Danial Adib
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Danial Adib has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Hossein Tabeshkia
Department of Environment, Islamic Azad University, Tehran, Iran
2 shared publicationsRoya Mafigholami
Islamic Azad University
1 shared publication- Roya Mafigholami
Department of Environment, West Tehran Branch, Islamic Azad University, Tehran, Iran
1 shared publication Tony R. Walker
School for Resource and Environmental Studies, Dalhousie University, Halifax, Canada
1 shared publication
Latest Publications
- 10 May 2022
- Published by Springer Nature in Journal of Environmental Health Science and Engineering
- Vol. 20 (1) , 565-577
Optimization of polypropylene microplastics removal using conventional coagulants in drinking water treatment plants via response surface methodology
Background and purpose The ubiquitous presence of microplastics (MPs) in aquatic environments has been studied widely. Due to toxicological impacts of MPs and associated contaminants, it is crucial to understand the performance of MPs removal in drinking water treatment plants (DWTPs). Few studies have investigated removal characteristics of MPs via coagulation/flocculation processes, yet removal characterization of polypropylene microplastics (PPMPs) in this process is poorly understood. This study aims to optimize coagulation of virgin PPMPs in conventional DWTPs. Methods In this study, samples were synthesized through response surface methodology (RSM), polyaluminium chloride (PACl) was applied as a conventional coagulant to remove PPMPs in the coagulation/flocculation process, which has the least density among common polymers and is one of the most abundant manufactured polymers worldwide. A particle size analyzer (PSA) was used to measure floc size at different pH levels. Additionally, a zeta potential analyzer was used to measure stability of the flocs at different pH. Results Base on the experimental range in Design-Expert, results revealed that the optimum removal rate was predicted to be at pH 9, PACl concentration of 200 ppm, polyacrylamide (PAM) concentration of 21 ppm, and PPMPs size of d < 0.25 mm. According to the predicted optimum condition, actual and predicted removal rates were 18.00 ± 1.43% and 19.69%, respectively. Conclusion According to this study, PACl is not capable of efficiently removing virgin PPMPs in DWTPs, thereby exposing humans to eco-toxicological impacts of PPMPs through tap water.
- 10 May 2022
- Published by Springer Nature in Journal of Environmental Health Science and Engineering
- Vol. 20 (1) , 565-577
Optimization of polypropylene microplastics removal using conventional coagulants in drinking water treatment plants via response surface methodology
Background and purpose The ubiquitous presence of microplastics (MPs) in aquatic environments has been studied widely. Due to toxicological impacts of MPs and associated contaminants, it is crucial to understand the performance of MPs removal in drinking water treatment plants (DWTPs). Few studies have investigated removal characteristics of MPs via coagulation/flocculation processes, yet removal characterization of polypropylene microplastics (PPMPs) in this process is poorly understood. This study aims to optimize coagulation of virgin PPMPs in conventional DWTPs. Methods In this study, samples were synthesized through response surface methodology (RSM), polyaluminium chloride (PACl) was applied as a conventional coagulant to remove PPMPs in the coagulation/flocculation process, which has the least density among common polymers and is one of the most abundant manufactured polymers worldwide. A particle size analyzer (PSA) was used to measure floc size at different pH levels. Additionally, a zeta potential analyzer was used to measure stability of the flocs at different pH. Results Base on the experimental range in Design-Expert, results revealed that the optimum removal rate was predicted to be at pH 9, PACl concentration of 200 ppm, polyacrylamide (PAM) concentration of 21 ppm, and PPMPs size of d < 0.25 mm. According to the predicted optimum condition, actual and predicted removal rates were 18.00 ± 1.43% and 19.69%, respectively. Conclusion According to this study, PACl is not capable of efficiently removing virgin PPMPs in DWTPs, thereby exposing humans to eco-toxicological impacts of PPMPs through tap water.
- Open Access
- 2 March 2021
- Published by Springer Nature in Research Square
Identification of Microplastics in Conventional Drinking Water Treatment Plants in Tehran, Iran
The presence of microplastics (MPs), as an emerging pollutant is a growing concern in different water resources. These particles are recognized as less than 5 mm in size. Most of the studies have been carried out in surface waters and wastewater treatment plants (WWTPs), but there are few studies on MPs in drinking water treatment plants (DWTPs). This study investigates these particles in three different conventional DWTPs in the city of Tehran, Iran and aims to analyze these particles down to the size of 1 µm. A scanning electron microscope (SEM) was utilized in this study to quantitatively analyze MPs. Accordingly, the average abundance of MPs in raw and treated water samples varied from 1996±268 to 2808±80 MPs L-1 and 971±103 to 1401±86 MPs L-1, respectively. While particles smaller than 10 µm comprised 65-87% of MPs. Moreover, µ-Raman spectroscopy was used to characterize MPs. As the results, polypropylene (PP), polyethylene terephthalate (PET), and polyethylene (PE) were the most abundant identified polymers among MPs comprising more than 53% of particles. Additionally, MPs were categorized as fibers, fragments and spheres. This study fills the knowledge gap of MPs presence in Tehran DWTPs which is of high importance since they supply drinking water for more than 8 million people and investigates the performance of conventional DWTPs in removing MPs.
- 2 March 2021
- Published by Springer Nature in Research Square
Open AccessIdentification of Microplastics in Conventional Drinking Water Treatment Plants in Tehran, Iran
The presence of microplastics (MPs), as an emerging pollutant is a growing concern in different water resources. These particles are recognized as less than 5 mm in size. Most of the studies have been carried out in surface waters and wastewater treatment plants (WWTPs), but there are few studies on MPs in drinking water treatment plants (DWTPs). This study investigates these particles in three different conventional DWTPs in the city of Tehran, Iran and aims to analyze these particles down to the size of 1 µm. A scanning electron microscope (SEM) was utilized in this study to quantitatively analyze MPs. Accordingly, the average abundance of MPs in raw and treated water samples varied from 1996±268 to 2808±80 MPs L-1 and 971±103 to 1401±86 MPs L-1, respectively. While particles smaller than 10 µm comprised 65-87% of MPs. Moreover, µ-Raman spectroscopy was used to characterize MPs. As the results, polypropylene (PP), polyethylene terephthalate (PET), and polyethylene (PE) were the most abundant identified polymers among MPs comprising more than 53% of particles. Additionally, MPs were categorized as fibers, fragments and spheres. This study fills the knowledge gap of MPs presence in Tehran DWTPs which is of high importance since they supply drinking water for more than 8 million people and investigates the performance of conventional DWTPs in removing MPs.