Praikanok Lertwanitrot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Praikanok Lertwanitrot has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Atthapol Ngaopitakkul
King Mongkut’s Institute of Technology Ladkrabang
5 shared publications Chaichan Pothisarn
School of Engineering, King Mongkuts Institute of Technology Ladkrabang, Bangkok, Thailand
2 shared publications- Panapong Songsukthawan
Center of Specialty Innovation, Bangkok University, Bangkok, Pathum Thani, Thailand
2 shared publications Pathomthat Chiradeja
Faculty of Engineering, Srinakharinwirot University, Bangkok, Thailand
2 shared publications- Santipont Ananwattanaporn
School of International and Interdisciplinary Engineering Programs, School of Engineering, King Mongkut’s Institute of Technology Ladkrabang, Bangkok 10520, Thailand
2 shared publications - Suntiti Yoomak
King Mongkut’s Institute of Technology Ladkrabang
2 shared publications
Latest Publications
- 29 July 2026
- Published by Springer Nature
- p. 131-145
Calculating the Expansion of the 22 kV Electrical Distribution System for the Industrial Factory
- 29 July 2026
- Published by Springer Nature
- p. 131-145
Calculating the Expansion of the 22 kV Electrical Distribution System for the Industrial Factory
- Open Access
- 26 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 151551-151566
Impact of Rising Number of Electric Vehicle Charging Points on Electrical Utility
This paper presents an investigation of the impact of a rising number of electric-vehicle charging points on an interconnected distribution system. Using the PSCAD 4.6 software, this study simulates an electric-vehicle charging station consisting of a charging unit with 2 DC charging and a maximum power of 100 kW. The station receives power from a 23 kV substation through a step-down transformer at 400 V and provides power through the charging unit. The unit regulates the voltage level at 500 V and has a maximum charging capacity of 50 kW each. In addition, the study replicates an actual distribution system of the Provincial Electricity Authority (PEA) in the section spanning the Si Samrong to Sawankhalok substations in Sukhothai Province, Thailand. The effects of the following study conditions on the power quality are observed in the simulation: (1) variable location of charging panels, (2) variable number of charging panels, and (3) additional sets of charging panels in the distribution system. The results show that the charging-panel installation location and number of charging panels are significant factors that affect the power quality, including the voltage level. Therefore, optimizing the design of EV charging stations should consider the location and number of charging panels as important factors.
- 26 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 151551-151566
Open AccessImpact of Rising Number of Electric Vehicle Charging Points on Electrical Utility
This paper presents an investigation of the impact of a rising number of electric-vehicle charging points on an interconnected distribution system. Using the PSCAD 4.6 software, this study simulates an electric-vehicle charging station consisting of a charging unit with 2 DC charging and a maximum power of 100 kW. The station receives power from a 23 kV substation through a step-down transformer at 400 V and provides power through the charging unit. The unit regulates the voltage level at 500 V and has a maximum charging capacity of 50 kW each. In addition, the study replicates an actual distribution system of the Provincial Electricity Authority (PEA) in the section spanning the Si Samrong to Sawankhalok substations in Sukhothai Province, Thailand. The effects of the following study conditions on the power quality are observed in the simulation: (1) variable location of charging panels, (2) variable number of charging panels, and (3) additional sets of charging panels in the distribution system. The results show that the charging-panel installation location and number of charging panels are significant factors that affect the power quality, including the voltage level. Therefore, optimizing the design of EV charging stations should consider the location and number of charging panels as important factors.
- Open Access
- 20 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 116442-116461
Investigation and Study of High Voltage Capacitor Bank Techniques for Voltage Drop Improvement in 22-kV Distribution Line
Voltage drop in distribution lines contributes to power losses, leading to a decrease in the overall efficiency of the electrical power system. In this paper, we investigate methods to improve voltage drop through capacitor bank allocation techniques, specifically installation at the end of the distribution line, the 1/2-kvar rule, and the 2/3-kvar rule. In the case study, a 22 kV overhead distribution line in Thailand is utilized as a model to analyze voltage drop improvement. The study is conducted using PSCAD software to simulate and evaluate the effectiveness of various capacitor bank allocation techniques in enhancing voltage drop in the distribution line. In addition, the impact of capacitor bank placement and sizing on voltage drop mitigation in a distribution line is analyzed through a proposed mathematical framework. This analysis considers the interaction between reactive current compensation and impedance of a distribution line, ensuring an optimized approach for capacitor bank deployment to enhance voltage drop. The results emphasize that the capacitor bank installation at the end of the distribution line yields the most substantial voltage drop improvement. This is attributed to the utilization of larger capacitor bank capacities compared to the 1/2-kvar and 2/3-kvar methods. Furthermore, the mathematical analysis confirms that both the placement and sizing of capacitor banks play a crucial role in voltage drop mitigation.
- 20 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 116442-116461
Open AccessInvestigation and Study of High Voltage Capacitor Bank Techniques for Voltage Drop Improvement in 22-kV Distribution Line
Voltage drop in distribution lines contributes to power losses, leading to a decrease in the overall efficiency of the electrical power system. In this paper, we investigate methods to improve voltage drop through capacitor bank allocation techniques, specifically installation at the end of the distribution line, the 1/2-kvar rule, and the 2/3-kvar rule. In the case study, a 22 kV overhead distribution line in Thailand is utilized as a model to analyze voltage drop improvement. The study is conducted using PSCAD software to simulate and evaluate the effectiveness of various capacitor bank allocation techniques in enhancing voltage drop in the distribution line. In addition, the impact of capacitor bank placement and sizing on voltage drop mitigation in a distribution line is analyzed through a proposed mathematical framework. This analysis considers the interaction between reactive current compensation and impedance of a distribution line, ensuring an optimized approach for capacitor bank deployment to enhance voltage drop. The results emphasize that the capacitor bank installation at the end of the distribution line yields the most substantial voltage drop improvement. This is attributed to the utilization of larger capacitor bank capacities compared to the 1/2-kvar and 2/3-kvar methods. Furthermore, the mathematical analysis confirms that both the placement and sizing of capacitor banks play a crucial role in voltage drop mitigation.
- Open Access
- 6 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 65287-65297
Comparative Fault Detection Between DWT and STFT in Overcurrent Relays
This study proposes a protection relay using a microcontroller to detect and classify faults in transmission lines based on the Wavelet transform. An experimental model was constructed from an actual 115 kV transmission system prototype. The current signal was observed based on the fault type, phase, and position. Clark’s transform and the discrete Wavelet transform (DWT) were applied to transform signals for analysis. The positive and zero sequences obtained from Clark’s transform were used for fault detection and fault classification, respectively. Moreover, the performances between the DWT and the short-time Fourier Transform (STFT) were compared in terms of accuracy and processing time. In addition, the double-detection technique was used to confirm the accuracy of fault detection. Results show that the proposed method is efficient for fault detection and classification. This finding allows the researcher to choose the appropriate analytical method. Moreover, it can also be used as the basis for overcurrent relay algorithm design in the effort to develop more advanced technologies.
- 6 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 65287-65297
Open AccessComparative Fault Detection Between DWT and STFT in Overcurrent Relays
This study proposes a protection relay using a microcontroller to detect and classify faults in transmission lines based on the Wavelet transform. An experimental model was constructed from an actual 115 kV transmission system prototype. The current signal was observed based on the fault type, phase, and position. Clark’s transform and the discrete Wavelet transform (DWT) were applied to transform signals for analysis. The positive and zero sequences obtained from Clark’s transform were used for fault detection and fault classification, respectively. Moreover, the performances between the DWT and the short-time Fourier Transform (STFT) were compared in terms of accuracy and processing time. In addition, the double-detection technique was used to confirm the accuracy of fault detection. Results show that the proposed method is efficient for fault detection and classification. This finding allows the researcher to choose the appropriate analytical method. Moreover, it can also be used as the basis for overcurrent relay algorithm design in the effort to develop more advanced technologies.
- Open Access
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 35709-35717
Application of Magnitude and Phase Angle to Boundary Area-Based Algorithm for Unbalance Relay Protection Scheme in 115-kV Capacitor Bank
Identification of fault locations in capacitor banks is still under development. Although, faults in capacitor banks can be detected by an unbalance relay, it cannot identify the fault location. To address this issue, this study proposes an algorithm that can categorize protection zones, identify fault phases, and identify the fault locations in a capacitor bank using the phase angle boundary area. The result showed that the proposed algorithm was effective in indicating the fault location. Performance of the proposed algorithm was compared with conventional methods based on the Electricity Generating Authority of Thailand standard and phasor diagrams. It was verified that the proposed algorithm was more effective than the conventional methods. It is useful for the development of the unbalance relay operation.
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 35709-35717
Open AccessApplication of Magnitude and Phase Angle to Boundary Area-Based Algorithm for Unbalance Relay Protection Scheme in 115-kV Capacitor Bank
Identification of fault locations in capacitor banks is still under development. Although, faults in capacitor banks can be detected by an unbalance relay, it cannot identify the fault location. To address this issue, this study proposes an algorithm that can categorize protection zones, identify fault phases, and identify the fault locations in a capacitor bank using the phase angle boundary area. The result showed that the proposed algorithm was effective in indicating the fault location. Performance of the proposed algorithm was compared with conventional methods based on the Electricity Generating Authority of Thailand standard and phasor diagrams. It was verified that the proposed algorithm was more effective than the conventional methods. It is useful for the development of the unbalance relay operation.