XYXiaodong Yin

Xiaodong Yin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaodong Yin has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A 1 kV Compensation-Free Three-Stage Inductive Voltage Divider with Integrated-Reference Self-Calibration

    by Jian Wang, Xiaodong Yin, Hao Liu, Junjie Liu, Jian Liu, Shuhui Yi, Jiahao Sun, Junjun Huang, Wenbo Sun

    Electronic compensation networks used in high–accuracy inductive voltage dividers (IVDs) can introduce temperature– and aging–dependent drift sources, complicating long–term uncertainty evaluation. This paper presents a 1 kV, 10–tap, compensation–free three–stage IVD that combines multi–stage excitation, a closed shielded core, and equipotential coaxial–cable windings to suppress excitation, magnetic–coupling, and capacitive errors. An integrated reference winding is embedded in the third–stage coaxial–cable winding, enabling a simplified bootstrap self–calibration procedure without an additional auxiliary IVD. At 50 Hz, the calibrated ratio error and phase displacement are within 0.08 μV/V and 0.08 μrad, respectively, for all taps, with expanded uncertainties of 0.04 μV/V and 0.06 μrad. Wideband measurements up to 3 kHz further show that the proposed IVD can serve as a voltage–ratio reference for harmonic voltage measurement and calibration.

  • Precision Two-Stage Voltage Transformer for a Wide Voltage Range of 5–40 kV

    by Hao Liu, Enrico Mohns, Johann Meisner, Chunyang Jiang, Feng Zhou, Xiaodong Yin, Lixue Chen

    A two-stage voltage transformer (VT) with several rated transformer ratios and with a rated maximum voltage of 40 kV and a rated minimum voltage of 5 kV has been designed. To guarantee high accuracy over the full medium voltage range, the primary winding has been split into 4 primary windings, which can be configured in three different series and parallel connections. With five windings of the secondary, 15 different voltage ratios can be accomplished. This connection scheme, which is already used in older commercial standard VTs of the error class 0.02, achieves a very low effective output resistance, which in turn results in very small additional errors of less than 0.5·10 -6 due to the loading by the input of the transformer bridge. According to the measuring results, for all the 15 different ratios, the error is less than 20 μV/V for ratio error and 20 μrad for phase displacement.

  • Open Access

    Nonintrusive Load Identification for Industrial Users Integrated with LSQR and Sequential Leader Clustering

    by Shuhui Yi, Yinglong Diao, Junjie Liu, Tian Fang, Xiaodong Yin

    Nonintrusive load identification for industrial users can accurately acquire the operation of each load. However, it is a major challenge in the demand-side response due to the hardship of collection data for modelling, and high precision measuring equipment is required. Aiming at this situation, a nonintrusive load identification method is proposed, combining the least square QR (LSQR) with the sequential leader clustering algorithm. Firstly, regarding accurate depiction of industrial loads, some appropriate load feature indices of steady-state and transient processes are extracted, respectively. For steady-state processes, the active power, the reactive power, and the root mean square (RMS) current value are selected as the feature indices. In the case of transient processes, ten feature indices of three stages are employed: before, during, and after transient events, consisting of the duration of transient events, the RMS current value before and after transient events, the average value of active power before and after transient events, the average value of reactive power before and after transient events, the maximum RMS current value of transient events, etc. On this base, the LSQR algorithm is proposed to decompose unknown composite power to access the operation of various loads at steady-state. The sequential leader clustering algorithm is propounded to classify transient events of typical industrial loads and further identify which kind of loads had switched. Finally, to validate the effectiveness of the presented model, data of industrial loads from a concrete plant are collected, including blender, cement screw, sewage dump, and inclined belt conveyor, and simulation analysis is fulfilled. The results indicate that the model proposed can effectively achieve the nonintrusive industrial load identification, and least unified residue (LUR) is about 10−16, which is much better than the factorial hidden Markov model (FHMM) and the artificial neural network (ANN) model.


  • The Development of Precision 500/√3-kV Two-Stage Voltage Transformer With High-Voltage Excitation

    by Hao Liu, Feng Zhou, Lixue Chen, Min Lei, Xiaodong Yin, Chunyang Jiang, Jian Liu

    Two-stage voltage transformer (VT) based on high-voltage excitation is usually less than 10 kV due to insulation limitation. To develop a two-stage VT with high-voltage excitation above 10 kV, this article designed two feasible structures. By calculating and comparing the lengths of the magnetic path, a better structural scheme was selected. The excitation winding and the precise ratio winding are in an “up-and-down” structure. This makes it work at a higher voltage possible. Moreover, a flexible compensation circuit was added to the secondary of this two-stage VT to acquire higher accuracy. Based on the principle, a 500/√3-kV two-stage VT has been developed. The half-symmetry summation method was used to calibrate this two-stage VT. The measurement results indicate that the voltage coefficient is very low. The error is (-2.2 to +3.1) μV/V for the ratio error and (-2.6 to -0.2) μrad for the phase displacement in the range of (20%-120%) rated voltage.