Eylem Topkaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eylem Topkaya has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Ayla Arslan
Department of Environmental Engineering, Kocaeli University, Kocaeli, Turkey
8 shared publications - Sevil Veli
Kocaeli Üniversitesi
6 shared publications Ayla Arslan
Environmental Engineering Department Kocaeli University Kocaeli Türkiye
4 shared publications- Melike Isgoren
KOCAELI UNIVERSITY, İZMİT VOCATIONAL SCHOOL, DEPARTMENT OF ENVIRONMENTAL PROTECTION AND TECHNOLOGIES, ENVIRONMENTAL PROTECTION AND CONTROL PR
4 shared publications - Mesut Sezer
Department of Environmental Engineering, Kocaeli University, Kocaeli, Turkey
4 shared publications - Anatoli Dimoglo
DÜZCE ÜNİVERSİTESİ, MÜHENDİSLİK FAKÜLTESİ
3 shared publications
Latest Publications
- 8 July 2026
- Published by Wiley in Environmental Progress & Sustainable Energy
- p. e70579
Treatment of pharmaceutical industry wastewater through integrated and sequential processes: Electro‐Fenton coupled with ozone/ UV and electro‐Fenton with photocatalytic oxidation
The pharmaceutical industry wastewater was treated by applying O 3 , UV, EF, and PcO processes individually, hybrid, and sequentially. Individual experimental studies of O 3 , O 3 /UVC, EF, and PcO treatment processes were initially carried out in the batch mode. The max TOC removal efficiencies were 13%, 24%, 42%, and 48%, respectively. It was found that single usage of these processes could not be adequate due to the diversity of resistant organic matters in wastewater. Firstly, the EF process was carried out to degrade and decompose resistant organic pollutants, and O 3 /UVC or PcO was then sequentially applied to eliminate and mineralize remaining organic compounds from wastewater. The sequential implementation performances of EF‐O 3 /UVC and EF‐PcO processes were investigated using different process conditions (ozone dosage, light type, current densities, catalysts, etc.). TOC reduction values were obtained as 79% and 80% with sequential treatment systems, respectively. The energy consumptions of these processes were calculated as 537.46 kWh/kg TOC and 2503.43 kWh/kg TOC. Results indicated that the enhanced treatment performance originated from the integrated operation of the processes rather than from the efficiencies of the individual processes alone.
- 8 July 2026
- Published by Wiley in Environmental Progress & Sustainable Energy
- p. e70579
Treatment of pharmaceutical industry wastewater through integrated and sequential processes: Electro‐Fenton coupled with ozone/ UV and electro‐Fenton with photocatalytic oxidation
The pharmaceutical industry wastewater was treated by applying O 3 , UV, EF, and PcO processes individually, hybrid, and sequentially. Individual experimental studies of O 3 , O 3 /UVC, EF, and PcO treatment processes were initially carried out in the batch mode. The max TOC removal efficiencies were 13%, 24%, 42%, and 48%, respectively. It was found that single usage of these processes could not be adequate due to the diversity of resistant organic matters in wastewater. Firstly, the EF process was carried out to degrade and decompose resistant organic pollutants, and O 3 /UVC or PcO was then sequentially applied to eliminate and mineralize remaining organic compounds from wastewater. The sequential implementation performances of EF‐O 3 /UVC and EF‐PcO processes were investigated using different process conditions (ozone dosage, light type, current densities, catalysts, etc.). TOC reduction values were obtained as 79% and 80% with sequential treatment systems, respectively. The energy consumptions of these processes were calculated as 537.46 kWh/kg TOC and 2503.43 kWh/kg TOC. Results indicated that the enhanced treatment performance originated from the integrated operation of the processes rather than from the efficiencies of the individual processes alone.
- 3 July 2026
- Published by Pamukkale University in Pamukkale University Journal of Engineering Sciences
- No. Advanced O
Polietilen streç film üretiminden kaynaklı atıksulardaki mikroplastiklerin ozon prosesi ile arıtımında Taguchi deneysel optimizasyon uygulaması
Arka Plan— Gıda ambalajlamada yaygın olarak kullanılan polietilen (PE) streç filmler; taşıma, ürün koruma ve kullanım kolaylığı gibi avantajları nedeniyle endüstride tercih edilmektedir. Ancak üretim süreçlerinde kullanılan soğutma sularına PE kaynaklı plastik parçacıkların geçiş riski bulunmaktadır. Bu plastiklerin alıcı ortamlara taşınması, sucul ekosistemlerde birikmelerine ve zamanla besin zincirine dâhil olmalarına yol açabilmektedir. Sonuç olarak, bu kirleticiler organizmaların fizyolojik işlevleri üzerinde olumsuz etkilere neden olmakta ve ekosistem sağlığı açısından önemli bir çevresel risk oluşturmaktadır.Amaç— Polietilen (PE) üretim sürecinde kullanılan soğutma suyunun karakterizasyonu yapılarak bu suda bulunan mikroplastikler (MP’ler) belirlenmiştir. Daha sonra, belirlenen MP’lerin ozon prosesi ile giderimi Taguchi deneysel tasarım yöntemi kullanılarak araştırılmış ve proses koşullarının optimize edilebilirliği amaçlanmıştır.Yöntem— Soğutma suyunda bulunan mikroplastiklerin (MP’lerin) tayini, mikroskop altında görsel inceleme yöntemiyle gerçekleştirilmiştir. MP’lerin giderimi amacıyla, oksidasyonu zor olan bileşikleri hızlı ve etkili şekilde parçalayabilen ozon prosesi tercih edilmiştir. Bu kapsamda, laboratuvar ortamında bir ozon jeneratörü kullanılarak üretilen ozon ile MP’lerin oksidasyon çalışmaları yürütülmüştür. Deneysel çalışmalar, az sayıda deneyle kısa sürede güvenilir sonuçlar elde edilmesine olanak tanıyan Taguchi deneysel tasarım yöntemi kullanılarak planlanmıştır. Ozon prosesinde pH (4, 7 ve 10), ozon dozu (5, 7.5 ve 10 mg/L) ve reaksiyon süresi (15, 30 ve 45 dk.) değişkenlerinin MP giderim verimi üzerindeki etkileri incelenmiştir.Bulgular— Çalışılan atıksuda baskın MP türü fiber olup, 45-55 adet/L tespit edilmiştir. Taguchi deneysel tasarımı kapsamında elde edilen sinyal-gürültü oranı (SN; signal to noise ratio) ve ortalama değerler için hesaplanan R² değerleri sırasıyla 0.98 ve 0.99 olup, modelin deneysel verilerle yüksek uyum gösterdiğini ortaya koymuştur. Mikroplastik (MP) gideriminin maksimize edilmesi hedeflendiğinden, çalışmada “daha yüksek daha iyidir” Taguchi yaklaşımı tercih edilmiştir. Bu yaklaşım doğrultusunda yapılan analizler sonucunda, optimum proses koşulları pH 7, ozon dozu 10 mg/L ve reaksiyon süresi 45 dakika olarak belirlenmiştir. Belirlenen bu koşullar altında MP giderim veriminin %80’in üzerinde olduğu tespit edilmiştir. Sonuç— Bu çalışma, PE streç film üretim süreçlerinde kullanılan soğutma sularının arıtımında Taguchi deneysel tasarım yönteminin, optimum proses koşullarının belirlenmesinde etkin ve uygulanabilir bir araç olduğunu göstermiştir. Yöntemin sağladığı sistematik yaklaşım sayesinde, sınırlı sayıda deney ile kısa sürede güvenilir ve tekrarlanabilir sonuçlar elde edilmiştir. Bununla birlikte, elde edilen bulgular ozon prosesinin, soğutma sularında bulunan mikroplastiklerin gideriminde yüksek verim sağlayan, etkili ve uygulanabilir bir ileri arıtım alternatifi olduğunu ortaya koymuştur. Ayrıca bu prosesin endüstriyel ölçekte soğutma suyu yönetimi ve çevresel risklerin azaltılması açısından önemli bir potansiyele sahip olduğunu göstermiştir.
- 3 July 2026
- Published by Pamukkale University in Pamukkale University Journal of Engineering Sciences
- No. Advanced O
Polietilen streç film üretiminden kaynaklı atıksulardaki mikroplastiklerin ozon prosesi ile arıtımında Taguchi deneysel optimizasyon uygulaması
Arka Plan— Gıda ambalajlamada yaygın olarak kullanılan polietilen (PE) streç filmler; taşıma, ürün koruma ve kullanım kolaylığı gibi avantajları nedeniyle endüstride tercih edilmektedir. Ancak üretim süreçlerinde kullanılan soğutma sularına PE kaynaklı plastik parçacıkların geçiş riski bulunmaktadır. Bu plastiklerin alıcı ortamlara taşınması, sucul ekosistemlerde birikmelerine ve zamanla besin zincirine dâhil olmalarına yol açabilmektedir. Sonuç olarak, bu kirleticiler organizmaların fizyolojik işlevleri üzerinde olumsuz etkilere neden olmakta ve ekosistem sağlığı açısından önemli bir çevresel risk oluşturmaktadır.Amaç— Polietilen (PE) üretim sürecinde kullanılan soğutma suyunun karakterizasyonu yapılarak bu suda bulunan mikroplastikler (MP’ler) belirlenmiştir. Daha sonra, belirlenen MP’lerin ozon prosesi ile giderimi Taguchi deneysel tasarım yöntemi kullanılarak araştırılmış ve proses koşullarının optimize edilebilirliği amaçlanmıştır.Yöntem— Soğutma suyunda bulunan mikroplastiklerin (MP’lerin) tayini, mikroskop altında görsel inceleme yöntemiyle gerçekleştirilmiştir. MP’lerin giderimi amacıyla, oksidasyonu zor olan bileşikleri hızlı ve etkili şekilde parçalayabilen ozon prosesi tercih edilmiştir. Bu kapsamda, laboratuvar ortamında bir ozon jeneratörü kullanılarak üretilen ozon ile MP’lerin oksidasyon çalışmaları yürütülmüştür. Deneysel çalışmalar, az sayıda deneyle kısa sürede güvenilir sonuçlar elde edilmesine olanak tanıyan Taguchi deneysel tasarım yöntemi kullanılarak planlanmıştır. Ozon prosesinde pH (4, 7 ve 10), ozon dozu (5, 7.5 ve 10 mg/L) ve reaksiyon süresi (15, 30 ve 45 dk.) değişkenlerinin MP giderim verimi üzerindeki etkileri incelenmiştir.Bulgular— Çalışılan atıksuda baskın MP türü fiber olup, 45-55 adet/L tespit edilmiştir. Taguchi deneysel tasarımı kapsamında elde edilen sinyal-gürültü oranı (SN; signal to noise ratio) ve ortalama değerler için hesaplanan R² değerleri sırasıyla 0.98 ve 0.99 olup, modelin deneysel verilerle yüksek uyum gösterdiğini ortaya koymuştur. Mikroplastik (MP) gideriminin maksimize edilmesi hedeflendiğinden, çalışmada “daha yüksek daha iyidir” Taguchi yaklaşımı tercih edilmiştir. Bu yaklaşım doğrultusunda yapılan analizler sonucunda, optimum proses koşulları pH 7, ozon dozu 10 mg/L ve reaksiyon süresi 45 dakika olarak belirlenmiştir. Belirlenen bu koşullar altında MP giderim veriminin %80’in üzerinde olduğu tespit edilmiştir. Sonuç— Bu çalışma, PE streç film üretim süreçlerinde kullanılan soğutma sularının arıtımında Taguchi deneysel tasarım yönteminin, optimum proses koşullarının belirlenmesinde etkin ve uygulanabilir bir araç olduğunu göstermiştir. Yöntemin sağladığı sistematik yaklaşım sayesinde, sınırlı sayıda deney ile kısa sürede güvenilir ve tekrarlanabilir sonuçlar elde edilmiştir. Bununla birlikte, elde edilen bulgular ozon prosesinin, soğutma sularında bulunan mikroplastiklerin gideriminde yüksek verim sağlayan, etkili ve uygulanabilir bir ileri arıtım alternatifi olduğunu ortaya koymuştur. Ayrıca bu prosesin endüstriyel ölçekte soğutma suyu yönetimi ve çevresel risklerin azaltılması açısından önemli bir potansiyele sahip olduğunu göstermiştir.
- 27 January 2025
- Published by Elsevier in Chemical Engineering Science
- Vol. 306, 121287
Microplastic removal by ozone oxidation in cooling wastewater of food packaging industry
- 27 January 2025
- Published by Elsevier in Chemical Engineering Science
- Vol. 306, 121287
Microplastic removal by ozone oxidation in cooling wastewater of food packaging industry
- 29 November 2024
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 100 (3) , 517-529
Treatability of diclofenac and triclosan solutions by catalytic and photocatalytic oxidation processes
BACKGROUND: In recent years, advanced oxidation processes (AOP) have gained importance as highly effective methods in the treatment of organic substances with toxic and permanent properties. Diclofenac (DCF) and Triclosan (TCS) pollutants, which are from the endocrine disrupting chemicals (EDCs) that were encountered in various aquatic environments such as inlet and outlet waters of treatment plants, surface waters, drinking water, groundwater and sediments were reported in the literature. In this study, mineralisation of DCF and TCS pollutants, which were the EDCs, were investigated by AOPs. The applied processes were O3, O3/UV, O3/ZnO, UV/ZnO, and O3/UV/ZnO. The studies were carried out at two different initial concentrations (5 and 10 mg/L), at 5 ppm ozone dose, 2 × 8 W UVC light, 0.1 g ZnO, in the original pH, and 30 min reaction time.RESULTS: The highest COD and TOC removal efficiencies were determined in O3/UV/ZnO process as 82% COD, 71% TOC at 5 mg/L concentration for DCF pollutant and as 72% COD, 75% TOC at 10 mg/L concentration for TCS pollutant. For these process conditions, the ozone consumptions were determined 0.13 mgO3/mgCODremoved, 0.31 mgO3/mgTOCremoved and 0.69 mgO3/mgCODremoved, 0.98 mgO3/mgTOCremoved, respectively. The electrical energy per order values were found in the range of 12.33–20.88 kWh/m3 for O3/UV/ZnO processes. Treatment costs of these processes were calculated in the range of 0.002 to 44.823 €/m3.CONCLUSION: For the treatability of DCF and TCS pollutants, ozone‐based advanced oxidation processes, especially O3/UV/ZnO photocatalytic ozone oxidation process were determined as a feasible process. © 2024 Society of Chemical Industry (SCI).
- 29 November 2024
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 100 (3) , 517-529
Treatability of diclofenac and triclosan solutions by catalytic and photocatalytic oxidation processes
BACKGROUND: In recent years, advanced oxidation processes (AOP) have gained importance as highly effective methods in the treatment of organic substances with toxic and permanent properties. Diclofenac (DCF) and Triclosan (TCS) pollutants, which are from the endocrine disrupting chemicals (EDCs) that were encountered in various aquatic environments such as inlet and outlet waters of treatment plants, surface waters, drinking water, groundwater and sediments were reported in the literature. In this study, mineralisation of DCF and TCS pollutants, which were the EDCs, were investigated by AOPs. The applied processes were O3, O3/UV, O3/ZnO, UV/ZnO, and O3/UV/ZnO. The studies were carried out at two different initial concentrations (5 and 10 mg/L), at 5 ppm ozone dose, 2 × 8 W UVC light, 0.1 g ZnO, in the original pH, and 30 min reaction time.RESULTS: The highest COD and TOC removal efficiencies were determined in O3/UV/ZnO process as 82% COD, 71% TOC at 5 mg/L concentration for DCF pollutant and as 72% COD, 75% TOC at 10 mg/L concentration for TCS pollutant. For these process conditions, the ozone consumptions were determined 0.13 mgO3/mgCODremoved, 0.31 mgO3/mgTOCremoved and 0.69 mgO3/mgCODremoved, 0.98 mgO3/mgTOCremoved, respectively. The electrical energy per order values were found in the range of 12.33–20.88 kWh/m3 for O3/UV/ZnO processes. Treatment costs of these processes were calculated in the range of 0.002 to 44.823 €/m3.CONCLUSION: For the treatability of DCF and TCS pollutants, ozone‐based advanced oxidation processes, especially O3/UV/ZnO photocatalytic ozone oxidation process were determined as a feasible process. © 2024 Society of Chemical Industry (SCI).
- 4 September 2024
- Published by Elsevier in Journal of Environmental Management
- Vol. 369, 122413
Optimizing microplastic treatment in the effluent of biological nutrient removal processes using electrocoagulation: Taguchi experimental design
- 4 September 2024
- Published by Elsevier in Journal of Environmental Management
- Vol. 369, 122413
Optimizing microplastic treatment in the effluent of biological nutrient removal processes using electrocoagulation: Taguchi experimental design
- 27 January 2024
- Published by Elsevier in Chemosphere
- Vol. 352, 141314
Removal of microplastics in food packaging industry wastewaters with electrocoagulation process: Optimization by Box-Behnken design
- 27 January 2024
- Published by Elsevier in Chemosphere
- Vol. 352, 141314
Removal of microplastics in food packaging industry wastewaters with electrocoagulation process: Optimization by Box-Behnken design
- 17 November 2023
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 234 (12) , 1-19
Treatment of Endocrine Disrupting Chemicals from Organized Industrial Zone Wastewater Treatment Plant Effluents by Ozone-Based AOPs: Cost and Toxicity Assessments
- 17 November 2023
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 234 (12) , 1-19
Treatment of Endocrine Disrupting Chemicals from Organized Industrial Zone Wastewater Treatment Plant Effluents by Ozone-Based AOPs: Cost and Toxicity Assessments
- 30 June 2023
- Published by Canakkale Onsekiz Mart University in Journal of Advanced Research in Natural and Applied Sciences
- Vol. 9 (2) , 355-374
Kentsel Atıksu Arıtma Tesisi İkinci Arıtma Çıkış Suyundan Nanofiltrasyon Prosesi İle Su Geri Kazanımı
Son yıllarda suyun kıt olduğu ve dolayısıyla suyun ekonomik değer taşıdığı yörelerde arıtılmış atıksulardan su geri kazanımına ve suyun yeniden kullanımına ilgi giderek artmaktadır. Bu çalışmada, kentsel ikincil arıtma çıkış sularına laboratuvar ölçeğinde NF (Nanofiltrasyon) prosesi uygulanarak, çıkış suyunun çeşitli amaçlar için geri kazanımında yüksek oranda organik/inorganik madde gideriminin yanısıra mikrobiyal kirliliğin de giderimi ile etkili bir su yönetimi yaklaşımı ortaya konması amaçlanmıştır. Deneysel çalışmalar “Taguchi Deneysel Tasarım” uygulaması ile planlanmıştır. Çalışmada transmembran basıncı (5; 7.5; 10 bar), VRF (hacim azaltma faktörü: 2; 3; 4) ve membran tipi (NP030; NF270; NF90) değişkenleri ve değişken seviyelerinin NF prosesi için “Yanıt Yüzey Yöntemi” ile optimizasyonu gerçekleştirilmiş olup en iyi performans 5 bar ve 2 VRF işletme şartları ile NF90 membran olarak belirlenmiştir. Doğrulama deneyi sonuçlarına göre çıkış suyunda toplam koliform değeri 6.8x106 kob/100 mL’den tespit edilemez düzeye kadar düşürülmüş, Kimyasal Oksijen İhtiyacı (KOİ) 14 mg/L ve Toplam Çözünmüş Katı (TÇK) 86 mg/L olarak tespit edilmiştir. Deney sonrası elde edilen NF süzüntü suyunun yeniden kullanılabilirliği, ulusal ve uluslararası mevzuatlara göre değerlendirilmiş, pH 6.5, Biyolojik Oksijen İhtiyacı (BOİ5) 9.6 mg/L olarak bulunmuş ve süzüntü suyunda fekal koliform ile Askıda Katı Madde (AKM)’ ye rastlanmamıştır. Buradan elde edilen süzüntü suyunun sulama amaçlı kullanıma uygun olduğu, ayrıca endüstriyel soğutma suyu ve yeraltı suyuna deşarj gibi farklı amaçlar için de kullanılabileceği görülmektedir.
- 30 June 2023
- Published by Canakkale Onsekiz Mart University in Journal of Advanced Research in Natural and Applied Sciences
- Vol. 9 (2) , 355-374
Kentsel Atıksu Arıtma Tesisi İkinci Arıtma Çıkış Suyundan Nanofiltrasyon Prosesi İle Su Geri Kazanımı
Son yıllarda suyun kıt olduğu ve dolayısıyla suyun ekonomik değer taşıdığı yörelerde arıtılmış atıksulardan su geri kazanımına ve suyun yeniden kullanımına ilgi giderek artmaktadır. Bu çalışmada, kentsel ikincil arıtma çıkış sularına laboratuvar ölçeğinde NF (Nanofiltrasyon) prosesi uygulanarak, çıkış suyunun çeşitli amaçlar için geri kazanımında yüksek oranda organik/inorganik madde gideriminin yanısıra mikrobiyal kirliliğin de giderimi ile etkili bir su yönetimi yaklaşımı ortaya konması amaçlanmıştır. Deneysel çalışmalar “Taguchi Deneysel Tasarım” uygulaması ile planlanmıştır. Çalışmada transmembran basıncı (5; 7.5; 10 bar), VRF (hacim azaltma faktörü: 2; 3; 4) ve membran tipi (NP030; NF270; NF90) değişkenleri ve değişken seviyelerinin NF prosesi için “Yanıt Yüzey Yöntemi” ile optimizasyonu gerçekleştirilmiş olup en iyi performans 5 bar ve 2 VRF işletme şartları ile NF90 membran olarak belirlenmiştir. Doğrulama deneyi sonuçlarına göre çıkış suyunda toplam koliform değeri 6.8x106 kob/100 mL’den tespit edilemez düzeye kadar düşürülmüş, Kimyasal Oksijen İhtiyacı (KOİ) 14 mg/L ve Toplam Çözünmüş Katı (TÇK) 86 mg/L olarak tespit edilmiştir. Deney sonrası elde edilen NF süzüntü suyunun yeniden kullanılabilirliği, ulusal ve uluslararası mevzuatlara göre değerlendirilmiş, pH 6.5, Biyolojik Oksijen İhtiyacı (BOİ5) 9.6 mg/L olarak bulunmuş ve süzüntü suyunda fekal koliform ile Askıda Katı Madde (AKM)’ ye rastlanmamıştır. Buradan elde edilen süzüntü suyunun sulama amaçlı kullanıma uygun olduğu, ayrıca endüstriyel soğutma suyu ve yeraltı suyuna deşarj gibi farklı amaçlar için de kullanılabileceği görülmektedir.
- 19 September 2022
- Published by Springer Nature in International Journal of Environmental Science and Technology
- Vol. 20 (5) , 5427-5440
Experience in using a pilot plant for the treatment and reuse of laundries wastewater: electroflotocoagulation and adsorption
- 19 September 2022
- Published by Springer Nature in International Journal of Environmental Science and Technology
- Vol. 20 (5) , 5427-5440
Experience in using a pilot plant for the treatment and reuse of laundries wastewater: electroflotocoagulation and adsorption
- 3 March 2021
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 103 (9) , 2107-2125
Deep purification of pretreated laundry wastewater through the adsorption by polymeric composites and optimisation of the process
In the article, the treatment of pre-treated laundry wastewater by adsorption method was studied through the experimental design. The composites of the polyaniline-supported activated carbons produced from sunflower seed hulls (PAn/SH) were used as adsorbents. Characteristics of the adsorbents were determined with the help of scanning electron microscopy, Fourier-transform infrared spectroscopy and elemental analysis. Experimental design was used to determine the effects of pH (4–12), reaction time (5–150 min), adsorbent amount (0.3–1.5 g) and mixing rate (50–200 rpm) on the process efficiency. Monitoring of the efficiency was held in terms of detergent and chemical oxygen demand removals. Response surface methodology based on the four-variable-three-level Box–Behnken design was used to interpret the adsorption properties of laundry wastewater on COD and detergent removal efficiencies. The removal efficiencies of the adsorption process were evaluated regarding to the experimental design and also Pareto analysis was applied for profiling the percentage effect of the independent variable on the response for the study. Accordingly, the most effective factors were computed as the amount of adsorbent (82%) in detergent removal and the mixing rate (31%) in COD removal, where pH was the second effective factor for both. The highest efficiencies of the MBAS and COD removals were achieved as 95% and 74% in the 24th run, respectively. In the treatment of laundry wastewater by adsorption method, using PAn/SH produced from the sunflower seed hulls as an adsorbent will be an alternative method.
- 3 March 2021
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 103 (9) , 2107-2125
Deep purification of pretreated laundry wastewater through the adsorption by polymeric composites and optimisation of the process
In the article, the treatment of pre-treated laundry wastewater by adsorption method was studied through the experimental design. The composites of the polyaniline-supported activated carbons produced from sunflower seed hulls (PAn/SH) were used as adsorbents. Characteristics of the adsorbents were determined with the help of scanning electron microscopy, Fourier-transform infrared spectroscopy and elemental analysis. Experimental design was used to determine the effects of pH (4–12), reaction time (5–150 min), adsorbent amount (0.3–1.5 g) and mixing rate (50–200 rpm) on the process efficiency. Monitoring of the efficiency was held in terms of detergent and chemical oxygen demand removals. Response surface methodology based on the four-variable-three-level Box–Behnken design was used to interpret the adsorption properties of laundry wastewater on COD and detergent removal efficiencies. The removal efficiencies of the adsorption process were evaluated regarding to the experimental design and also Pareto analysis was applied for profiling the percentage effect of the independent variable on the response for the study. Accordingly, the most effective factors were computed as the amount of adsorbent (82%) in detergent removal and the mixing rate (31%) in COD removal, where pH was the second effective factor for both. The highest efficiencies of the MBAS and COD removals were achieved as 95% and 74% in the 24th run, respectively. In the treatment of laundry wastewater by adsorption method, using PAn/SH produced from the sunflower seed hulls as an adsorbent will be an alternative method.