvature and normal vector-based feature extraction reduces point cloud volume by 50–70%, while dynamic obstacle filtering via multi-frame differencing and neighborhood validation enhances robustness. An adaptive spiral search strategy further refines pose estimation. Compared to ORB-SLAM3 and adaptive Monte Carlo localization (AMCL), our method maintains comparable accuracy while significantly reducing relocalization time and CPU usage. Experimental results show a relocalization success rate of 84%, average time of 1.68 seconds, and CPU usage of 38.4%, demonstrating high efficiency and robustness in dynamic environments.
- 1 September 2025
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Robotics and Automation (IJRA)
- Vol. 14 (3) , 438-450
Open AccessRobot Gaussian-historical relocalization: inertial measurement unit-LiDAR likelihood field matching
Robot localization is a foundational technology for autonomous navigation, enabling task execution and adaptation to dynamic environments. However, failure to return to the correct pose after power loss or sudden displacement (the “kidnapping” problem) can lead to critical system failures. Existing methods often suffer from slow relocalization, high computational cost, and poor robustness to dynamic obstacles. We propose a novel inertial measurement unit (IMU)-LiDAR fusion relocalization framework based on Gaussian historical constraints and adaptive likelihood field matching. By incorporating IMU-derived yaw constraints and modeling historical poses within a 3σ Gaussian region, our method effectively narrows the LiDAR search space. Curvature and normal vector-based feature extraction reduces point cloud volume by 50–70%, while dynamic obstacle filtering via multi-frame differencing and neighborhood validation enhances robustness. An adaptive spiral search strategy further refines pose estimation. Compared to ORB-SLAM3 and adaptive Monte Carlo localization (AMCL), our method maintains comparable accuracy while significantly reducing relocalization time and CPU usage. Experimental results show a relocalization success rate of 84%, average time of 1.68 seconds, and CPU usage of 38.4%, demonstrating high efficiency and robustness in dynamic environments.
- Open Access
- 20 November 2024
- Published by MDPI AG in Electronics
- Vol. 13 (22) , 4572
Control Strategy for Disc Coreless Permanent Magnet Synchronous Motor with LC Filter
The disc coreless permanent magnet synchronous motor has the advantages of a short axial size, high power density, and small volume. Due to the coreless structure, its inductance is very small, which results in a serious current ripple and an unacceptable torque ripple if driven from a conventional inverter. This can be solved by installing an LC filter between the inverter and the motor. However, an undesirable resonance phenomenon is induced by the LC filter. In this paper, a new capacitive current feedback active damping (CCFAD) strategy is proposed. Instead of current sensors in the capacitor branch, a state observer is introduced to estimate the capacitance current. The observer is designed with double sliding mode surfaces, which reduces the order of the system. Compared to conventional capacitive current feedback, no additional current sensors are required, reducing the system cost. Besides the resonant harmonics, the phase current contains obvious fifth and seventh harmonics due to the special plane structure of the rotor. The proportional-integral-resonance (PIR) controller, instead of the traditional PI controller, is designed to suppress lower order harmonics. The experiment results show that current ripples due to resonance and rotor structure are suppressed significantly.
- 20 November 2024
- Published by MDPI AG in Electronics
- Vol. 13 (22) , 4572
Open AccessControl Strategy for Disc Coreless Permanent Magnet Synchronous Motor with LC Filter
The disc coreless permanent magnet synchronous motor has the advantages of a short axial size, high power density, and small volume. Due to the coreless structure, its inductance is very small, which results in a serious current ripple and an unacceptable torque ripple if driven from a conventional inverter. This can be solved by installing an LC filter between the inverter and the motor. However, an undesirable resonance phenomenon is induced by the LC filter. In this paper, a new capacitive current feedback active damping (CCFAD) strategy is proposed. Instead of current sensors in the capacitor branch, a state observer is introduced to estimate the capacitance current. The observer is designed with double sliding mode surfaces, which reduces the order of the system. Compared to conventional capacitive current feedback, no additional current sensors are required, reducing the system cost. Besides the resonant harmonics, the phase current contains obvious fifth and seventh harmonics due to the special plane structure of the rotor. The proportional-integral-resonance (PIR) controller, instead of the traditional PI controller, is designed to suppress lower order harmonics. The experiment results show that current ripples due to resonance and rotor structure are suppressed significantly.
- Open Access
- 3 March 2021
- Published by MDPI AG in Electronics
- Vol. 10 (5) , 591
Model Predictive Current Control of Multiphase Motor at Low Carrier Ratio
Multiphase motors have multiple control planes, and harmonics are decoupled in different planes. Multiphase motors can improve magnetic field distribution, power density and core utilization by injecting certain harmonic currents into the harmonic planes. In the harmonic plane control process, due to the switching frequency of the inverter being limited, the ratio of the switching frequency to the current frequency (the carrier ratio) of the harmonic plane is low, the digital control delay increases, and the inverter output current contains more harmonics, which makes it difficult for the proportional-integral (PI) current controller to effectively control the d-axis and q-axis currents of the harmonic plane and thus unable to track the given values stably. Moreover, the PI current controller is relatively dependent on the motor parameters. For these reasons, a model predictive current control method with predictive error compensation is proposed. Taking a nine-phase induction motor as an example, the control voltage is calculated by the cost function and corrected by the current predictive error, which realizes the current control method at a low carrier ratio. Additionally, the robustness of the control method is analyzed after the parameters of the multiphase motor have large errors. The experimental results show that the proposed method can control the current of the harmonic plane at low carrier ratio, accurately track the harmonic current commands and attain strong robustness for the motor parameters.
- 3 March 2021
- Published by MDPI AG in Electronics
- Vol. 10 (5) , 591
Open AccessModel Predictive Current Control of Multiphase Motor at Low Carrier Ratio
Multiphase motors have multiple control planes, and harmonics are decoupled in different planes. Multiphase motors can improve magnetic field distribution, power density and core utilization by injecting certain harmonic currents into the harmonic planes. In the harmonic plane control process, due to the switching frequency of the inverter being limited, the ratio of the switching frequency to the current frequency (the carrier ratio) of the harmonic plane is low, the digital control delay increases, and the inverter output current contains more harmonics, which makes it difficult for the proportional-integral (PI) current controller to effectively control the d-axis and q-axis currents of the harmonic plane and thus unable to track the given values stably. Moreover, the PI current controller is relatively dependent on the motor parameters. For these reasons, a model predictive current control method with predictive error compensation is proposed. Taking a nine-phase induction motor as an example, the control voltage is calculated by the cost function and corrected by the current predictive error, which realizes the current control method at a low carrier ratio. Additionally, the robustness of the control method is analyzed after the parameters of the multiphase motor have large errors. The experimental results show that the proposed method can control the current of the harmonic plane at low carrier ratio, accurately track the harmonic current commands and attain strong robustness for the motor parameters.
- 1 July 2007
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 8 (8) , 1311-1319
Analysis of a new 5-phase bearingless induction motor
This paper addresses the bearingless motor with a single set of multiphase windings. The interaction between M and M±1 pole-pair magnetic fields produces radial force. Based on this principle, a bearingless machine is obtained. Conventional bearingless machine has dual windings, levitation windings and torque windings, which produce the two magnetic fields. In the proposed bearingless motor, the two needed magnetic fields are produced by feeding two groups of currents to a single set of multiphase windings. Taking a 5-phase induction motor as example, the inductance matrices, considering air gap eccentricity, are calculated with the modified winding function method. The radial force analytical model is deduced by virtual displacement, and its results are validated by FEA. The mathematical model of the new bearingless machine is set up, and the simulation results verified the feasibility of this novel bearingless motor.
- 1 July 2007
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 8 (8) , 1311-1319
Analysis of a new 5-phase bearingless induction motor
This paper addresses the bearingless motor with a single set of multiphase windings. The interaction between M and M±1 pole-pair magnetic fields produces radial force. Based on this principle, a bearingless machine is obtained. Conventional bearingless machine has dual windings, levitation windings and torque windings, which produce the two magnetic fields. In the proposed bearingless motor, the two needed magnetic fields are produced by feeding two groups of currents to a single set of multiphase windings. Taking a 5-phase induction motor as example, the inductance matrices, considering air gap eccentricity, are calculated with the modified winding function method. The radial force analytical model is deduced by virtual displacement, and its results are validated by FEA. The mathematical model of the new bearingless machine is set up, and the simulation results verified the feasibility of this novel bearingless motor.