Martina Tognini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Martina Tognini has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Alister Hart
Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore, UK
3 shared publicationsHarry Hothi
Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore, UK
3 shared publications- Harry Hothi
The Royal National Orthopaedic Hospital, Stanmore, UK
3 shared publications Johann Henckel
Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore, UK
3 shared publicationsMasood Shafafy
Department of Trauma and Orthopaedics, Nottingham University Hospitals NHS Trust, Nottingham, UK
3 shared publicationsStewart Tucker
Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
3 shared publications
Latest Publications
- 23 September 2024
- Published by Springer Nature in Spine Deformity
- Vol. 13 (1) , 299-309
Outcome of distraction-based growing rods at graduation: a comparison of traditional growing rods and magnetically controlled growing rods
Introduction Distraction-based growing rods have been considered as an alternative surgical option for the operative treatment of EOS. TGR has been challenged by MCGR, which is reported to have the advantage of non-invasive lengthening with fewer planned returns to theatre. This study explores the radiographic outcomes, Unplanned Returns to the Operating Room (UPROR) and complication profile of both the procedures at the end of the planned growing rod treatment with either TGR or MCGR. Methods We included all the EOS cases from the PSSG database that underwent either TGR or MCGR with spine-based proximal anchors, followed up to the time of graduation. Any crossover or hybrid procedures were excluded. 549 patients (409 TGR and 140 MCGR) were eligible for review. We measured the coronal curve magnitude, Kyphosis, T1–T12, T1–S1 and L1–S1 lengths at 4 time points (before and after the index surgery and before and after the definitive surgery). Results The TGR group were slightly younger at the time of the index procedure (7 years for TGR vs. 8.5 years for MCGR, p < 0.001). We noted an improvement in all radiological parameters after the growing rod implantation. The spinal lengths increased through the lengthening period, while the coronal curve magnitude and the kyphosis increased. The kyphosis normalized following the final fusion, the coronal curve magnitude reduced further with a further increase in spinal lengths. The final follow-up from the time of the index implantation to the definitive surgery was 5.1 years (IQR 3.8) in TGR and 3.5 years (IQR 1.65) in the MCGR groups. The total number of complications was fewer in the MCGR group. The overall risk of UPROR was lower in the MCGR group and implant breakage was less in the MCGR group by 4.7 times. Conclusions This study confirms the equivalence of both the distraction-based growing rods systems from the radiological stand-point, during the lengthening phase and at the time of the definitive surgery. The TGR was more kyphogenic during the lengthening period. The complications and UPROR were fewer in the MCGR groups.
- 23 September 2024
- Published by Springer Nature in Spine Deformity
- Vol. 13 (1) , 299-309
Outcome of distraction-based growing rods at graduation: a comparison of traditional growing rods and magnetically controlled growing rods
Introduction Distraction-based growing rods have been considered as an alternative surgical option for the operative treatment of EOS. TGR has been challenged by MCGR, which is reported to have the advantage of non-invasive lengthening with fewer planned returns to theatre. This study explores the radiographic outcomes, Unplanned Returns to the Operating Room (UPROR) and complication profile of both the procedures at the end of the planned growing rod treatment with either TGR or MCGR. Methods We included all the EOS cases from the PSSG database that underwent either TGR or MCGR with spine-based proximal anchors, followed up to the time of graduation. Any crossover or hybrid procedures were excluded. 549 patients (409 TGR and 140 MCGR) were eligible for review. We measured the coronal curve magnitude, Kyphosis, T1–T12, T1–S1 and L1–S1 lengths at 4 time points (before and after the index surgery and before and after the definitive surgery). Results The TGR group were slightly younger at the time of the index procedure (7 years for TGR vs. 8.5 years for MCGR, p < 0.001). We noted an improvement in all radiological parameters after the growing rod implantation. The spinal lengths increased through the lengthening period, while the coronal curve magnitude and the kyphosis increased. The kyphosis normalized following the final fusion, the coronal curve magnitude reduced further with a further increase in spinal lengths. The final follow-up from the time of the index implantation to the definitive surgery was 5.1 years (IQR 3.8) in TGR and 3.5 years (IQR 1.65) in the MCGR groups. The total number of complications was fewer in the MCGR group. The overall risk of UPROR was lower in the MCGR group and implant breakage was less in the MCGR group by 4.7 times. Conclusions This study confirms the equivalence of both the distraction-based growing rods systems from the radiological stand-point, during the lengthening phase and at the time of the definitive surgery. The TGR was more kyphogenic during the lengthening period. The complications and UPROR were fewer in the MCGR groups.
- 17 July 2023
- Published by Elsevier in Journal of Orthopaedics
- Vol. 42, 63-69
Growing rods in Early Onset Scoliosis: The current scenario
- 17 July 2023
- Published by Elsevier in Journal of Orthopaedics
- Vol. 42, 63-69
Growing rods in Early Onset Scoliosis: The current scenario
- Open Access
- 19 June 2023
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 43 (8) , 486-491
Pin Fracture in Magnetically Controlled Growing Rods: Influence of the Year of Manufacture
Background: Magnetically controlled growing rods (MCGRs) have a known issue with fracture of the internal locking pin resulting in early revisions. The manufacturer reported that rods manufactured before March 26, 2015, had a 5% risk of locking pin fracture. Locking pins made after this date are thicker in diameter and of a tougher alloy; their rate of pin fracture is not known. The aim of this study was to better understand the impact of the design changes on the performance of MCGRs. Methods: This study involves 46 patients with 76 removed MCGRs. Forty-six rods were manufactured before March 26, 2015, and 30 rods after that date. Clinical and implant data were collected for all MCGRs. Retrieval analysis comprised plain radiographs evaluations, force and elongation testing, and disassembly. Results: The 2 patient groups were statistically comparable. We found that 14 of 27 patients implanted with rods manufactured before March 26, 2015 (group I) had a fracture of their locking pins. Three of the 17 patients with rods manufactured after this date (group II) were also found to have a fractured pin. Conclusions: Retrieved rods collected at our center and made after March 26, 2015, had far fewer locking pin fractures than those made before this date; this may be due to the change in pin design.
- 19 June 2023
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 43 (8) , 486-491
Open AccessPin Fracture in Magnetically Controlled Growing Rods: Influence of the Year of Manufacture
Background: Magnetically controlled growing rods (MCGRs) have a known issue with fracture of the internal locking pin resulting in early revisions. The manufacturer reported that rods manufactured before March 26, 2015, had a 5% risk of locking pin fracture. Locking pins made after this date are thicker in diameter and of a tougher alloy; their rate of pin fracture is not known. The aim of this study was to better understand the impact of the design changes on the performance of MCGRs. Methods: This study involves 46 patients with 76 removed MCGRs. Forty-six rods were manufactured before March 26, 2015, and 30 rods after that date. Clinical and implant data were collected for all MCGRs. Retrieval analysis comprised plain radiographs evaluations, force and elongation testing, and disassembly. Results: The 2 patient groups were statistically comparable. We found that 14 of 27 patients implanted with rods manufactured before March 26, 2015 (group I) had a fracture of their locking pins. Three of the 17 patients with rods manufactured after this date (group II) were also found to have a fractured pin. Conclusions: Retrieved rods collected at our center and made after March 26, 2015, had far fewer locking pin fractures than those made before this date; this may be due to the change in pin design.
- Open Access
- 3 February 2023
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 43 (4) , 211-217
Rod Fracture in Magnetically Controlled Growing Spine Rods
Background: The mechanisms of fracture in magnetically controlled growing rods (MCGRs) and the risk factors associated with this are poorly understood. This retrospective analysis of explanted MCGRs aimed to add understanding to this subject. Methods: From our cohort of over 120 retrieved MCGRs, we identified 7 rods that had fractured; all were single-rod constructs, retrieved from 6 patients. These were examined and compared with 15 intact single-rod constructs. Retrieval and fractographic analyses were used to determine the failure mode at the fracture site and the implant's functionality. Cobb angle, degree of rod contouring, and the distance between anchoring points were computed on anteroposterior and lateral radiographs. Results: 5/7 versus 3/15 rods had been inserted after the removal of a previously inserted rod, in the fractured versus control groups. All fractured rods failed due to bending fatigue. Fractured rods had greater rod contouring angles in the frontal plane (P = 0.0407) and lateral plane (P = 0.0306), and greater distances between anchoring points in both anteroposterior and lateral planes (P = 0.0061 and P = 0.0074, respectively). Conclusions: We found all failed due to a fatigue fracture and were virtually all single rod configurations. Fracture initiation points corresponded with mechanical indentation marks induced by the intraoperative rod contouring tool. Fractured rods had undergone greater rod contouring and had greater distances between anchoring points, suggesting that it is preferable to implant double rod constructs in patients with sufficient spinal maturity to avoid this complication. Clinical Relevance: Level III.
- 3 February 2023
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 43 (4) , 211-217
Open AccessRod Fracture in Magnetically Controlled Growing Spine Rods
Background: The mechanisms of fracture in magnetically controlled growing rods (MCGRs) and the risk factors associated with this are poorly understood. This retrospective analysis of explanted MCGRs aimed to add understanding to this subject. Methods: From our cohort of over 120 retrieved MCGRs, we identified 7 rods that had fractured; all were single-rod constructs, retrieved from 6 patients. These were examined and compared with 15 intact single-rod constructs. Retrieval and fractographic analyses were used to determine the failure mode at the fracture site and the implant's functionality. Cobb angle, degree of rod contouring, and the distance between anchoring points were computed on anteroposterior and lateral radiographs. Results: 5/7 versus 3/15 rods had been inserted after the removal of a previously inserted rod, in the fractured versus control groups. All fractured rods failed due to bending fatigue. Fractured rods had greater rod contouring angles in the frontal plane (P = 0.0407) and lateral plane (P = 0.0306), and greater distances between anchoring points in both anteroposterior and lateral planes (P = 0.0061 and P = 0.0074, respectively). Conclusions: We found all failed due to a fatigue fracture and were virtually all single rod configurations. Fracture initiation points corresponded with mechanical indentation marks induced by the intraoperative rod contouring tool. Fractured rods had undergone greater rod contouring and had greater distances between anchoring points, suggesting that it is preferable to implant double rod constructs in patients with sufficient spinal maturity to avoid this complication. Clinical Relevance: Level III.
- Open Access
- 16 August 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-10
Blood titanium levels in patients with large and sliding titanium implants
Background: Titanium, which is known to be a highly biologically inert element, is one of the most commonly used metals in orthopaedic implants. While cobalt and chromium blood metal ion testing is routinely used in the clinical monitoring of patients with metal-on-metal hip implants, much less is known about the levels of titanium in patients with other implant types. The aim of this study was to better understand the normal ranges of blood titanium levels in patients implanted with large and sliding titanium constructs by comparison with reference levels from conventional titanium hips. Methods: This study examined data collected from 136 patients. Over a period of 24 months, whole blood samples were collected from 41 patients implanted with large titanium implants: long (range 15 to 30 cm) spine rods with a sliding mechanism (“spine rods”, n = 18), long bone tumour implants (“tumour implants”, n = 13) and 3D-printed customised massive acetabular defect implants (“massive acetabular implants”, n = 10). This data was compared with standard, uncemented primary titanium hip implants (“standard hips”, 15 cm long) (n = 95). Clinical, imaging and blood titanium levels data were collected for all patients and compared statistically between the different groups. Results: The median (range) of blood titanium levels of the standard hip, spine rods, femoral tumour implants and massive acetabular implants were 1.2 ppb (0.6–4.9), 9.7 ppb (4.0–25.4), 2.6 ppb (0.4–104.4) and 5.7 ppb (1.6–31.5) respectively. Spine rods and massive acetabular implants had significantly greater blood titanium levels compared to the standard hips group (p < 0.001). Conclusion: This study showed that titanium orthopaedic implants that are large and/or have a sliding mechanism have higher blood titanium levels compared to well-functioning, conventionally sized titanium hips. Reassuringly, the increased levels did not appear to induce adverse metal reactions. This study provides useful baseline data for future studies aimed at assessing blood titanium levels as a biomarker for implant function.
- 16 August 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-10
Open AccessBlood titanium levels in patients with large and sliding titanium implants
Background: Titanium, which is known to be a highly biologically inert element, is one of the most commonly used metals in orthopaedic implants. While cobalt and chromium blood metal ion testing is routinely used in the clinical monitoring of patients with metal-on-metal hip implants, much less is known about the levels of titanium in patients with other implant types. The aim of this study was to better understand the normal ranges of blood titanium levels in patients implanted with large and sliding titanium constructs by comparison with reference levels from conventional titanium hips. Methods: This study examined data collected from 136 patients. Over a period of 24 months, whole blood samples were collected from 41 patients implanted with large titanium implants: long (range 15 to 30 cm) spine rods with a sliding mechanism (“spine rods”, n = 18), long bone tumour implants (“tumour implants”, n = 13) and 3D-printed customised massive acetabular defect implants (“massive acetabular implants”, n = 10). This data was compared with standard, uncemented primary titanium hip implants (“standard hips”, 15 cm long) (n = 95). Clinical, imaging and blood titanium levels data were collected for all patients and compared statistically between the different groups. Results: The median (range) of blood titanium levels of the standard hip, spine rods, femoral tumour implants and massive acetabular implants were 1.2 ppb (0.6–4.9), 9.7 ppb (4.0–25.4), 2.6 ppb (0.4–104.4) and 5.7 ppb (1.6–31.5) respectively. Spine rods and massive acetabular implants had significantly greater blood titanium levels compared to the standard hips group (p < 0.001). Conclusion: This study showed that titanium orthopaedic implants that are large and/or have a sliding mechanism have higher blood titanium levels compared to well-functioning, conventionally sized titanium hips. Reassuringly, the increased levels did not appear to induce adverse metal reactions. This study provides useful baseline data for future studies aimed at assessing blood titanium levels as a biomarker for implant function.
- Open Access
- 21 April 2022
- Published by SAGE Publications in Global Spine Journal
- Vol. 14 (1) , 122-129
The Performance of MAGEC X Spine Rods: A Comparative Retrieval Study
Study Design: Multicentre comparative analysis of explanted Spine Magnetically Controlled Growing Rods (MCGRs). Objectives: MAGEC X, the latest commercially available generation, was recalled in 2020 due to the risk of post-implantation separation of an actuator end-cap component. Currently, the supply of all MAGEC rods was temporarily suspended in the UK and the EU. Objective of this study is to compare the performance of the MAGEC X MCGR to the earlier MAGEC 1.3 design iteration, by means of retrieval analysis. Methods: Fifteen of both MAGEC X and MAGEC 1.3 rods were consecutively collected from five different hospitals following removal surgery and matched by time to removal. Clinical and implant data was collected for all MCGRs. Analysis comprised visual assessments of external damage, plain radiograph evaluations, force and elongation testing, MAGEC X end-cap torque testing and disassembly. Mann-Whitney U tests were used to statistically compare groups. Results: Rod distraction reached in vivo was significantly higher in the MAGEC 1.3 ( P = .002). There was no statistically significant difference in the total external damage score ( P = .870), maximum force produced ( P = .695) or distraction reached during force test ( P = .880). No pin fracture was detected. Elongation of stroke was mildly higher ( P = .051) for the MAGEC X implants. One MAGEC X had evident end cap component loosening. Internal damage scores were mildly lower in the MAGEC X group. Conclusion: MAGEC X showed similar performance results than the previous design iteration MAGEC 1.3. End-cap component loosening was observed, with no major consequences on the internal mechanism.
- 21 April 2022
- Published by SAGE Publications in Global Spine Journal
- Vol. 14 (1) , 122-129
Open AccessThe Performance of MAGEC X Spine Rods: A Comparative Retrieval Study
Study Design: Multicentre comparative analysis of explanted Spine Magnetically Controlled Growing Rods (MCGRs). Objectives: MAGEC X, the latest commercially available generation, was recalled in 2020 due to the risk of post-implantation separation of an actuator end-cap component. Currently, the supply of all MAGEC rods was temporarily suspended in the UK and the EU. Objective of this study is to compare the performance of the MAGEC X MCGR to the earlier MAGEC 1.3 design iteration, by means of retrieval analysis. Methods: Fifteen of both MAGEC X and MAGEC 1.3 rods were consecutively collected from five different hospitals following removal surgery and matched by time to removal. Clinical and implant data was collected for all MCGRs. Analysis comprised visual assessments of external damage, plain radiograph evaluations, force and elongation testing, MAGEC X end-cap torque testing and disassembly. Mann-Whitney U tests were used to statistically compare groups. Results: Rod distraction reached in vivo was significantly higher in the MAGEC 1.3 ( P = .002). There was no statistically significant difference in the total external damage score ( P = .870), maximum force produced ( P = .695) or distraction reached during force test ( P = .880). No pin fracture was detected. Elongation of stroke was mildly higher ( P = .051) for the MAGEC X implants. One MAGEC X had evident end cap component loosening. Internal damage scores were mildly lower in the MAGEC X group. Conclusion: MAGEC X showed similar performance results than the previous design iteration MAGEC 1.3. End-cap component loosening was observed, with no major consequences on the internal mechanism.
- Open Access
- 5 March 2021
- Published by Springer Nature in European Spine Journal
- Vol. 30 (7) , 1799-1812
Understanding the implant performance of magnetically controlled growing spine rods: a review article
Purpose: Early-Onset Scoliosis (EOS) (defined as a curvature of the spine ≥ 10° with onset before 10 years of age) if not properly treated, can lead to increased morbidity and mortality. Traditionally Growing Rods (TGRs), implants fixated to the spine and extended every 6–8 months by surgery, are considered the gold standard, but Magnetically Controlled Growing Rods (MCGRs) avoid multiple surgeries. While the potential benefit of outpatient distraction procedure with MCGR is huge, concerns still remain about its risks, up to the release of a Medical Device Alert (MDA) by the Medicines and Healthcare Regulatory Agency (MHRA) advising not to implant MCGRs until further notice. The aim of this literature review is to (1) give an overview on the use of MCGRs and (2) identify what is currently understood about the surgical, implant and patient factors associated with the use of MCGRs. Methods: Systematic literature review. Results: Surgical factors such as use of single rod configuration or incorrect rod contouring might affect early failure of MCGRs. Patient’s older age and higher BMI are correlated with rod slippage. Wear debris and distraction mechanism failure may result from implant design and iteration. Conclusion: Despite the complications reported, this technology still offers one of the best solutions to spine surgeons dealing with severe EOS. Lowering the complication rate by identifying risk factors for failure is possible and further studies in this direction are required. Once the risk factors are well described, some of these can be addressed enabling a safer use of MCGRs.
- 5 March 2021
- Published by Springer Nature in European Spine Journal
- Vol. 30 (7) , 1799-1812
Open AccessUnderstanding the implant performance of magnetically controlled growing spine rods: a review article
Purpose: Early-Onset Scoliosis (EOS) (defined as a curvature of the spine ≥ 10° with onset before 10 years of age) if not properly treated, can lead to increased morbidity and mortality. Traditionally Growing Rods (TGRs), implants fixated to the spine and extended every 6–8 months by surgery, are considered the gold standard, but Magnetically Controlled Growing Rods (MCGRs) avoid multiple surgeries. While the potential benefit of outpatient distraction procedure with MCGR is huge, concerns still remain about its risks, up to the release of a Medical Device Alert (MDA) by the Medicines and Healthcare Regulatory Agency (MHRA) advising not to implant MCGRs until further notice. The aim of this literature review is to (1) give an overview on the use of MCGRs and (2) identify what is currently understood about the surgical, implant and patient factors associated with the use of MCGRs. Methods: Systematic literature review. Results: Surgical factors such as use of single rod configuration or incorrect rod contouring might affect early failure of MCGRs. Patient’s older age and higher BMI are correlated with rod slippage. Wear debris and distraction mechanism failure may result from implant design and iteration. Conclusion: Despite the complications reported, this technology still offers one of the best solutions to spine surgeons dealing with severe EOS. Lowering the complication rate by identifying risk factors for failure is possible and further studies in this direction are required. Once the risk factors are well described, some of these can be addressed enabling a safer use of MCGRs.