CZChaonan Zhang

Chaonan Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chaonan Zhang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • sEMG-based recognition of wrist-hand movements using a composite transformer-LSTM model

    by Chaonan Zhang, Shuzhang Liang

    Surface electromyography (sEMG) signals are commonly utilized as a control source for upper-limb rehabilitation robots. Fast and high accuracy recognition of sEMG-based movements is crucial for the real-time control of robots. Here, we report a composite transformer-long short-term memory (LSTM) model for recognizing wrist-hand movements from sEMG signals. The sEMG data were collected to construct the training dataset. The consistent dataset was generated by a sliding window method to evaluate the model performance. We investigated the impact of window size and window increment on the sEMG-based recognition of wrist-hand movements. The results indicated that the recognition accuracy of the minimum window of 150 ms and the maximum window of 300 ms reached 94.68% and 99.35%, respectively. The recognition speeds were less than 0.3 ms. Finally, the trained transformer-LSTM model was combined with a majority voting strategy to determine the control outputs. The results confirm the model’s capability for real-time and high-accuracy control with minimal delay. This method holds substantial significance for rapid feedback control of rehabilitation robots.


  • Optoelectronic tweezers induced electroosmotic vortex for manipulating microparticles swarm

    by Chaonan Zhang, Shuzhang Liang, Lin Feng

    Microparticle swarms have wide applications, such as targeted delivery, biosensing, and micro-scale cleaning. Effective control of these swarms is, therefore, crucial. This study reports an approach for manipulating the microparticles swarm by utilizing optoelectronic tweezers induced dynamic electroosmotic vortex. Through combined numerical simulations and experimental investigations, we confirmed that patterned light virtual electrodes create electroosmotic vortex effect at illuminated edges, since the non-uniform electric field caused by the light pattern forms a strong tangential electric field component working on an electric double layer. Subsequently, microparticles were trapped by the vortex. The results indicated that microparticles self-assemble into chain-like structures in vortex, executing stable orbital motion controlled by light pattern geometry. The orbital range reached 279.2 μm. Finally, we demonstrated that, after captured by the light-induced electroosmotic vortex, microparticle swarms can be effectively transported across a microfluidic chip. The light pattern transporting speed can reach to 154.6 μm/s. Moreover, applying different light patterns can achieve different manipulating effects. This approach offers a versatile, non-contact method for potential applications in microparticle manipulation and microscale assembly.


  • Gradient light field for directional capturing and positioning microparticle in optoelectronic tweezers

    by Chaonan Zhang, Liping Pan, Shuzhang Liang, Lin Feng

    This study presents a gradient-light field in optoelectronic tweezers to achieve locating microparticles at a stable equilibrium position. By designing a light pattern with intensity gradients, a spatially varying dielectrophoretic force is generated, enabling microparticle manipulation. First, the electric field and force characters induced by gradient light are simulated. Subsequently, experimental results demonstrate that microparticles are moved along the direction of increasing light intensity and reach a stable position due to the change in force. Moreover, when an additional microparticle is introduced into the gradient light pattern, particle interactions lead to the other equilibrium state. The results verify that gradient light can be applied to directional positioning microparticles. The proposed method offers a label-free approach for studying bioparticles or cells with potential applications in positioning classification.


  • Open Access

    A radial micro-vibration system for reducing friction of passive interventional guidewire

    by Chaonan Zhang, Liping Pan, Xiajing Wang, Ru Guo, Yan Zhao, Shuzhang Liang

    Endovascular guidewire interventional surgery is an effective treatment for vascular diseases. However, due to factors, such as blood viscosity and complex vascular morphology, the guidewire is interfered by strong varying resistance when moving in the lesion’s vasculature. This greatly affects the efficiency and safety of the clinical operation. Here, we develop a novel system that applies ultrasonic micro-amplitude vibration to the conventional passive guidewire for studying a drag reduction effect under multiple factors. The system is mainly composed of a sandwich-type ultrasonic transducer and a step-type horn for concentrating the unidirectional energy for micro-vibration. Subsequently, comparative experiments are designed to verify the effectiveness of this system for drag reduction. Through the multifactorial interactions, we study the friction reduction law of the microvibration-assisted method on the guidewire and the optimal drag reduction parameter combinations. The results show that the drag reduction effect varies with the amplitude–frequency response curve. An ultrasound vibration amplitude and a simulated vessel bending angle were the most significant factors. Only vibration frequency and amplitude interacted with a simulated vessel shape. Finally, using the resonance frequency and the maximum vibration amplitude to drive the guidewire vibration, the maximum friction reduction rate can be obtained, up to 85.2%. This system is expected to have important applications in clinical vascular interventional procedures.


  • A ferrofluid microrobot for manipulation in multiple workspaces

    by Chaonan Zhang, Yan Zhao, Xiajing Wang, Shuzhang Liang

    Ferrofluid droplet has wide applications in bioanalysis manipulation. This study presents a ferrofluid microrobot for manipulation in different workspaces. Based on the deformation character of droplet, the ferrofluid microrobot has the capabilities of climbing the 3D (3-dimensional) surface, splitting in the channel, and transporting large particles. To manipulate in multiple workspaces with the capabilities, the size and magnetic force of ferrofluid are studied for suitable scenes. It shows that the diameter of 0.5 μl ferrofluid is around 980 μm. The manipulation force of different ferrofluid microrobots ranges from micronewton to millinewton. Subsequently, we have verified the manipulation of the ferrofluid microrobot on a 3D chip by permanent magnet. The ferrofluid microrobot can climb the stairs only when the height of the magnetic fluid is higher than twice the height of the stairs. Meanwhile, splitting of ferrofluid microrobot in the microfluidic chip has been successfully demonstrated. It indicates that the splitting influenced by the magnetic field and large magnetic force is easier to split the microrobot. Finally, the transportation of large polystyrene microparticles (150 μm) is confirmed by the ferrofluid microrobot. These capabilities show that the ferrofluid microrobot has the potential application advantage in biomedicine's micro-drug testing.


  • Reducing the Guidewire Friction for Endovascular Interventional Surgery by Radial Micro-Vibration

    by Chaonan Zhang, Shuzhang Liang, Yuqing Cao, Hongyan Sun, Lin Feng

    Guidewires for endovascular interventional surgery are inevitably affected by high frictional resistance because of direct contact with the vascular wall, which greatly reduces the operation efficiency and safety. This article presents a method of applying radial ultrasonic microvibration at the proximal end of a conventional passive guidewire to reduce the frictional resistance. The proposed method theoretically reduced the frictional resistance by reducing the friction coefficient, actual contact area, and the net friction time between the guidewire and vascular wall. The effectiveness of the proposed method was experimentally demonstrated in designed simulations of the blood vessel environment, where the influences of the vibration amplitude on the drag reduction effect were considered. The results indicated that vibrating the guidewire at the resonant frequency with the designed device clearly reduced the drag with a maximum frictional reduction rate of 85.19%. At the resonant frequency, the change in frictional resistance showed a linear negative correlation with the applied vibration amplitude. The proposed method offers a new approach to improving the efficiency and safety of vascular interventional surgery.


  • A Portable Remote Optoelectronic Tweezer System for Microobjects Manipulation

    by Yuqing Cao, Shuzhang Liang, Hanlong Chen, Chunyuan Gan, Li Song, Chaonan Zhang, Fumihito Arai, Lin Feng

    Non-contact manipulation technology has extensive application in the manipulation and fabrication of micro/nanomaterials. However, the manipulation devices are often precise and complex, operated only by professionals and subject to site constraints. We propose a simple optoelectronic tweezer platform, which can be controlled remotely and simply for the manipulation of microparticles at different scales, based on the novel manipulation technique called optically-induced dielectrophoresis. In this work, we design and set up the optoelectronic tweezer manipulation platform and develop the full-function human-computer interactive control interface and graphics rendering system to simplify the micro-operation process. Using Qt5.0 development environment, an experimental image processing system with multi-thread characteristics is developed, and the information interaction requirements needed in the experimental operation of optoelectronic tweezers are integrated into a control system to achieve unified information management and data analysis. Combined with cloud computing technology, the system realizes local/remote synchronous linkage operation, with cross-platform operation capability of various portable operating terminals like laptop and iPad.


  • Open Access

    A Versatile Optoelectronic Tweezer System for Micro-Objects Manipulation: Transportation, Patterning, Sorting, Rotating and Storage

    by Shuzhang Liang, Yuqing Cao, Yuguo Dai, Fenghui Wang, Xue Bai, Bin Song, Chaonan Zhang, Chunyuan Gan, Fumihito Arai, Lin Feng

    Non-contact manipulation technology has a wide range of applications in the manipulation and fabrication of micro/nanomaterials. However, the manipulation devices are often complex, operated only by professionals, and limited by a single manipulation function. Here, we propose a simple versatile optoelectronic tweezer (OET) system that can be easily controlled for manipulating microparticles with different sizes. In this work, we designed and established an optoelectronic tweezer manipulation system. The OET system could be used to manipulate particles with a wide range of sizes from 2 μm to 150 μm. The system could also manipulate micro-objects of different dimensions like 1D spherical polystyrene microspheres, 2D rod-shaped euglena gracilis, and 3D spiral microspirulina. Optical microscopic patterns for trapping, storing, parallel transporting, and patterning microparticles were designed for versatile manipulation. The sorting, rotation, and assembly of single particles in a given region were experimentally demonstrated. In addition, temperatures measured under different objective lenses indicate that the system does not generate excessive heat to damage bioparticles. The non-contact versatile manipulation reduces operating process and contamination. In future work, the simple optoelectronic tweezers system can be used to control non-contaminated cell interaction and micro-nano manipulation.