Rong Xiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rong Xiang has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Jana Schaber
SRF-Gun Group, ELBE Department, Institute of Radiation Physics, Helmholtz-Zentrum Dresden-Rossendorf, 01328 Dresden, Germany
3 shared publications - Andre Arnold
Helmholtz Zentrum Dresden Rossendorf, Institute of Radiation Physics ELBE Dresden Germany
2 shared publications - Anton A. Ryzhov
Vavilov State Optical Institute
2 shared publications - Jochen Teichert
Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany
2 shared publications - Peter Michel
Helmholtz Zentrum Dresden Rossendorf, Institute of Radiation Physics ELBE Dresden Germany
2 shared publications - Baocheng Zhang
Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan, China
1 shared publication
Latest Publications
- Open Access
- 22 February 2023
- Published by Wiley in Surface and Interface Analysis
- Vol. 55 (6-7) , 507-514
Impact of various cleaning procedures on p‐GaN surfaces
This work discusses the influence of different cleaning procedures on p‐gallium nitride (GaN) grown on sapphire by metal–organic chemical vapor deposition. The cleaned p‐GaN surface was transferred into an ultrahigh vacuum chamber and studied by an X‐ray photoelectron spectrometer, revealing that a cleaning with a so‐called “piranha” procedure results in low carbon and oxygen concentrations on the p‐GaN surface. Contrary, a cleaning that solely uses ethanol represents a simple cleaning but leads to an increase of carbon and oxygen contaminations on the surface. Afterward, the cleaned p‐GaN samples underwent a subsequential vacuum thermal cleaning at various temperatures to achieve an atomically clean surface. X‐ray photoelectron spectroscopy (XPS) measurements revealed residual oxygen and carbon on the p‐GaN surface. Thus, a thermal treatment under a vacuum did not entirely remove these organic contaminations, although the thermal cleaning reduced their peak intensities. The complete removal of carbon and oxygen contaminants was only achieved by argon ion sputtering, which is accompanied by a strong depletion of the nitrogen on the p‐GaN surface. The treatments cause a large number of surface defects preventing the formation of a negative electron surface when the p‐GaN is activated with a thin layer of cesium.
- 22 February 2023
- Published by Wiley in Surface and Interface Analysis
- Vol. 55 (6-7) , 507-514
Open AccessImpact of various cleaning procedures on p‐GaN surfaces
This work discusses the influence of different cleaning procedures on p‐gallium nitride (GaN) grown on sapphire by metal–organic chemical vapor deposition. The cleaned p‐GaN surface was transferred into an ultrahigh vacuum chamber and studied by an X‐ray photoelectron spectrometer, revealing that a cleaning with a so‐called “piranha” procedure results in low carbon and oxygen concentrations on the p‐GaN surface. Contrary, a cleaning that solely uses ethanol represents a simple cleaning but leads to an increase of carbon and oxygen contaminations on the surface. Afterward, the cleaned p‐GaN samples underwent a subsequential vacuum thermal cleaning at various temperatures to achieve an atomically clean surface. X‐ray photoelectron spectroscopy (XPS) measurements revealed residual oxygen and carbon on the p‐GaN surface. Thus, a thermal treatment under a vacuum did not entirely remove these organic contaminations, although the thermal cleaning reduced their peak intensities. The complete removal of carbon and oxygen contaminants was only achieved by argon ion sputtering, which is accompanied by a strong depletion of the nitrogen on the p‐GaN surface. The treatments cause a large number of surface defects preventing the formation of a negative electron surface when the p‐GaN is activated with a thin layer of cesium.
- Top Cited PapersOpen Access
- 17 February 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 11 (9) , 3162-3179
Review of photocathodes for electron beam sources in particle accelerators
This paper compares different photocathodes that are applicable for electron injector systems and summarizes the most important photocathode properties influencing the performance as an electron source.
- 17 February 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 11 (9) , 3162-3179
Top Cited PapersOpen AccessReview of photocathodes for electron beam sources in particle accelerators
This paper compares different photocathodes that are applicable for electron injector systems and summarizes the most important photocathode properties influencing the performance as an electron source.
- Open Access
- 4 March 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (3) , 033401
Successful user operation of a superconducting radio-frequency photoelectron gun with Mg cathodes
At the electron linac for beams with high brilliance and low emittance (ELBE) center for high-power radiation sources, the second version of a superconducting radio-frequency (SRF) photoinjector has been put into operation and has been routinely applied for user operation at the ELBE electron accelerator. SRF guns are suitable for generating a continuous wave electron beam with high average currents and high beam brightness. The SRF gun at ELBE has the goal to generate short electron pulses with bunch charges of 200–300 pC at typical repetition rates of 100 kHz for the production of superradiant, coherent terahertz radiation. The SRF gun includes a 3.5-cell, 1.3-GHz niobium cavity and a superconducting solenoid. A support system with liquid nitrogen () cooling allows the operation of normal-conducting, high quantum efficiency photocathodes. We present the design and performance of the SRF gun as well as beam measurement results of the operation with Mg photocathodes at an acceleration gradient of (4 MeV kinetic energy). In the last section, we discuss the SRF gun application for production of coherent terahertz radiation at the ELBE facility.- 4 March 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (3) , 033401
Open AccessSuccessful user operation of a superconducting radio-frequency photoelectron gun with Mg cathodes
At the electron linac for beams with high brilliance and low emittance (ELBE) center for high-power radiation sources, the second version of a superconducting radio-frequency (SRF) photoinjector has been put into operation and has been routinely applied for user operation at the ELBE electron accelerator. SRF guns are suitable for generating a continuous wave electron beam with high average currents and high beam brightness. The SRF gun at ELBE has the goal to generate short electron pulses with bunch charges of 200–300 pC at typical repetition rates of 100 kHz for the production of superradiant, coherent terahertz radiation. The SRF gun includes a 3.5-cell, 1.3-GHz niobium cavity and a superconducting solenoid. A support system with liquid nitrogen () cooling allows the operation of normal-conducting, high quantum efficiency photocathodes. We present the design and performance of the SRF gun as well as beam measurement results of the operation with Mg photocathodes at an acceleration gradient of (4 MeV kinetic energy). In the last section, we discuss the SRF gun application for production of coherent terahertz radiation at the ELBE facility. - 1 January 2004
- Published by Elsevier
- p. 321-325
Experimental investigations of DC-SC photoinjector at Peking University⋆⋆Supported in part by Chinese Department of Science and Technology under the National Basic Research Projects (No. 2002CB713602) and by National Natural Science Foundation of China (10075006)(19985001).
- 1 January 2004
- Published by Elsevier
- p. 321-325
Experimental investigations of DC-SC photoinjector at Peking University⋆⋆Supported in part by Chinese Department of Science and Technology under the National Basic Research Projects (No. 2002CB713602) and by National Natural Science Foundation of China (10075006)(19985001).