Dimitris Karagkiozidis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dimitris Karagkiozidis has a total of 158 co-authors. Here are the top co-authors by number of shared publications:
- Alkiviadis Bais
Laboratory of Atmospheric Physics, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece
34 shared publications - Dimitris Balis
Laboratory of Atmospheric Physics, Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
20 shared publications Michel Van Roozendael
20 shared publications- Andreas Richter
Institute of Environmental Physics (IUP), University of Bremen, Bremen, Germany
13 shared publications François Hendrick
Royal Belgian Institute for Space Aeronomy (BIRA-IASB), 1180 Brussels, Belgium
12 shared publications- Dimitris Nikolis
Laboratory of Atmospheric Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
11 shared publications
Latest Publications
- Open Access
- 1 June 2026
- Published by Elsevier in Atmospheric Environment
- Vol. 382
Three years of MAX-DOAS observations of glyoxal and formaldehyde in Thessaloniki, Greece
- 1 June 2026
- Published by Elsevier in Atmospheric Environment
- Vol. 382
Open AccessThree years of MAX-DOAS observations of glyoxal and formaldehyde in Thessaloniki, Greece
- Open Access
- 22 May 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (10) , 3309-3332
Ground-based total ozone column measurements in the Huggins and Chappuis bands using Direct-Sun DOAS observations
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (UV, Huggins bands) and visible (VIS, Chappuis bands) spectral regions using direct sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the research-grade UV-VIS DOAS system Delta, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference spectrum using the Langley plot and the Minimum-Amount Langley-Extrapolation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of −0.44 % and Pearson's correlation coefficient R= 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R>0.98), with median biases of −0.18 % and −0.63 % for the VIS and 0.08 % and −0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of TOC were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles or at high-latitude locations, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- 22 May 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (10) , 3309-3332
Open AccessGround-based total ozone column measurements in the Huggins and Chappuis bands using Direct-Sun DOAS observations
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (UV, Huggins bands) and visible (VIS, Chappuis bands) spectral regions using direct sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the research-grade UV-VIS DOAS system Delta, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference spectrum using the Langley plot and the Minimum-Amount Langley-Extrapolation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of −0.44 % and Pearson's correlation coefficient R= 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R>0.98), with median biases of −0.18 % and −0.63 % for the VIS and 0.08 % and −0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of TOC were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles or at high-latitude locations, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- Open Access
- 24 March 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-36
Reply on RC3
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- 24 March 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-36
Open AccessReply on RC3
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- Open Access
- 24 March 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-36
Reply on RC2
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- 24 March 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-36
Open AccessReply on RC2
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- Open Access
- 24 March 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-36
Reply on RC1
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- 24 March 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-36
Open AccessReply on RC1
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- Open Access
- 27 January 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-36
Comment on egusphere-2025-5627
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- 27 January 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-36
Open AccessComment on egusphere-2025-5627
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- Open Access
- 26 January 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-36
Comment on egusphere-2025-5627
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- 26 January 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-36
Open AccessComment on egusphere-2025-5627
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- Open Access
- 21 January 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-36
Comment on egusphere-2025-5627
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- 21 January 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-36
Open AccessComment on egusphere-2025-5627
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- Open Access
- 5 January 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-36
Ground-based total ozone column measurements in the Huggins and Chappuis bands using Direct-Sun DOAS observations
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- 5 January 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-36
Open AccessGround-based total ozone column measurements in the Huggins and Chappuis bands using Direct-Sun DOAS observations
Accurate routine monitoring of the Total Ozone Column (TOC) is essential for understanding ozone temporal variability, assessing long-term trends and supporting satellite validation. In this work, we present TOC retrievals in both ultraviolet (Huggins bands) and visible (Chappuis bands) spectral regions using direct-sun Differential Optical Absorption Spectroscopy (DS-DOAS). We use the Delta UV–VIS DOAS system, recently designed and operated at the Laboratory of Atmospheric Physics in Thessaloniki, Greece. A dedicated retrieval algorithm was developed that includes the calibration of a measured reference DS spectrum using the Langley plot and Bootstrap Estimation approaches. The analysis suggests that TOCs derived from the visible channel for the first time in Thessaloniki are highly consistent with those from the ultraviolet channel, with a median difference of –0.44 % and Pearson's correlation coefficient R = 0.97. The Delta TOC retrievals were compared with two collocated instruments, Brewer and Pandora, yielding very good agreement in both spectral regions (R > 0.98), with median biases –0.18 % and –0.63 % for the VIS and 0.08 % and –0.32 % for the UV channel compared to the Brewer and Pandora, respectively. The seasonal and diurnal variabilities of total ozone were captured consistently from all three instruments, confirming the robustness of the retrievals. Enhanced aerosol loads, such as those observed during an extreme wildfire event, introduced significant deviations in the VIS TOC comparisons with the reference instruments, while the comparisons in the UV remained largely unaffected. The findings of this study confirm the capability of Delta to provide accurate and consistent TOC retrievals in both UV and VIS spectral bands. The successful exploitation of the Chappuis bands extends the applicability of DS-DOAS to conditions where UV sensitivity is limited, such as at high solar zenith angles, thereby extending the continuity of ozone monitoring from ground-based systems and providing a complementary approach to traditional UV-based TOC retrievals.
- Open Access
- 5 January 2026
- Published by Copernicus GmbH
Supplementary material to "Ground-based total ozone column measurements in the Huggins and Chappuis bands using Direct-Sun DOAS observations"
- 5 January 2026
- Published by Copernicus GmbH
Open AccessSupplementary material to "Ground-based total ozone column measurements in the Huggins and Chappuis bands using Direct-Sun DOAS observations"