YLYi-Chao Luan

Yi-Chao Luan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yi-Chao Luan has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In Vitro Analysis of Wearing of Hip Joint Prostheses Composed of Different Contact Materials

    by Jian Su, Jian-Jun Wang, Shi-Tong Yan, Min Zhang, Hui-Zhi Wang, Ning-Ze Zhang, Yi-Chao Luan, Cheng-Kung Cheng

    Cobalt-chromium-molybdenum alloy (CoCrMo) and ceramic are the two most common materials for the femoral head in hip joint prostheses, and the acetabular liner is typically made from ultra-high molecular weight polyethylene (UHMWPE), highly cross-linked polyethylene (XLPE), or highly cross-linked polyethylene blended with Vitamin E (VEXLPE). The selection of suitable materials should consider both wear performance and cost-effectiveness. This study compared the wear rate between different friction pairs using a hip joint simulator and then recommended a suitable prosthesis based on the corresponding processing technology and cost. All wear simulations were performed in accordance with ISO 14242, using the same hip joint simulator and same test conditions. This study found that when using the same material for the femoral head, the XLPE and VEXLPE liners had a lower wear rate than the UHMWPE liners, and the wear rate of the XLPE liners increased after blending with Vitamin E (VEXLPE). There was no significant difference in the wear rate of XLPE when using a CoCrMo or ceramic head. Considering the wear rate and cost-effectiveness, a CoCrMo femoral head with an accompanying XLPE liner is recommended as the more suitable combination for hip prostheses.


  • Open Access

    Wear Assessment of Tibial Inserts Made of Highly Cross-Linked Polyethylene Supplemented with Dodecyl Gallate in the Total Knee Arthroplasty

    by Min Zhang, Jia-Yu Wang, Jian Su, Jian-Jun Wang, Shi-Tong Yan, Yi-Chao Luan, Cheng-Kung Cheng

    Background: the wear of tibial insert is still one of primary factors leading to failure of total knee arthroplasty (TKA). Dodecyl gallate (DG) has shown improvements in the oxidation stability of highly cross-linked polyethylene (HXLPE). This study aimed to assess the application of HXLPE supplemented with DG (HXLPE-DG) on the tibial insert in TKA concerning the wear resistance and the potential impact on implant fixation; Methods: tibial inserts made of HXLPE-DG were subjected to a 3 million loading-cycle wear test following ISO 14243-1:2009. The loss of mass and wear rate of the tibial inserts were calculated. The quantity, size,- and shape of wear particles were recorded; Results: the test specimens lost an average mass of 16.00 mg ± 0.94 mg, and were on an average wear rate of 3.92 mg/million cycles ± 0.19 mg/million cycles. The content of wear particles in the calf serum medium was 3.94 × 108 particles/mL ± 3.93 × 107 particles/mL, 96.66% ± 0.77% of the particles had an equivalent circular diameter less than 0.5 μm. The aspect ratio of wear particles was 1.40 (min: 1.01; max: 6.42). Conclusions: HXLPE-DG displayed advantages over the commonly used materials for tibial inserts and presented the potential of application in TKA.


  • Open Access

    Association between Proximal Tibiofibular Joint Morphology and Knee Alignment in Osteoarthritis Patients

    by Xin-Zheng Qi, Min Zhang, Mao-Dan Nie, Xiao-Ying Ma, Yi-Chao Luan, Cheng-Kung Cheng, Min Wang

    This study aimed to determine whether proximal tibiofibular joint (PTFJ) morphology was related to knee alignment in osteoarthritis (OA) patients. Methods: 67 OA patients were enrolled in this study. The morphology of the PTFJ including articular shape type, articular surface area, joint inclination, relative articular height, and joint declination were measured from 3D models. The knee alignment of each subject was characterized as varus, normal, or valgus according to the femorotibial angle (FTA). The FTA was measured on weight-bearing X-rays. Multinomial logistic regression analysis was used to evaluate the association between PTFJ morphology and knee alignment. Results: there were significant differences between varus, valgus, and normal FTA groups in terms of shape type (p = 0.021), inclination of the PTFJ (p = 0.025), relative articular height (p = 0.019), and PTFJ declination angle (p = 0.011). A higher relative articular height (OR: 0.608, 95% CI: 0.205–0.998, and p = 0.017) and lower declination angle (OR: 0.632, 95% CI: 0.601–0.887, and p =0.019) were found to be associated with an increased likelihood of having a valgus FTA rather than a varus FTA. Conclusion: our results indicate that PTFJ morphology is associated with knee alignment.