Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marc Jofre has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Nonlinear Microwave Microfluidic High-Sensitivity Triresonant Biosensor for Discrimination of Functional States of the E. coli

    by Houda Ataa Allah, Fatima Ataa Allah, César Palacios-Arias, Mariem Aznabet, Otman EL Mrabet, Marc Jofre, Jordi Romeu, Luis Jofre-Roca

  • Open Access

    Multiplane Sub-Nanosecond Timing via SyncE/PTP Enabling 12.5 Mqb/s Synchronous TDMA in Quantum Networks

    by Marc Jofre, Anna Agustí-Torra, David Rincón-Rivera

    Telecom standards efficiently enable time synchronization mechanisms in multi-node Quantum Networks (QNs) by combining Synchronous Ethernet (SyncE) and Precision Time Protocol (PTP). The architecture explored in this work utilizes SyncE to provide all connected nodes with a stable and precise frequency reference, adjustable in the range from 1 Hz to 125MHz, obtaining sub-nanosecond temporal jitter in the real-time/quantum plane. This reference is complemented with PTP to provide a distributed time reference for synchronization with a microsecond-level temporal allocation capability. In particular, in the control plane, PTP enables time division multiple access (TDMA) for sharing the quantum channel in multi-node quantum networks QNs. It is demonstrated that the proposed architecture achieves nanosecond synchronous transfer in the real-time/quantum plane and allocates microsecond time windows through the control plane. The theoretical model and experimental results validate performing common quantum communications operations with 98% fidelity and 10−2 quantum bit error rate (QBER) at an emission rate of 12.5 Mqb/s. The results confirm that SyncE/PTP synchronization is a viable and scalable solution for future multi-node QN infrastructures.

  • Split-Ring Resonator Based Microwave Microfluidic Biosensor for Single Bioparticle Position Location and Live/Dead Cell Differentiation

    by Houda Ataa Allah, Fatima Ataa Allah, César Palacios-Arias, Mariem Aznabet, Otman EL Mrabet, Marc Jofre, Jordi Romeu, Luis Jofre-Roca

    This paper presents a novel microwave biosensor integrated with a microfluidic platform for the label-free detection and differentiation of biological particles, including live and dead Escherichia coli (E. coli). The sensor is based on a 50 $\Omega$ microstrip line coupled to an annular split-ring resonator (SRR), designed and fabricated for a high sensitivity response to changes in the dielectric properties on the bioparticle. The integration with a microfluidic channel allows precise control and delivery of biological samples to the sensing region. Experiments demonstrated the sensor’s ability to detect individual microbeads and distinguish between single live and dead bacterial cells through measurable shifts in resonance frequency. Furthermore, by applying an Inverse Fast Fourier Transform (IFFT) to the differential transmission parameter, the system enables the spatial localization of single particles within the microfluidic channel. The results indicate significant potential for point-of-care diagnostics and environmental monitoring applications, highlighting the advantages of microwave biosensing for real-time, single-particle analysis.


  • Open Access

    Qubit Rate Modulation-Based Time Synchronization Mechanism for Multinode Quantum Networks

    by Marc Jofre

    The combination of Quantum and Telecommunication networks enables to revolutionize the way we make use of information, offering unparalleled capabilities and making it an ideal choice for many critical applications. In this sense, quantum protocols generally have a unique requirement to have strict time synchronization in order to operate, which generally consume quantum resources of part of the exchanged qubits. Accordingly, in this work we demonstrate and characterize a temporal alignment mechanism for quantum networks based on frequency testing, allowing to preserve the quantum state of qubits. The time synchronization correction achieved is within 100 ns working at 5 MHz with temporal and relative frequency offsets commonly acquired in quantum links using conventional hardware clocks with temporal stability in the range of $10^{-8}$ and 200 ns jitter.


  • Open Access

    Nonlinear Microwave Susceptibility Measurements Using Intermodulation Products on a Microfluidic Platform

    by César Palacios-Arias, Marc Jofre, María-José López, Youness Akazzim, Lluis Jofre, Jordi Romeu, Luis Jofre-Roca

    Measuring the nonlinear responses of living cells has enabled an understanding of their behavior and functionality. Currently, this response has been studied at radio and optical frequencies, leaving an unexplored gap in the microwave field. This study presents a system that combines microwave technology with a microfluidic platform to measure the nonlinear susceptibility of living organisms to electromagnetic fields. The applied technique involved feeding the system with two tones (2.1 GHz and 4 GHz) to generate third-order intermodulation products (PIMP) at 5.9 GHz. Nonlinear susceptibility was measured from the power levels of PIMP using a spectrum analyzer. Broadband electrodes based on slot bowtie geometry were manufactured to operate at 5 GHz with a bandwidth of 4 GHz. Additionally, an engineering process is presented to optimize the power of the internal mixer of the spectrum analyzer to obtain the maximum dynamic range and improve the sensitivity of the system. Nonlinear susceptibility to microwaves was analyzed in four samples, including pure ethanol, a mixture of ethanol and dimethyl-sulfoxide (DMSO), live Escherichia coli (E. coli), and heat-killed E. coli. The results show that ethanol has zero nonlinear susceptibility, whereas when it is mixed with DMSO, a nonlinear response appears with a value of 4 dB with respect to the nonlinear susceptibility of the system in the absence of a sample. Finally, the nonlinear susceptibility of live E. coli to microwaves was detected with a difference of 8 dB over the reference value and 6 dB with respect to the heat-killed E. coli sample.


  • Magnetoelectric Dipole Antenna Framework Supporting Orbital Angular Momentum Modes

    by Marc Jofre, Youness Akazzim, Sebastián Blanch, Jordi Romeu, Bedri A. Cetiner, Luis Jofre-Roca

    The ability to utilize resources to meet the need of growing diversity of communication services and user behavior marks the future of cognitive wireless communication systems. Cognitive wireless technologies for vehicular communications, in combination with Orbital Angular Momentum (OAM) modes aim at extending Non-Line-Of-Sight (NLOS) short-distance communications for smart mobility. In this regard, OAM antenna frameworks need to be developed to support these technologies. In this work, we describe a magnetoelectric dipole antenna framework supporting OAM modes. The framework is derived from moment tensors of specific vector spherical harmonic functions synthesized from dipoles. The antenna framework is discussed in terms of OAM generation, and it is validated numerically and experimentally for l = 1 OAM mode, achieving more than 500MHz operation bandwidth at the frequency of operation of 3.5GHz. Also, for l = 1 OAM mode, the null aligns precisely with the anticipated dimensions numerically computed.


  • Open Access

    UWB Microwave Functional Brain Activity Extraction for Parkinson’s Disease Monitoring

    by Youness Akazzim, César Palacios Arias, Marc Jofre, Otman EL Mrabet, Jordi Romeu, Luis Jofre-Roca

    Microwaves have proven their imaging capabilities to visualize the body composition for medical applications thanks to their penetration inside biological structures. In this context, this paper presents a novel methodology that aims to extract not just the internal morphology but also the brain’s functional activity using the UWB Pulse Amplitude Modulation (PAM) technique to have simultaneously functional monitoring and imaging capability and apply it to monitor the Parkinson’s disease. The radiofrequency system is composed of two orthogonal sets of double UWB probes operating in the frequency range of 0.5 GHz - 1.5 GHz. An experimental set-up has been devised that avoids complex in-vivo testing, albeit allows a system proof-of-concept validation. A bio-tag consisting of an optically modulated photodiode is used to emulate local medium changes associated to cell activity. The proposed system is used to first extract the modeled brain Action Potential (AP) to validate the performance of the bio-tag, and then to monitor the Parkinson’s disease (PD) based on the beta frequency band character within basal ganglia–thalamocortical (BGTC) which is a key marker for the PD. The results show a good capability of locating and differentiating the signals generated within the phantom by the bio-tag, alternatively emulating the healthy and PD’s state, based on the frequency. The obtained results of the functional monitoring technique on distinguishing the healthy from non-healthy brain model activity, as well as in the phantom mimicking the average proprieties of a human head, will serve as a basis for detecting functional diseases in the future.


  • Microwave Contactless Current-Sensing for Live/Dead Differentiation of Single Bioparticles on a Microfluidic Platform

    by César Palacios Arias, Marc Jofre, Lluís Jofre, Jordi Romeu, Luis Jofre-Roca

    The combination of microwave and microfluidic technologies enables the creation of efficient platforms to rapidly quantify live/dead bioparticles in industrial processes, biomedical research and environmental monitoring applications. In this regard, this work demonstrates the differentiation of single live/dead bioparticles with a microwave-microfluidic platform. The system is composed of a contactless current-sensing superheterodyne architecture with broadband frequency-operation bowtie electrodes. Furthermore, the 20mm × 20mm bowtie electrode has been designed and manufactured with a –10 dB frequency range, from 4GHz to 8GHz, and capable of confining the electric field in a micrometric volume. The gap of the bowtie geometry of the electrodes is adjusted to the dimensions of the 50 μm × 50 μm cross-section and 40mm long microfluidic channel. In particular, 10mL sample with 10 9 bacteria/mL flows through the microchannel at 19.8 μL/min, focused with elasto-inertial effect enhanced with 500 ppm of polyethylene oxide. Accordingly, from the signal captured by the electrodes, the energy variation of the applied electric field produced by the bioparticles is sensed by a current-based transimpedance amplifier. Here, the incorporation of the transimpedance amplifier in the measurement system improves the SNR by 4 dB. In addition, the superheterodyne transceiver has been optimized in terms of local oscillator power and bandwidth. Furthermore, the microfluidic system has been adjusted so that the balance of hydrodynamic forces confines bioparticles at the centerline of the microchannel within less than 5 μm. As a result, the system measures the cytoplasmic content of live and dead flowing bacteria with a difference of 6 dB and relative deviation of 3.2%.


  • Open Access

    Optically Pumped Magnetometer with High Spatial Resolution Magnetic Guide for the Detection of Magnetic Droplets in a Microfluidic Channel

    by Marc Jofre, Jordi Romeu, Luis Jofre-Roca

    Quantum sensors provide unprecedented magnetic field detection sensitivities, enabling these to extend the common magnetometry range of applications and environments of operation. In this framework, many applications also require high spatial resolution magnetic measurements for biomedical research, environmental monitoring and industrial production. In this regard, Optically Pumped Magnetometers (OPMs) are considered as prominent candidates, but are impaired in size with micrometer scale magnetic particles, e.g. magnetic droplets. In order to address this limitation, here we study the effects of adding a micrometer-to-millimeter magnetic guide to a miniature OPM. This device is applied to detect Fe3O4 magnetic droplets flowing at rates up to $25$ drop./s in a microfluidic channel. The computed spatial resolution is $300$ $μ$m and the measured SNR is larger than $15$ dB for the different sizes of considered magnetic droplets.