Nazım İmal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nazım İmal has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Burak Öztürk
Bilecik Şeyh Edebali Üniversitesi
3 shared publications - Anwr Abd S. Elasyri
Department of Electrical and Electronics Engineering, Faculty of Engineering, Block C, 3rd Floor, Gülümbe Campus, Bilecik Seyh Edebali University, 11210 Bilecik, Turkey
2 shared publications - Mehmet Fidan
Eskisehir Technical University
2 shared publications Emir Sadık Arın
Bilecik University Department of Metallurgical and Materials Engineering
1 shared publication- John David Fleig
Franklin University, OH, USA
1 shared publication - Mehmet Cemil Kale
Eskisehir Osmangazi Univ, Eskisehir Vocat Sch, Eskisehir, Turkey
1 shared publication
Latest Publications
- Open Access
A Comprehensive Database and Smart-Learning Framework for Monitoring Failure Risk Factors, Maintenance, and Protection in Electrical Networks
Electrical power systems are exposed to interacting electrical, thermal, environmental, and resource-related faults such as leakage current, voltage and frequency deviations, overcurrent, harmonic distortion, phase-sequence error, humidity, fire, wind-speed variability, water insufficiency, and solar-resource loss. This study introduces a software-based database-generation and smart-learning framework that converts 22 candidate risk factors into six normalized severity levels and then maps the simultaneous system state to low-, medium-, and high-level protection decisions. The main novelty is that the software not only evaluates existing measurements; it also produces a literature- and standards-informed synthetic database when long-term real field measurements are not yet available. The database is generated by defining variable limits, sampling realistic operating states, computing severity labels, and storing input–output pairs that can later train or validate predictive maintenance models. The proposed framework therefore, links protection logic, database construction, and reusable training data in a single workflow. The results show how simulated annual operating scenarios can be transformed into structured risk records, warning classes, and shutdown decisions, supporting early fault detection, maintenance planning, and resilience improvement in renewable-integrated electrical networks.
Open AccessA Comprehensive Database and Smart-Learning Framework for Monitoring Failure Risk Factors, Maintenance, and Protection in Electrical Networks
Electrical power systems are exposed to interacting electrical, thermal, environmental, and resource-related faults such as leakage current, voltage and frequency deviations, overcurrent, harmonic distortion, phase-sequence error, humidity, fire, wind-speed variability, water insufficiency, and solar-resource loss. This study introduces a software-based database-generation and smart-learning framework that converts 22 candidate risk factors into six normalized severity levels and then maps the simultaneous system state to low-, medium-, and high-level protection decisions. The main novelty is that the software not only evaluates existing measurements; it also produces a literature- and standards-informed synthetic database when long-term real field measurements are not yet available. The database is generated by defining variable limits, sampling realistic operating states, computing severity labels, and storing input–output pairs that can later train or validate predictive maintenance models. The proposed framework therefore, links protection logic, database construction, and reusable training data in a single workflow. The results show how simulated annual operating scenarios can be transformed into structured risk records, warning classes, and shutdown decisions, supporting early fault detection, maintenance planning, and resilience improvement in renewable-integrated electrical networks.
- Open Access
- 5 June 2026
- Published by MDPI AG in Preprints.org
A Comprehensive Database and Smart-Learning Framework for Monitoring Failure Risk Factors, Maintenance, and Protection in Electrical Networks
Electrical power systems are exposed to interacting electrical, thermal, environmental, and resource-related faults such as leakage current, voltage and frequency deviations, overcurrent, harmonic distortion, phase-sequence error, humidity, fire, wind-speed variability, water insufficiency, and solar-resource loss. This study introduces a software-based database-generation and smart-learning framework that converts 22 candidate risk factors into six normalized severity levels and then maps the simultaneous system state to low-, medium-, and high-level protection decisions. The main novelty is that the software does not only evaluate existing measurements; it also produces a literature- and standards-informed synthetic database when long-term real field measurements are not yet available. The database is generated by defining variable limits, sampling realistic operating states, computing severity labels, and storing input-output pairs that can later train or validate predictive maintenance models. The proposed framework therefore links protection logic, database construction, and reusable training data in a single workflow. The results show how simulated annual operating scenarios can be transformed into structured risk records, warning classes, and shutdown decisions, supporting early fault detection, maintenance planning, and resilience improvement in renewable-integrated electrical networks.
- 5 June 2026
- Published by MDPI AG in Preprints.org
Open AccessA Comprehensive Database and Smart-Learning Framework for Monitoring Failure Risk Factors, Maintenance, and Protection in Electrical Networks
Electrical power systems are exposed to interacting electrical, thermal, environmental, and resource-related faults such as leakage current, voltage and frequency deviations, overcurrent, harmonic distortion, phase-sequence error, humidity, fire, wind-speed variability, water insufficiency, and solar-resource loss. This study introduces a software-based database-generation and smart-learning framework that converts 22 candidate risk factors into six normalized severity levels and then maps the simultaneous system state to low-, medium-, and high-level protection decisions. The main novelty is that the software does not only evaluate existing measurements; it also produces a literature- and standards-informed synthetic database when long-term real field measurements are not yet available. The database is generated by defining variable limits, sampling realistic operating states, computing severity labels, and storing input-output pairs that can later train or validate predictive maintenance models. The proposed framework therefore links protection logic, database construction, and reusable training data in a single workflow. The results show how simulated annual operating scenarios can be transformed into structured risk records, warning classes, and shutdown decisions, supporting early fault detection, maintenance planning, and resilience improvement in renewable-integrated electrical networks.
- Open Access
SLEC-Based Tunnel Lighting Design: A Sustainable Engineering Approach Through RSM
Tunnel lighting systems serving pedestrian and vehicular traffic must simultaneously satisfy visual performance requirements and energy efficiency constraints. This study investigates the optimization of tunnel lighting design using a sustainable engineering approach based on Response Surface Methodology (RSM) and Specific Lighting Energy Consumption (SLEC). Software-assisted lighting simulations were performed for two tunnel geometries—straight and double-curved—and horizontal (Eh) and vertical (Ev) illuminance levels were evaluated at five representative locations. The resulting data were used to construct RSM-based predictive models and to assess energy performance through SLEC. The effects of mounting height, luminaire spacing, luminous flux, number of luminaires, and tunnel type were systematically analyzed. The results demonstrate that luminaire spacing is the dominant parameter influencing illuminance levels and energy consumption. An optimal configuration consisting of a 12 m luminaire spacing, 5 m mounting height, and 10,000–12,000 lm luminous flux achieved a favorable balance between lighting quality and energy efficiency. Additionally, straight tunnels exhibited higher illuminance uniformity at shorter spacings, whereas curved tunnels showed improved performance under wider spacing conditions. The proposed RSM–SLEC framework provides a robust, data-driven methodology for sustainable tunnel lighting design without compromising safety or visual comfort.
Open AccessSLEC-Based Tunnel Lighting Design: A Sustainable Engineering Approach Through RSM
Tunnel lighting systems serving pedestrian and vehicular traffic must simultaneously satisfy visual performance requirements and energy efficiency constraints. This study investigates the optimization of tunnel lighting design using a sustainable engineering approach based on Response Surface Methodology (RSM) and Specific Lighting Energy Consumption (SLEC). Software-assisted lighting simulations were performed for two tunnel geometries—straight and double-curved—and horizontal (Eh) and vertical (Ev) illuminance levels were evaluated at five representative locations. The resulting data were used to construct RSM-based predictive models and to assess energy performance through SLEC. The effects of mounting height, luminaire spacing, luminous flux, number of luminaires, and tunnel type were systematically analyzed. The results demonstrate that luminaire spacing is the dominant parameter influencing illuminance levels and energy consumption. An optimal configuration consisting of a 12 m luminaire spacing, 5 m mounting height, and 10,000–12,000 lm luminous flux achieved a favorable balance between lighting quality and energy efficiency. Additionally, straight tunnels exhibited higher illuminance uniformity at shorter spacings, whereas curved tunnels showed improved performance under wider spacing conditions. The proposed RSM–SLEC framework provides a robust, data-driven methodology for sustainable tunnel lighting design without compromising safety or visual comfort.
- 23 February 2026
- Published by Emerald Publishing in Multidiscipline Modeling in Materials and Structures
- Vol. 22 (4) , 895-917
RSM-based optimization and SLEC evaluation of a high-frequency PWM LED driver circuit for disaster-relief lighting drones
Purpose: This study investigates the optimization of (Unmanned Aerial Vehicle) UAV-based illumination systems using experimental design, Dialux simulations, and image processing methods, with a focus on maximizing lighting performance while minimizing energy consumption. Design/methodology/approach: A full factorial experimental design with four factors (circuit status, spot angle, height, and spot efficiency) at multiple levels was employed. Dialux software was used to calculate horizontal and vertical illuminance values and homogeneity indices, while Python-based image processing (OpenCV and polynomial regression) extracted detailed illumination profiles. Response Surface Methodology (RSM) was applied in Minitab to evaluate factor significance and to determine the optimal parameter set. Findings: The results showed that spot efficiency was the most dominant factor (p < 0.001) across all responses, while height significantly influenced horizontal average illuminance (p = 0.000). The maximum horizontal illuminance (Eyavg) of 7.10 lux was achieved at 10 m with narrow beam efficiency, whereas the minimum specific lighting energy consumption - Ey (SLEC Ey) was 0.010 W/lux under the same conditions. RSM optimization yielded a composite desirability of 1.000, indicating perfect agreement with the target objectives. Model reliability was confirmed with high coefficients of determination (R2 = 86–99%). Originality/value: This study introduces a novel optimization framework for UAV-based illumination systems by integrating experimental lighting performance data with RSM. Unlike previous research that mainly focused on communication or surveillance aspects of drones, our work emphasizes quantitative analysis of lighting efficiency and energy consumption under varying operational factors. The combination of ANOVA modeling, surface plots, and desirability functions provides statistically robust results and identifies the optimum operational parameters with high accuracy.
- 23 February 2026
- Published by Emerald Publishing in Multidiscipline Modeling in Materials and Structures
- Vol. 22 (4) , 895-917
RSM-based optimization and SLEC evaluation of a high-frequency PWM LED driver circuit for disaster-relief lighting drones
Purpose: This study investigates the optimization of (Unmanned Aerial Vehicle) UAV-based illumination systems using experimental design, Dialux simulations, and image processing methods, with a focus on maximizing lighting performance while minimizing energy consumption. Design/methodology/approach: A full factorial experimental design with four factors (circuit status, spot angle, height, and spot efficiency) at multiple levels was employed. Dialux software was used to calculate horizontal and vertical illuminance values and homogeneity indices, while Python-based image processing (OpenCV and polynomial regression) extracted detailed illumination profiles. Response Surface Methodology (RSM) was applied in Minitab to evaluate factor significance and to determine the optimal parameter set. Findings: The results showed that spot efficiency was the most dominant factor (p < 0.001) across all responses, while height significantly influenced horizontal average illuminance (p = 0.000). The maximum horizontal illuminance (Eyavg) of 7.10 lux was achieved at 10 m with narrow beam efficiency, whereas the minimum specific lighting energy consumption - Ey (SLEC Ey) was 0.010 W/lux under the same conditions. RSM optimization yielded a composite desirability of 1.000, indicating perfect agreement with the target objectives. Model reliability was confirmed with high coefficients of determination (R2 = 86–99%). Originality/value: This study introduces a novel optimization framework for UAV-based illumination systems by integrating experimental lighting performance data with RSM. Unlike previous research that mainly focused on communication or surveillance aspects of drones, our work emphasizes quantitative analysis of lighting efficiency and energy consumption under varying operational factors. The combination of ANOVA modeling, surface plots, and desirability functions provides statistically robust results and identifies the optimum operational parameters with high accuracy.
- 21 November 2025
- Published by Emerald Publishing in Engineering Computations
- Vol. 43 (2) , 609-635
Multi-objective optimization of special lighting energy consumption (SLEC) for stadiums
Purpose: This study aims to optimize stadium lighting energy consumption while ensuring maximum visual quality. Stadium lighting is essential for athletes’ performance, audience experience and broadcast quality. However, illuminating large areas incurs high energy costs. The main motivation is to develop a multi-objective optimization approach that enhances energy efficiency and lighting performance simultaneously. Design/methodology/approach: A custom MATLAB-based optimization model was developed to analyze stadium lighting performance. Experiments were conducted to evaluate the impact of pole height, field distance (X and Y axes) and fixture count on lighting efficiency. A multi-objective optimization framework was designed using response surface methodology (RSM), with 18 experimental runs performed. Findings: The optimal lighting setup was achieved in the fourth experiment, yielding 1,213 Lux (horizontal) and 1724 Lux (vertical) illumination. The validation experiment confirmed improvements, reaching 1,350 Lux (horizontal) and 1825 Lux (vertical), differing from RSM-based experiments. These results were obtained with energy consumption of 277 W/Lux (horizontal) and 205 W/Lux (vertical). The proposed optimization method resulted in a 32% improvement in energy efficiency and a 42% enhancement in lighting performance. The accuracy of the model was validated through real-field testing, achieving 89.1%–94.5% agreement with experimental results. Originality/value: This study presents a novel optimization approach for stadium lighting, contributing to energy savings, uniform illumination and lighting performance enhancement. For the first time in the literature, the energy required per unit lux (W/Lux) was systematically defined and analyzed using the special lighting energy consumption (SLEC) metric.
- 21 November 2025
- Published by Emerald Publishing in Engineering Computations
- Vol. 43 (2) , 609-635
Multi-objective optimization of special lighting energy consumption (SLEC) for stadiums
Purpose: This study aims to optimize stadium lighting energy consumption while ensuring maximum visual quality. Stadium lighting is essential for athletes’ performance, audience experience and broadcast quality. However, illuminating large areas incurs high energy costs. The main motivation is to develop a multi-objective optimization approach that enhances energy efficiency and lighting performance simultaneously. Design/methodology/approach: A custom MATLAB-based optimization model was developed to analyze stadium lighting performance. Experiments were conducted to evaluate the impact of pole height, field distance (X and Y axes) and fixture count on lighting efficiency. A multi-objective optimization framework was designed using response surface methodology (RSM), with 18 experimental runs performed. Findings: The optimal lighting setup was achieved in the fourth experiment, yielding 1,213 Lux (horizontal) and 1724 Lux (vertical) illumination. The validation experiment confirmed improvements, reaching 1,350 Lux (horizontal) and 1825 Lux (vertical), differing from RSM-based experiments. These results were obtained with energy consumption of 277 W/Lux (horizontal) and 205 W/Lux (vertical). The proposed optimization method resulted in a 32% improvement in energy efficiency and a 42% enhancement in lighting performance. The accuracy of the model was validated through real-field testing, achieving 89.1%–94.5% agreement with experimental results. Originality/value: This study presents a novel optimization approach for stadium lighting, contributing to energy savings, uniform illumination and lighting performance enhancement. For the first time in the literature, the energy required per unit lux (W/Lux) was systematically defined and analyzed using the special lighting energy consumption (SLEC) metric.
- 23 March 2020
- Published by Bilecik Seyh Edebali Universitesi Fen Bilimleri Dergisi in Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi
- Vol. 7 (100. Yıl Ö) , 353-362
Su Şebeke Otomasyon Sistemi ve Uygulaması
Suyu kaynağından alarak insanların kullanımına sunmak geçmişten günümüze, birçok farklı uygulamalar ile gerçekleştirilmiştir. Makine ve elektrik sistemlerinin geliştirilmesi, öncesine nazaran insanlara çok daha temiz ve bol su temin eden su şebekelerini mümkün kılmıştır. Elektrik ve otomatik su kontrol sistemleri, kapalı devre su sistemlerinin kullanılmaya başladığı birkaç yüzyıl öncesinden bu yana kullanılmaktadır. Otomatik su sistemleri geçmişte sadece vana ve şamandıralı olarak gerçekleşirken gelişen teknoloji ile birlikte basınç şalterleri ve sensör teknolojili olarak tasarlanmaya başlamıştır. Su otomasyonunda kullanılan sensörler ışıklı ve ultrasonik sensörler olabileceği gibi elektriksel sızıntı akımlarının kullanıldığı seviye algılayıcıları da olabilir. Burada gerçekleştirilen çalışmada; kuyu, depo ve hidrofor tankına ait üçlü model üzerinde elektrot algılayıcılar kullanılarak, su şebeke otomasyonu gerçekleştirilmiştir. Gerçekleştirilen otomasyonda, çıktı olarak abonelere verilen suyun kesintisizliği öncelikle dikkate alınmakla beraber, suyun sağlanmasında oluşabilecek yetersizlikler de belirleyici etken olmaktadır. Tasarlanan sistemin, kuyu, depo ve tank olarak üçlü kombinasyon ile gerçekleştirilmesi, abonelere iletilen suyun kaynağından son çıkış noktasına kadar kontrollü akışını mümkün kılmaktadır. Su yetersizliği durumunda direkt su akışlarının kesilmesi öncesi, uyarı sisteminin de mevut olması sistemin ekstra avantajını oluşturmaktadır.
- 23 March 2020
- Published by Bilecik Seyh Edebali Universitesi Fen Bilimleri Dergisi in Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi
- Vol. 7 (100. Yıl Ö) , 353-362
Su Şebeke Otomasyon Sistemi ve Uygulaması
Suyu kaynağından alarak insanların kullanımına sunmak geçmişten günümüze, birçok farklı uygulamalar ile gerçekleştirilmiştir. Makine ve elektrik sistemlerinin geliştirilmesi, öncesine nazaran insanlara çok daha temiz ve bol su temin eden su şebekelerini mümkün kılmıştır. Elektrik ve otomatik su kontrol sistemleri, kapalı devre su sistemlerinin kullanılmaya başladığı birkaç yüzyıl öncesinden bu yana kullanılmaktadır. Otomatik su sistemleri geçmişte sadece vana ve şamandıralı olarak gerçekleşirken gelişen teknoloji ile birlikte basınç şalterleri ve sensör teknolojili olarak tasarlanmaya başlamıştır. Su otomasyonunda kullanılan sensörler ışıklı ve ultrasonik sensörler olabileceği gibi elektriksel sızıntı akımlarının kullanıldığı seviye algılayıcıları da olabilir. Burada gerçekleştirilen çalışmada; kuyu, depo ve hidrofor tankına ait üçlü model üzerinde elektrot algılayıcılar kullanılarak, su şebeke otomasyonu gerçekleştirilmiştir. Gerçekleştirilen otomasyonda, çıktı olarak abonelere verilen suyun kesintisizliği öncelikle dikkate alınmakla beraber, suyun sağlanmasında oluşabilecek yetersizlikler de belirleyici etken olmaktadır. Tasarlanan sistemin, kuyu, depo ve tank olarak üçlü kombinasyon ile gerçekleştirilmesi, abonelere iletilen suyun kaynağından son çıkış noktasına kadar kontrollü akışını mümkün kılmaktadır. Su yetersizliği durumunda direkt su akışlarının kesilmesi öncesi, uyarı sisteminin de mevut olması sistemin ekstra avantajını oluşturmaktadır.
- Open Access
- 9 April 2013
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2013, 1-6
Assessment of Feasibility to Use Computer Aided Texture Analysis Based Tool for Parametric Images of Suspicious Lesions in DCE-MR Mammography
Our aim was to analyze the feasibility of computer aided malignant tumor detection using the traditional texture analysis applied on two-compartment-based parameter pseudoimages of dynamic contrast-enhanced magnetic resonance (DCE-MR) breast image data. A major contribution of this research will be the through-plane assessment capability. Texture analysis was performed on two-compartment-based pseudo images of DCE-MRI datasets of breast data of eight subjects. The resulting texture parameter pseudo images were inputted to a feedforward neural network classification system which uses the manual segmentations of a primary radiologist as a gold standard, and each voxel was assigned as malignant or nonmalignant. The classification results were compared with the lesions manually segmented by a second radiologist. Results show that the mean true positive fraction (TPF) and false positive fraction (FPF) performance of the classifier vs. primary radiologist is statistically as good as the mean TPF and FPF performance of the second radiologist vs. primary radiologist with a confidence interval of 95% using a one-sample -test with . In the experiment implemented on all of the eight subjects, all malignant tumors marked by the primary radiologist were classified to be malignant by the computer classifier. Our results have shown that neural network classification using the textural parameters for automated screening of two-compartment-based parameter pseudo images of DCE-MRI as input data can be a supportive tool for the radiologists in the preassessment stage to show the possible cancerous regions and in the postassessment stage to review the segmentations especially in analyzing complex DCE-MRI cases.
- 9 April 2013
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2013, 1-6
Open AccessAssessment of Feasibility to Use Computer Aided Texture Analysis Based Tool for Parametric Images of Suspicious Lesions in DCE-MR Mammography
Our aim was to analyze the feasibility of computer aided malignant tumor detection using the traditional texture analysis applied on two-compartment-based parameter pseudoimages of dynamic contrast-enhanced magnetic resonance (DCE-MR) breast image data. A major contribution of this research will be the through-plane assessment capability. Texture analysis was performed on two-compartment-based pseudo images of DCE-MRI datasets of breast data of eight subjects. The resulting texture parameter pseudo images were inputted to a feedforward neural network classification system which uses the manual segmentations of a primary radiologist as a gold standard, and each voxel was assigned as malignant or nonmalignant. The classification results were compared with the lesions manually segmented by a second radiologist. Results show that the mean true positive fraction (TPF) and false positive fraction (FPF) performance of the classifier vs. primary radiologist is statistically as good as the mean TPF and FPF performance of the second radiologist vs. primary radiologist with a confidence interval of 95% using a one-sample -test with . In the experiment implemented on all of the eight subjects, all malignant tumors marked by the primary radiologist were classified to be malignant by the computer classifier. Our results have shown that neural network classification using the textural parameters for automated screening of two-compartment-based parameter pseudo images of DCE-MRI as input data can be a supportive tool for the radiologists in the preassessment stage to show the possible cancerous regions and in the postassessment stage to review the segmentations especially in analyzing complex DCE-MRI cases.