Nora Mettig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nora Mettig has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Alexei Rozanov
Institute of Environmental Physics, University of Bremen, Bremen, Germany
6 shared publications - Mark Weber
Institute of Environmental Physics, University of Bremen, Bremen, Germany
6 shared publications - Anne Mee Thompson
Earth Sciences Division, NASA Goddard Space Flight Center, Greenbelt, Maryland, USA
5 shared publications - John Phillip Burrows
Institute of Environmental Physics, University of Bremen, Bremen, Germany
5 shared publications - Matthew Brian Tully
Bureau of Meteorology, Melbourne, Australia
5 shared publications - Pepijn Veefkind
Royal Netherlands Meteorological Institute (KNMI), De Bilt, 3731 GA, the Netherlands
5 shared publications
Latest Publications
- Open Access
- 1 September 2022
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 22 (17) , 11137-11153
Tropospheric and stratospheric ozone profiles during the 2019 TROpomi vaLIdation eXperiment (TROLIX-19)
A TROPOspheric Monitoring Instrument (TROPOMI) validation campaign was held in the Netherlands based at the CESAR (Cabauw Experimental Site for Atmospheric Research) observatory during September 2019. The TROpomi vaLIdation eXperiment (TROLIX-19) consisted of active and passive remote sensing platforms in conjunction with several balloon-borne and surface chemical (e.g., ozone and nitrogen dioxide) measurements. The goal of this joint NASA-KNMI geophysical validation campaign was to make intensive observations in the TROPOMI domain in order to be able to establish the quality of the L2 satellite data products under realistic conditions, such as non-idealized conditions with varying cloud cover and a range of atmospheric conditions at a rural site. The research presented here focuses on using ozone lidars from NASA's Goddard Space Flight Center to better evaluate the characterization of ozone throughout TROLIX-19. Results of comparisons to the lidar systems with balloon, space-borne and ground-based passive measurements are shown. In addition, results are compared to a global coupled chemistry meteorology model to illustrate the vertical variability and columnar amounts of both tropospheric and stratospheric ozone during the campaign period.
- 1 September 2022
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 22 (17) , 11137-11153
Open AccessTropospheric and stratospheric ozone profiles during the 2019 TROpomi vaLIdation eXperiment (TROLIX-19)
A TROPOspheric Monitoring Instrument (TROPOMI) validation campaign was held in the Netherlands based at the CESAR (Cabauw Experimental Site for Atmospheric Research) observatory during September 2019. The TROpomi vaLIdation eXperiment (TROLIX-19) consisted of active and passive remote sensing platforms in conjunction with several balloon-borne and surface chemical (e.g., ozone and nitrogen dioxide) measurements. The goal of this joint NASA-KNMI geophysical validation campaign was to make intensive observations in the TROPOMI domain in order to be able to establish the quality of the L2 satellite data products under realistic conditions, such as non-idealized conditions with varying cloud cover and a range of atmospheric conditions at a rural site. The research presented here focuses on using ozone lidars from NASA's Goddard Space Flight Center to better evaluate the characterization of ozone throughout TROLIX-19. Results of comparisons to the lidar systems with balloon, space-borne and ground-based passive measurements are shown. In addition, results are compared to a global coupled chemistry meteorology model to illustrate the vertical variability and columnar amounts of both tropospheric and stratospheric ozone during the campaign period.
- Open Access
- 12 May 2022
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 15 (9) , 2955-2978
Combined UV and IR ozone profile retrieval from TROPOMI and CrIS measurements
Vertical ozone profiles from combined spectral measurements in the ultraviolet and infrared spectral range were retrieved by using data from the TROPOspheric Monitoring Instrument on the Sentinel-5 Precursor (TROPOMI/S5P) and the Cross-track Infrared Sounder on the Suomi National Polar-orbiting Partnership (CrIS/Suomi-NPP), which are flying in loose formation 3 min apart in the same orbit. A previous study of ozone profiles retrieved exclusively from TROPOMI UV spectra showed that the vertical resolution in the troposphere is clearly limited (Mettig et al., 2021). The vertical resolution and the vertical extent of the ozone profiles is improved by combining both wavelength ranges compared to retrievals limited to UV or IR spectral data only. The combined retrieval particularly improves the accuracy of the retrieved tropospheric ozone and to a lesser degree stratospheric ozone up to 30 km. An increase in the degrees of freedom (DOF) by 1 DOF was found in the UV + IR retrieval compared to the UV-only retrieval. Compared to previous publications, which investigated combinations of UV and IR observations from the Ozone Monitoring Instrument and Tropospheric Emission Spectrometer (OMI and TES) and Global Ozone Monitoring Experiment version 2 and Infrared Atmospheric Sounding Interferometer (GOME-2 and IASI) pairs, the degree of freedom is lower, which is attributed to the reduced spectral resolution of CrIS compared to TES or IASI. Tropospheric lidar and ozonesondes were used to validate the ozone profiles and tropospheric ozone content (TOC). In their comparison with tropospheric lidars, both ozone profiles and TOCs show smaller biases for the retrieved data from the combined UV + IR observation than from the UV observations alone. For the ozone profiles below 10 km, the mean differences are around ±10 % and the mean TOC varies around ±3 DU. We show that TOCs from the combined retrieval agree better with ozonesonde results at northern latitudes than the UV-only and IR-only retrievals and also have lower scatter. In the tropics, the IR-only retrieval shows the best agrement with TOCs derived from ozonesondes. While in general the TOCs show good agreement with ozonesonde data, the profiles have a positive bias of around 30 % between 10 and 15 km. The reason is probably a positive stratospheric bias from the IR retrieval. The comparison of the UV + IR and UV ozone profiles up to 30 km with the Microwave Limb Sounder (MLS) demonstrates the improvement of the UV + IR profile in the stratosphere above 18 km. In comparison to the UV-only approach the retrieval shows improvements of up to 10 % depending on latitude but can also show worse results in some regions and latitudes.
- 12 May 2022
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 15 (9) , 2955-2978
Open AccessCombined UV and IR ozone profile retrieval from TROPOMI and CrIS measurements
Vertical ozone profiles from combined spectral measurements in the ultraviolet and infrared spectral range were retrieved by using data from the TROPOspheric Monitoring Instrument on the Sentinel-5 Precursor (TROPOMI/S5P) and the Cross-track Infrared Sounder on the Suomi National Polar-orbiting Partnership (CrIS/Suomi-NPP), which are flying in loose formation 3 min apart in the same orbit. A previous study of ozone profiles retrieved exclusively from TROPOMI UV spectra showed that the vertical resolution in the troposphere is clearly limited (Mettig et al., 2021). The vertical resolution and the vertical extent of the ozone profiles is improved by combining both wavelength ranges compared to retrievals limited to UV or IR spectral data only. The combined retrieval particularly improves the accuracy of the retrieved tropospheric ozone and to a lesser degree stratospheric ozone up to 30 km. An increase in the degrees of freedom (DOF) by 1 DOF was found in the UV + IR retrieval compared to the UV-only retrieval. Compared to previous publications, which investigated combinations of UV and IR observations from the Ozone Monitoring Instrument and Tropospheric Emission Spectrometer (OMI and TES) and Global Ozone Monitoring Experiment version 2 and Infrared Atmospheric Sounding Interferometer (GOME-2 and IASI) pairs, the degree of freedom is lower, which is attributed to the reduced spectral resolution of CrIS compared to TES or IASI. Tropospheric lidar and ozonesondes were used to validate the ozone profiles and tropospheric ozone content (TOC). In their comparison with tropospheric lidars, both ozone profiles and TOCs show smaller biases for the retrieved data from the combined UV + IR observation than from the UV observations alone. For the ozone profiles below 10 km, the mean differences are around ±10 % and the mean TOC varies around ±3 DU. We show that TOCs from the combined retrieval agree better with ozonesonde results at northern latitudes than the UV-only and IR-only retrievals and also have lower scatter. In the tropics, the IR-only retrieval shows the best agrement with TOCs derived from ozonesondes. While in general the TOCs show good agreement with ozonesonde data, the profiles have a positive bias of around 30 % between 10 and 15 km. The reason is probably a positive stratospheric bias from the IR retrieval. The comparison of the UV + IR and UV ozone profiles up to 30 km with the Microwave Limb Sounder (MLS) demonstrates the improvement of the UV + IR profile in the stratosphere above 18 km. In comparison to the UV-only approach the retrieval shows improvements of up to 10 % depending on latitude but can also show worse results in some regions and latitudes.
- Open Access
- 13 December 2021
- Published by Copernicus GmbH in EGUsphere
- Vol. 2021, 1-33
Combined UV and IR ozone profile retrieval from TROPOMI and CrIS measurements
Vertical ozone profiles from combined spectral measurements in the ultraviolet and infrared spectral range were retrieved by using data from TROPOMI/S5P and CrIS/Suomi-NPP, which are flying in loose formation three minutes apart in the same orbit. A previous study of ozone profiles retrieved exclusively from TROPOMI UV spectra showed that the vertical resolution in the troposphere is clearly limited (Mettig et al, 2021). The vertical resolution and the vertical extent of the ozone profiles is improved by combining both wavelength ranges compared to retrievals limited to UV or IR spectral data only. The combined retrieval particularly improves the accuracy of the retrieved tropospheric ozone and to a lesser degree stratospheric ozone up to 30 km. An increase in the degree-of-freedom by one was found in the UV+IR retrieval compared to the UV-only retrieval. Compared to previous publications, which investigated combinations of UV and IR observations from the pairs OMI/TES and GOME-2/IASI, the degree of freedom is lower, which is attributed to the reduced spectral resolution of CrIS compared to TES or IASI. Tropospheric lidar and ozonesondes were used to validate the ozone profiles and tropospheric ozone column (TOC). From the comparison with tropospheric lidars both ozone profiles and TOCs show smaller biases for the retrieved data from the combined UV+IR observation than the UV observations alone. While the TOCs show good agreement, the profiles have a positive bias of more than 20 % between 10 and 15 km. The reason is probably a positive stratospheric bias from the IR retrieval. The comparison of the UV+IR and UV ozone profiles up to 30 km with MLS (Microwave Limb Sounder) demonstrates the improvement of the UV+IR profile in the stratosphere.
- 13 December 2021
- Published by Copernicus GmbH in EGUsphere
- Vol. 2021, 1-33
Open AccessCombined UV and IR ozone profile retrieval from TROPOMI and CrIS measurements
Vertical ozone profiles from combined spectral measurements in the ultraviolet and infrared spectral range were retrieved by using data from TROPOMI/S5P and CrIS/Suomi-NPP, which are flying in loose formation three minutes apart in the same orbit. A previous study of ozone profiles retrieved exclusively from TROPOMI UV spectra showed that the vertical resolution in the troposphere is clearly limited (Mettig et al, 2021). The vertical resolution and the vertical extent of the ozone profiles is improved by combining both wavelength ranges compared to retrievals limited to UV or IR spectral data only. The combined retrieval particularly improves the accuracy of the retrieved tropospheric ozone and to a lesser degree stratospheric ozone up to 30 km. An increase in the degree-of-freedom by one was found in the UV+IR retrieval compared to the UV-only retrieval. Compared to previous publications, which investigated combinations of UV and IR observations from the pairs OMI/TES and GOME-2/IASI, the degree of freedom is lower, which is attributed to the reduced spectral resolution of CrIS compared to TES or IASI. Tropospheric lidar and ozonesondes were used to validate the ozone profiles and tropospheric ozone column (TOC). From the comparison with tropospheric lidars both ozone profiles and TOCs show smaller biases for the retrieved data from the combined UV+IR observation than the UV observations alone. While the TOCs show good agreement, the profiles have a positive bias of more than 20 % between 10 and 15 km. The reason is probably a positive stratospheric bias from the IR retrieval. The comparison of the UV+IR and UV ozone profiles up to 30 km with MLS (Microwave Limb Sounder) demonstrates the improvement of the UV+IR profile in the stratosphere.
- Open Access
- 16 September 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (9) , 6057-6082
Ozone profile retrieval from nadir TROPOMI measurements in the UV range
The TOPAS (Tikhonov regularised Ozone Profile retrievAl with SCIATRAN) algorithm to retrieve vertical profiles of ozone from space-borne observations in nadir-viewing geometry has been developed at the Institute of Environmental Physics (IUP) of the University of Bremen and applied to the TROPOspheric Monitoring Instrument (TROPOMI) L1B spectral data version 2. Spectral data between 270 and 329 nm are used for the retrieval. A recalibration of the measured radiances is done using ozone profiles from MLS/Aura. Studies with synthetic spectra show that individual profiles in the stratosphere can be retrieved with an uncertainty of about 10 %. In the troposphere, the retrieval errors are larger depending on the a priori profile used. The vertical resolution above 18 km is about 6–10 km, and it degrades to 15–25 km below. The vertical resolution in the troposphere is strongly dependent on the solar zenith angle (SZA). The ozone profiles retrieved from TROPOMI with the TOPAS algorithm were validated using data from ozonesondes and stratospheric ozone lidars. Above 18 km, the comparison with sondes shows excellent agreement within less than ±5 % for all latitudes. The standard deviation of mean differences is about 10 %. Below 18 km, the relative mean deviation in the tropics and northern latitudes is still quite good, remaining within ±20 %. At southern latitudes, larger differences of up to +40 % occur between 10 and 15 km. The standard deviation is about 50 % between 7–18 km and about 25 % below 7 km. The validation of stratospheric ozone profiles with ground-based lidar measurements also shows very good agreement. The relative mean deviation is below ±5 % between 18–45 km, with a standard deviation of 10 %. TOPAS retrieval results for 1 d of TROPOMI observations were compared to ozone profiles from the Microwave Limb Sounder (MLS) on the Aura satellite and the Ozone Mapping and Profiler Suite Limb Profiler (OMPS-LP). The relative mean difference was found to be largely below ±5 % between 20–50 km, except at very high latitudes.
- 16 September 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (9) , 6057-6082
Open AccessOzone profile retrieval from nadir TROPOMI measurements in the UV range
The TOPAS (Tikhonov regularised Ozone Profile retrievAl with SCIATRAN) algorithm to retrieve vertical profiles of ozone from space-borne observations in nadir-viewing geometry has been developed at the Institute of Environmental Physics (IUP) of the University of Bremen and applied to the TROPOspheric Monitoring Instrument (TROPOMI) L1B spectral data version 2. Spectral data between 270 and 329 nm are used for the retrieval. A recalibration of the measured radiances is done using ozone profiles from MLS/Aura. Studies with synthetic spectra show that individual profiles in the stratosphere can be retrieved with an uncertainty of about 10 %. In the troposphere, the retrieval errors are larger depending on the a priori profile used. The vertical resolution above 18 km is about 6–10 km, and it degrades to 15–25 km below. The vertical resolution in the troposphere is strongly dependent on the solar zenith angle (SZA). The ozone profiles retrieved from TROPOMI with the TOPAS algorithm were validated using data from ozonesondes and stratospheric ozone lidars. Above 18 km, the comparison with sondes shows excellent agreement within less than ±5 % for all latitudes. The standard deviation of mean differences is about 10 %. Below 18 km, the relative mean deviation in the tropics and northern latitudes is still quite good, remaining within ±20 %. At southern latitudes, larger differences of up to +40 % occur between 10 and 15 km. The standard deviation is about 50 % between 7–18 km and about 25 % below 7 km. The validation of stratospheric ozone profiles with ground-based lidar measurements also shows very good agreement. The relative mean deviation is below ±5 % between 18–45 km, with a standard deviation of 10 %. TOPAS retrieval results for 1 d of TROPOMI observations were compared to ozone profiles from the Microwave Limb Sounder (MLS) on the Aura satellite and the Ozone Mapping and Profiler Suite Limb Profiler (OMPS-LP). The relative mean difference was found to be largely below ±5 % between 20–50 km, except at very high latitudes.
- Open Access
- 17 March 2021
- Published by Copernicus GmbH in EGUsphere
- Vol. 2021, 1-36
Ozone Profile Retrieval from nadir TROPOMI measurements in the UV range
The TOPAS algorithm to retrieve vertical profiles of ozone from space-borne observations in nadir viewing geometry has been developed at the Institute of Environmental Physics (IUP) of the University of Bremen and applied to TROPOMI L1B spectral data version 2. The spectral data between 270 and 329 nm are used for the retrieval. A re-calibration of the measured radiances is done using ozone profiles from MLS/Aura. Studies with synthetic spectra show that individual profiles in the stratosphere can be retrieved with the accuracy of about 10 %. In the troposphere, the retrieval errors are larger depending on the a-priori profile used. The vertical resolution above 18 km is about 6–10 km and it degrades to 15–25 km below. The vertical resolution in the troposphere is strongly dependent on the solar zenith angle (SZA). The ozone profiles retrieved from TROPOMI with the TOPAS algorithm were validated using data from ozone sondes and stratospheric ozone lidars. Above 18 km, the comparison with sondes shows excellent agreement within less than ±5 % for all latitudes. The standard deviation of mean differences is about 10 %. Below 18 km, the relative mean deviation in the tropics and northern latitudes is still quite good remaining within ±20 %. At southern latitudes larger differences of up to +40 % occur between 10 and 15 km. The standard deviation is about 50 % between 7–18 km and about 25 % below 7 km. The validation of stratospheric ozone profiles with ground-based lidar measurements also shows very good agreement. The relative mean deviation is below ±5 % between 18–45 km with a standard deviation of 10 %. TOPAS retrieval results for one day of TROPOMI observations were compared to MLS and OMPS-LP data. The relative mean difference was found to be largely below ±5 % between 20–50 km with exception of very high latitudes.
- 17 March 2021
- Published by Copernicus GmbH in EGUsphere
- Vol. 2021, 1-36
Open AccessOzone Profile Retrieval from nadir TROPOMI measurements in the UV range
The TOPAS algorithm to retrieve vertical profiles of ozone from space-borne observations in nadir viewing geometry has been developed at the Institute of Environmental Physics (IUP) of the University of Bremen and applied to TROPOMI L1B spectral data version 2. The spectral data between 270 and 329 nm are used for the retrieval. A re-calibration of the measured radiances is done using ozone profiles from MLS/Aura. Studies with synthetic spectra show that individual profiles in the stratosphere can be retrieved with the accuracy of about 10 %. In the troposphere, the retrieval errors are larger depending on the a-priori profile used. The vertical resolution above 18 km is about 6–10 km and it degrades to 15–25 km below. The vertical resolution in the troposphere is strongly dependent on the solar zenith angle (SZA). The ozone profiles retrieved from TROPOMI with the TOPAS algorithm were validated using data from ozone sondes and stratospheric ozone lidars. Above 18 km, the comparison with sondes shows excellent agreement within less than ±5 % for all latitudes. The standard deviation of mean differences is about 10 %. Below 18 km, the relative mean deviation in the tropics and northern latitudes is still quite good remaining within ±20 %. At southern latitudes larger differences of up to +40 % occur between 10 and 15 km. The standard deviation is about 50 % between 7–18 km and about 25 % below 7 km. The validation of stratospheric ozone profiles with ground-based lidar measurements also shows very good agreement. The relative mean deviation is below ±5 % between 18–45 km with a standard deviation of 10 %. TOPAS retrieval results for one day of TROPOMI observations were compared to MLS and OMPS-LP data. The relative mean difference was found to be largely below ±5 % between 20–50 km with exception of very high latitudes.
- Open Access
- 3 March 2021
- Published by Copernicus GmbH
TOPAS ozone profile retrieval from TROPOMI L1B version 2 dataset
The TOPAS (Tikhonov regularized Ozone Profile retrievAl with SCIATRAN) algorithm to retrieve vertical profiles of ozone from space-borne observations in nadir viewing geometry has been developed at the Institute of Environmental Physics (IUP) of the University of Bremen and applied to TROPOMI L1B spectral data version 2. The data set covers the period from June 2018 to October 2019. But it is not available continuously, but for only single weeks of all 3 months. TROPOMI spectral radiance from channel UV1 and UV2 between 270 nm and 331 nm are used for the retrieval. Since the ozone profiles are very sensitive to absolute calibration at short wavelengths, a re-calibration of the measured radiances is required using comparisons with simulated radiances with ozone limb profiles from collocated MLS/Aura used as input. The time-independent re-calibration bases on simulations for cloud-free pixels of four orbits distributed over the time period. Studies with synthetic spectra show that individual profiles in the stratosphere can be retrieved with the accuracy of about 10%. In the troposphere, the retrieval errors are larger depending on the a-priori profile used. The vertical resolution is between 6 and 10 km above 18 km altitude and 15 – 25 km below. There are around 6 degree of freedom between 0 – 60 km. The TOPAS ozone profiles retrieved from TROPOMI were validated using data from ozone sondes and stratospheric ozone lidars. Above 18 km, the comparison with sondes shows excellent agreement within less than ± 5% for all latitudes. The standard deviation of mean differences is about 10%. Below 18 km, the relative mean deviation in the tropics and northern latitudes is still quite good remaining within ± 20%. At southern latitudes larger differences of up to +40% occur between 10 and 15 km. Here the standard deviation is about 50% between 7 and 18 km and about 25% below 7 km. The validation of stratospheric ozone profiles with ground-based lidar measurements also shows very good agreement. The relative mean deviation is below ± 5% in the 18 – 45 km range with a standard deviation of 10%. A pilot application for one day of TROPOMI data with a comparison to MLS and OMPS confirmed the lidar validation results. The relative mean difference between TROPOMI and MLS or OMPS is largely below ± 5% between 20 – 50 km except for the very high latitudes where differences are getting larger.
- 3 March 2021
- Published by Copernicus GmbH
Open AccessTOPAS ozone profile retrieval from TROPOMI L1B version 2 dataset
The TOPAS (Tikhonov regularized Ozone Profile retrievAl with SCIATRAN) algorithm to retrieve vertical profiles of ozone from space-borne observations in nadir viewing geometry has been developed at the Institute of Environmental Physics (IUP) of the University of Bremen and applied to TROPOMI L1B spectral data version 2. The data set covers the period from June 2018 to October 2019. But it is not available continuously, but for only single weeks of all 3 months. TROPOMI spectral radiance from channel UV1 and UV2 between 270 nm and 331 nm are used for the retrieval. Since the ozone profiles are very sensitive to absolute calibration at short wavelengths, a re-calibration of the measured radiances is required using comparisons with simulated radiances with ozone limb profiles from collocated MLS/Aura used as input. The time-independent re-calibration bases on simulations for cloud-free pixels of four orbits distributed over the time period. Studies with synthetic spectra show that individual profiles in the stratosphere can be retrieved with the accuracy of about 10%. In the troposphere, the retrieval errors are larger depending on the a-priori profile used. The vertical resolution is between 6 and 10 km above 18 km altitude and 15 – 25 km below. There are around 6 degree of freedom between 0 – 60 km. The TOPAS ozone profiles retrieved from TROPOMI were validated using data from ozone sondes and stratospheric ozone lidars. Above 18 km, the comparison with sondes shows excellent agreement within less than ± 5% for all latitudes. The standard deviation of mean differences is about 10%. Below 18 km, the relative mean deviation in the tropics and northern latitudes is still quite good remaining within ± 20%. At southern latitudes larger differences of up to +40% occur between 10 and 15 km. Here the standard deviation is about 50% between 7 and 18 km and about 25% below 7 km. The validation of stratospheric ozone profiles with ground-based lidar measurements also shows very good agreement. The relative mean deviation is below ± 5% in the 18 – 45 km range with a standard deviation of 10%. A pilot application for one day of TROPOMI data with a comparison to MLS and OMPS confirmed the lidar validation results. The relative mean difference between TROPOMI and MLS or OMPS is largely below ± 5% between 20 – 50 km except for the very high latitudes where differences are getting larger.