SRStefan Röttger

Stefan Röttger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stefan Röttger has a total of 124 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Field validation of an SI‑traceable calibration transfer methodology using portable radon monitors

    by Daniel Rábago, Scott Chambers, Maksym Gachkivskyi, Roger Curcoll, Marta Fuente, Stefan Röttger, Camille Yver-Kwok, Ileana Radulescu, Arturo Vargas, Annette Röttger, et al.

  • Open Access

    Thermomechanical modelling and uncertainty reduction in cryogenic defined solid-angle alpha counting for primary Radon-222 standardisation

    by Behnam Khanbabaee, Anja Honig, Stefan Röttger

    In defined solid-angle (DSA) alpha counting for the primary standardisation of Radon-222 activity, cryogenic operation can modify the measurement geometry through thermomechanical deformation of the source assembly and changes in the potential extent of the deposited source. Coupled heat-transfer and thermomechanical finite-element simulations were used to investigate the influence of nickel support rod length on the source–diaphragm distance and on the radial region in which Radon-222 condensation is thermodynamically possible. Thermomechanical deformation was found to be the dominant contribution to the uncertainty of the source–diaphragm distance for the investigated configurations. Shortening the support rod reduced this contribution but increased the thermally affected source radius. These effects were propagated to the geometry factor using a GUM-compliant uncertainty analysis. Under the assumed uncertainties of the investigated geometrical parameters, the calculated relative combined standard uncertainty associated with the geometry factor decreases from approximately 0.16% for a 120 mm support rod to approximately 0.03% for a 5 mm rod. The results provide quantitative guidance for optimising cryogenic DSA source assemblies, while a complete uncertainty evaluation of the primary Radon-222 standardisation requires consideration of the actual spatial distribution of deposited activity and other measurement-model contributions.

  • Open Access

    Review of the Radon Tracer Method for GHG emission estimates: development, application guidelines, improvements, and caveats

    by Scott D. Chambers, Ute Karstens, Alan D. Griffiths, Stefan Röttger, Arnoud Frumau, Christopher T. Roulston, Peter Sperlich, Felix Vogel, Agnieszka Podstawczyńska, Dafina Kikaj, et al.

    The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a “standard protocol” for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.

  • Open Access

    Reply on RC2

    by Scott D. Chambers, Ute Karstens, Alan D. Griffiths, Stefan Röttger, Arnoud Frumau, Christopher T. Roulston, Peter Sperlich, Felix Vogel, Agnieszka Podstawczyńska, Dafina Kikaj, et al.

    The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a "standard protocol" for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.

  • Open Access

    Comment on egusphere-2025-5042

    by Scott D. Chambers, Ute Karstens, Alan D. Griffiths, Stefan Röttger, Arnoud Frumau, Christopher T. Roulston, Peter Sperlich, Felix Vogel, Agnieszka Podstawczyńska, Dafina Kikaj, et al.

    The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a "standard protocol" for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.

  • Open Access

    Reply on RC1

    by Scott D. Chambers, Ute Karstens, Alan D. Griffiths, Stefan Röttger, Arnoud Frumau, Christopher T. Roulston, Peter Sperlich, Felix Vogel, Agnieszka Podstawczyńska, Dafina Kikaj, et al.

    The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a "standard protocol" for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.

  • Open Access

    Comment on egusphere-2025-5042

    by Scott D. Chambers, Ute Karstens, Alan D. Griffiths, Stefan Röttger, Arnoud Frumau, Christopher T. Roulston, Peter Sperlich, Felix Vogel, Agnieszka Podstawczyńska, Dafina Kikaj, et al.

    The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a "standard protocol" for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.

  • Open Access

    Direct measurement of the 140Ce(n,γ) cross section at kT ≈ 11 keV

    by I. Goldberg, M. Pichotta, D. Bemmerer, A. Honig, B. Lutz, E. Pirovano, S. Röttger, M. Friedman

  • Open Access

    Evaluating geometrical parameters in defined solid-angle alpha spectrometry for absolute Radon-222 activity measurement

    by B. Khanbabaee, Anja Honig, Stefan Röttger

    Defined Solid Angle (DSA) alpha spectrometry is a primary method for absolute activity determination of Radon-222, in which radon is cryogenically depositing onto a polished cold disk under vacuum and counted in a fixed source–detector geometry. In this approach, the detection efficiency is determined exclusively by the normalized solid angle, expressed as the Geometry Factor $$G$$ G . The accuracy of activity determination therefore depends directly on the precise evaluation of $$G$$ G and its associated uncertainty. This work presents a comprehensive numerical investigation of the sensitivity and uncertainty of $$G$$ G with respect to the governing geometrical parameters: source–diaphragm distance $$z$$ z , diaphragm radius $$a$$ a , source radius $$b$$ b , and eccentricity $$e$$ e . Calculations were performed using both the Knoll (Radiation detection and measurement, 4th ed. Wiley, New York, S120, 2010) and Curtis (Nucleus 13:38, 1955. https://doi.org/10.1016/S0168-9002(96)80029-5 ) analytical extensions, enabling systematic parameter variation and direct model comparison. The results show excellent agreement between the two models for concentric configurations ( $$e$$ e = 0 mm). The Geometry Factor is found to be most sensitive to variations in $$z$$ z and $$a$$ a ; however, uncertainty propagation analysis demonstrates that the dominant contribution to the combined uncertainty arises from $$z$$ z , accounting for approximately 88% – 97% of the total variance under typical National Metrology Institute (NMI) conditions. In contrast, the influence of $$b$$ b is significantly smaller, and eccentricities up to 1 mm produce only minor variations in $$G$$ G . These findings quantitatively identify the source–diaphragm distance as the critical parameter limiting uncertainty reduction in DSA-based primary standardization of Radon-222. The study provides a clear metrological framework for optimizing geometry control and supports the harmonization of high-accuracy activity measurements across NMIs, enabling more stable and reliable transfer standards for secondary laboratories and end-users.


  • Open Access

    Traceable in-situ calibration of low activity concentration radon detectors

    by Stefan Röttger, Florian Mertes, Scott Chambers, Alan Griffiths, Roger Curcoll, Arturo Vargas, José Luis Gutiérrez Villanueva, Annette Röttger