Elena Carlotto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elena Carlotto has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
- Pietro Canzi
Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy
12 shared publications - Marco Benazzo
UOC Othorynolaringology, Fondazione IRCCS Policlinico San Matteo, Via Camillo Golgi 19, 27100 Pavia, Italy
7 shared publications - Luca Bruschini
Otolaryngology, Audiology, and Phoniatrics Unit, University of Pisa, Pisa, Italy
5 shared publications - Cesare Chiapperini
Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy
4 shared publications - Francesco Lazzerini
Otolaryngology, Audiology, and Phoniatrics Unit, University of Pisa, 56127 Pisa, Italy
4 shared publications - Ilaria Ottoboni
Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy
4 shared publications
Latest Publications
- Open Access
- 12 November 2026
- Published by MDPI AG in Audiology Research
- Vol. 16 (6) , 174
What Radiomics Teaches Us About Vestibular Schwannoma Biology: Imaging Biomarkers, Artificial Intelligence, and Future Clinical Translation: A Narrative Review
Background/Objective: Vestibular schwannoma is a benign Schwann cell tumor characterized by marked biological and clinical heterogeneity, resulting in highly variable growth patterns, hearing outcomes and treatment responses. Advances in molecular biology have improved the understanding of the pathways driving tumor development, highlighting the roles of NF2-related signaling, angiogenesis, inflammation and tumor-microenvironment interactions. In parallel, quantitative imaging, radiomics, and artificial intelligence (AI) are being investigated for tumor characterization and outcome prediction, although the biological specificity of many imaging-derived features remains unproven. Methods: This narrative review was conducted by examining recent literature on the role of radiomics in Vestibular schwannoma biology. Results: Across published studies reviewed we summarize the current knowledge on vestibular schwannoma biology and discusses the clinical potential of quantitative MRI, volumetric analysis, radiomics and AI for tumor characterization, growth prediction, treatment-response assessment, automated segmentation and functional outcome prediction. Conclusions: Particular emphasis is placed on distinguishing reported predictive associations from validated biological correlates and on the potential value of integrating imaging with molecular data. Finally, current limitations, including methodological heterogeneity, lack of standardization and the need for multicenter validation, are discussed to outline future directions for clinical translation.
- 12 November 2026
- Published by MDPI AG in Audiology Research
- Vol. 16 (6) , 174
Open AccessWhat Radiomics Teaches Us About Vestibular Schwannoma Biology: Imaging Biomarkers, Artificial Intelligence, and Future Clinical Translation: A Narrative Review
Background/Objective: Vestibular schwannoma is a benign Schwann cell tumor characterized by marked biological and clinical heterogeneity, resulting in highly variable growth patterns, hearing outcomes and treatment responses. Advances in molecular biology have improved the understanding of the pathways driving tumor development, highlighting the roles of NF2-related signaling, angiogenesis, inflammation and tumor-microenvironment interactions. In parallel, quantitative imaging, radiomics, and artificial intelligence (AI) are being investigated for tumor characterization and outcome prediction, although the biological specificity of many imaging-derived features remains unproven. Methods: This narrative review was conducted by examining recent literature on the role of radiomics in Vestibular schwannoma biology. Results: Across published studies reviewed we summarize the current knowledge on vestibular schwannoma biology and discusses the clinical potential of quantitative MRI, volumetric analysis, radiomics and AI for tumor characterization, growth prediction, treatment-response assessment, automated segmentation and functional outcome prediction. Conclusions: Particular emphasis is placed on distinguishing reported predictive associations from validated biological correlates and on the potential value of integrating imaging with molecular data. Finally, current limitations, including methodological heterogeneity, lack of standardization and the need for multicenter validation, are discussed to outline future directions for clinical translation.
- Open Access
- 28 August 2026
- Published by MDPI AG in Pharmaceutics
- Vol. 18 (9) , 1084
Toward 4D Biomaterials: Comparing Electrospun and 3D-Printed Shape-Memory Scaffolds
Background/Objectives: Shape-memory biodegradable scaffolds (4D scaffolds) represent promising platforms for minimally invasive tissue engineering and localized drug delivery. This study investigated how two different fabrication techniques, electrospinning (ES) and extrusion-based direct ink writing (DIW), influence the structural, thermal, mechanical, shape-memory, and drug-release properties of poly(L-lactide-co-caprolactone) (PLA/PCL 70:30) scaffolds loaded with dexamethasone (DXM). Methods: DXM-loaded PLA/PCL 70:30 scaffolds were fabricated by ES and DIW. The resulting matrices were characterized in terms of morphology, mass, thickness, drug-loading efficiency, thermal properties by differential scanning calorimetry, shape-memory performance, tensile mechanical properties, and in vitro DXM release. Results: Both fabrication techniques produced DXM-loaded matrices with comparable mass and thickness and high loading efficiencies (>82%). Glass transition temperatures ranged between 33 and 39 °C, supporting thermally induced shape recovery under physiologically relevant conditions, while ES processing was associated with higher polymer crystallinity. All scaffolds exhibited shape-memory behavior, with recovery ratios exceeding 90%. ES scaffolds displayed a microporous nanofibrous architecture, whereas DIW scaffolds showed a more open and highly porous structure. These morphological differences were reflected in their mechanical behavior: ES scaffolds exhibited higher tensile strength (up to 16.5 MPa vs. 1.9 MPa) and elongation at break (up to 320% vs. 243%). Drug-release profiles were also fabrication-dependent, with ES scaffolds reaching a plateau at approximately 80% DXM release, whereas DIW scaffolds showed near-complete release within 48 h. Conclusions: Both fabrication approaches preserved the thermoresponsive shape-memory behavior of PLA/PCL 70:30 but generated distinct scaffold architectures that strongly influenced mechanical performance and DXM-release kinetics.
- 28 August 2026
- Published by MDPI AG in Pharmaceutics
- Vol. 18 (9) , 1084
Open AccessToward 4D Biomaterials: Comparing Electrospun and 3D-Printed Shape-Memory Scaffolds
Background/Objectives: Shape-memory biodegradable scaffolds (4D scaffolds) represent promising platforms for minimally invasive tissue engineering and localized drug delivery. This study investigated how two different fabrication techniques, electrospinning (ES) and extrusion-based direct ink writing (DIW), influence the structural, thermal, mechanical, shape-memory, and drug-release properties of poly(L-lactide-co-caprolactone) (PLA/PCL 70:30) scaffolds loaded with dexamethasone (DXM). Methods: DXM-loaded PLA/PCL 70:30 scaffolds were fabricated by ES and DIW. The resulting matrices were characterized in terms of morphology, mass, thickness, drug-loading efficiency, thermal properties by differential scanning calorimetry, shape-memory performance, tensile mechanical properties, and in vitro DXM release. Results: Both fabrication techniques produced DXM-loaded matrices with comparable mass and thickness and high loading efficiencies (>82%). Glass transition temperatures ranged between 33 and 39 °C, supporting thermally induced shape recovery under physiologically relevant conditions, while ES processing was associated with higher polymer crystallinity. All scaffolds exhibited shape-memory behavior, with recovery ratios exceeding 90%. ES scaffolds displayed a microporous nanofibrous architecture, whereas DIW scaffolds showed a more open and highly porous structure. These morphological differences were reflected in their mechanical behavior: ES scaffolds exhibited higher tensile strength (up to 16.5 MPa vs. 1.9 MPa) and elongation at break (up to 320% vs. 243%). Drug-release profiles were also fabrication-dependent, with ES scaffolds reaching a plateau at approximately 80% DXM release, whereas DIW scaffolds showed near-complete release within 48 h. Conclusions: Both fabrication approaches preserved the thermoresponsive shape-memory behavior of PLA/PCL 70:30 but generated distinct scaffold architectures that strongly influenced mechanical performance and DXM-release kinetics.
- Open Access
- 29 April 2026
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 22 (2) , 1-3
Bilateral Idiopathic Sequential Neuritis: Case Report and Literature Review
Bilateral sequential vestibular neuritis is a rare condition reported in literature involving the vestibular nerve sequentially. Nowadays, the video head impulse test (vHIT) and vestibular-evoked myogenic potentials provide specific patterns of reduced vestibulo-ocular reflex (VOR) that allow differentiation between complete and partial nerve involvement. These tests are essential in cases of bilateral vestibular loss to monitor vestibular compensation. The case of a 56-year-old man who presented to a tertiary vestibular center with acute left-sided vestibular loss, following a documented contralateral acute vestibular loss 4 years earlier. To the best of current knowledge, this report presents, for the first time in the literature, vHIT in Suppression Head Impulse Paradigm modality data as an expression of compensation. A review of the literature was also performed according to PRISMA statements.
- 29 April 2026
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 22 (2) , 1-3
Open AccessBilateral Idiopathic Sequential Neuritis: Case Report and Literature Review
Bilateral sequential vestibular neuritis is a rare condition reported in literature involving the vestibular nerve sequentially. Nowadays, the video head impulse test (vHIT) and vestibular-evoked myogenic potentials provide specific patterns of reduced vestibulo-ocular reflex (VOR) that allow differentiation between complete and partial nerve involvement. These tests are essential in cases of bilateral vestibular loss to monitor vestibular compensation. The case of a 56-year-old man who presented to a tertiary vestibular center with acute left-sided vestibular loss, following a documented contralateral acute vestibular loss 4 years earlier. To the best of current knowledge, this report presents, for the first time in the literature, vHIT in Suppression Head Impulse Paradigm modality data as an expression of compensation. A review of the literature was also performed according to PRISMA statements.
- Open Access
Models for Training in Pediatric Otologic Surgery: A Systematic Review
Background/Objectives: Temporal bone surgery in children is technically challenging due to their smaller anatomical structures, developmental differences, and the closer proximity of critical neurovascular structures. The limited availability of conventional training materials and pediatric cadaveric specimens has led to greater enthusiasm for simulation-based methods. The aim of this systematic review was to identify existing otologic simulation models and evaluate their anatomical accuracy, teaching effectiveness, and supporting evidence. Methods: In accordance with PRISMA guidelines, the PubMed, Embase, Scopus, and Cochrane Library databases were searched for studies reporting simulation tools for pediatric otologic surgery. Articles describing three-dimensional printed (3DP) models, virtual reality (VR) platforms, cadaver specimens, and animal models were included. Studies focusing on children and providing educational outcomes were selected. The extracted data were synthetized and analytically discussed. Results: Thirteen studies met the inclusion criteria: nine on 3DP models and four on VR environments. No research involving cadavers or animals was identified. 3DP models exhibited consistent anatomical accuracy and notable educational advantages. Five studies used surveys for their evaluations, and three relied on expert observer assessments. The studies including validation analyses showed a high correlation between printed models and computed tomography (CT) images. VR systems supported anatomical reconstruction and segmentation tasks, as well as guided simulation exercises. However, most of the research consisted of feasibility studies with limited participant groups. Conclusions: Simulation-based training with 3DP and VR models could be ethical and accurate methods for obtaining relevant skills in pediatric otologic surgery. The reviewed data suggest that these tools may be suitable as a first-line step within an integrated, multimodal training pathway prior to direct patient contact.
Open AccessModels for Training in Pediatric Otologic Surgery: A Systematic Review
Background/Objectives: Temporal bone surgery in children is technically challenging due to their smaller anatomical structures, developmental differences, and the closer proximity of critical neurovascular structures. The limited availability of conventional training materials and pediatric cadaveric specimens has led to greater enthusiasm for simulation-based methods. The aim of this systematic review was to identify existing otologic simulation models and evaluate their anatomical accuracy, teaching effectiveness, and supporting evidence. Methods: In accordance with PRISMA guidelines, the PubMed, Embase, Scopus, and Cochrane Library databases were searched for studies reporting simulation tools for pediatric otologic surgery. Articles describing three-dimensional printed (3DP) models, virtual reality (VR) platforms, cadaver specimens, and animal models were included. Studies focusing on children and providing educational outcomes were selected. The extracted data were synthetized and analytically discussed. Results: Thirteen studies met the inclusion criteria: nine on 3DP models and four on VR environments. No research involving cadavers or animals was identified. 3DP models exhibited consistent anatomical accuracy and notable educational advantages. Five studies used surveys for their evaluations, and three relied on expert observer assessments. The studies including validation analyses showed a high correlation between printed models and computed tomography (CT) images. VR systems supported anatomical reconstruction and segmentation tasks, as well as guided simulation exercises. However, most of the research consisted of feasibility studies with limited participant groups. Conclusions: Simulation-based training with 3DP and VR models could be ethical and accurate methods for obtaining relevant skills in pediatric otologic surgery. The reviewed data suggest that these tools may be suitable as a first-line step within an integrated, multimodal training pathway prior to direct patient contact.
- Open Access
- 2 December 2024
- Published by MDPI AG in Audiology Research
- Vol. 14 (6) , 1045-1057
A 3D-Printed Educational Model for First-Line Management of BPPV in Emergency Departments
Background: We present a feasibility study on the development of a 3D-printed (3DP) model of benign paroxysmal positional vertigo (BPPV) and its validation as an educational tool for training in therapeutic maneuvers. Methods: A 1.5:1 3DP model of the human labyrinth, supplemented by a 1:1 3DP model of the skull, was obtained from a computed tomography scan. We presented the model to 15 Emergency Medicine residents, 15 medical students, 15 Otolaryngology residents, and 15 Otolaryngology practitioners from two academic referral centers. Participants performed the Semont and Epley maneuvers on the model twice, once before and once after observing the biomechanics of BPPV using this tool. A specific survey was then administered to assess both performance improvement and satisfaction. Results: All the trainees demonstrated an improving trend on the second attempt. The medical students ameliorated significantly after the training in both Epley (p = 0.007) and Semont maneuvers (p = 0.0134). The Emergency Medicine residents improved significantly in Semont maneuvers (p = 0.0134). Self-reported understanding of the BPPV mechanics improved significantly after training in all the groups (p < 0.05). Conclusions: The preliminary data highlighted the potential benefits of training on the 3DP model for practitioners involved in the first-line management of BPPV.
- 2 December 2024
- Published by MDPI AG in Audiology Research
- Vol. 14 (6) , 1045-1057
Open AccessA 3D-Printed Educational Model for First-Line Management of BPPV in Emergency Departments
Background: We present a feasibility study on the development of a 3D-printed (3DP) model of benign paroxysmal positional vertigo (BPPV) and its validation as an educational tool for training in therapeutic maneuvers. Methods: A 1.5:1 3DP model of the human labyrinth, supplemented by a 1:1 3DP model of the skull, was obtained from a computed tomography scan. We presented the model to 15 Emergency Medicine residents, 15 medical students, 15 Otolaryngology residents, and 15 Otolaryngology practitioners from two academic referral centers. Participants performed the Semont and Epley maneuvers on the model twice, once before and once after observing the biomechanics of BPPV using this tool. A specific survey was then administered to assess both performance improvement and satisfaction. Results: All the trainees demonstrated an improving trend on the second attempt. The medical students ameliorated significantly after the training in both Epley (p = 0.007) and Semont maneuvers (p = 0.0134). The Emergency Medicine residents improved significantly in Semont maneuvers (p = 0.0134). Self-reported understanding of the BPPV mechanics improved significantly after training in all the groups (p < 0.05). Conclusions: The preliminary data highlighted the potential benefits of training on the 3DP model for practitioners involved in the first-line management of BPPV.
- Open Access
- 1 October 2024
- Published by Wolters Kluwer Health in Hearing Balance and Communication
- Vol. 22 (4) , 144-150
Focus on bimodal cochlear implant users: The advantages of a dedicated fitting formula
Aim: The aim is to evaluate the advantages of the dedicated Adaptive Phonak Digital Bimodal (APDB) fitting formula compared to the traditional National Acoustic Laboratories Non-Linear 2 (NAL-NL2) for contralateral hearing aid (HA) in bimodal cochlear implant (CI) users. Settings and Design: Cross-over bicentric study involving 10 adult bimodal Advanced Bionics CI users with usable contralateral hearing. Subjects and Methods: Participants were provided with a dedicated Naída Link Q90 HA. Speech recognition in noise was assessed with the Italian Matrix Sentence Test. The competing noise was presented at a fixed level of 55 dB HL. The speech level was changed adaptively to calculate the signal-to-noise ratio (SNR) targeting at a score of 50% correct words. Outcomes were compared in three configurations, with CI only, with APDB and with NAL-NL2. Subjective hearing benefit was assessed using the Speech, Spatial and Qualities of Hearing Scale (SSQ) questionnaire in both bimodal configurations. Results: Speech intelligibility in noise showed significantly better results for both bimodal configurations (P < 0.001) compared to CI only (mean 9.1 dB SNR ± 5.7) and for the APDB formula (mean 2.25 dB SNR ± 2.4) compared to NAL-NL2 (mean 3.3 dB SNR ± 2.7; P < 0.05). Responses to the SSQ demonstrated a trend for improvement with APDB compared to NAL2/NAL in the “space” subgroup and a statistically significant difference in favor of APDB for “other sound qualities” (P < 0.05). Conclusions: The APDB fitting formula has been shown to be beneficial for binaural bimodal CI users, both in speech intelligibility test results and subjective perception of hearing comfort.
- 1 October 2024
- Published by Wolters Kluwer Health in Hearing Balance and Communication
- Vol. 22 (4) , 144-150
Open AccessFocus on bimodal cochlear implant users: The advantages of a dedicated fitting formula
Aim: The aim is to evaluate the advantages of the dedicated Adaptive Phonak Digital Bimodal (APDB) fitting formula compared to the traditional National Acoustic Laboratories Non-Linear 2 (NAL-NL2) for contralateral hearing aid (HA) in bimodal cochlear implant (CI) users. Settings and Design: Cross-over bicentric study involving 10 adult bimodal Advanced Bionics CI users with usable contralateral hearing. Subjects and Methods: Participants were provided with a dedicated Naída Link Q90 HA. Speech recognition in noise was assessed with the Italian Matrix Sentence Test. The competing noise was presented at a fixed level of 55 dB HL. The speech level was changed adaptively to calculate the signal-to-noise ratio (SNR) targeting at a score of 50% correct words. Outcomes were compared in three configurations, with CI only, with APDB and with NAL-NL2. Subjective hearing benefit was assessed using the Speech, Spatial and Qualities of Hearing Scale (SSQ) questionnaire in both bimodal configurations. Results: Speech intelligibility in noise showed significantly better results for both bimodal configurations (P < 0.001) compared to CI only (mean 9.1 dB SNR ± 5.7) and for the APDB formula (mean 2.25 dB SNR ± 2.4) compared to NAL-NL2 (mean 3.3 dB SNR ± 2.7; P < 0.05). Responses to the SSQ demonstrated a trend for improvement with APDB compared to NAL2/NAL in the “space” subgroup and a statistically significant difference in favor of APDB for “other sound qualities” (P < 0.05). Conclusions: The APDB fitting formula has been shown to be beneficial for binaural bimodal CI users, both in speech intelligibility test results and subjective perception of hearing comfort.
- Open Access
- 26 September 2024
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 20 (5) , 462-465
Middle Ear Welding Injury: Case Report and Literature Review
Damage to the middle ear (ME) caused by penetrating welding sparks can lead to a variety of adverse outcomes. An exhaustive review of the literature is lacking, particularly with regard to clinical presentation, diagnostic-therapeutic work-up, and outcomes. Here we describe the clinical details of an injury caused by the largest welding foreign body ever reported in the ME. In addition, we present a comprehensive review of the relevant literature. Cite this article as: Bruno G, Carlotto C, Bramardi F, et al. Middle ear welding injury: case report and literature review. J Int Adv Otol. 2024;20(5): 462-465.
- 26 September 2024
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 20 (5) , 462-465
Open AccessMiddle Ear Welding Injury: Case Report and Literature Review
Damage to the middle ear (ME) caused by penetrating welding sparks can lead to a variety of adverse outcomes. An exhaustive review of the literature is lacking, particularly with regard to clinical presentation, diagnostic-therapeutic work-up, and outcomes. Here we describe the clinical details of an injury caused by the largest welding foreign body ever reported in the ME. In addition, we present a comprehensive review of the relevant literature. Cite this article as: Bruno G, Carlotto C, Bramardi F, et al. Middle ear welding injury: case report and literature review. J Int Adv Otol. 2024;20(5): 462-465.
- Open Access
- 26 April 2024
- Published by MDPI AG in Audiology Research
- Vol. 14 (3) , 401-411
Multi-Magnet Cochlear Implant Technology and Magnetic Resonance Imaging: The Safety Issue
Despite the spread of novel-generation cochlear-implant (CI) magnetic systems, access to magnetic resonance imaging (MRI) for CI recipients is still limited due to safety concerns. The aim of this study is to assess and record the experiences of Hires Ultra 3D (Advanced Bionics) recipients who underwent an MRI examination. A multicentric European survey about this topic was conducted focusing on safety issues, and the results were compared with the current literature. We collected a total of 65 MRI scans performed in 9 otologic referral centers for a total of 47 Hires Ultra 3D recipients, including, for the first time, 2 children and 3 teenagers. Preventive measures were represented by scanning time and sedation for children. Head wrapping was used in eight cases, and six of the eight cases received local anesthesia, even if both measures were not needed. Only three patients complained of pain (3/65 examinations, 4.6%) due to the tight head bandage, and one of the three cases required MRI scan interruption. No other adverse events were reported. We believe that these results should encourage MRI execution in accordance with manufacturer recommendations for Ultra 3D recipients.
- 26 April 2024
- Published by MDPI AG in Audiology Research
- Vol. 14 (3) , 401-411
Open AccessMulti-Magnet Cochlear Implant Technology and Magnetic Resonance Imaging: The Safety Issue
Despite the spread of novel-generation cochlear-implant (CI) magnetic systems, access to magnetic resonance imaging (MRI) for CI recipients is still limited due to safety concerns. The aim of this study is to assess and record the experiences of Hires Ultra 3D (Advanced Bionics) recipients who underwent an MRI examination. A multicentric European survey about this topic was conducted focusing on safety issues, and the results were compared with the current literature. We collected a total of 65 MRI scans performed in 9 otologic referral centers for a total of 47 Hires Ultra 3D recipients, including, for the first time, 2 children and 3 teenagers. Preventive measures were represented by scanning time and sedation for children. Head wrapping was used in eight cases, and six of the eight cases received local anesthesia, even if both measures were not needed. Only three patients complained of pain (3/65 examinations, 4.6%) due to the tight head bandage, and one of the three cases required MRI scan interruption. No other adverse events were reported. We believe that these results should encourage MRI execution in accordance with manufacturer recommendations for Ultra 3D recipients.
- Open Access
- 29 March 2024
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 20 (2) , 186-188
Intratympanic Gentamicin Injection for Endolymphatic Hydrops After Cochlear Implantation
Endolymphatic hydrops has been documented as a possible complication of cochlear implantation; however, few studies have addressed its treatment. We describe the first case ever reported of delayed endolymphatic hydrops after a cochlear implant successfully treated with intratympanic gentamicin injection. A detailed discussion of this case with a focus on its management and outcomes will be provided in comparison with literature data. The intratympanic gentamicin injection has been demonstrated to be an effective treatment for symptomatic endolymphatic hydrops after cochlear implantation. We advocate further studies to validate this strategy as a promising alternative to surgical labyrinthectomy. Cite this article as: Canzi P, Carlotto E, Quaglieri S, et al. Intratympanic gentamicin injection for endolymphatic hydrops after cochlear implantation. J Int Adv Otol. 2024;20(2):186-188.
- 29 March 2024
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 20 (2) , 186-188
Open AccessIntratympanic Gentamicin Injection for Endolymphatic Hydrops After Cochlear Implantation
Endolymphatic hydrops has been documented as a possible complication of cochlear implantation; however, few studies have addressed its treatment. We describe the first case ever reported of delayed endolymphatic hydrops after a cochlear implant successfully treated with intratympanic gentamicin injection. A detailed discussion of this case with a focus on its management and outcomes will be provided in comparison with literature data. The intratympanic gentamicin injection has been demonstrated to be an effective treatment for symptomatic endolymphatic hydrops after cochlear implantation. We advocate further studies to validate this strategy as a promising alternative to surgical labyrinthectomy. Cite this article as: Canzi P, Carlotto E, Quaglieri S, et al. Intratympanic gentamicin injection for endolymphatic hydrops after cochlear implantation. J Int Adv Otol. 2024;20(2):186-188.
- 3 March 2024
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 25 (2) , 165-170
Pneumatocoele after cochlear implantation with lateral petrosectomy: A minor complication?
To illustrate the clinical features and management of pneumatocoele presenting with a trap-valve mechanism after cochlear implantation with lateral petrosectomy (LP) in comparison with literature. Pneumatocoele is a rare complication of cochlear implant (CI) surgery, generally managed with conservative treatments. We describe a progressively increasing pneumatocoele with a trap-valve mechanism occurring one year after CI with LP, successfully managed with revision surgery. Literature review was performed on this topic. Our case was the second ever reported in literature. It appeared consequently to forceful nose-blowing in a patient with refractory nasal polyposis. Unlike the pneumatocoeles reported after standard CI, we advised revision surgery as well as in the case of pneumatocoele after staged LP and CI. In both the patients subcutaneous air collection occurred as a late complication and an insufficient Eustachian tube closure was disclosed, which is considered a complication of LP itself. Surgical management was necessary in consideration of the risk of ascending infections associated with Eustachian tube patency in LP with CI. We consider surgical treatment mandatory in pneumatocoele after CI with LP, it is indeed the sentinel of the restoration of Eustachian tube patency and the potential prelude to major complications.
- 3 March 2024
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 25 (2) , 165-170
Pneumatocoele after cochlear implantation with lateral petrosectomy: A minor complication?
To illustrate the clinical features and management of pneumatocoele presenting with a trap-valve mechanism after cochlear implantation with lateral petrosectomy (LP) in comparison with literature. Pneumatocoele is a rare complication of cochlear implant (CI) surgery, generally managed with conservative treatments. We describe a progressively increasing pneumatocoele with a trap-valve mechanism occurring one year after CI with LP, successfully managed with revision surgery. Literature review was performed on this topic. Our case was the second ever reported in literature. It appeared consequently to forceful nose-blowing in a patient with refractory nasal polyposis. Unlike the pneumatocoeles reported after standard CI, we advised revision surgery as well as in the case of pneumatocoele after staged LP and CI. In both the patients subcutaneous air collection occurred as a late complication and an insufficient Eustachian tube closure was disclosed, which is considered a complication of LP itself. Surgical management was necessary in consideration of the risk of ascending infections associated with Eustachian tube patency in LP with CI. We consider surgical treatment mandatory in pneumatocoele after CI with LP, it is indeed the sentinel of the restoration of Eustachian tube patency and the potential prelude to major complications.