GMGiulia Mazzarotto

Giulia Mazzarotto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Giulia Mazzarotto has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Challenges and Strategies in Urban Adaptation to Climate Risks: The Case of St. Mark's Square (Venice, Italy)

    by Giulia Mazzarotto, Paolo Salandin

    In recent decades, Venice has experienced increasing frequency of extreme high-tide events, driven by a combination of land subsidence, eustatic sea-level rise, and changes in climatic forces. To mitigate flood risk, an adaptation strategy was implemented in 2019 at the three inlets (Lido, Malamocco, and Chioggia) connecting the Venice Lagoon with the Adriatic Sea: the Mo.S.E. (Modulo Sperimentale Elettromeccanico) storm-surge barrier system. The barriers are activated when the sea level is expected to exceed 1.10 m a.P.S. (“above Punta della Salute”), being the 1.10 value a compromise between effective flood protection and the economic impacts due to the stop of maritime traffic during barrier closure.Nevertheless, by the time this level is reached, about 12% of Venice is already flooded, including the iconic St. Mark’s Square (ground elevations between 0.60 and 1.10 m a.P.S.). During flooding episodes, surface runoff from the Square is conveyed into the historic drainage network (gàtoli). When high tide conditions also occur, the runoff interacts with the backwater effect within the gàtoli as saltwater rises from the Lagoon. As flooding progresses, water ponds in front of St. Mark's Basilica (0.6 m a.P.S.) and gradually expands to the rest of the Square.Following the extreme event of 2019, a first intervention (installation of glass barriers to protect the Basilica) was implemented in 2022. However, a more comprehensive series of targeted interventions has been planned since 2020. This holistic approach extends beyond the Basilica, encompassing the entire Square to preserve the integrity of the whole area. During high tide events, the Square will thus be isolated from the Lagoon when the water level exceeds 0.7 m a.P.S. While water entering the gàtoli system through precipitation runoff, lagoon wave overtopping, and subsurface infiltration, is actively managed by the new flood defence system, efficiently conveying and discharging water outside the Square. The multi-faceted strategy includes the permanent sealing of minor gàtoli-lagoon connections and the controlled operation of major ones, as well as localized elevation of the Square's pavement. Additionally, floating breakwaters are installed to limit wave overtopping discharge, while the gàtoli tunnels are restored to enhance their conveyance capacity. A pumping station, whose strategic position allows easy maintenance procedures, ensures the required outlet discharge.In this study, the hydraulic processes affecting St. Mark’s Square are analysed using InfoWorks ICM (Integrated Catchment Model), which couples a 1D model of the drainage network with a 2D representation of flooding dynamics over the Square. Water inputs (rainfall, groundwater infiltration, and lagoon wave overtopping) are quantified using a combination of theoretical and experimental approaches, and the overall discharge capacity of the Square is evaluated to assess the current performance of the drainage system. Subsequently, the study investigates the effects of various restoration and adaptation scenarios to assess their effectiveness in mitigating flooding under different forcing conditions.

  • Open Access

    Laboratory Experiments and Integrated Surface-Subsurface Hydrological Modeling to Evaluate a Permeable Pavement Performance

    by Giulia Mazzarotto, Matteo Camporese, Paolo Salandin

    Permeable Pavements (PPs) are a type of Sustainable Drainage Systems that reduce runoff in urban areas and the related discharge to the drainage network, thereby decreasing the risk of flooding without the need of changing the end of use of the retrofitted areas. However, uncertainty affecting their performance and the lack of a comprehensive understanding of the physical processes governing their functionality are still current issues that limit their installation.Several numerical models have been employed to describe hydraulic processes in PPs. Typically, these models focus solely on simulating flows through variably saturated porous media using 1D and 2D approaches. However, this approach neglects or oversimplifies surface processes and their interaction with subsurface flows. The water exchange at the surface-subsurface interface is intrinsically linked to the infiltration process in the underlying soil layer. Surface runoff, when present, is influenced by the geometric and hydraulic properties of the surface as well as the local infiltration capacity.These features can be adequately represented by Integrated Surface-Subsurface Hydrological models (ISSHMs) such as CATHY (Catchment Hydrology, Camporese et al., 2010), a spatially distributed and physically based model that jointly describes runoff and infiltration processes.Here, the CATHY model has been used together with experiments developed in a lab facility to achieve a detailed understanding of the physical processes occurring in PPs.The lab model was developed reproducing a 1:1 scale permeable parking lot section, 6 m long, 2 m wide and with thickness varying between 0.9 and 1 m (surface longitudinal slope of about 1.2%), enclosed within a 6×2 m2 concrete box.The CATHY model is used to simulate the hydraulic response of the PP subjected to artificial rainfall events generated through a rainfall simulator (Lora et al., 2016). No-flow boundary conditions are imposed at the bottom and lateral sides to reproduce the impermeable concrete walls surrounding the PP. A seepage face boundary condition is assumed downstream to simulate the subsurface flow through the porous wall on the downstream side of the facility.Data regarding the water table evolution is continuously gathered through spatially distributed sensors (tensiometers and piezometers), along with surface runoff and subsurface discharge measurements collected at the downstream end via tipping bucket flow gauges. The dataset is used to calibrate the CATHY parameters, i.e., the hydraulic characteristics of the pavement tiles and of the aggregate materials forming the filter layer package. A first set of parameters are defined according to literature review and laboratory tests on the aggregate materials.Despite difficulties encountered in the evaluation of the parameters, the calibrated ISSHM represents a useful tool to achieve a better understanding of the physical processes characterizing PPs.

  • Open Access

    Insights on permeable pavement hydraulic performance from large-scale laboratory experiments and physically based modelling

    by Giulia Mazzarotto, Matteo Camporese, Paolo Salandin

    Among other Sustainable Urban Drainage Systems, Permeable Pavements (PPs) are one can be easily retrofitted in the urban environment. However, they suffer of clogging phenomena that reduces their efficiency over time. Laboratory experiments to assess the hydraulic performance of a newly constructed PP subjected to different rainfall intensities have been conducted using a large-scale laboratory model (2x6 m2 with 1.2\% slope). The surface of the upstream portion (1.7x2 m2) is impermeable to simulate runoff generation over impermeable surfaces, while the downstream portion (4.3x2 m2) is realized with PICP. The downstream vertical side of the PP is made of permeable bricks and two gutter channels are placed crosswise to separately collect runoff and subsurface discharge. The remaining sides, as well as the bottom of the model, are impermeable. The filter package below the PICP consists of three layers: 5 cm bedding (3-6 mm gravel), a 10 cm base layer (8-12 mm gravel) and a 30 cm sub-base layer (20/40 mm gravel), which is laid on top of a 40 cm layer of native sand (silty sand with d50=0.23 mm). A geotextile separates the bedding and base layers and a 4m long drainpipe (D=150 mm) was inserted in the sub-base layer. The facility is equipped with probes on both lateral sides: 6 tensiometers in the native sand, 4 water content reflectometers in the base and sub-base layers, and 3 piezometers to record water table evolution throughout the experiments and degree of saturation of the filter layer package. Runoff and subsurface discharge are separately conveyed to two tipping bucket rain gauges. A rainfall simulator is used to generate quite uniform rainfall distribution (80 - 150 mm/h intensity) for 15 minutes or 30 minutes. Moreover, an Integrated Surface-Subsurface Hydrological model (CatHy) has been used to model the permeable pavement, assess and support data collected from the laboratory experiments.Results from the laboratory experiments performed have proven the efficiency of a newly constructed permeable pavement to very intense rainfall events. The monitoring with spatially distributed sensors allowed to assess the evolution in time of the water table as well the “recovery” phase to pre-event conditions after the event. This is useful to assess the effect of repeated rainfall events at short distance in time. For each experiment performed, a rapid increase of subsurface discharges was recorded by the tipping bucket, whereas surface runoff occurred only for short and intense rainfall events (approximately 150 mm/h for 15 min). The system did not reach saturated conditions in any of the performed experiments due to the high permeability of the filter layer package. The monitoring with spatially distributed sensors also allowed to assess the heterogeneities of the physical processes (synthetic rainfall events, infiltration processes) as well as of the filter layer package. Future laboratory experiments simulating clogging phenomena will be performed and compared to the results obtained from the developed experiments up to now and of the ISSH model.


  • Open Access

    Mitigation strategies against seawater intrusion in the context of climate change

    by Paolo Salandin, Enrica Belluco, Matteo Camporese, Elena Crestani, Giovanna Darvini, Pietro Giaretta, Giulia Mazzarotto

    In coastal regions, where about 40% of world population is settled, freshwater aquifers are affected by a saltwater intrusion. The presence of elevate salt concentrations, among the most common pollutants in groundwater aquifers, represents a world-wide spread problem for coastal areas, such as Mediterranean coasts, both East and West coasts in the U. S., Gulf of Mexico and Middle East coasts. The seriousness of the situation is enhanced by the high demand of water supply, especially in the drier periods, and by the mean sea-level rise due to climate change. So that seawater will encroach farther inland and will threaten the available fresh groundwater supply, affecting not only human livelihood, but also coastal ecosystems. The form and transformation of the seaward hydraulic gradient of the aquifer and a constant freshwater discharge into the sea are fundamental in order to control the rate of intrusion.To maintain the seaward gradient in the system the aquifer may be artificially recharged by freshwater by increasing the inland piezometric heads. The purpose of this solution is to create a hydraulic barrier against the inland flow of saline water by injecting freshwater in the vicinity of the shoreline. For phreatic aquifers both injection wells and surface spreading of water, such as irrigation, may be applied. Surface reservoirs, lakes and canals can be used as recharge systems for unconfined aquifers through freshwater infiltration (Hussain et al., 2019).To assess the effectiveness of this mitigation approach and the amount of volumes of freshwater required, physical experiments are developed in a laboratory canal developed to reproduce a controlled heterogeneous porous media.The sandbox measures 500 cm long by 30 cm wide by 60 cm high, with 3 cm thick plexiglass walls. Two tanks are located upstream and downstream from the sandbox, with volumes of about 0.5 m3 and 2.0 m3, respectively. The upstream tank is filled with fresh-water and is continuously supplied by a small pump, providing fresh-water recharge. The downstream tank is filled with salt-water, previously prepared by adding salt to fresh-water till a proper density is reached, and it represents the sea. This canal has been used in previous works (Bouzaglou et al., 2018, Crestani et al., 2022), but in the present the homogeneous porous media has been substituted by three different nominal size ranges of glass beads, equal to 0.3-0.4, 0.4-0.8 and 1.0-1.3 mm respectively, organized in 250 cells, each of size 20x30x5 cm3 to reproduce a prescribed statistical anisotropic structure.The evidences deduced from the physical experiments developed simulating the seawater intrusion-retreat phenomenon due to drought periods are discussed in comparison with the results of a numerical model.


  • Open Access

    Assessing Physical Processes of Permeable Pavements with a Large-Scale Laboratory Model

    by Giulia Mazzarotto, Matteo Camporese, Paolo Salandin

    In recent decades, due to on-going urbanization and changes in rainfall patterns, urban drainage systems are facing increasing challenges. The expansion of impermeable surfaces and the increase of both frequency and intensity of rainfall events, are responsible for the augmented peak-flows and heavily polluted stormwater volumes conveyed by combined sewer overflows to water bodies. The need of assessing these challenges to mitigate the impact on water bodies’ quality has prompted International Authorities to develop standards and scientific communities to find solutions for an effective stormwater management.Sustainable Drainage Systems are effective at-source stormwater management solutions designed for collecting, retaining, and infiltrating direct rainfall and runoff from impervious surfaces. When properly applied in the urban drainage system, they mitigate pollution coming from wash-off of impervious surfaces and reduce both volumes and flood peaks conveyed to the drainage system.Among others, Permeable pavements (PPs) and infiltration trenches (ITs) are two solutions that can be easily retrofitted into the urban environment. PPs reduce surface runoff allowing direct infiltration of rainfall, whereas ITs collect runoff from nearby impervious surfaces. Both can temporally store relevant amount of water which is then slowly released to deeper native soil layers. Moreover, these systems act as filters trapping solids and pollutants onto or into the filter layers. However, physical clogging related to particle accumulation on the surface or inside the porous media reduce permeability of the system decreasing infiltration rates along time. This is a crucial aspect affecting both PPs and ITs effectiveness that must be accounted in the urban environment maintenance plans.A large-scale laboratory model is currently under development to analyze the main physical processes and to assess the efficiency starting first from the PPs. To this aim, a laboratory facility (Lora et al., 2016), built in the Laboratory of Hydraulics and Hydraulic Works of the Department of Civil, Environmental and Architectural Engineering (University of Padova), is being rearranged. The facility consists of a reinforced concrete box 6 m long x 2 m wide, and the height varies from 3.5 to 0.5 m. It is equipped with 50 openings on each lateral side for the insertion of probes (e.g. water content reflectometers - WCR) to continuously collect long term monitoring data in different positions. The end side of the facility is made of porous bricks allowing subsurface runoff to drain into a V-notch stream gauge. Another stream gauge is installed to measure exceeding surface runoff. During experiments, steady rainfall intensities ranging from 50 to 150 mm/h will be produced with a specifically designed rainfall simulator.Suitable materials for the filter layers package will be laid for 1 m total depth assessing filtration processes through the probes in three positions along the vertical. The rainfall simulator will be rearranged to guarantee uniform rainfall distribution on the PP surface characterized by a mild slope (about 2-3%).In the first set of experiments, the characteristics of the investigated PP will be tested in clear water condition, thus without adding suspended solids, to define the maximum infiltration capacity.

  • Open Access

    Impact of urban areas' drainage system on the quality of water bodies and mitigation strategies

    by Giulia Mazzarotto, Paolo Salandin

    Diffuse urban pollution is a significant factor in compromising receiving water and groundwater standards required by the EU Water Framework Directive. Many studies (e.g., Ashley et al., 2005; McGrane, 2016) show that changes in the built environment and climatic forces contribute to the increase of combined sewer system overflows and of stormwater directly conveyed to nearby water bodies. These discharges are responsible for receiving water contamination, as a result of high concentrations of pathogens, BOD, suspended solids (SS), hydrocarbons, heavy metals and nutrients, thus being a significant source of water bodies’ pollution.To mitigate/eliminate pathogens and BOD contamination sources, the combined drainage system is usually split into separated sanitary sewer and stormwater systems, although difficulties related to economic and technical feasibility may be relevant. Nevertheless, this solution does not solve completely pollution due to SS, hydrocarbons, heavy metals from urban areas runoff and nutrients from rural drainage.Sustainable Drainage Systems (SuDS) deal with stormwater at source, helping infiltration and storage of water, increasing groundwater recharge, and reducing peak flood and volume in the drainage system. Moreover, filtration processes through porous media may reduce pollutants driven by first flush, usually controlled by stormwater tanks and sewer system spillways. However, clogging phenomenon limits drainage efficiency in the long-term, making sometimes porous media itself a source of contamination.In the following, a PhD project focusing on the urban area of Treviso is illustrated. Treviso is crossed by the river Sile, one of the longest (95 km) European wellspring rivers, part of a protected area. The Sile river is polluted by discharges from both the existing combined sewer system and rural drainages.While responsible agricultural practices will be promoted to mitigate the pollution originating from rural areas, a project aims to separate the combined system, developing a new pipe network for sanitary wastewater. When properly applied in the present drainage system devoted to the stormwater control only, SuDS solutions are able to mitigate pollution coming from wash-off and reduce flood peaks.Discharge measurement stations will be realised on the Sile river upstream and downstream the Treviso town, to quantify drainage system outflows of the urban area during rainfall events and in dry conditions. Sampling for qualitative analysis will give a measure of the pollutants’ concentration.SuDS solutions, e.g. porous pavements, infiltration trenches and vegetated swales, will be tested with laboratory equipment (6×2 m2) capable of considering the runoff and underground drainage in a fully controlled environment subjected to a prescribed rainfall intensity. By this way it will be possible to analyse the main physical processes and assess the SuDS solutions’ efficiency both in the short and long-term, using advanced mathematical models for the interpretation of results.If the laboratory model will provide satisfactory results, a full-scale test will be developed on an experimental site in Treviso town. The installed qualitative and quantitative monitoring system will allow to determine the effectiveness of the solutions adopted.