Sofia Schierbeck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sofia Schierbeck has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Jacob Hollenberg
Department of Clinical Science and Education, Södersjukhuset, Centre for Resuscitation Science, Karolinska Institutet, 17177 Stockholm, Sweden
3 shared publications Leif Svensson
3 shared publicationsMattias Ringh
3 shared publicationsPer Nordberg
3 shared publicationsAndreas Claesson
2 shared publications- Andreas Claesson
Centre for Resuscitation Science, Department of Clinical Science and Education, Södersjukhuset, Karolinska Institute, Stockholm, Sweden
2 shared publications
Latest Publications
- Open Access
- 17 November 2026
- Published by Elsevier in Resuscitation
Survival after out of hospital cardiac arrest in relation to AED usage in a multi response system including AED equipped drones
- 17 November 2026
- Published by Elsevier in Resuscitation
Open AccessSurvival after out of hospital cardiac arrest in relation to AED usage in a multi response system including AED equipped drones
- Open Access
- 17 February 2026
- Published by Elsevier in Resuscitation Plus
- Vol. 28
Dispatcher referral of bystanders to retrieve drone-delivered automated external defibrillators in cases of suspected out-of-hospital cardiac arrest
- 17 February 2026
- Published by Elsevier in Resuscitation Plus
- Vol. 28
Open AccessDispatcher referral of bystanders to retrieve drone-delivered automated external defibrillators in cases of suspected out-of-hospital cardiac arrest
- Top Cited PapersOpen Access
- 22 November 2023
- Published by Elsevier in The Lancet Digital Health
- Vol. 5 (12) , e862-e871
Drone delivery of automated external defibrillators compared with ambulance arrival in real-life suspected out-of-hospital cardiac arrests: a prospective observational study in Sweden
- 22 November 2023
- Published by Elsevier in The Lancet Digital Health
- Vol. 5 (12) , e862-e871
Top Cited PapersOpen AccessDrone delivery of automated external defibrillators compared with ambulance arrival in real-life suspected out-of-hospital cardiac arrests: a prospective observational study in Sweden
- Top Cited PapersOpen Access
- 26 August 2021
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 43 (15) , 1478-1487
Automated external defibrillators delivered by drones to patients with suspected out-of-hospital cardiac arrest
Early defibrillation is critical for the chance of survival in out-of-hospital cardiac arrest (OHCA). Drones, used to deliver automated external defibrillators (AEDs), may shorten time to defibrillation, but this has never been evaluated in real-life emergencies. The aim of this study was to investigate the feasibility of AED delivery by drones in real-life cases of OHCA. In this prospective clinical trial, three AED-equipped drones were placed within controlled airspace in Sweden, covering approximately 80 000 inhabitants (125 km2). Drones were integrated in the emergency medical services for automated deployment in beyond-visual-line-of-sight flights: (i) test flights from 1 June to 30 September 2020 and (ii) consecutive real-life suspected OHCAs. Primary outcome was the proportion of successful AED deliveries when drones were dispatched in cases of suspected OHCA. Among secondary outcomes was the proportion of cases where AED drones arrived prior to ambulance and time benefit vs. ambulance. Totally, 14 cases were eligible for dispatch during the study period in which AED drones took off in 12 alerts to suspected OHCA, with a median distance to location of 3.1 km [interquartile range (IQR) 2.8–3.4). AED delivery was feasible within 9 m (IQR 7.5–10.5) from the location and successful in 11 alerts (92%). AED drones arrived prior to ambulances in 64%, with a median time benefit of 01:52 min (IQR 01:35–04:54) when drone arrived first. In an additional 61 test flights, the AED delivery success rate was 90% (55/61). In this pilot study, we have shown that AEDs can be carried by drones to real-life cases of OHCA with a successful AED delivery rate of 92%. There was a time benefit as compared to emergency medical services in cases where the drone arrived first. However, further improvements are needed to increase dispatch rate and time benefits. ClinicalTrials.gov Identifier: NCT04415398. The dispatch centre alerts emergency medical services and a drone equipped with an automated external defibrillator for response to suspected out-of-hospital cardiac arrest. Data are presented with interquartile range for time benefit (min:s) and distance to the location (kilometres to the site and metres to the object when winching down the automated external defibrillator).
- 26 August 2021
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 43 (15) , 1478-1487
Top Cited PapersOpen AccessAutomated external defibrillators delivered by drones to patients with suspected out-of-hospital cardiac arrest
Early defibrillation is critical for the chance of survival in out-of-hospital cardiac arrest (OHCA). Drones, used to deliver automated external defibrillators (AEDs), may shorten time to defibrillation, but this has never been evaluated in real-life emergencies. The aim of this study was to investigate the feasibility of AED delivery by drones in real-life cases of OHCA. In this prospective clinical trial, three AED-equipped drones were placed within controlled airspace in Sweden, covering approximately 80 000 inhabitants (125 km2). Drones were integrated in the emergency medical services for automated deployment in beyond-visual-line-of-sight flights: (i) test flights from 1 June to 30 September 2020 and (ii) consecutive real-life suspected OHCAs. Primary outcome was the proportion of successful AED deliveries when drones were dispatched in cases of suspected OHCA. Among secondary outcomes was the proportion of cases where AED drones arrived prior to ambulance and time benefit vs. ambulance. Totally, 14 cases were eligible for dispatch during the study period in which AED drones took off in 12 alerts to suspected OHCA, with a median distance to location of 3.1 km [interquartile range (IQR) 2.8–3.4). AED delivery was feasible within 9 m (IQR 7.5–10.5) from the location and successful in 11 alerts (92%). AED drones arrived prior to ambulances in 64%, with a median time benefit of 01:52 min (IQR 01:35–04:54) when drone arrived first. In an additional 61 test flights, the AED delivery success rate was 90% (55/61). In this pilot study, we have shown that AEDs can be carried by drones to real-life cases of OHCA with a successful AED delivery rate of 92%. There was a time benefit as compared to emergency medical services in cases where the drone arrived first. However, further improvements are needed to increase dispatch rate and time benefits. ClinicalTrials.gov Identifier: NCT04415398. The dispatch centre alerts emergency medical services and a drone equipped with an automated external defibrillator for response to suspected out-of-hospital cardiac arrest. Data are presented with interquartile range for time benefit (min:s) and distance to the location (kilometres to the site and metres to the object when winching down the automated external defibrillator).
- Open Access
- 1 June 2021
- Published by Elsevier in Resuscitation
- Vol. 163, 136-145
National coverage of out-of-hospital cardiac arrests using automated external defibrillator-equipped drones — A geographical information system analysis
- 1 June 2021
- Published by Elsevier in Resuscitation
- Vol. 163, 136-145
Open AccessNational coverage of out-of-hospital cardiac arrests using automated external defibrillator-equipped drones — A geographical information system analysis