Krisdiyanto Acknowledgment
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Krisdiyanto Acknowledgment has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Azuddin Bin Mamat
CPDM, Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
1 shared publication Eki Meng Afifuddin
Mechanical and Industrial Engineering Department, Faculty of Engineering, Universitas Gadjah Mada, Yogyakarta, Indonesia
1 shared publicationM. Azuddin
CPDM, Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
1 shared publicationMuhammad Akhsin Muflikhun
Mechanical and Industrial Engineering Department, Faculty of Engineering, Universitas Gadjah Mada, Yogyakarta, Indonesia
1 shared publication- Muhammad Khairi Faiz
Department of Mechanical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia
1 shared publication Muhammad Khairi Faiz Bin Ahmad Hairuddin
CPDM, Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
1 shared publication
Latest Publications
- Open Access
- 15 January 2025
- Published by Universidad Mayor de San Simon in Gaceta Médica Boliviana
- Vol. 48 (1) , 71-82
Analysis of The Effect of Syringe Barrel Volume on Mechanical Failure During Injection
Background: Syringes are critical medical devices whose mechanical integrity is essential to ensure safety during injections. The cylinder volume can influence their mechanical performance. Objective: This study investigates how cylinder volume affects the mechanical integrity of syringes by analyzing von Mises stress, buckling risk, and overall safety during injection. Materials and Methods: Autodesk Inventor 2021 and Ansys 2019 R2 were used to analyze syringes with volumes of 1 ml, 3 ml, 5 ml, and 10 ml. Von Mises stress and buckling susceptibility were evaluated during simulated injections. Results: Smaller syringes showed higher stress levels: 14.030 MPa for the 1 ml syringe, 10.532 MPa for the 3 ml, and 7.0150 MPa for the 5 ml and 10 ml. The 5 ml syringe was the most susceptible to buckling, with a critical pressure of -0.1757 MPa. Despite this, all designs are safe under normal operating conditions. Conclusions: Cylinder volume affects mechanical performance, but with proper design, even smaller syringes can remain safe, enhancing the reliability of medical treatments.
- 15 January 2025
- Published by Universidad Mayor de San Simon in Gaceta Médica Boliviana
- Vol. 48 (1) , 71-82
Open AccessAnalysis of The Effect of Syringe Barrel Volume on Mechanical Failure During Injection
Background: Syringes are critical medical devices whose mechanical integrity is essential to ensure safety during injections. The cylinder volume can influence their mechanical performance. Objective: This study investigates how cylinder volume affects the mechanical integrity of syringes by analyzing von Mises stress, buckling risk, and overall safety during injection. Materials and Methods: Autodesk Inventor 2021 and Ansys 2019 R2 were used to analyze syringes with volumes of 1 ml, 3 ml, 5 ml, and 10 ml. Von Mises stress and buckling susceptibility were evaluated during simulated injections. Results: Smaller syringes showed higher stress levels: 14.030 MPa for the 1 ml syringe, 10.532 MPa for the 3 ml, and 7.0150 MPa for the 5 ml and 10 ml. The 5 ml syringe was the most susceptible to buckling, with a critical pressure of -0.1757 MPa. Despite this, all designs are safe under normal operating conditions. Conclusions: Cylinder volume affects mechanical performance, but with proper design, even smaller syringes can remain safe, enhancing the reliability of medical treatments.
- Open Access
- 9 June 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (23) , e33983
An analysis of the effect of syringe barrel volume on performance and user perception
In the market, there are many types and shapes of syringes. One of the groupings of syringe types is based on barrel volume. The shape of the product design affects performance and user perception. The aim of this study is to investigate the effect of barrel volume on its performance and user perception. We performed analysis following international organization for standardization 7886 procedures on syringe with 1 mL, 3 mL, 5 mL, and 10 mL volume. In addition, a user perception test was conducted on 29 respondents using a questionnaire with the Likert chart method. This study indicates that the bigger the syringe volume, the larger the dead space and the force to operate the piston are. A larger syringe volume also raises the volume that changes due to the plunger position increase. Meanwhile, the barrel volume does not affect water and water leakage, as we did not observe any leak during the syringe tests in our experiment. In addition, the user perception test shows that the barrel’s length influences the ease of device control during the injection. The volume of the barrel negatively correlated with its effect to the environment. The safety features of all syringes are similar except for the 3 mL syringe, which has a value of 0.1 points difference to other syringes.
- 9 June 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (23) , e33983
Open AccessAn analysis of the effect of syringe barrel volume on performance and user perception
In the market, there are many types and shapes of syringes. One of the groupings of syringe types is based on barrel volume. The shape of the product design affects performance and user perception. The aim of this study is to investigate the effect of barrel volume on its performance and user perception. We performed analysis following international organization for standardization 7886 procedures on syringe with 1 mL, 3 mL, 5 mL, and 10 mL volume. In addition, a user perception test was conducted on 29 respondents using a questionnaire with the Likert chart method. This study indicates that the bigger the syringe volume, the larger the dead space and the force to operate the piston are. A larger syringe volume also raises the volume that changes due to the plunger position increase. Meanwhile, the barrel volume does not affect water and water leakage, as we did not observe any leak during the syringe tests in our experiment. In addition, the user perception test shows that the barrel’s length influences the ease of device control during the injection. The volume of the barrel negatively correlated with its effect to the environment. The safety features of all syringes are similar except for the 3 mL syringe, which has a value of 0.1 points difference to other syringes.
- Open Access
- 9 December 2022
- Published by Wolters Kluwer Health in Medicine
- Vol. 101 (49) , e31812
The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review
A syringe is used to inject fluid or medicine into the patient’s soft tissue. The main components of the syringe were the needle, barrel, and plunger. The use of syringes in the medical world is relatively high, and especially since the COVID-19 pandemic, the use of hypodermic syringes increased sharply due to vaccination. The syringe used must be effective and of good quality, so the International Organization for Standardization (ISO) has published test procedures and minimum specifications for hypodermic syringes. The performance of the syringe can be observed from the dead space, force piston operation, water and air leakage, and fitting position of the plunger in the barrel. This review shows that most researchers use the weighing method to measure the dead space, although some use other methods. The researchers found that most of the products met the minimum specifications of the ISO, and that the dimensions and shape of the syringe affected the dead space. Researchers have not examined other performance measures recommended by the ISO. Researchers have focused more on force injection than force piston operation, leakage after injection or back spray than air and water leakage, and reduction the friction of the plunger without considering the fitting position of the plunger in the barrel.
- 9 December 2022
- Published by Wolters Kluwer Health in Medicine
- Vol. 101 (49) , e31812
Open AccessThe hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review
A syringe is used to inject fluid or medicine into the patient’s soft tissue. The main components of the syringe were the needle, barrel, and plunger. The use of syringes in the medical world is relatively high, and especially since the COVID-19 pandemic, the use of hypodermic syringes increased sharply due to vaccination. The syringe used must be effective and of good quality, so the International Organization for Standardization (ISO) has published test procedures and minimum specifications for hypodermic syringes. The performance of the syringe can be observed from the dead space, force piston operation, water and air leakage, and fitting position of the plunger in the barrel. This review shows that most researchers use the weighing method to measure the dead space, although some use other methods. The researchers found that most of the products met the minimum specifications of the ISO, and that the dimensions and shape of the syringe affected the dead space. Researchers have not examined other performance measures recommended by the ISO. Researchers have focused more on force injection than force piston operation, leakage after injection or back spray than air and water leakage, and reduction the friction of the plunger without considering the fitting position of the plunger in the barrel.
- Open Access
- 26 February 2021
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 1 (8 (109)) , 25-35
An analysis of tube thickness effect on shell and tube heat exchanger
Heat exchangers are important equipment for the process of placing heat. The most widely used type of heat exchanger is shell and tube. This type is widely used because of its simple and easy design. Design of shell and tube heat exchangers is done by the side or shell variations to get the desired performance. Therefore, research is conducted to study the effect of tube thickness on heat transfer, pressure drop, and stress that occurs in the shell and tube heat exchanger so that the optimal tube thickness is obtained. In this research, the activities carried out are the design of heat exchangers for the production of oxygen with a capacity of 30 tons/day. The standard used in this study is the 9th edition heat exchanger design guidance document compiled by the Tubular Exchanger Manufacturer Association (TEMA). Analysis of the tube thickness effect on heat transfer, pressure drop, and stress was carried out using the SimScale platform. The effect of variations in tube thickness on heat transfer is that the thicker the tube, the lower the heat transfer effectiveness. The highest value of the heat exchanger effectiveness is 0.969 at the tube thickness variation of 0.5 mm. The lowest value of the heat exchanger effectiveness is 0.931 at the tube thickness variation of 1.5 mm. The effect of variations in tube thickness on pressure drop is that the thicker the tube, the higher the pressure drop. The highest value of pressure drop is in the variation in tube thickness of 1.5 mm, 321 Pa. The lowest value of drop pressure is in the variation of 0.5 mm tube thickness, which is 203 Pa. The thickness of the tube also increases the maximum stress on the components of the shell, head, tubesheet, baffle, and saddle, but the value is fluctuating
- 26 February 2021
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 1 (8 (109)) , 25-35
Open AccessAn analysis of tube thickness effect on shell and tube heat exchanger
Heat exchangers are important equipment for the process of placing heat. The most widely used type of heat exchanger is shell and tube. This type is widely used because of its simple and easy design. Design of shell and tube heat exchangers is done by the side or shell variations to get the desired performance. Therefore, research is conducted to study the effect of tube thickness on heat transfer, pressure drop, and stress that occurs in the shell and tube heat exchanger so that the optimal tube thickness is obtained. In this research, the activities carried out are the design of heat exchangers for the production of oxygen with a capacity of 30 tons/day. The standard used in this study is the 9th edition heat exchanger design guidance document compiled by the Tubular Exchanger Manufacturer Association (TEMA). Analysis of the tube thickness effect on heat transfer, pressure drop, and stress was carried out using the SimScale platform. The effect of variations in tube thickness on heat transfer is that the thicker the tube, the lower the heat transfer effectiveness. The highest value of the heat exchanger effectiveness is 0.969 at the tube thickness variation of 0.5 mm. The lowest value of the heat exchanger effectiveness is 0.931 at the tube thickness variation of 1.5 mm. The effect of variations in tube thickness on pressure drop is that the thicker the tube, the higher the pressure drop. The highest value of pressure drop is in the variation in tube thickness of 1.5 mm, 321 Pa. The lowest value of drop pressure is in the variation of 0.5 mm tube thickness, which is 203 Pa. The thickness of the tube also increases the maximum stress on the components of the shell, head, tubesheet, baffle, and saddle, but the value is fluctuating