Roman Schmidt
Research Subjects
Roman Schmidt has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Stefan W. Hell
Department of Optical Nanoscopy, Max Planck Institute for Medical Research, Heidelberg, Germany
5 shared publications - Christian A. Wurm
Abberior Instruments, Hans-Adolf-Krebs-Weg 1, 37077 Göttingen, Germany
2 shared publications - Francisco Balzarotti
Department of NanoBiophotonics, Max Planck Institute for Biophysical Chemistry, 37077 Göttingen, Germany
2 shared publications - Isabelle Jansen
Abberior Instruments GmbH, Göttingen, Germany
2 shared publications - Jan Ellenberg
Cell Biology and Biophysics Unit, European Molecular Biology Laboratory, Heidelberg, Germany
2 shared publications - Jonas Ries
Max Perutz Labs, University of Vienna, Dr. Bohr-Gasse 9, 1030, Vienna, Austria
2 shared publications
Latest Publications
- Open Access
Localization accuracy in single-molecule fluorescence microscopy
The two prevalent methods to determine the position of individual fluorophores in the focal plane of a microscope rely either on the centroid of the fluorescence pattern produced by the fluorophore on a camera or on targeting the fluorophore’s coordinate with a spatially controlled illumination minimum, as realized in MINFLUX. In both methods, (sub)nanometer localization precisions have been reached, but little is known about their accuracy, i.e., the deviation of the obtained coordinate from its ground truth. Here we report a theoretical and experimental comparison of the accuracy provided by these two strategies. We quantify substantial systematic errors in camera-based localization due to the interplay of two difficult-to-control parameters: the orientation of the fluorophore in space and its axial deviation from the focal plane (defocus). For example, within an axial range of ±120 nm around the focus, the median distance between two fluorophores on a nanobody measured by camera-based localization varies by 26.5 nm. Under the same conditions, a commercial MINFLUX system yields a median variation in distance of 1.4 nm, indicating an improvement in accuracy by an order of magnitude. The accuracy of MINFLUX localization can be further improved to (sub-)ångström levels by reducing the average distance between the coordinates targeted by the illumination minimum and the fluorophore. As it delivers unrivaled precision and accuracy for mapping fluorophores and their distances, we consider coordinate-targeted localization essential for studying labeled cells at the sub-10 nm level and for exploring structural and conformational changes of labeled biomolecules.
Open AccessLocalization accuracy in single-molecule fluorescence microscopy
The two prevalent methods to determine the position of individual fluorophores in the focal plane of a microscope rely either on the centroid of the fluorescence pattern produced by the fluorophore on a camera or on targeting the fluorophore’s coordinate with a spatially controlled illumination minimum, as realized in MINFLUX. In both methods, (sub)nanometer localization precisions have been reached, but little is known about their accuracy, i.e., the deviation of the obtained coordinate from its ground truth. Here we report a theoretical and experimental comparison of the accuracy provided by these two strategies. We quantify substantial systematic errors in camera-based localization due to the interplay of two difficult-to-control parameters: the orientation of the fluorophore in space and its axial deviation from the focal plane (defocus). For example, within an axial range of ±120 nm around the focus, the median distance between two fluorophores on a nanobody measured by camera-based localization varies by 26.5 nm. Under the same conditions, a commercial MINFLUX system yields a median variation in distance of 1.4 nm, indicating an improvement in accuracy by an order of magnitude. The accuracy of MINFLUX localization can be further improved to (sub-)ångström levels by reducing the average distance between the coordinates targeted by the illumination minimum and the fluorophore. As it delivers unrivaled precision and accuracy for mapping fluorophores and their distances, we consider coordinate-targeted localization essential for studying labeled cells at the sub-10 nm level and for exploring structural and conformational changes of labeled biomolecules.
- 15 December 2022
- Published by Springer Nature in Nature Methods
- Vol. 20 (1) , 52-54
Reply to: Assessment of 3D MINFLUX data for quantitative structural biology in cells
- 15 December 2022
- Published by Springer Nature in Nature Methods
- Vol. 20 (1) , 52-54
Reply to: Assessment of 3D MINFLUX data for quantitative structural biology in cells
- Open Access
- 15 July 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (28) , eabl7560
Resolving the molecular architecture of the photoreceptor active zone with 3D-MINFLUX
Cells assemble macromolecular complexes into scaffoldings that serve as substrates for catalytic processes. Years of molecular neurobiology research indicate that neurotransmission depends on such optimization strategies. However, the molecular topography of the presynaptic active zone (AZ), where transmitter is released upon synaptic vesicle (SV) fusion, remains to be visualized. Therefore, we implemented MINFLUX optical nanoscopy to resolve the AZ of rod photoreceptors. This was facilitated by a novel sample immobilization technique that we name heat-assisted rapid dehydration (HARD), wherein a thin layer of rod synaptic terminals (spherules) was transferred onto glass coverslips from fresh retinal slices. Rod ribbon AZs were readily immunolabeled and imaged in 3D with a precision of a few nanometers. Our 3D-MINFLUX results indicate that the SV release site in rods is a molecular complex of bassoon–RIM2–ubMunc13-2–Ca v 1.4, which repeats longitudinally on both sides of the ribbon.
- 15 July 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (28) , eabl7560
Open AccessResolving the molecular architecture of the photoreceptor active zone with 3D-MINFLUX
Cells assemble macromolecular complexes into scaffoldings that serve as substrates for catalytic processes. Years of molecular neurobiology research indicate that neurotransmission depends on such optimization strategies. However, the molecular topography of the presynaptic active zone (AZ), where transmitter is released upon synaptic vesicle (SV) fusion, remains to be visualized. Therefore, we implemented MINFLUX optical nanoscopy to resolve the AZ of rod photoreceptors. This was facilitated by a novel sample immobilization technique that we name heat-assisted rapid dehydration (HARD), wherein a thin layer of rod synaptic terminals (spherules) was transferred onto glass coverslips from fresh retinal slices. Rod ribbon AZs were readily immunolabeled and imaged in 3D with a precision of a few nanometers. Our 3D-MINFLUX results indicate that the SV release site in rods is a molecular complex of bassoon–RIM2–ubMunc13-2–Ca v 1.4, which repeats longitudinally on both sides of the ribbon.
- Open Access
Assessment of 3D MINFLUX data for quantitative structural biology in cells revisited
Prakash and Curd provide a re-analysis 1 of individual datasets taken from our report 2 demonstrating MINFLUX 3D imaging in cells. Their evaluation confirms the unique localization precision provided by MINFLUX 2,3 featuring a standard deviation of σ = 1-3 nm. We appreciate their confirmation and also welcome the opportunity to clarify their remaining points. The hitherto almost unconceivable 3D localization precision attained by MINFLUX is likely to hold the key to an all-optical dynamical structural biology.
Open AccessAssessment of 3D MINFLUX data for quantitative structural biology in cells revisited
Prakash and Curd provide a re-analysis 1 of individual datasets taken from our report 2 demonstrating MINFLUX 3D imaging in cells. Their evaluation confirms the unique localization precision provided by MINFLUX 2,3 featuring a standard deviation of σ = 1-3 nm. We appreciate their confirmation and also welcome the opportunity to clarify their remaining points. The hitherto almost unconceivable 3D localization precision attained by MINFLUX is likely to hold the key to an all-optical dynamical structural biology.
- Top Cited PapersOpen Access
- 5 March 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-12
MINFLUX nanometer-scale 3D imaging and microsecond-range tracking on a common fluorescence microscope
The recently introduced minimal photon fluxes (MINFLUX) concept pushed the resolution of fluorescence microscopy to molecular dimensions. Initial demonstrations relied on custom made, specialized microscopes, raising the question of the method’s general availability. Here, we show that MINFLUX implemented with a standard microscope stand can attain 1–3 nm resolution in three dimensions, rendering fluorescence microscopy with molecule-scale resolution widely applicable. Advances, such as synchronized electro-optical and galvanometric beam steering and a stabilization that locks the sample position to sub-nanometer precision with respect to the stand, ensure nanometer-precise and accurate real-time localization of individually activated fluorophores. In our MINFLUX imaging of cell- and neurobiological samples, ~800 detected photons suffice to attain a localization precision of 2.2 nm, whereas ~2500 photons yield precisions <1 nm (standard deviation). We further demonstrate 3D imaging with localization precision of ~2.4 nm in the focal plane and ~1.9 nm along the optic axis. Localizing with a precision of <20 nm within ~100 µs, we establish this spatio-temporal resolution in single fluorophore tracking and apply it to the diffusion of single labeled lipids in lipid-bilayer model membranes.
- 5 March 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-12
Top Cited PapersOpen AccessMINFLUX nanometer-scale 3D imaging and microsecond-range tracking on a common fluorescence microscope
The recently introduced minimal photon fluxes (MINFLUX) concept pushed the resolution of fluorescence microscopy to molecular dimensions. Initial demonstrations relied on custom made, specialized microscopes, raising the question of the method’s general availability. Here, we show that MINFLUX implemented with a standard microscope stand can attain 1–3 nm resolution in three dimensions, rendering fluorescence microscopy with molecule-scale resolution widely applicable. Advances, such as synchronized electro-optical and galvanometric beam steering and a stabilization that locks the sample position to sub-nanometer precision with respect to the stand, ensure nanometer-precise and accurate real-time localization of individually activated fluorophores. In our MINFLUX imaging of cell- and neurobiological samples, ~800 detected photons suffice to attain a localization precision of 2.2 nm, whereas ~2500 photons yield precisions <1 nm (standard deviation). We further demonstrate 3D imaging with localization precision of ~2.4 nm in the focal plane and ~1.9 nm along the optic axis. Localizing with a precision of <20 nm within ~100 µs, we establish this spatio-temporal resolution in single fluorophore tracking and apply it to the diffusion of single labeled lipids in lipid-bilayer model membranes.
- Open Access
- 15 September 2011
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 44 (19) , 7508-7510
Flexible Microdomain Specific Staining of Block Copolymers for 3D Optical Nanoscopy
- 15 September 2011
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 44 (19) , 7508-7510
Open AccessFlexible Microdomain Specific Staining of Block Copolymers for 3D Optical Nanoscopy