Ole Numssen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ole Numssen has a total of 126 co-authors. Here are the top co-authors by number of shared publications:
- Konstantin Weise
Methods and Development Group Brain Networks, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
18 shared publications - Gesa Hartwigsen
Research Group Cognition and Plasticity, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
17 shared publications - Thomas R. Knösche
Methods and Development Group Brain Networks, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
14 shared publications Gesa Hartwigsen
Research Group Cognition and Plasticity, Max Planck Institute for Human Cognitive and Brain Sciences, Stephanstr. 1a, 04103, Leipzig, Germany
11 shared publicationsThomas R. Knösche
Methods and Development Group Brain Networks, Max Planck Institute for Human Cognitive and Brain Sciences, Stephanstr. 1a, 04103, Leipzig, Germany
7 shared publicationsKonstantin Weise
Methods and Development Group Brain Networks, Max Planck Institute for Human Cognitive and Brain Sciences, Stephanstr. 1a, 04103, Leipzig, Germany
5 shared publications
Latest Publications
- Open Access
Executive and language systems competitively shape predictive processing during reading
When we read, our brains constantly generate predictions about upcoming words, which is thought to make comprehension faster and more efficient. Yet it remains unclear whether this predictive mechanism relies on the same domain-general executive resources the brain uses for other demanding cognitive tasks, or operates largely independently within the language system. Here we tested this question using transcranial magnetic stimulation (TMS) in twenty-five healthy adults, who performed self-paced naturalistic reading, an n-back task, and a dual task of concurrent reading and n-back, allowing us to place competing demands on cognitive resources. In three sessions, we stimulated the left angular gyrus alone, the angular gyrus together with dorsolateral prefrontal cortex, a hub of executive control, or delivered sham stimulation, and used computational modeling of decision-making to isolate how each brain state altered the underlying cognitive processes. Combined stimulation of the angular gyrus and prefrontal cortex selectively weakened the reading-time costs of unexpected words, but only when reading competed with the working-memory task, revealing that linguistic prediction draws on executive resources specifically under cognitive load. Computational models showed that the relationship was bidirectional: Unpredictable words also disrupted concurrent working-memory decisions, slowing the accumulation of evidence and increasing response caution. Together, these findings show that predictive language processing is not a fixed, encapsulated function but is dynamically coupled to executive control when cognitive demands compete. Our results provide evidence that prediction during language comprehension is embedded within a broader, demand-sensitive cognitive architecture that flexibly coordinates linguistic and executive resources.
Open AccessExecutive and language systems competitively shape predictive processing during reading
When we read, our brains constantly generate predictions about upcoming words, which is thought to make comprehension faster and more efficient. Yet it remains unclear whether this predictive mechanism relies on the same domain-general executive resources the brain uses for other demanding cognitive tasks, or operates largely independently within the language system. Here we tested this question using transcranial magnetic stimulation (TMS) in twenty-five healthy adults, who performed self-paced naturalistic reading, an n-back task, and a dual task of concurrent reading and n-back, allowing us to place competing demands on cognitive resources. In three sessions, we stimulated the left angular gyrus alone, the angular gyrus together with dorsolateral prefrontal cortex, a hub of executive control, or delivered sham stimulation, and used computational modeling of decision-making to isolate how each brain state altered the underlying cognitive processes. Combined stimulation of the angular gyrus and prefrontal cortex selectively weakened the reading-time costs of unexpected words, but only when reading competed with the working-memory task, revealing that linguistic prediction draws on executive resources specifically under cognitive load. Computational models showed that the relationship was bidirectional: Unpredictable words also disrupted concurrent working-memory decisions, slowing the accumulation of evidence and increasing response caution. Together, these findings show that predictive language processing is not a fixed, encapsulated function but is dynamically coupled to executive control when cognitive demands compete. Our results provide evidence that prediction during language comprehension is embedded within a broader, demand-sensitive cognitive architecture that flexibly coordinates linguistic and executive resources.
- Open Access
One placement, many fields: robust voxel-wise mapping with multichannel TMS
Understanding the human brain at the individual level is central to understanding its function and a prerequisite for personalized therapy. Transcranial magnetic stimulation (TMS) can map structure–function relationships at high resolution by regressing trial-wise variation in the TMS-induced electric field (E-field) against a response such as motor evoked potentials (MEPs). This requires distinct E-fields across pulses at different cortical locations, which single-coil TMS (sTMS) achieves by physically repositioning the coil—increasingly reliant on robotic guidance and capped by the coil geometry. Multichannel TMS (mTMS) instead steers the E-field electronically via independent currents in several coils, opening a design space of high variability without physical repositioning. We adapt determinant-based sequence optimization from discrete sTMS coil-placement sets to the continuous mTMS current space (D-optimal design), identifying pulse sequences whose induced cortical E-fields are as mutually dissimilar as biophysical constraints allow. We benchmarked optimized mTMS sequences against random baselines and optimized sTMS placements in virtual motor mapping across multiple head models, assessing three mTMS array geometries (5-channel planar, 6- and 12-channel spherical), two figure-of-eight sTMS coils, and varying pulse counts, response noise, and cortical depth. D-optimal mTMS currents substantially outperformed random currents and optimized sTMS at matched pulse counts. The gain was modest without noise but increased significantly with it: at the highest noise level, optimized sTMS failed to converge after 100 pulses (∼20–22 mm error), whereas all mTMS arrays reached median errors at or below 6 mm. mTMS also recovered deep targets better than sTMS (up to 35 mm skin–cortex distance, versus 25 mm) and performed uniformly across the region of interest. In addition, we found that a coil-space scheme based only on the magnetic vector potential, precomputable once per array without per-subject MRI, captured most of the benefit, matching subject-specific optimization at 100 pulses. mTMS thus makes voxel-wise mapping robust throughout a region of interest without coil repositioning.
Open AccessOne placement, many fields: robust voxel-wise mapping with multichannel TMS
Understanding the human brain at the individual level is central to understanding its function and a prerequisite for personalized therapy. Transcranial magnetic stimulation (TMS) can map structure–function relationships at high resolution by regressing trial-wise variation in the TMS-induced electric field (E-field) against a response such as motor evoked potentials (MEPs). This requires distinct E-fields across pulses at different cortical locations, which single-coil TMS (sTMS) achieves by physically repositioning the coil—increasingly reliant on robotic guidance and capped by the coil geometry. Multichannel TMS (mTMS) instead steers the E-field electronically via independent currents in several coils, opening a design space of high variability without physical repositioning. We adapt determinant-based sequence optimization from discrete sTMS coil-placement sets to the continuous mTMS current space (D-optimal design), identifying pulse sequences whose induced cortical E-fields are as mutually dissimilar as biophysical constraints allow. We benchmarked optimized mTMS sequences against random baselines and optimized sTMS placements in virtual motor mapping across multiple head models, assessing three mTMS array geometries (5-channel planar, 6- and 12-channel spherical), two figure-of-eight sTMS coils, and varying pulse counts, response noise, and cortical depth. D-optimal mTMS currents substantially outperformed random currents and optimized sTMS at matched pulse counts. The gain was modest without noise but increased significantly with it: at the highest noise level, optimized sTMS failed to converge after 100 pulses (∼20–22 mm error), whereas all mTMS arrays reached median errors at or below 6 mm. mTMS also recovered deep targets better than sTMS (up to 35 mm skin–cortex distance, versus 25 mm) and performed uniformly across the region of interest. In addition, we found that a coil-space scheme based only on the magnetic vector potential, precomputable once per array without per-subject MRI, captured most of the benefit, matching subject-specific optimization at 100 pulses. mTMS thus makes voxel-wise mapping robust throughout a region of interest without coil repositioning.
- Open Access
- 15 October 2026
- Published by MIT Press in Imaging Neuroscience
Optimal Pre-Experimental Coil Sequence Selection for TMS Motor Mapping
Transcranial magnetic stimulation (TMS) motor mapping increasingly relies on electric-field (E-field) modeling to localize cortical targets, but many candidate coil placements induce highly redundant cortical patterns. We frame prospective coil-sequence design as a subset-selection problem and compare farthest-point sampling, determinant-based objectives, and related controls in virtual mapping experiments across 12 realistic head models. Across convergence, matrix-diagnostic, and manifold-coverage analyses, the best-performing objectives combined low between-stimulation redundancy with preserved inter-element separability on the cortex; objectives that maximized one of these at the expense of the other fell below random sampling. An RBF-kernelized D-optimal objective matched FPS in mapping accuracy while using ∼15 fewer unique scalp positions per 100 pulses, thereby reducing coil-movement time after offline route optimization. A singular-spectrum analysis of the candidate library provides a low-cost a-priori indicator that predicts when discretization choices fall below the diversity floor required for stable mapping. These results recast prospective TMS mapping as a limited manifold-coverage problem and offer concrete design rules for sample-efficient, robotically efficient sequence planning. Algorithm implementations are available as part of the open-source pynibs toolbox.
- 15 October 2026
- Published by MIT Press in Imaging Neuroscience
Open AccessOptimal Pre-Experimental Coil Sequence Selection for TMS Motor Mapping
Transcranial magnetic stimulation (TMS) motor mapping increasingly relies on electric-field (E-field) modeling to localize cortical targets, but many candidate coil placements induce highly redundant cortical patterns. We frame prospective coil-sequence design as a subset-selection problem and compare farthest-point sampling, determinant-based objectives, and related controls in virtual mapping experiments across 12 realistic head models. Across convergence, matrix-diagnostic, and manifold-coverage analyses, the best-performing objectives combined low between-stimulation redundancy with preserved inter-element separability on the cortex; objectives that maximized one of these at the expense of the other fell below random sampling. An RBF-kernelized D-optimal objective matched FPS in mapping accuracy while using ∼15 fewer unique scalp positions per 100 pulses, thereby reducing coil-movement time after offline route optimization. A singular-spectrum analysis of the candidate library provides a low-cost a-priori indicator that predicts when discretization choices fall below the diversity floor required for stable mapping. These results recast prospective TMS mapping as a limited manifold-coverage problem and offer concrete design rules for sample-efficient, robotically efficient sequence planning. Algorithm implementations are available as part of the open-source pynibs toolbox.
- Open Access
Real-time posterior probabilistic TMS motor mapping with robust individualized stopping criteria
Background: Electric-field-informed regression provides high-resolution transcranial magnetic stimulation (TMS) motor maps, but conventional nonlinear fitting is too slow to update the map during acquisition, so sessions rely on predefined stimulation budgets, despite substantial inter-individual variability in the data required for stable localization. Objective: To develop a real-time analysis updating a posterior probability map between pulses and compare its hotspots with finger-tapping functional MRI (fMRI). Methods: We analyzed two independent cohorts (12 and 13 participants, one newly collected); each hand muscle was analyzed independently. We replaced the conventional per-element sigmoid fit with Spearman's rank correlation coefficient and transformed the resulting score map into a posterior probability map using Bayesian evidence. Acquisition stopped once posterior mass within 5 mm of the hotspot passed a preset confidence level. Results: The Spearman and linear scores updated the region of interest within milliseconds, versus tens of seconds for sigmoid fitting. Spearman more closely matched the full-data sigmoid hotspot in recorded sessions and converged faster and more precisely to the true source in virtual subjects. Across both fast scores, at a confidence level of 0.85 the stopping criterion was met after a median of 74-159 pulses. FDI hotspots lay 8.3 ± 4.3 mm from the fMRI center of gravity, in the precentral hand region. Conclusions: Rank correlation reduces computation time without loss of accuracy relative to sigmoid fitting. The resulting posterior probability map provides a session-specific stopping criterion in place of a fixed pulse budget.
Open AccessReal-time posterior probabilistic TMS motor mapping with robust individualized stopping criteria
Background: Electric-field-informed regression provides high-resolution transcranial magnetic stimulation (TMS) motor maps, but conventional nonlinear fitting is too slow to update the map during acquisition, so sessions rely on predefined stimulation budgets, despite substantial inter-individual variability in the data required for stable localization. Objective: To develop a real-time analysis updating a posterior probability map between pulses and compare its hotspots with finger-tapping functional MRI (fMRI). Methods: We analyzed two independent cohorts (12 and 13 participants, one newly collected); each hand muscle was analyzed independently. We replaced the conventional per-element sigmoid fit with Spearman's rank correlation coefficient and transformed the resulting score map into a posterior probability map using Bayesian evidence. Acquisition stopped once posterior mass within 5 mm of the hotspot passed a preset confidence level. Results: The Spearman and linear scores updated the region of interest within milliseconds, versus tens of seconds for sigmoid fitting. Spearman more closely matched the full-data sigmoid hotspot in recorded sessions and converged faster and more precisely to the true source in virtual subjects. Across both fast scores, at a confidence level of 0.85 the stopping criterion was met after a median of 74-159 pulses. FDI hotspots lay 8.3 ± 4.3 mm from the fMRI center of gravity, in the precentral hand region. Conclusions: Rank correlation reduces computation time without loss of accuracy relative to sigmoid fitting. The resulting posterior probability map provides a session-specific stopping criterion in place of a fixed pulse budget.
- Open Access
Adaptive Bayesian localization of motor representation areas
Transcranial magnetic stimulation (TMS) enables non-invasive localization of cortical motor representations, with important clinical applications in presurgical planning. Existing methods either disregard spatial information about the TMS-induced electric field (E-field) or use acquisition schemes that do not leverage previously elicited motor responses to guide subsequent stimulation. We present an adaptive Bayesian localization method that combines real-time E-field optimization with per-trial probabilistic inference. The cortical origin of the motor responses is represented as a spatial probability distribution that is updated after each stimulus. Subsequent stimuli are then optimized to maximize the expected localization improvement given previous responses. We validated the method experimentally, using multi-locus TMS for adaptive localization and single-coil TMS as a non-adaptive reference with randomized coil placements. Across eight subjects, the adaptive protocol at least halved the number of stimuli required for stable localization compared to the randomized protocol, converging in 60 stimuli on average, with 95% highest-density regions often below 10 mm 2 by 150 stimuli.
Open AccessAdaptive Bayesian localization of motor representation areas
Transcranial magnetic stimulation (TMS) enables non-invasive localization of cortical motor representations, with important clinical applications in presurgical planning. Existing methods either disregard spatial information about the TMS-induced electric field (E-field) or use acquisition schemes that do not leverage previously elicited motor responses to guide subsequent stimulation. We present an adaptive Bayesian localization method that combines real-time E-field optimization with per-trial probabilistic inference. The cortical origin of the motor responses is represented as a spatial probability distribution that is updated after each stimulus. Subsequent stimuli are then optimized to maximize the expected localization improvement given previous responses. We validated the method experimentally, using multi-locus TMS for adaptive localization and single-coil TMS as a non-adaptive reference with randomized coil placements. Across eight subjects, the adaptive protocol at least halved the number of stimuli required for stable localization compared to the randomized protocol, converging in 60 stimuli on average, with 95% highest-density regions often below 10 mm 2 by 150 stimuli.
- Open Access
Optimal Pre-Experimental Coil Sequence Selection for TMS Motor Mapping
Transcranial magnetic stimulation (TMS) motor mapping increasingly relies on electric-field (E-field) modeling to localize cortical targets, but many candidate coil placements induce highly redundant cortical patterns. We frame prospective coil-sequence design as a subset-selection problem and compare farthest-point sampling, determinant-based objectives, and related controls in virtual mapping experiments across 12 realistic head models. Across convergence, matrix-diagnostic, and manifold-coverage analyses, the best-performing objectives combined low between-stimulation redundancy with preserved inter-element separability on the cortex; objectives that maximized one of these at the expense of the other fell below random sampling. An RBF-kernelized D-optimal objective matched FPS in mapping accuracy while using ∼15 fewer unique scalp positions per 100 pulses, suggesting reduced arm-reconfiguration cost on robotic TMS platforms. A singular-spectrum analysis of the candidate library provides a low-cost a-priori indicator that predicts when discretization choices fall below the diversity floor required for stable mapping. These results recast prospective TMS mapping as a limited manifold-coverage problem and offer concrete design rules for sample-efficient, robotically efficient sequence planning. Algorithm implementations are available as part of the open-source pynibs tool-box at https://gitlab.gwdg.de/tms-localization/pynibs/-/tree/dev/pynibs/optimization .
Open AccessOptimal Pre-Experimental Coil Sequence Selection for TMS Motor Mapping
Transcranial magnetic stimulation (TMS) motor mapping increasingly relies on electric-field (E-field) modeling to localize cortical targets, but many candidate coil placements induce highly redundant cortical patterns. We frame prospective coil-sequence design as a subset-selection problem and compare farthest-point sampling, determinant-based objectives, and related controls in virtual mapping experiments across 12 realistic head models. Across convergence, matrix-diagnostic, and manifold-coverage analyses, the best-performing objectives combined low between-stimulation redundancy with preserved inter-element separability on the cortex; objectives that maximized one of these at the expense of the other fell below random sampling. An RBF-kernelized D-optimal objective matched FPS in mapping accuracy while using ∼15 fewer unique scalp positions per 100 pulses, suggesting reduced arm-reconfiguration cost on robotic TMS platforms. A singular-spectrum analysis of the candidate library provides a low-cost a-priori indicator that predicts when discretization choices fall below the diversity floor required for stable mapping. These results recast prospective TMS mapping as a limited manifold-coverage problem and offer concrete design rules for sample-efficient, robotically efficient sequence planning. Algorithm implementations are available as part of the open-source pynibs tool-box at https://gitlab.gwdg.de/tms-localization/pynibs/-/tree/dev/pynibs/optimization .
- Open Access
Cortical Stimulation Strength and sgACC Connectivity Shape Neuro-Cardiac Responses to Prefrontal TMS
Autonomic dysregulation is associated with major depressive disorder, yet how cortical stimulation strength and network connectivity shape autonomic responses to prefrontal transcranial magnetic stimulation (TMS) remains unclear. We combined resting-state functional MRI, individualized electric-field simulations, and electrocardiography during repetitive TMS at up to six left dorsolateral prefrontal cortex (DLPFC) targets in 15 healthy adults. Heart-brain coupling (HBC), quantified as cardiac spectral power at the stimulation-cycle frequency, was modeled using either motor-threshold-based intensity or cortical electric-field strength, with and without DLPFC connectivity to the subgenual anterior cingulate cortex (sgACC). In linear mixed-effects models, electric-field strength provided better fit and explained more HBC variance than motor-threshold-based intensity. Adding sgACC connectivity further improved model fit and revealed site-specific electric-field-by-connectivity interactions. High-resolution mapping revealed spatial correspondence between regions of higher E-field-HBC explained variance and sgACC-anticorrelated cortex. Negative sgACC connectivity was associated with steeper predicted increases in HBC at several sites, while nonlinear models showed site-dependent differences in dose-response profiles between negative and positive connectivity. Together, these findings link acute cardiac responses to cortical electric-field exposure and sgACC connectivity, supporting HBC as a network-sensitive physiological readout for investigating frontal-vagal function. This framework provides a basis for testing individualized prefrontal TMS targeting and dosing in depression-related autonomic dysregulation.
Open AccessCortical Stimulation Strength and sgACC Connectivity Shape Neuro-Cardiac Responses to Prefrontal TMS
Autonomic dysregulation is associated with major depressive disorder, yet how cortical stimulation strength and network connectivity shape autonomic responses to prefrontal transcranial magnetic stimulation (TMS) remains unclear. We combined resting-state functional MRI, individualized electric-field simulations, and electrocardiography during repetitive TMS at up to six left dorsolateral prefrontal cortex (DLPFC) targets in 15 healthy adults. Heart-brain coupling (HBC), quantified as cardiac spectral power at the stimulation-cycle frequency, was modeled using either motor-threshold-based intensity or cortical electric-field strength, with and without DLPFC connectivity to the subgenual anterior cingulate cortex (sgACC). In linear mixed-effects models, electric-field strength provided better fit and explained more HBC variance than motor-threshold-based intensity. Adding sgACC connectivity further improved model fit and revealed site-specific electric-field-by-connectivity interactions. High-resolution mapping revealed spatial correspondence between regions of higher E-field-HBC explained variance and sgACC-anticorrelated cortex. Negative sgACC connectivity was associated with steeper predicted increases in HBC at several sites, while nonlinear models showed site-dependent differences in dose-response profiles between negative and positive connectivity. Together, these findings link acute cardiac responses to cortical electric-field exposure and sgACC connectivity, supporting HBC as a network-sensitive physiological readout for investigating frontal-vagal function. This framework provides a basis for testing individualized prefrontal TMS targeting and dosing in depression-related autonomic dysregulation.
- Open Access
- 12 February 2026
- Published by Elsevier in Brain Stimulation
- Vol. 19 (2) , 103054
Optimizing and assessing multichannel TMS focality
- 12 February 2026
- Published by Elsevier in Brain Stimulation
- Vol. 19 (2) , 103054
Open AccessOptimizing and assessing multichannel TMS focality
- Top Cited PapersOpen Access
- 7 February 2026
- Published by Springer Nature in Translational Psychiatry
- Vol. 16 (1)
Target-Specificity and repeatability in neuro-cardiac-guided TMS for heart-brain coupling
The dorsolateral prefrontal cortex (DLPFC) is a principal target for transcranial magnetic stimulation (TMS) in treating major depressive disorder, with therapeutic effects thought to be mediated by its connectivity with the subgenual anterior cingulate cortex. As both regions are involved in autonomic regulation, short-term heart rate changes following DLPFC stimulation may serve as physiological markers to identify stimulation targets. We employed neuro-cardiac guided TMS in a cohort of healthy participants to examine the effects of stimulation intensity and DLPFC target specificity on heart–brain coupling (HBC). We used generalized additive models to assess nonlinear effects of stimulation intensity and target location on HBC, while accounting for pain ratings and other side effects. Intra-subject repeatability across three sessions was evaluated using intraclass correlation coefficients. We observed a non-linear modulation of HBC depending on stimulation intensity and target location, with greater effects at the F3 lateral and F3 posterior targets compared to sham. By evaluating these effects across sessions within participants, we demonstrate the robustness of our results beyond the influence of pain and other side effects on HBC modulation. Exploratory analyses of the directionality show a consistent decrease in HR only at the F3 lateral target with suprathreshold stimulation. These results demonstrate that HBC is modulated in a target- and intensity-specific manner, with particularly consistent effects at F3 lateral sites within the DLPFC. The findings enhance the understanding of TMS-modulated heart-brain interactions, offering a potential framework for optimizing individualized rTMS treatment protocols for depression.
- 7 February 2026
- Published by Springer Nature in Translational Psychiatry
- Vol. 16 (1)
Top Cited PapersOpen AccessTarget-Specificity and repeatability in neuro-cardiac-guided TMS for heart-brain coupling
The dorsolateral prefrontal cortex (DLPFC) is a principal target for transcranial magnetic stimulation (TMS) in treating major depressive disorder, with therapeutic effects thought to be mediated by its connectivity with the subgenual anterior cingulate cortex. As both regions are involved in autonomic regulation, short-term heart rate changes following DLPFC stimulation may serve as physiological markers to identify stimulation targets. We employed neuro-cardiac guided TMS in a cohort of healthy participants to examine the effects of stimulation intensity and DLPFC target specificity on heart–brain coupling (HBC). We used generalized additive models to assess nonlinear effects of stimulation intensity and target location on HBC, while accounting for pain ratings and other side effects. Intra-subject repeatability across three sessions was evaluated using intraclass correlation coefficients. We observed a non-linear modulation of HBC depending on stimulation intensity and target location, with greater effects at the F3 lateral and F3 posterior targets compared to sham. By evaluating these effects across sessions within participants, we demonstrate the robustness of our results beyond the influence of pain and other side effects on HBC modulation. Exploratory analyses of the directionality show a consistent decrease in HR only at the F3 lateral target with suprathreshold stimulation. These results demonstrate that HBC is modulated in a target- and intensity-specific manner, with particularly consistent effects at F3 lateral sites within the DLPFC. The findings enhance the understanding of TMS-modulated heart-brain interactions, offering a potential framework for optimizing individualized rTMS treatment protocols for depression.
- Open Access
Optimizing and assessing multichannel TMS focality
Background: Multichannel transcranial magnetic stimulation (mTMS) enables electronic steering of induced electric fields across multiple cortical targets without physical coil repositioning, addressing key limitations of conventional single-channel TMS (sTMS). However, determining optimal input currents for focal stimulation remains challenging, and different mTMS systems have not been systematically compared under realistic hardware constraints. Objective: To develop an user-centric framework for optimizing and assessing mTMS focality by introducing a generic optimization algorithm, establishing meaningful quality metrics, and comparing mTMS coil arrays with traditional single-channel TMS across cortical targets. Methods: We developed a fast optimization framework incorporating target E-field constraints via parametrization of degenerated hyperellipsoids, explicitly integrating current-rate limits, for example from stimulator electronics and coil heating. Using high-resolution finite-element models of nine individual brains, we compared two mTMS designs (5-channel planar and 6/12-channel spherical systems) with standard sTMS figure-of-eight coils through E-field simulations. Three complementary metrics quantified stimulation quality: Focality, Target2Max, and OverstimulatedArea. Results: Despite using a single optimized placement for all region-of-interest targets, mTMS achieved focality comparable to repositioned single-channel TMS in this in-silico study. For superficial targets, single-channel TMS showed slightly better stimulation, but for deeper cortical targets (>25 mm skin-cortex distance), mTMS performed similarly. More mTMS channels improved focality but required stronger current-rate constraints. The planar design performed better for deeper targets, while spherical designs improved with additional channels. Conclusion: mTMS systems demonstrate remarkable performance comparable to standard TMS, enabling efficient multi-target stimulation without repositioning. Our open-source framework provides practical tools for designing and evaluating mTMS systems, supporting goal-directed mTMS development and effective application.
Open AccessOptimizing and assessing multichannel TMS focality
Background: Multichannel transcranial magnetic stimulation (mTMS) enables electronic steering of induced electric fields across multiple cortical targets without physical coil repositioning, addressing key limitations of conventional single-channel TMS (sTMS). However, determining optimal input currents for focal stimulation remains challenging, and different mTMS systems have not been systematically compared under realistic hardware constraints. Objective: To develop an user-centric framework for optimizing and assessing mTMS focality by introducing a generic optimization algorithm, establishing meaningful quality metrics, and comparing mTMS coil arrays with traditional single-channel TMS across cortical targets. Methods: We developed a fast optimization framework incorporating target E-field constraints via parametrization of degenerated hyperellipsoids, explicitly integrating current-rate limits, for example from stimulator electronics and coil heating. Using high-resolution finite-element models of nine individual brains, we compared two mTMS designs (5-channel planar and 6/12-channel spherical systems) with standard sTMS figure-of-eight coils through E-field simulations. Three complementary metrics quantified stimulation quality: Focality, Target2Max, and OverstimulatedArea. Results: Despite using a single optimized placement for all region-of-interest targets, mTMS achieved focality comparable to repositioned single-channel TMS in this in-silico study. For superficial targets, single-channel TMS showed slightly better stimulation, but for deeper cortical targets (>25 mm skin-cortex distance), mTMS performed similarly. More mTMS channels improved focality but required stronger current-rate constraints. The planar design performed better for deeper targets, while spherical designs improved with additional channels. Conclusion: mTMS systems demonstrate remarkable performance comparable to standard TMS, enabling efficient multi-target stimulation without repositioning. Our open-source framework provides practical tools for designing and evaluating mTMS systems, supporting goal-directed mTMS development and effective application.