Vanina Costa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Vanina Costa has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Rafael Raya
Department of Information Technologies, Institute of Technology, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
5 shared publicationsLuis Perea
Albertia Servicios Sociosanitarios, Madrid, Spain
4 shared publicationsCristina Sánchez
Department of Information Technologies, Institute of Technology, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
3 shared publications- Rafael Raya
Departamento de TecnologÍas de la Información, Escuela Politécnica Superior, Universidad San Pablo-CEU, CEU Universities, Madrid, Spain
3 shared publications Abraham Otero
Universidad San Pablo-CEU
2 shared publications- Abraham Otero
Department of Information Technologies, Institute of Technology, Universidad San Pablo-CEU, CEU Universities, Campus Montepríncipe, 28660, Boadilla del Monte, Spain
2 shared publications
Latest Publications
- Open Access
- 1 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Feasibility of Meta Quest 2 for tracking upper-limb movements under varying field of view conditions: a pilot study
Measuring upper-limb movement using accessible motion capture (MoCap) technologies is of growing interest in rehabilitation and human motion analysis. While virtual reality (VR) systems offer an attractive alternative to traditional MoCap, their performance under realistic usage conditions remains insufficiently explored. In this pilot study, we provide a preliminary evaluation of the feasibility of the Meta Quest 2 as a motion tracking system by comparing wrist trajectories obtained from VR controllers with those measured using a Vicon optical MoCap system. Three healthy participants performed upper-limb movements under different head orientations, allowing the analysis of tracking performance when controllers were inside and outside the field of view (FOV) of the head-mounted display. Results show that trajectory similarity between systems is high when controllers remain within the FOV (correlation above [Formula: see text]) but decreases when controllers fall outside the visible area (down to [Formula: see text]). These findings highlight the strong dependence of inside-out VR tracking performance on FOV conditions. Overall, the Meta Quest 2 demonstrates feasible performance for capturing wrist trajectories during upper-limb movements, although tracking consistency is significantly affected by controller visibility. These preliminary results provide insight into the limitations of consumer VR systems for motion tracking in realistic scenarios and should be considered when applying such devices in applied contexts.
- 1 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessFeasibility of Meta Quest 2 for tracking upper-limb movements under varying field of view conditions: a pilot study
Measuring upper-limb movement using accessible motion capture (MoCap) technologies is of growing interest in rehabilitation and human motion analysis. While virtual reality (VR) systems offer an attractive alternative to traditional MoCap, their performance under realistic usage conditions remains insufficiently explored. In this pilot study, we provide a preliminary evaluation of the feasibility of the Meta Quest 2 as a motion tracking system by comparing wrist trajectories obtained from VR controllers with those measured using a Vicon optical MoCap system. Three healthy participants performed upper-limb movements under different head orientations, allowing the analysis of tracking performance when controllers were inside and outside the field of view (FOV) of the head-mounted display. Results show that trajectory similarity between systems is high when controllers remain within the FOV (correlation above [Formula: see text]) but decreases when controllers fall outside the visible area (down to [Formula: see text]). These findings highlight the strong dependence of inside-out VR tracking performance on FOV conditions. Overall, the Meta Quest 2 demonstrates feasible performance for capturing wrist trajectories during upper-limb movements, although tracking consistency is significantly affected by controller visibility. These preliminary results provide insight into the limitations of consumer VR systems for motion tracking in realistic scenarios and should be considered when applying such devices in applied contexts.
- Open Access
- 9 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 2503-2512
Design, Development, and Functional Validation of a 3D-Printed Passive Upper Limb Exoskeleton
Motor disability in children is evident in diagnoses such as cerebral palsy, muscular dystrophy, multiple sclerosis, or spinal muscular atrophy, among others, due to altered movement and postural patterns. This becomes more evident as the child grows and can be treated with physical therapy. The effectiveness of early interventions in facilitating an improvement in daily life activities varies depending on the child’s condition. In this context, the use of exoskeletons has emerged in recent years as a valuable resource for conducting more efficient therapy processes. This work describes the design (both structural and functional) and preliminary usability and functional validation of a 3D-printed passive upper limb exoskeleton. The goal is to provide clinicians with an efficient, low-cost device that is both easy to manufacture and assemble and, in a gamified environment, serves as an assistive device to physical therapy. The device features 5 degrees of freedom, enabling both a pro-gravity and an anti-gravity mode, controlled by a series of elastic bands. This gives rise to a dual operating mode, offering assistance or resistance to different arm, forearm, and shoulder-dependent movements. Usability validation conducted by exoskeleton users showed average results in all aspects rated above 3.8 out of 5, which implies levels of satisfaction between “quite satisfied” and “very satisfied”. The analysis of metrics recorded during therapy, such as the Hand Path Ratio and Success Rate (capturing user movements using an inertial sensor in the gamified environment), as well as the range of motion, reveals quantifiable improvements which can be attributed to the use of the exoskeleton: the Hand Path Ratio tended to approach 1 throughout sessions in almost all the users, the Success Rate remained stable (as users consistently were capable of completing the assigned tasks), and the range of motion showed that all patients achieved improvements of more than 10 degrees in some of the tested movements). These functional validation processes involved the participation of 7 children with varying levels of upper limb neuro-motor impairments.
- 9 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 2503-2512
Open AccessDesign, Development, and Functional Validation of a 3D-Printed Passive Upper Limb Exoskeleton
Motor disability in children is evident in diagnoses such as cerebral palsy, muscular dystrophy, multiple sclerosis, or spinal muscular atrophy, among others, due to altered movement and postural patterns. This becomes more evident as the child grows and can be treated with physical therapy. The effectiveness of early interventions in facilitating an improvement in daily life activities varies depending on the child’s condition. In this context, the use of exoskeletons has emerged in recent years as a valuable resource for conducting more efficient therapy processes. This work describes the design (both structural and functional) and preliminary usability and functional validation of a 3D-printed passive upper limb exoskeleton. The goal is to provide clinicians with an efficient, low-cost device that is both easy to manufacture and assemble and, in a gamified environment, serves as an assistive device to physical therapy. The device features 5 degrees of freedom, enabling both a pro-gravity and an anti-gravity mode, controlled by a series of elastic bands. This gives rise to a dual operating mode, offering assistance or resistance to different arm, forearm, and shoulder-dependent movements. Usability validation conducted by exoskeleton users showed average results in all aspects rated above 3.8 out of 5, which implies levels of satisfaction between “quite satisfied” and “very satisfied”. The analysis of metrics recorded during therapy, such as the Hand Path Ratio and Success Rate (capturing user movements using an inertial sensor in the gamified environment), as well as the range of motion, reveals quantifiable improvements which can be attributed to the use of the exoskeleton: the Hand Path Ratio tended to approach 1 throughout sessions in almost all the users, the Success Rate remained stable (as users consistently were capable of completing the assigned tasks), and the range of motion showed that all patients achieved improvements of more than 10 degrees in some of the tested movements). These functional validation processes involved the participation of 7 children with varying levels of upper limb neuro-motor impairments.
- Open Access
- 24 January 2023
- Published by Universitat Politecnica de Valencia in Revista Iberoamericana de Automática e Informática Industrial
- Vol. 20 (3) , 247-258
Rediseño basado en la experiencia clínica de un andador robótico para la rehabilitación de fractura de cadera
La fractura de cadera es una lesión frecuente en personas mayores de 65 años,estando asociada a una reducción en la esperanza de vida. Su rehabilitación se basa en la movilización gradual mediante terapia manual. Sin embargo, estos tratamientos no suelen ser integrales, constan de ejercicios repetitivos, resultan monótonos para el pacientey su seguimientoes principalmente cualitativo. SWalker es un andador robótico basado en un sistema de tracción y de soporte de peso, que integra sensores de marcha. Con una primera versión de este andador se llevó a cabo un estudio clínico que involucró 34 pacientes. A partir de esta experiencia se han extraído los requisitos de diseño que se consideran claves para el desarrollo de este tipo de dispositivos. Sobre la base de estos requisitos se ha construido una segunda versión del andador en la que se ha validado su usabilidad con 5 pacientes. Empleando la escala QUEST 2.0 se han comparado ambas versiones del andador, mostrando mejoras en la segunda versión en seguridad, adaptabilidad y usabilidad
- 24 January 2023
- Published by Universitat Politecnica de Valencia in Revista Iberoamericana de Automática e Informática Industrial
- Vol. 20 (3) , 247-258
Open AccessRediseño basado en la experiencia clínica de un andador robótico para la rehabilitación de fractura de cadera
La fractura de cadera es una lesión frecuente en personas mayores de 65 años,estando asociada a una reducción en la esperanza de vida. Su rehabilitación se basa en la movilización gradual mediante terapia manual. Sin embargo, estos tratamientos no suelen ser integrales, constan de ejercicios repetitivos, resultan monótonos para el pacientey su seguimientoes principalmente cualitativo. SWalker es un andador robótico basado en un sistema de tracción y de soporte de peso, que integra sensores de marcha. Con una primera versión de este andador se llevó a cabo un estudio clínico que involucró 34 pacientes. A partir de esta experiencia se han extraído los requisitos de diseño que se consideran claves para el desarrollo de este tipo de dispositivos. Sobre la base de estos requisitos se ha construido una segunda versión del andador en la que se ha validado su usabilidad con 5 pacientes. Empleando la escala QUEST 2.0 se han comparado ambas versiones del andador, mostrando mejoras en la segunda versión en seguridad, adaptabilidad y usabilidad
- Open Access
- 17 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 1340-1349
Development and Clinical Validation of a Rehabilitation Platform for Hip Fracture in Elderly Population
Hip fracture is one of the most common traumatisms associated with falls in the elderly, severely affecting the patient’s mobility and independence. In recent years, the use of robotic technology has proven to be effective in gait rehabilitation, especially for neurological disorders. However, there is a lack of research validating these devices for hip fracture in elderly patients. This paper presents the design and evaluation of a novel assistive platform for hip rehabilitation, SWalker, aimed at improving the rehabilitation of this condition. Functional validation of the SWalker platform was carried out with five healthy elderly subjects and two physiotherapists. Clinical validation was conducted with 34 patients with hip fracture. The control group ( $\text {n}=24$ , age $= 86.38\pm 6.16$ years, 75% female) followed conventional therapy, while the intervention group ( $\text{n}=10$ , age $= 86.80\pm 6.32$ years, 90% female) was rehabilitated using SWalker. The functional validation of the device reported good acceptability (System Usability Scale >85). In the clinical validation, the control group required 68.09±27.38 rehabilitation sessions compared to 22.60±16.75 in the intervention group ( $\text{p}< 0.001$ ). Patients in the control group needed 120.33±53.64 days to reach ambulation, while patients rehabilitated with SWalker achieved that stage in 67.11±51.07 days ( $\text{p}=0.021$ ). FAC and Tinetti indexes presented a larger improvement in the intervention group when compared with the control group ( $\text{p}=0.007$ and $\text{p}=0.01$ , respectively). The SWalker platform can be considered an effective tool to enhance autonomous gait and shorten rehabilitation therapy in elderly hip fracture patients. This result encourages further research on robotic rehabilitation platforms for hip fracture.
- 17 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 1340-1349
Open AccessDevelopment and Clinical Validation of a Rehabilitation Platform for Hip Fracture in Elderly Population
Hip fracture is one of the most common traumatisms associated with falls in the elderly, severely affecting the patient’s mobility and independence. In recent years, the use of robotic technology has proven to be effective in gait rehabilitation, especially for neurological disorders. However, there is a lack of research validating these devices for hip fracture in elderly patients. This paper presents the design and evaluation of a novel assistive platform for hip rehabilitation, SWalker, aimed at improving the rehabilitation of this condition. Functional validation of the SWalker platform was carried out with five healthy elderly subjects and two physiotherapists. Clinical validation was conducted with 34 patients with hip fracture. The control group ( $\text {n}=24$ , age $= 86.38\pm 6.16$ years, 75% female) followed conventional therapy, while the intervention group ( $\text{n}=10$ , age $= 86.80\pm 6.32$ years, 90% female) was rehabilitated using SWalker. The functional validation of the device reported good acceptability (System Usability Scale >85). In the clinical validation, the control group required 68.09±27.38 rehabilitation sessions compared to 22.60±16.75 in the intervention group ( $\text{p}< 0.001$ ). Patients in the control group needed 120.33±53.64 days to reach ambulation, while patients rehabilitated with SWalker achieved that stage in 67.11±51.07 days ( $\text{p}=0.021$ ). FAC and Tinetti indexes presented a larger improvement in the intervention group when compared with the control group ( $\text{p}=0.007$ and $\text{p}=0.01$ , respectively). The SWalker platform can be considered an effective tool to enhance autonomous gait and shorten rehabilitation therapy in elderly hip fracture patients. This result encourages further research on robotic rehabilitation platforms for hip fracture.
- Open Access
Evaluation of Child–Computer Interaction Using Fitts’ Law: A Comparison between a Standard Computer Mouse and a Head Mouse
This study evaluates and compares the suitability for child–computer interaction (CCI, the branch within human–computer interaction focused on interactive computer systems for children) of two devices: a standard computer mouse and the ENLAZA interface, a head mouse that measures the user’s head posture using an inertial sensor. A multidirectional pointing task was used to assess the motor performance and the users’ ability to learn such a task. The evaluation was based on the interpretation of the metrics derived from Fitts’ law. Ten children aged between 6 and 8 participated in this study. Participants performed a series of pre- and post-training tests for both input devices. After the experiments, data were analyzed and statistically compared. The results show that Fitts’ law can be used to detect changes in the learning process and assess the level of psychomotor development (by comparing the performance of adults and children). In addition, meaningful differences between the fine motor control (hand) and the gross motor control (head) were found by comparing the results of the interaction using the two devices. These findings suggest that Fitts’ law metrics offer a reliable and objective way of measuring the progress of physical training or therapy.
Open AccessEvaluation of Child–Computer Interaction Using Fitts’ Law: A Comparison between a Standard Computer Mouse and a Head Mouse
This study evaluates and compares the suitability for child–computer interaction (CCI, the branch within human–computer interaction focused on interactive computer systems for children) of two devices: a standard computer mouse and the ENLAZA interface, a head mouse that measures the user’s head posture using an inertial sensor. A multidirectional pointing task was used to assess the motor performance and the users’ ability to learn such a task. The evaluation was based on the interpretation of the metrics derived from Fitts’ law. Ten children aged between 6 and 8 participated in this study. Participants performed a series of pre- and post-training tests for both input devices. After the experiments, data were analyzed and statistically compared. The results show that Fitts’ law can be used to detect changes in the learning process and assess the level of psychomotor development (by comparing the performance of adults and children). In addition, meaningful differences between the fine motor control (hand) and the gross motor control (head) were found by comparing the results of the interaction using the two devices. These findings suggest that Fitts’ law metrics offer a reliable and objective way of measuring the progress of physical training or therapy.
- Open Access
- 3 March 2021
- Published by Springer Nature in Research Square
SWalker: a robotic platform for hip fracture rehabilitation
BackgroundHip fracture is one of the most common traumatisms associated with falls in the elderly, severely affecting the patient's mobility and independence. The treatment involves hospitalization and prolonged rehabilitation periods with high costs which are associated with an increased mortality rate due to health complications. In recent years, the use of robotic applications has proven to be effective in gait rehabilitation, especially for neurological disorders. However, there is a lack of research in robotic rehabilitation focused on hip fracture of elderly people. This paper presents the design and validation of a novel robotic platform for hip rehabilitation called SWalker aimed at improving the rehabilitation of this condition.MethodsThe performance of the SWalker platform was assessed at Albertia Servicios Sociosanitarios S.A. nursing homes. Preliminary functional validation of the SWalker platform was carried out with five healthy elderly subjects and two physiotherapists. Clinical validation was conducted with 34 hip fracture patients. The control group (n = 24, age = 86.38 ± 6.16, 75% female) followed conventional therapy, while the intervention group (n = 10, age = 86.80 ± 6.32, 90% female) was rehabilitated using SWalker. Physiological parameters, and functional assessment scales such as FAC and Tinetti were collected at the beginning and at the end of the intervention. Gait recovery and rehabilitation process indicators were also gathered.ResultsSWalker had a good acceptability in the functional validation (final scores > 85), as measured by the System Usability Scale. In the clinical validation, the control group required 68.09 ± 27.38 rehabilitation sessions compared to 22.60 ± 16.75 in the intervention group (p < 0.001). Patients in the control group needed 120.33 ± 53.64 days to reach ambulation, while patients rehabilitated with SWalker achieved that stage in 67.11 ± 51.07 days (p = 0.021). FAC and Tinetti indexes presented a larger improvement in the intervention group when compared with the control group (p = 0.007 and p = 0.01, respectively).ConclusionsThe SWalker platform can be considered an effective tool to enhance autonomous gait and shorten rehabilitation therapy in elderly hip fracture patients. This result encourages further research on robotic rehabilitation platforms for hip fracture.Trial registrationThis study was performed under the protocol “SWALKERS17”, approved on January 15, 2019 by the Local Ethical Committee of Fundación Jiménez Díaz. Public trial registration ISRCTN28049001 on February, 25 – Retrospectively registered, https://www.isrctn.com/ISRCTN28049001.
- 3 March 2021
- Published by Springer Nature in Research Square
Open AccessSWalker: a robotic platform for hip fracture rehabilitation
BackgroundHip fracture is one of the most common traumatisms associated with falls in the elderly, severely affecting the patient's mobility and independence. The treatment involves hospitalization and prolonged rehabilitation periods with high costs which are associated with an increased mortality rate due to health complications. In recent years, the use of robotic applications has proven to be effective in gait rehabilitation, especially for neurological disorders. However, there is a lack of research in robotic rehabilitation focused on hip fracture of elderly people. This paper presents the design and validation of a novel robotic platform for hip rehabilitation called SWalker aimed at improving the rehabilitation of this condition.MethodsThe performance of the SWalker platform was assessed at Albertia Servicios Sociosanitarios S.A. nursing homes. Preliminary functional validation of the SWalker platform was carried out with five healthy elderly subjects and two physiotherapists. Clinical validation was conducted with 34 hip fracture patients. The control group (n = 24, age = 86.38 ± 6.16, 75% female) followed conventional therapy, while the intervention group (n = 10, age = 86.80 ± 6.32, 90% female) was rehabilitated using SWalker. Physiological parameters, and functional assessment scales such as FAC and Tinetti were collected at the beginning and at the end of the intervention. Gait recovery and rehabilitation process indicators were also gathered.ResultsSWalker had a good acceptability in the functional validation (final scores > 85), as measured by the System Usability Scale. In the clinical validation, the control group required 68.09 ± 27.38 rehabilitation sessions compared to 22.60 ± 16.75 in the intervention group (p < 0.001). Patients in the control group needed 120.33 ± 53.64 days to reach ambulation, while patients rehabilitated with SWalker achieved that stage in 67.11 ± 51.07 days (p = 0.021). FAC and Tinetti indexes presented a larger improvement in the intervention group when compared with the control group (p = 0.007 and p = 0.01, respectively).ConclusionsThe SWalker platform can be considered an effective tool to enhance autonomous gait and shorten rehabilitation therapy in elderly hip fracture patients. This result encourages further research on robotic rehabilitation platforms for hip fracture.Trial registrationThis study was performed under the protocol “SWALKERS17”, approved on January 15, 2019 by the Local Ethical Committee of Fundación Jiménez Díaz. Public trial registration ISRCTN28049001 on February, 25 – Retrospectively registered, https://www.isrctn.com/ISRCTN28049001.
- Open Access
- 25 February 2021
- Published by Springer Nature
SWalker: a robotic platform to aid rehabilitation following hip fracture
- 25 February 2021
- Published by Springer Nature
Open AccessSWalker: a robotic platform to aid rehabilitation following hip fracture
- Open Access
Validity and reliability of inertial sensors for elbow and wrist range of motion assessment
Background: Elbow and wrist chronic conditions are very common among musculoskeletal problems. These painful conditions affect muscle function, which ultimately leads to a decrease in the joint’s Range Of Motion (ROM). Due to their portability and ease of use, goniometers are still the most widespread tool for measuring ROM. Inertial sensors are emerging as a digital, low-cost and accurate alternative. However, whereas inertial sensors are commonly used in research studies, due to the lack of information about their validity and reliability, they are not widely used in the clinical practice. The goal of this study is to assess the validity and intra-inter-rater reliability of inertial sensors for measuring active ROM of the elbow and wrist. Materials and Methods: Measures were taken simultaneously with inertial sensors (Werium™ system) and a universal goniometer. The process involved two physiotherapists (“rater A” and “rater B”) and an engineer responsible for the technical issues. Twenty-nine asymptomatic subjects were assessed individually in two sessions separated by 48 h. The procedure was repeated by rater A followed by rater B with random order. Three repetitions of each active movement (elbow flexion, pronation, and supination; and wrist flexion, extension, radial deviation and ulnar deviation) were executed starting from the neutral position until the ROM end-feel; that is, until ROM reached its maximum due to be stopped by the anatomy. The coefficient of determination (r2) and the Intraclass Correlation Coefficient (ICC) were calculated to assess the intra-rater and inter-rater reliability. The Standard Error of the Measurement and the Minimum Detectable Change and a Bland–Altman plots were also calculated. Results: Similar ROM values when measured with both instruments were obtained for the elbow (maximum difference of 3° for all the movements) and wrist (maximum difference of 1° for all the movements). These values were within the normal range when compared to literature studies. The concurrent validity analysis for all the movements yielded ICC values ≥0.78 for the elbow and ≥0.95 for the wrist. Concerning reliability, the ICC values denoted a high reliability of inertial sensors for all the different movements. In the case of the elbow, intra-rater and inter-rater reliability ICC values range from 0.83 to 0.96 and from 0.94 to 0.97, respectively. Intra-rater analysis of the wrist yielded ICC values between 0.81 and 0.93, while the ICC values for the inter-rater analysis range from 0.93 to 0.99. Conclusions: Inertial sensors are a valid and reliable tool for measuring elbow and wrist active ROM. Particularly noteworthy is their high inter-rater reliability, often questioned in measurement tools. The lowest reliability is observed in elbow prono-supination, probably due to skin artifacts. Based on these results and their advantages, inertial sensors can be considered a valid assessment tool for wrist and elbow ROM.
Open AccessValidity and reliability of inertial sensors for elbow and wrist range of motion assessment
Background: Elbow and wrist chronic conditions are very common among musculoskeletal problems. These painful conditions affect muscle function, which ultimately leads to a decrease in the joint’s Range Of Motion (ROM). Due to their portability and ease of use, goniometers are still the most widespread tool for measuring ROM. Inertial sensors are emerging as a digital, low-cost and accurate alternative. However, whereas inertial sensors are commonly used in research studies, due to the lack of information about their validity and reliability, they are not widely used in the clinical practice. The goal of this study is to assess the validity and intra-inter-rater reliability of inertial sensors for measuring active ROM of the elbow and wrist. Materials and Methods: Measures were taken simultaneously with inertial sensors (Werium™ system) and a universal goniometer. The process involved two physiotherapists (“rater A” and “rater B”) and an engineer responsible for the technical issues. Twenty-nine asymptomatic subjects were assessed individually in two sessions separated by 48 h. The procedure was repeated by rater A followed by rater B with random order. Three repetitions of each active movement (elbow flexion, pronation, and supination; and wrist flexion, extension, radial deviation and ulnar deviation) were executed starting from the neutral position until the ROM end-feel; that is, until ROM reached its maximum due to be stopped by the anatomy. The coefficient of determination (r2) and the Intraclass Correlation Coefficient (ICC) were calculated to assess the intra-rater and inter-rater reliability. The Standard Error of the Measurement and the Minimum Detectable Change and a Bland–Altman plots were also calculated. Results: Similar ROM values when measured with both instruments were obtained for the elbow (maximum difference of 3° for all the movements) and wrist (maximum difference of 1° for all the movements). These values were within the normal range when compared to literature studies. The concurrent validity analysis for all the movements yielded ICC values ≥0.78 for the elbow and ≥0.95 for the wrist. Concerning reliability, the ICC values denoted a high reliability of inertial sensors for all the different movements. In the case of the elbow, intra-rater and inter-rater reliability ICC values range from 0.83 to 0.96 and from 0.94 to 0.97, respectively. Intra-rater analysis of the wrist yielded ICC values between 0.81 and 0.93, while the ICC values for the inter-rater analysis range from 0.93 to 0.99. Conclusions: Inertial sensors are a valid and reliable tool for measuring elbow and wrist active ROM. Particularly noteworthy is their high inter-rater reliability, often questioned in measurement tools. The lowest reliability is observed in elbow prono-supination, probably due to skin artifacts. Based on these results and their advantages, inertial sensors can be considered a valid assessment tool for wrist and elbow ROM.