SSSamiul Based Shuvo

Samiul Based Shuvo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Samiul Based Shuvo has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Leakage-Safe Multimodal Deep Learning Framework for Multi-Target Binding Prediction in DNA-Encoded Chemical Libraries

    by Nufayer Jahan Reza, Mehnush Morshed, Samiul Based Shuvo, Jahid Ferdous

    Early stage drug discovery increasingly relies on computational models to identify molecules that bind therapeutic protein targets because large scale experimental screening is costly and time intensive. Although recent representation learning methods have improved molecular prediction, many studies still rely on a single chemical view or evaluate models under settings that may overestimate generalization. Motivated by this gap, this study proposes BELKA-BERT, a leakage-aware information fusion framework for multilabel binding prediction that integrates three complementary molecular representations: ChemBERTa-based SMILES embeddings, Morgan fingerprint descriptors, and learnable embeddings of three synthesis building blocks. The framework was developed on a curated subset of the Leash BELKA dataset for binding prediction against BRD4, HSA, and sEH. To support realistic evaluation, label combination stratification was combined with building block triplet grouping to prevent synthesis recipe overlap between training and test partitions. The learning pipeline further combines domain-adaptive masked language modelling, supervised multimodal fusion, class imbalance correction, promiscuity regularisation, temperature scaling, and target-specific threshold optimisation to improve ranking performance and decision reliability. On the leakage-aware working subset, the final fusion model achieved a micro average precision of 0.9722; Multi-seed evaluation on the class-realistic 3M-molecule BELKA working corpus, three-seed evaluation yielded micro-AP of 0.7917±0.0033, which is the more representative estimate of prospective screening performance. Controlled ablation experiments show that fingerprint removal causes the largest performance drop, confirming that explicit substructural information provides strong complementary value beyond transformer sequence embeddings. These results support BELKA-BERT as a robust, interpretable, and reproducible framework for trustworthy multi-target virtual screening.

  • Open Access

    Application of Wavelet Transformation and Artificial Intelligence Techniques in Healthcare: A Systemic Review

    by Samiul Based Shuvo, Syed Samiul Alam, Syeda Umme Ayman, Arbil Chakma, Massimo Salvi, Silvia Seoni, Prabal Datta Barua, Filippo Molinari, U. Rajendra Acharya

    The integration of wavelet transformation and artificial intelligence techniques has demonstrated significant potential in healthcare applications. Wavelet analysis enables multi‐scale signal decomposition and feature extraction that, when combined with machine and deep learning approaches, enhance the accuracy and efficiency of medical data analysis. This systematic review synthesizes 112 relevant studies from 2013 to 2023 exploring wavelet‐based artificial intelligence in healthcare. Our analysis reveals that the discrete wavelet transform dominates (43% of studies), primarily used for feature extraction from biosignals (82%) and medical images. Major applications include cardiac abnormality detection (29%), neurological disorder diagnosis (27%), and mental health assessment (16%), with classification accuracies frequently exceeding 95%. Key findings indicate a shift from traditional machine learning to deep learning approaches after 2020, with emerging trends in hybrid architectures. The review identifies critical challenges in computational efficiency, optimal wavelet selection, and clinical validation. Future developments should focus on real‐time processing optimization, interpretable deep learning models, multi‐modal data fusion, and validation on larger clinical datasets, advancing the translation of these systems into practical clinical tools.


  • Open Access

    Benchmarking Deep Learning Frameworks for Automated Diagnosis of Ocular Toxoplasmosis: A Comprehensive Approach to Classification and Segmentation

    by Syed Samiul Alam, Samiul Based Shuvo, Shams Nafisa Ali, Fardeen Ahmed, Arbil Chakma, Yeong Min Jang

    Diagnosis of Ocular toxoplasmosis (OT) usually involves clinical examination and imaging, which can be expensive and require specialized personnel. The use of artificial intelligence (AI) to analyze fundus images for diagnosing ocular diseases is gaining traction. Despite that, there has not been much work done focusing on the detection of OT. To address this issue, we conducted a benchmark study that evaluates the effectiveness of existing pre-trained networks using transfer learning techniques to detect and segment OT lesions from fundus images. The goal of this study is to provide insights for future researchers interested in harnessing deep learning (DL) techniques for automated, easy-to-use, and precise diagnostic approaches of OT using retinal fundus images. Along with that, we have performed an in-depth analysis of different feature extraction techniques to find the most optimal one for the classification and segmentation of lesions. For classification tasks, we have evaluated pre-trained models such as VGG16, MobileNetV2, InceptionV3, ResNet50, and DenseNet121 models. Among them, MobileNetV2 outperformed all other models in terms of Accuracy (Acc.), Recall, and F1-Score outperforming the second-best InceptionV3 by 0.7% higher Acc. However, DenseNet121 achieved the best result in terms of Precision, which was 0.1% higher than MobileNetV2. For the segmentation task, we replaced the encoder block of the U-Net with pre-trained MobileNetV2, InceptionV3, ResNet34, and VGG16 and trained with two different loss functions (Dice loss and Jaccard loss). The MobileNetV2/U-Net outperformed ResNet34 by 0.5% and 2.1% in terms of Acc. and Dice Score, respectively when the most optimum Jaccard loss function is employed during the training. The results mentioned in this study verify the effectiveness of the DL techniques in the diagnosis of OT.


  • Top Cited Papers
    Open Access

    An End-to-End Deep Learning Framework for Real-Time Denoising of Heart Sounds for Cardiac Disease Detection in Unseen Noise

    by Shams Nafisa Ali, Samiul Based Shuvo, Muhammad Ishtiaque Sayeed Al-Manzo, Anwarul Hasan, Taufiq Hasan

    Objective: The heart sound signals captured via a digital stethoscope are often distorted by environmental and physiological noise, altering their salient and critical properties. The problem is exacerbated in crowded low-resource hospital settings with high noise levels which degrades the diagnostic performance. In this study, we present a novel deep encoder-decoder-based denoising architecture (LU-Net) to suppress ambient and internal lung sound noises. Methods: Training is done using a large benchmark PCG dataset mixed with physiological noise, i.e., breathing sounds. Two different noisy datasets were prepared for experimental evaluation by mixing unseen lung sounds and hospital ambient noises with the clean heart sound recordings. We also used the inherently noisy portion of the PASCAL heart sound dataset for evaluation. Results: The proposed framework showed effective suppression of background noises in both unseen real-world data and synthetically generated noisy heart sound recordings, improving the signal-to-noise ratio (SNR) level by 5.575 dB on an average using only 1.32 M parameters. The proposed model outperforms the current state-of-the-art U-Net model with an average SNR improvement of 5.613 dB and 5.537 dB in the presence of lung sound and unseen hospital noise, respectively. LU-Net also outperformed the state-of-the-art Fully Convolutional Network (FCN) by 1.750 dB and 1.748 dB for lung sound and unseen hospital noise conditions, respectively. In addition, the proposed denoising method model improves classification accuracy by 38.93% in the noisy portion of the PASCAL heart sound dataset. Conclusion: The results presented in the paper indicate that our proposed architecture demonstrated a robust denoising performance on different datasets with diverse levels and characteristics of noise. Significance: The proposed deep learning-based PCG denoising approach is a pioneering study that can significantly improve the accuracy of computer-aided auscultation systems for detecting cardiac diseases in noisy, low-resource hospitals and underserved communities.


  • Open Access

    An End-to-end Deep Learning Framework for Real-Time Denoising of Heart Sounds for Cardiac Disease Detection in Unseen Noise

    by Shams Nafisa Ali, Samiul Based Shuvo, Taufiq Hasan, Muhammad Ishtiaque Sayeed Al-Manzo, Anwarul Hasan

    Objective: The heart sound signals captured via a digital stethoscope are often distorted by environmental and physiological noise, altering their salient and critical properties. The problem is exacerbated in crowded low-resource hospital settings with high noise levels which degrades the diagnostic performance. In this study, we present a novel deep encoder-decoder based denoising architecture (LU-Net) to suppress ambient and internal lung sound noises. Methods: Training is done using a large benchmark PCG dataset mixed with physiological noise, i.e., breathing sounds. Two different noisy datasets were prepared for experimental evaluation by mixing unseen lung sounds and hospital ambient noises with the clean heart sound recordings. We also use the inherently noisy portion of the PASCAL heart sound dataset for evaluation. Results: The proposed framework showed effective suppression of background noises in both un?seen real-world data and synthetically generated noisy heart sound recordings, improving the signal-to-noise ratio (SNR) level by 5.575 dB on an average using only 1.32 M parameters. The proposed model outperforms the current state-of-the-art U-Net model with an average SNR improvement of 5.613 dB and 5.537 dB in the presence of lung sound and unseen hospital noise, respectively. LU-Net also outperformed the state-of-the-art Fully Convolutional Network (FCN) by 1.750 dB and 1.748 dB for lung sound and unseen hospital noise conditions, respectively. In addition, the proposed denoising method model improves classification accuracy by 38.93% in the noisy portion of the PASCAL heart sound dataset. Conclusion: The results presented in the paper indicate that our proposed architecture demonstrated a robust denoising performance on different datasets with diverse levels and characteristics of noise. Significance: The proposed deep learning-based PCG denoising approach is a pioneering study that can significantly improve the accuracy of computer-aided auscultation systems for detecting cardiac diseases in noisy, low-resource hospitals and underserved communities.


  • Top Cited Papers

    A Lightweight CNN Model for Detecting Respiratory Diseases From Lung Auscultation Sounds Using EMD-CWT-Based Hybrid Scalogram

    by Samiul Based Shuvo, Shams Nafisa Ali, Soham Irtiza Swapnil, Taufiq Hasan, Mohammed Imamul Hassan Bhuiyan

    Listening to lung sounds through auscultation is vital in examining the respiratory system for abnormalities. Automated analysis of lung auscultation sounds can be beneficial to the health systems in low-resource settings where there is a lack of skilled physicians. In this work, we propose a lightweight convolutional neural network (CNN) architecture to classify respiratory diseases from individual breath cycles using hybrid scalogram-based features of lung sounds. The proposed feature-set utilizes the empirical mode decomposition (EMD) and the continuous wavelet transform (CWT). The performance of the proposed scheme is studied using a patient independent train-validation-test set from the publicly available ICBHI 2017 lung sound dataset. Employing the proposed framework, weighted accuracy scores of 98.92% for three-class chronic classification and 98.70% for six-class pathological classification are achieved, which outperform well-known and much larger VGG16 in terms of accuracy by absolute margins of 1.10% and 1.11%, respectively. The proposed CNN model also outperforms other contemporary lightweight models while being computationally comparable.