Alejandra Tonina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Alejandra Tonina has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Liliana Arrachea
Centro Atomico Bariloche
2 shared publications - Mariano A. Real
Instituto Nacional de Tecnologa Industrial (INTI), Buenos Aires, Argentina
2 shared publications Christian Reichl
Solid State Physics Laboratory, ETH Zürich, CH-8093 Zürich, Switzerland
1 shared publication- Christian Reichl
Laboratorium für Festkörperphysik, ETH Zürich 2 , CH-8093 Zürich
1 shared publication - Juan Herrera Mateos
Instituto de Ciencias Físicas y Escuela de Ciencia y Tecnología, Universidad Nacional de San Martín, Buenos Aires, Argentina
1 shared publication - Marcos Eduardo Bierzychudek
Instituto Nacional de Tecnología Industrial y Universidad Nacional de Moreno
1 shared publication
Latest Publications
- 6 March 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (10) , 103101
Controlled generation and detection of a thermal bias in Corbino devices under the quantum Hall regime
We present an experimental technique to generate and measure a temperature bias in the quantum Hall effect of GaAs/AlGaAs Corbino samples. The bias is generated by injecting an electric current at a central resistive heater, and the resulting radial temperature drop is determined by conductance measurements at internal and external concentric rings. The experimental results agree with the predictions of numerical simulations of the heat flow through the substrate. We also compare these results with previous predictions based on the thermoelectric response of these devices.
- 6 March 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (10) , 103101
Controlled generation and detection of a thermal bias in Corbino devices under the quantum Hall regime
We present an experimental technique to generate and measure a temperature bias in the quantum Hall effect of GaAs/AlGaAs Corbino samples. The bias is generated by injecting an electric current at a central resistive heater, and the resulting radial temperature drop is determined by conductance measurements at internal and external concentric rings. The experimental results agree with the predictions of numerical simulations of the heat flow through the substrate. We also compare these results with previous predictions based on the thermoelectric response of these devices.
- 3 March 2021
- Published by American Physical Society (APS) in Physical Review B
- Vol. 103 (12) , 125404
Thermoelectric cooling properties of a quantum Hall Corbino device
We analyze the thermoelectric cooling properties of a Corbino device in the quantum Hall regime on the basis of experimental data of electrical conductance. We focus on the cooling power and the coefficient of performance within and beyond linear response. Thermovoltage measurements in this device reported by Real et al., [ Phys. Rev. Appl. 14, 034019 (2020)] indicated that the transport takes place in the diffusive regime, without signatures of effects due to the electron-phonon interaction in a wide range of temperatures and filling factors. In this regime, the heat and charge currents by electrons can be described by a single transmission function. We infer this function from experimental data of conductance measurements and we calculate the cooling power and the coefficient of performance for a wide range of filling factors and temperatures, as functions of the thermal and electrical biases. We predict an interesting cooling performance in several parameter regimes.
- 3 March 2021
- Published by American Physical Society (APS) in Physical Review B
- Vol. 103 (12) , 125404
Thermoelectric cooling properties of a quantum Hall Corbino device
We analyze the thermoelectric cooling properties of a Corbino device in the quantum Hall regime on the basis of experimental data of electrical conductance. We focus on the cooling power and the coefficient of performance within and beyond linear response. Thermovoltage measurements in this device reported by Real et al., [ Phys. Rev. Appl. 14, 034019 (2020)] indicated that the transport takes place in the diffusive regime, without signatures of effects due to the electron-phonon interaction in a wide range of temperatures and filling factors. In this regime, the heat and charge currents by electrons can be described by a single transmission function. We infer this function from experimental data of conductance measurements and we calculate the cooling power and the coefficient of performance for a wide range of filling factors and temperatures, as functions of the thermal and electrical biases. We predict an interesting cooling performance in several parameter regimes.
- Open Access
- 6 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 64 (12) , 3451-3457
Identification and Control of a Cryogenic Current Comparator Using Robust Control Theory
This paper presents the model identification of a cryogenic current comparator (CCC). A dynamic model set is obtained and compared with the experimental data in order to provide a realistic dynamical behavior of the system. To improve the performance of the CCC, an H ∞ optimal controller is designed based on this model set. In this framework, a robust stability guarantee is provided and the simulations of the closed-loop system illustrate the performance and robustness improvements.
- 6 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 64 (12) , 3451-3457
Open AccessIdentification and Control of a Cryogenic Current Comparator Using Robust Control Theory
This paper presents the model identification of a cryogenic current comparator (CCC). A dynamic model set is obtained and compared with the experimental data in order to provide a realistic dynamical behavior of the system. To improve the performance of the CCC, an H ∞ optimal controller is designed based on this model set. In this framework, a robust stability guarantee is provided and the simulations of the closed-loop system illustrate the performance and robustness improvements.