TWTimothy Jay Webb

Timothy Jay Webb

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Timothy Jay Webb has a total of 107 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A compact recoil spectrometer for time integrated neutron energy spectrum measurements on the Z machine (invited)

    by O. M. Mannion, M. A. Mangan, D. J. Ampleford, P. Cahall, J. Frenje, M. Gatu Johnson, P. Lake, B. Lahmann, M. Lowinske, M. T. McCall, et al.

    A new Compact Recoil Spectrometer (CRS) has been developed to measure time-integrated neutron energy spectra from inertial confinement fusion experiments on the Z machine. Recoil protons, generated as collimated neutrons from the experiment scatter in a hydrogen-rich converter foil located within the diagnostic, are measured with a CR-39 solid-state nuclear track detector. The recoil proton energy spectrum is inferred from the track diameter distribution measured on the CR-39 after chemical etching. The time-integrated neutron energy spectrum is determined from a forward fit to the measured recoil proton energy spectrum using a diagnostic forward model developed in MCNP. Example recoil proton energy spectrum measurements from magnetized liner inertial fusion experiments on Z are presented, and the primary deuterium–deuterium fusion yield and liner areal density are inferred.

  • Theory and simulations to characterize impedance modes due to HERMES III transmission line modifications

    by Albuquerque Sandia National Laboratories (Snl-Nm), Adam Darr, National Nuclear Security Administration, Other (Doe), Timothy Renk, Timothy Webb, Mark Johnston, Kenneth Mikkelson, John Maynard, Michael Mazarakis, et al.

  • Characterization of Variations in Power Flow and Photon Generation in HERMES-III due to Tapering of the Inner and Outer MITL Diameters

    by Albuquerque Sandia National Laboratories (Snl-Nm), Timothy Renk, Other (Doe), Mark Johnston, Timothy Webb, Kenneth Mikkelson, John Maynard, Adam Darr, Michael Mazarakis, Ioana Paraschiv, et al.

  • Open Access

    Erratum: “Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment” [Rev. Sci. Instrum. 94, 031102 (2023)]

    by T. J. Webb, D. E. Bliss, G. A. Chandler, D. H. Dolan, G. Dunham, A. Edens, E. Harding, M. D. Johnston, M. C. Jones, S. Langendorf, et al.

    In our paper,1 we would like to make a few additions and corrections. In our paper,1 we would like to make a few additions and corrections.

  • Progress toward absolute calibrations of DC x-ray sources from 1 keV to >30 keV for Z diagnostics applications

    by Timothy J. Webb, Patrick W. Lake

    Numerous x-ray diagnostics at the Z facility, time-resolved and time-integrated, would benefit from a local calibrated x-ray source. For many years, Z has used low-power Manson x-ray sources to provide some characterization information for components of Z diagnostics below 30 keV. More recently, we have acquired TruFocus x-ray sources, which operate at voltages up to 100 kV depending on the anode material and model. These DC sources have demonstrated good stability and repeatability. Absolute calibrations of either sources or detectors usually involve another calibrated detector from another source, which has not been readily available locally. Therefore, we have adopted the strategy of characterizing a sensitive semiconductor diode detector by controlling or inferring the active volume. This characterized detector is then used to scale the Manson x-ray spectral shape as measured by an Amptek energy-resolving detector. The result agrees well with the modeled source spectrum. We can apply this technique to the TruFocus as well.

  • Open Access

    Controlling morphology and improving reproducibility of magnetized liner inertial fusion experiments

    by D. J. Ampleford, D. A. Yager-Elorriaga, C. A. Jennings, E. C. Harding, M. R. Gomez, A. J. Harvey-Thompson, T. J. Awe, G. A. Chandler, G. S. Dunham, M. Geissel, et al.

    X-ray imaging indicates magnetized liner inertial fusion (MagLIF) stagnation columns have a complicated quasi-helical structure with significant variations in x-ray brightness along the column. In this work, we describe MagLIF experiments aimed at controlling these stagnation structures by varying the initial liner geometry and composition. First, by varying the initial aspect ratio of the liner, we demonstrate a change in the stagnation structures that is consistent with helical magneto Rayleigh–Taylor (MRT) instabilities feedthrough from the outer-to-inner surfaces of the liner. Second, to minimize the seed for such instabilities, we incorporate a dielectric coating on the outer surface of the beryllium liner, which has previously been shown to reduce the growth of the electrothermal instability, a likely seed for MRT growth. Using this coating, we achieve a stagnation column with significantly reduced helical structure and axial variation in x-ray brightness. We discuss how this coating changes the evolution of structures through stagnation along with the spatial uniformity of neutron production. Finally, we show that these more uniform stagnations also result in improved reproducibility in stagnation temperatures and primary DD neutron yield.


  • Open Access

    A generalized approach to x-ray data modeling for high-energy-density plasma experiments

    by T. Nagayama, M. A. Schaeuble, J. R. Fein, G. P. Loisel, M. Wu, D. C. Mayes, S. B. Hansen, P. F. Knapp, T. J. Webb, J. Schwarz, et al.

    Accurate understanding of x-ray diagnostics is crucial for both interpreting high-energy-density experiments and testing simulations through quantitative comparisons. X-ray diagnostic models are complex. Past treatments of individual x-ray diagnostics on a case-by-case basis have hindered universal diagnostic understanding. Here, we derive a general formula for modeling the absolute response of non-focusing x-ray diagnostics, such as x-ray imagers, one-dimensional space-resolved spectrometers, and x-ray power diagnostics. The present model is useful for both data modeling and data processing. It naturally accounts for the x-ray crystal broadening. The new model verifies that standard approaches for a crystal response can be good approximations, but they can underestimate the total reflectivity and overestimate spectral resolving power by more than a factor of 2 in some cases near reflectivity edge features. We also find that a frequently used, simplified-crystal-response approximation for processing spectral data can introduce an absolute error of more than an order of magnitude and the relative spectral radiance error of a factor of 3. The present model is derived with straightforward geometric arguments. It is more general and is recommended for developing a unified picture and providing consistent treatment over multiple x-ray diagnostics. Such consistency is crucial for reliable multi-objective data analyses.


  • Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

    by T. J. Webb, D. E. Bliss, G. A. Chandler, D. H. Dolan, G. Dunham, A. Edens, E. Harding, M. D. Johnston, M. C. Jones, S. Langendorf, et al.

    The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. We review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. We summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.


  • Characterization of self-magnetic pinch radiographic diode performance on RITS-6 at Sandia National Laboratories. II. Coupling between the inductive voltage adder and the SMP load

    by T. J. Renk, B. V. Oliver, M. L. Kiefer, T. J. Webb, J. J. Leckbee, M. D. Johnston, S. Simpson, M. G. Mazarakis

    The self-magnetic pinch (SMP) diode is a type of radiographic diode used to generate an intense electron beam for radiographic applications. At Sandia National Laboratories, SMP was the diode load for the six-cavity radiographic integrated test stand inductive voltage adder (IVA) driver operated in a magnetically insulated transmission line (MITL). The MITL contributes a flow current in addition to the current generated within the diode itself. Extensive experiments with a MITL of 40 Ω load impedance [T. J. Renk et al., Phys. Plasmas 29, 023105 (2022)] indicate that the additional flow current leads to results similar to what might be expected from a conventional high-voltage interface driver, where flow current is not present. However, when the MITL flow impedance was increased to 80 Ω, qualitatively different diode behavior was observed. This includes large retrapping waves suggestive of an initial coupling to low impedance as well as diode current decreasing with time even as the total current does not. A key observation is that the driver generates total current (flow + diode) consistent with the flow impedance of the MITL used. The case is made in this paper that the 80 Ω MITL experiments detailed here can only be understood when the IVA-MITL-SMP diode is considered as a total system. The constraint of fixed total current plus the relatively high flow impedance limits the ability of the diode (whether SMP or other type) to act as an independent load. An unexpected new result is that in tracking the behavior of the electron strike angle on the converter as a function of time, we observed that the conventional cIVx “Radiographic” radiation scaling (where x ∼ 2.2) begins to break down for voltages above 8 MV, and cubic scaling is required to recover accurate angle tracking.


  • Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

    by T. J. Renk, B. V. Oliver, M. L. Kiefer, T. J. Webb, J. J. Leckbee, M. D. Johnston, S. Simpson, M. G. Mazarakis

    Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. There is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.