Ezgi Sonkaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ezgi Sonkaya has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Zehra Süsgün Yildirim
ÇUKUROVA ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ
4 shared publications - Zeliha Gonca Bek Kürklü
ÇUKUROVA ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTES
4 shared publications - Eda Çakmak
Department of Audiology, Başkent University Faculty of Health Sciences, Ankara, Türkiye
3 shared publications - Güler Burcu Senirkentli
Başkent Üniversitesi
3 shared publications - Yeşim TURAN
Başkent Üniversitesi
3 shared publications - Hazal Duyan Yüksel
ÇUKUROVA ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ
2 shared publications
Latest Publications
- Open Access
- 7 October 2026
- Published by Springer Nature in BMC Oral Health
Differentiation of cervical caries and cervical burnout on orthopantomographic images: a radiomics-based machine learning approach
- 7 October 2026
- Published by Springer Nature in BMC Oral Health
Open AccessDifferentiation of cervical caries and cervical burnout on orthopantomographic images: a radiomics-based machine learning approach
- 20 May 2026
- Published by Ankara Dis Hekimleri Odasi in ADO Klinik Bilimler Dergisi
- Vol. 15 (2) , 105-113
Effects of Build Orientation and Post-polymerization Method on the Mechanical Properties of a 3D-printed Permanent Resin Material
Aim. The purpose of this study was to investigate how different build orientations and post-polymerization protocols influence the microhardness and biaxial flexural strength (BFS) of 3D-printed permanent resin material.Materials and Methods. Ninety disc-shaped specimens were manufactured using a digital light processing (DLP) 3D printer at three build orientations (0°, 45°, 90°). Specimens were post-processed using either a desktop curing unit (FC) or a handheld polywave light emitting diode (LED) light-curing unit (LCU). Microhardness (VHN) was measured using a Vickers microhardness tester, and BFS was evaluated using a piston-on-three-ball test. Two-way ANOVA and Tukey HSD tests were used for statistical analysis (α = .05).Results. The post-polymerization method significantly affected BFS (p < .001), with the LCU group exhibiting higher strength (336.8 ± 81.6 MPa) than the FC group (255.2 ± 83.3 MPa). Build orientation also had a significant influence on BFS (p < .001); the 0° groups showed higher values than the 45° and 90° groups. Microhardness was significantly influenced by the post-polymerization method (p = .04), whereas build orientation had no significant effect on VHN values (p = .63).Conclusion. Both build orientation and post-polymerization method influenced the mechanical behavior of the 3D-printed resin, particularly its BFS. The handheld polywave LCU provided superior flexural performance compared with the desktop curing unit, suggesting that it may serve as a reliable alternative for post-polymerization of 3D-printed dental materials. Optimizing printing and post-polymerization parameters is essential to enhance the mechanical reliability of additively manufactured restorations.
- 20 May 2026
- Published by Ankara Dis Hekimleri Odasi in ADO Klinik Bilimler Dergisi
- Vol. 15 (2) , 105-113
Effects of Build Orientation and Post-polymerization Method on the Mechanical Properties of a 3D-printed Permanent Resin Material
Aim. The purpose of this study was to investigate how different build orientations and post-polymerization protocols influence the microhardness and biaxial flexural strength (BFS) of 3D-printed permanent resin material.Materials and Methods. Ninety disc-shaped specimens were manufactured using a digital light processing (DLP) 3D printer at three build orientations (0°, 45°, 90°). Specimens were post-processed using either a desktop curing unit (FC) or a handheld polywave light emitting diode (LED) light-curing unit (LCU). Microhardness (VHN) was measured using a Vickers microhardness tester, and BFS was evaluated using a piston-on-three-ball test. Two-way ANOVA and Tukey HSD tests were used for statistical analysis (α = .05).Results. The post-polymerization method significantly affected BFS (p < .001), with the LCU group exhibiting higher strength (336.8 ± 81.6 MPa) than the FC group (255.2 ± 83.3 MPa). Build orientation also had a significant influence on BFS (p < .001); the 0° groups showed higher values than the 45° and 90° groups. Microhardness was significantly influenced by the post-polymerization method (p = .04), whereas build orientation had no significant effect on VHN values (p = .63).Conclusion. Both build orientation and post-polymerization method influenced the mechanical behavior of the 3D-printed resin, particularly its BFS. The handheld polywave LCU provided superior flexural performance compared with the desktop curing unit, suggesting that it may serve as a reliable alternative for post-polymerization of 3D-printed dental materials. Optimizing printing and post-polymerization parameters is essential to enhance the mechanical reliability of additively manufactured restorations.
- 30 April 2026
- Published by Diş Hekimliği Fakültesi, Harran Üniversitesi in HRU International Journal of Dentistry and Oral Research
- Vol. 6 (1) , 20-31
Effect of Minimal and Non-Preparation Techniques and Universal Adhesive Systems on the Fracture Resistance of Direct Composite Veneers
Background: Fracture resistance at the interface between the tooth substrate and adhesive systems is a key determinant of the clinical durability of direct composite veneer restorations. Evaluating the influence of different preparation strategies and universal adhesive systems on fracture resistance is essential for improving the predictability of clinical outcomes.Materials and Methods: Forty extracted maxillary incisors were randomly allocated into two groups according to the preparation technique: no preparation and minimal preparation. Each group was further subdivided based on the adhesive system used: Single Bond Universal or Prime & Bond Universal. Direct composite laminate veneers were fabricated for all specimens, which were subsequently embedded in acrylic resin blocks. Fracture resistance was measured. Failure patterns were classified as adhesive, cohesive, or mixed. Data were analyzed using one-way ANOVA followed by Tukey’s HSD post hoc test (α=0.05).Results: The lowest bond strength values were observed in the Single Bond Universal no-preparation (SBN) group, whereas the highest values were recorded in the Prime & Bond Universal minimal-preparation (PBM) group. There was no significant statistical difference identified among the groups (p>0.05).Conclusions: Both universal adhesive systems demonstrated clinically acceptable fracture resistance regardless of the preparation technique. Proper treatment planning may contribute to long-term functional and aesthetic success in direct composite veneer restorations.
- 30 April 2026
- Published by Diş Hekimliği Fakültesi, Harran Üniversitesi in HRU International Journal of Dentistry and Oral Research
- Vol. 6 (1) , 20-31
Effect of Minimal and Non-Preparation Techniques and Universal Adhesive Systems on the Fracture Resistance of Direct Composite Veneers
Background: Fracture resistance at the interface between the tooth substrate and adhesive systems is a key determinant of the clinical durability of direct composite veneer restorations. Evaluating the influence of different preparation strategies and universal adhesive systems on fracture resistance is essential for improving the predictability of clinical outcomes.Materials and Methods: Forty extracted maxillary incisors were randomly allocated into two groups according to the preparation technique: no preparation and minimal preparation. Each group was further subdivided based on the adhesive system used: Single Bond Universal or Prime & Bond Universal. Direct composite laminate veneers were fabricated for all specimens, which were subsequently embedded in acrylic resin blocks. Fracture resistance was measured. Failure patterns were classified as adhesive, cohesive, or mixed. Data were analyzed using one-way ANOVA followed by Tukey’s HSD post hoc test (α=0.05).Results: The lowest bond strength values were observed in the Single Bond Universal no-preparation (SBN) group, whereas the highest values were recorded in the Prime & Bond Universal minimal-preparation (PBM) group. There was no significant statistical difference identified among the groups (p>0.05).Conclusions: Both universal adhesive systems demonstrated clinically acceptable fracture resistance regardless of the preparation technique. Proper treatment planning may contribute to long-term functional and aesthetic success in direct composite veneer restorations.
- 6 January 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (2) , 586-594
Does Cigarette Smoke Affect Permanent Resin‐Based Crown Materials?
Objective: The purpose of this study was to investigate how cigarette smoking affects the surface roughness (Ra) and stainability of additively and subtractively manufactured resins.Materials and Methods: Two additively manufactured definitive resins (Dentafab, DF and Formlabs, FL) and a subtractively manufactured resin nanoceramic (Cerasmart, CS) were used to fabricate 60 specimens (14 × 12 × 1 mm). After taking baseline Ra and color measurements (ΔE00), they were divided into two groups (n = 10). Using a programmable cigarette smoking simulation device, the study groups smoked 10 cigarettes a day for 30 days. The control groups were kept in artificial saliva for 30 days. The Ra and ΔE00 were performed again. Scanning electron microscope images were taken. Kruskal–Wallis test, Mann–Whitney U, Bonferroni, and Wilcoxon Signed Rank tests were used for statistical analyses (α = 0.05).Result: Significantly less discoloration was observed in the FL group compared with the other groups (p < 0.001). The Ra of the DF study groups was statistically significantly higher than the control groups (p = 0.005).Conclusion: All the tested materials had moderately unacceptable color change when previously reported threshold values were considered. There was not found to be any linear correlation between the Ra of materials and smoking‐induced discoloration.Clinical Significance: The discoloration and surface roughness of three‐dimensional (3D)‐produced SLA definitive resin because of smoking are at acceptable levels. Optimized physical and chemical properties of definitive resins are clinically important to extend the life of the restoration. The application of 3D definitive resin can be recommended in clinical practice.
- 6 January 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (2) , 586-594
Does Cigarette Smoke Affect Permanent Resin‐Based Crown Materials?
Objective: The purpose of this study was to investigate how cigarette smoking affects the surface roughness (Ra) and stainability of additively and subtractively manufactured resins.Materials and Methods: Two additively manufactured definitive resins (Dentafab, DF and Formlabs, FL) and a subtractively manufactured resin nanoceramic (Cerasmart, CS) were used to fabricate 60 specimens (14 × 12 × 1 mm). After taking baseline Ra and color measurements (ΔE00), they were divided into two groups (n = 10). Using a programmable cigarette smoking simulation device, the study groups smoked 10 cigarettes a day for 30 days. The control groups were kept in artificial saliva for 30 days. The Ra and ΔE00 were performed again. Scanning electron microscope images were taken. Kruskal–Wallis test, Mann–Whitney U, Bonferroni, and Wilcoxon Signed Rank tests were used for statistical analyses (α = 0.05).Result: Significantly less discoloration was observed in the FL group compared with the other groups (p < 0.001). The Ra of the DF study groups was statistically significantly higher than the control groups (p = 0.005).Conclusion: All the tested materials had moderately unacceptable color change when previously reported threshold values were considered. There was not found to be any linear correlation between the Ra of materials and smoking‐induced discoloration.Clinical Significance: The discoloration and surface roughness of three‐dimensional (3D)‐produced SLA definitive resin because of smoking are at acceptable levels. Optimized physical and chemical properties of definitive resins are clinically important to extend the life of the restoration. The application of 3D definitive resin can be recommended in clinical practice.
- Open Access
- 26 April 2024
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 11 (1) , 17-22
Farklı Mikrohibrit Kompozitlerin Renk Stabilitesi ve Translüsensi Parametresi Açısından Karşılaştırılması: in Vitro Çalışma
Amaç: Bu in vitro çalışmada farklı mikrohibrid kompozitlerin distile su veya kahvede bekletildikten sonra renk stabilitelerinin ve translüsensi parametrelerinin (TP) karşılaştırılması amaçlanmıştır. Gereç ve Yöntem: Üç farklı mikrohibrit kompozit rezin materyalden [G-eanial Anterior (GC, Japonya), Filtek Z250 (3M, ABD), yeni geliştirilen Üniversal Kompozit (Dolgunn-Himg, Türkiye)] her gruptan 20 adet ve toplamda 60 adet disk olacak şekilde örnekler oluşturuldu. Örneklerin yarısı distile suda diğer yarısı hazır kahve içeren kaplarda bekletildi. Renk stabilitesini değerlendirmek için başlangıç, 1. ve 4. hafta sonunda; TP için ise başlangıç ve 4. hafta sonunda bir spektrofotometre ile ölçümler yapıldı. Ortalama L*,a*, b* renk değişim değerleri CIEDE2000 renk formülüne (ΔE00) uygulandı. Renk parametresi için; renk değişim değerleri (ΔE) ve TP için; translüsensi değişim değerleri (ΔTP) hesaplandı. Verilerin analizinde tekrarlı ölçümlerde iki yönlü varyans analizi kullanılmıştır. Küresellik varsayımı Mauchly’nin W testi ile değerlendirilmiştir. Çoklu karşılaştırmalarda LSD testi kullanılmıştır (p<0.05). Bulgular: Kompozit rezin örneklerde 1 ve 4 hafta kahvede bekletme sonrası anlamlı düzeyde renk değişimi (ΔE: 3.45-7.93) gözlendi. En yüksek renk değişimi Dolgunn kompozit grubunda (p<0.001; p=0,001) saptandı. Kahve ve kontrol grubunda yer alan kompozitlerin TP değerlerinde farklılık gözlenmedi (F=1,821 p=0,181; F=0,191 p=0,828). Sonuç: Çalışmada, restoratif materyallerin renk stabilitesinde içerik ve kompozisyonu gibi yapısal özelliklerinin renklenmeye neden olan içeriklere maruz kalmaları durumunda önemli bir bileşen olduğu, ancak optik özellikleri belirleyen translüsensi parametresinde anlamlı değişikliğine neden olmadığı gözlenmiştir.
- 26 April 2024
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 11 (1) , 17-22
Open AccessFarklı Mikrohibrit Kompozitlerin Renk Stabilitesi ve Translüsensi Parametresi Açısından Karşılaştırılması: in Vitro Çalışma
Amaç: Bu in vitro çalışmada farklı mikrohibrid kompozitlerin distile su veya kahvede bekletildikten sonra renk stabilitelerinin ve translüsensi parametrelerinin (TP) karşılaştırılması amaçlanmıştır. Gereç ve Yöntem: Üç farklı mikrohibrit kompozit rezin materyalden [G-eanial Anterior (GC, Japonya), Filtek Z250 (3M, ABD), yeni geliştirilen Üniversal Kompozit (Dolgunn-Himg, Türkiye)] her gruptan 20 adet ve toplamda 60 adet disk olacak şekilde örnekler oluşturuldu. Örneklerin yarısı distile suda diğer yarısı hazır kahve içeren kaplarda bekletildi. Renk stabilitesini değerlendirmek için başlangıç, 1. ve 4. hafta sonunda; TP için ise başlangıç ve 4. hafta sonunda bir spektrofotometre ile ölçümler yapıldı. Ortalama L*,a*, b* renk değişim değerleri CIEDE2000 renk formülüne (ΔE00) uygulandı. Renk parametresi için; renk değişim değerleri (ΔE) ve TP için; translüsensi değişim değerleri (ΔTP) hesaplandı. Verilerin analizinde tekrarlı ölçümlerde iki yönlü varyans analizi kullanılmıştır. Küresellik varsayımı Mauchly’nin W testi ile değerlendirilmiştir. Çoklu karşılaştırmalarda LSD testi kullanılmıştır (p<0.05). Bulgular: Kompozit rezin örneklerde 1 ve 4 hafta kahvede bekletme sonrası anlamlı düzeyde renk değişimi (ΔE: 3.45-7.93) gözlendi. En yüksek renk değişimi Dolgunn kompozit grubunda (p<0.001; p=0,001) saptandı. Kahve ve kontrol grubunda yer alan kompozitlerin TP değerlerinde farklılık gözlenmedi (F=1,821 p=0,181; F=0,191 p=0,828). Sonuç: Çalışmada, restoratif materyallerin renk stabilitesinde içerik ve kompozisyonu gibi yapısal özelliklerinin renklenmeye neden olan içeriklere maruz kalmaları durumunda önemli bir bileşen olduğu, ancak optik özellikleri belirleyen translüsensi parametresinde anlamlı değişikliğine neden olmadığı gözlenmiştir.
- 5 November 2023
- Published by Wiley in European Journal of Dental Education
- Vol. 28 (2) , 452-460
Comparisons of student comprehension of 3D‐printed, standard model, and extracted teeth in hands‐on sessions
Introduction: Cavity preparation and direct and indirect pulp capping are difficult processes to learn in dentistry. Although plastic teeth are used in universities in Turkey, the standard model does not teach students how to distinguish between dental hard tissues from caries and how this relates to the pulp. The aim of this study was to investigate the differences in learning when a three‐dimensional (3D)‐printed tooth was employed in comparison with the standard model and extracted teeth. The differences are evaluated in the design, feasibility, and contribution of the 3D‐printed dental tooth in pre‐clinical education.Materials and Methods: The multi‐layer 3D‐printed tooth's authentic design and replication of the dental hard tissues and carious lesions are explored with 55 students for pre‐clinical education, which includes caries excavation and direct and indirect pulp capping. The students completed questionnaires evaluating the 3D‐printed teeth through comparison with the plastic and extracted teeth, rated with scores from 1 to 11 (1: poorest conformity; 11: excellent conformity).Results: The questionnaire results indicated that students approved the printed tooth model for the practice of theoretical knowledge and the model received ratings between good and excellent. The results were statistically analysed using the Wilcoxon signed‐rank test, and the printed teeth had the highest approval from the students (p < .001).Conclusion: The results of this study demonstrated that the use of the designed 3D‐printed tooth is preferred by the students based on their perception of learning cavity preparation and pulp capping in a pre‐clinical environment. Workflow and production were cost‐effective with the use of 3D printing technology. The printed tooth allowed students to gain realistic experience before treating patients.
- 5 November 2023
- Published by Wiley in European Journal of Dental Education
- Vol. 28 (2) , 452-460
Comparisons of student comprehension of 3D‐printed, standard model, and extracted teeth in hands‐on sessions
Introduction: Cavity preparation and direct and indirect pulp capping are difficult processes to learn in dentistry. Although plastic teeth are used in universities in Turkey, the standard model does not teach students how to distinguish between dental hard tissues from caries and how this relates to the pulp. The aim of this study was to investigate the differences in learning when a three‐dimensional (3D)‐printed tooth was employed in comparison with the standard model and extracted teeth. The differences are evaluated in the design, feasibility, and contribution of the 3D‐printed dental tooth in pre‐clinical education.Materials and Methods: The multi‐layer 3D‐printed tooth's authentic design and replication of the dental hard tissues and carious lesions are explored with 55 students for pre‐clinical education, which includes caries excavation and direct and indirect pulp capping. The students completed questionnaires evaluating the 3D‐printed teeth through comparison with the plastic and extracted teeth, rated with scores from 1 to 11 (1: poorest conformity; 11: excellent conformity).Results: The questionnaire results indicated that students approved the printed tooth model for the practice of theoretical knowledge and the model received ratings between good and excellent. The results were statistically analysed using the Wilcoxon signed‐rank test, and the printed teeth had the highest approval from the students (p < .001).Conclusion: The results of this study demonstrated that the use of the designed 3D‐printed tooth is preferred by the students based on their perception of learning cavity preparation and pulp capping in a pre‐clinical environment. Workflow and production were cost‐effective with the use of 3D printing technology. The printed tooth allowed students to gain realistic experience before treating patients.
- Open Access
- 21 August 2023
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 10 (2) , 434-439
Çukurova Popülasyonunda Gelişimsel Diş Anomalisi Görülme Sıklığı: Radyografik Bir Çalışma
Amaç: Bu çalışmanın amacı, retrospektif olarak incelenen panoramik radyografilerde görülen dental anomalilerin tüm tip ve alt tiplerinin prevalansını değerlendirmekti. Gereç ve Yöntemler: 2019 yılının son 6 ayında, bir fakülte hastanesine başvuran ve panoramik röntgeni çekilen 14 – 70 yaş aralığındaki 1266 hastanın radyografisi incelendi. Durum, büyüklük, sayı, biçim ve doku olarak 5 tip, toplamda 21 alt tip (Transpozisyon, Ektopi, Enversiyon, Median diastema, Mikrodonti, Makrodonti, Hipodonti, Oligodonti, Anadonti, Supernumerer, Meziodens, Talon tüberkülü (dens evaginatus), Taurodontizm, Dilaserasyon, Geminasyon, Füzyon, Concrescence, Dens in dente (dens invaginatus), Amelogenezis imperfekta, Dentinogenezis imperfekta, Dentin displazisi) gelişimsel diş anomalisi araştırıldı. Yaş ortalamaları için bağımsız örneklem t-testi, anomalilerin dağılımlarını değerlendirmek için ki-kare ve Fisher’s Exact testi kullanıldı. Bulgular: Yaş ortalaması 36.9 olan hastaların % 27.8’inde dental anomali görüldü. Kadınlarda anomali görülme prevalansı (% 30.3) erkeklere göre (% 23.8) anlamlı olarak daha yüksekti. Anomaliye sahip kadınlarda ise biçim anomalisi (% 68.6) ve alt tipi olarak talon tüberkülü (% 40.3) prevalansı anlamlı olarak yüksekti. Diğer anomali alt tipleri ve cinsiyetler arasında istatistiksel olarak anlamlı bir fark yoktu. En sık, sırasıyla talon tüberkülü (% 36.1), dilaserasyon (% 15.3), median diastema (% 12.8), tek diş eksikliği (% 11.9) ve dens in dente (% 11.6) alt tiplerine rastlanıldı. Sonuç: Her dört hastadan birinde dental anomaliye rastlama ihtimali olduğunu gösteren çalışmanın sonucu, başvuran her hastadan panoramik radyografi alınmasının ve detaylı bir incelemenin önemini bir kez daha ortaya koymuştur.
- 21 August 2023
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 10 (2) , 434-439
Open AccessÇukurova Popülasyonunda Gelişimsel Diş Anomalisi Görülme Sıklığı: Radyografik Bir Çalışma
Amaç: Bu çalışmanın amacı, retrospektif olarak incelenen panoramik radyografilerde görülen dental anomalilerin tüm tip ve alt tiplerinin prevalansını değerlendirmekti. Gereç ve Yöntemler: 2019 yılının son 6 ayında, bir fakülte hastanesine başvuran ve panoramik röntgeni çekilen 14 – 70 yaş aralığındaki 1266 hastanın radyografisi incelendi. Durum, büyüklük, sayı, biçim ve doku olarak 5 tip, toplamda 21 alt tip (Transpozisyon, Ektopi, Enversiyon, Median diastema, Mikrodonti, Makrodonti, Hipodonti, Oligodonti, Anadonti, Supernumerer, Meziodens, Talon tüberkülü (dens evaginatus), Taurodontizm, Dilaserasyon, Geminasyon, Füzyon, Concrescence, Dens in dente (dens invaginatus), Amelogenezis imperfekta, Dentinogenezis imperfekta, Dentin displazisi) gelişimsel diş anomalisi araştırıldı. Yaş ortalamaları için bağımsız örneklem t-testi, anomalilerin dağılımlarını değerlendirmek için ki-kare ve Fisher’s Exact testi kullanıldı. Bulgular: Yaş ortalaması 36.9 olan hastaların % 27.8’inde dental anomali görüldü. Kadınlarda anomali görülme prevalansı (% 30.3) erkeklere göre (% 23.8) anlamlı olarak daha yüksekti. Anomaliye sahip kadınlarda ise biçim anomalisi (% 68.6) ve alt tipi olarak talon tüberkülü (% 40.3) prevalansı anlamlı olarak yüksekti. Diğer anomali alt tipleri ve cinsiyetler arasında istatistiksel olarak anlamlı bir fark yoktu. En sık, sırasıyla talon tüberkülü (% 36.1), dilaserasyon (% 15.3), median diastema (% 12.8), tek diş eksikliği (% 11.9) ve dens in dente (% 11.6) alt tiplerine rastlanıldı. Sonuç: Her dört hastadan birinde dental anomaliye rastlama ihtimali olduğunu gösteren çalışmanın sonucu, başvuran her hastadan panoramik radyografi alınmasının ve detaylı bir incelemenin önemini bir kez daha ortaya koymuştur.
- Open Access
- 23 June 2023
- Published by Cumhuriyet University in Cumhuriyet Dental Journal
- Vol. 26 (2) , 180-187
Yeni Nesil Bulk-Fill Kompozitlerin Yüzey Pürüzlülüğü ve Mikro Sertliğinin Değerlendirilmesi
Objectives: The main objective of the study was to evaluate and compared the surface roughness and microhardness of three bulk-fill (ACTIVA Bioactive Restorative, SonicFill 2 SingleFill and SDR Flow Plus) and one conventional (G-aenial Posterior) composite resin at different depths. Materials and Methods: Eighty disc-shaped composite resins (6mm diameter, 2mm height) were polymerized as recommended and then subjected to the appropriate finishing and polishing procedure. Transparent strips were placed between the samples before polymerization to evaluate the hardness at different depths (0-2mm and 2-4mm) of the bulk-fill composites. Microhardness was evaluated with a Vickers hardness tester and roughness was evaluated with an optical profilometer. The ANOVA and Tukey multiple comparisons were performed for the statistical evaluation of microhardness and ANOVA was performed for roughness. Results: No statistically significant difference was determined between the composite materials in respect of surface roughness (p=0.336). It was generally observed that as the layer thickness increased in all the materials, the hardness values decreased (p<0.0001). SF was determined to have higher microhardness values in all the layers compared to the other samples (p<0.001). Conclusions: While SF had the highest microhardness values in different layers, SDR was of equivalent value to a conventional composite. However, the hardness values of ACT in all layers were statistically significantly lower than conventional and other bulk-fillers.
- 23 June 2023
- Published by Cumhuriyet University in Cumhuriyet Dental Journal
- Vol. 26 (2) , 180-187
Open AccessYeni Nesil Bulk-Fill Kompozitlerin Yüzey Pürüzlülüğü ve Mikro Sertliğinin Değerlendirilmesi
Objectives: The main objective of the study was to evaluate and compared the surface roughness and microhardness of three bulk-fill (ACTIVA Bioactive Restorative, SonicFill 2 SingleFill and SDR Flow Plus) and one conventional (G-aenial Posterior) composite resin at different depths. Materials and Methods: Eighty disc-shaped composite resins (6mm diameter, 2mm height) were polymerized as recommended and then subjected to the appropriate finishing and polishing procedure. Transparent strips were placed between the samples before polymerization to evaluate the hardness at different depths (0-2mm and 2-4mm) of the bulk-fill composites. Microhardness was evaluated with a Vickers hardness tester and roughness was evaluated with an optical profilometer. The ANOVA and Tukey multiple comparisons were performed for the statistical evaluation of microhardness and ANOVA was performed for roughness. Results: No statistically significant difference was determined between the composite materials in respect of surface roughness (p=0.336). It was generally observed that as the layer thickness increased in all the materials, the hardness values decreased (p<0.0001). SF was determined to have higher microhardness values in all the layers compared to the other samples (p<0.001). Conclusions: While SF had the highest microhardness values in different layers, SDR was of equivalent value to a conventional composite. However, the hardness values of ACT in all layers were statistically significantly lower than conventional and other bulk-fillers.
- 13 May 2023
- Published by Ankara Dis Hekimleri Odasi in ADO Klinik Bilimler Dergisi
- Vol. 12 (2) , 204-213
Comparison of the Microhardness and Surface Roughness Values of a New Composite After the Application of Different Polishing Systems with Current Composite Resins
Amaç: Bu çalışmanın amacı yeni mikrohibrit özellikli bir dental kompozitin mekanik özelliklerinden yüzey pürüzlülüğü ve mikrosertliğini piyasada yaygın olarak kullanılan farklı mikrohibrit ve nanohibrit kompozitlerle karşılaştırmaktır. Gereç ve Yöntem: Yeni üretilen Dolgunn (Himg Seramik ve Medikal Kompozit San.Tic. Ltd.Sti, Türkiye) kompoziti, G- aenial (GC, Japonya) ve Filtek Z250 (3M, ABD) ile hazırlanan örneklere mikrosertlik test cihazı ile ölçümler yapıldı. Yüzey pürüzlülüğü testi için Dolgunn, G- aenial, Ceram.x Spectra (Dentsply Sirona, Almanya) ve Filtek Ultimate (3M, ABD) örneklerine Clearfil Twist Dia (Kuraray, Japonya) ve Soft-lex (3M, ABD) sistemleri uygulandı. Mikrosertliklerinin karşılaştırılması tek yönlü varyans analizi (ANOVA) ve çoklu karşılaştırmalarda Tukey HSD testi, yüzey pürüzlülüklerinin karşılaştırılmasında Kruskal-Wallis ve çoklu karşılaştırmalarda Bonferroni düzeltmeli Mann-Whitney U testi kullanılmıştır. Polisaj sistemine göre karşılaştırmalarda ise Mann-Whitney U testi kullanılmıştır. Bulgular: Bulgular incelendiğinde Dolgunn ve Filtek Z250 kompozitleri arasında mikrosertlik değerleri açısından farklılık bulunmamıştır (p=0.661). G-aenial kompoziti ise diğer kompozitlerden istatiksel farklı olarak daha düşük sertlikte bulunmuştur (p<0.05). Dört farklı kompozite iki aşamalı ve çok aşamalı cila sistemleri uygulanmasının pürüzlülük değerleri karşılaştırmasında istatiksel olarak farklılık bulunmuştur (p<0.001). Sonuç: Dolgunn kompoziti yeterli mikrosertlik düzeyine ve parlatılabilirliğe sahip bulundu. Çalışmamızın sonuçlarına göre yeni formülasyon bir kompozit olan Dolgunn kompozit dolgu materyalinin daha kapsamlı mekanik ve klinik testler ile değerlendirilmesi gerektiği öngörülmektedir.
- 13 May 2023
- Published by Ankara Dis Hekimleri Odasi in ADO Klinik Bilimler Dergisi
- Vol. 12 (2) , 204-213
Comparison of the Microhardness and Surface Roughness Values of a New Composite After the Application of Different Polishing Systems with Current Composite Resins
Amaç: Bu çalışmanın amacı yeni mikrohibrit özellikli bir dental kompozitin mekanik özelliklerinden yüzey pürüzlülüğü ve mikrosertliğini piyasada yaygın olarak kullanılan farklı mikrohibrit ve nanohibrit kompozitlerle karşılaştırmaktır. Gereç ve Yöntem: Yeni üretilen Dolgunn (Himg Seramik ve Medikal Kompozit San.Tic. Ltd.Sti, Türkiye) kompoziti, G- aenial (GC, Japonya) ve Filtek Z250 (3M, ABD) ile hazırlanan örneklere mikrosertlik test cihazı ile ölçümler yapıldı. Yüzey pürüzlülüğü testi için Dolgunn, G- aenial, Ceram.x Spectra (Dentsply Sirona, Almanya) ve Filtek Ultimate (3M, ABD) örneklerine Clearfil Twist Dia (Kuraray, Japonya) ve Soft-lex (3M, ABD) sistemleri uygulandı. Mikrosertliklerinin karşılaştırılması tek yönlü varyans analizi (ANOVA) ve çoklu karşılaştırmalarda Tukey HSD testi, yüzey pürüzlülüklerinin karşılaştırılmasında Kruskal-Wallis ve çoklu karşılaştırmalarda Bonferroni düzeltmeli Mann-Whitney U testi kullanılmıştır. Polisaj sistemine göre karşılaştırmalarda ise Mann-Whitney U testi kullanılmıştır. Bulgular: Bulgular incelendiğinde Dolgunn ve Filtek Z250 kompozitleri arasında mikrosertlik değerleri açısından farklılık bulunmamıştır (p=0.661). G-aenial kompoziti ise diğer kompozitlerden istatiksel farklı olarak daha düşük sertlikte bulunmuştur (p<0.05). Dört farklı kompozite iki aşamalı ve çok aşamalı cila sistemleri uygulanmasının pürüzlülük değerleri karşılaştırmasında istatiksel olarak farklılık bulunmuştur (p<0.001). Sonuç: Dolgunn kompoziti yeterli mikrosertlik düzeyine ve parlatılabilirliğe sahip bulundu. Çalışmamızın sonuçlarına göre yeni formülasyon bir kompozit olan Dolgunn kompozit dolgu materyalinin daha kapsamlı mekanik ve klinik testler ile değerlendirilmesi gerektiği öngörülmektedir.