TTTian Tan

Tian Tan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tian Tan has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Deep learning models detect neuromuscular disease and quantify functional impairment from video-derived biomechanics data

    by Sydney C. Covitz, Parker S. Ruth, Shelby Vogt-Domke, Carmichael Ong, Tian Tan, Audrey Chun, Sarah Ismail, Lin Karman, Julie Muccini, Shannon Li, et al.

    Measurements of human movement are critical for evaluating patients with neuromuscular diseases. However, current clinical tools are limited in sensitivity and can fail to detect the full spectrum of movement changes patients may exhibit. These limitations can obscure early signs of decline, delaying interventions that could preserve function and independence. OpenCap––a smartphone application that performs video-based markerless motion capture––can help address this gap by enabling scalable, out-of-lab measurements of human movement. Here, we present a method for both detecting disease and quantifying the severity of impaired movement from smartphone videos of a patient’s motion. We used OpenCap to measure kinematics from 337 individuals with diagnoses spanning 12 rare, genetically-defined neuromuscular diseases and 78 age-matched healthy controls. Our dataset is the largest existing publicly available resource of body segment kinematics for this class of diseases. These data were collected in neuromuscular clinics during regular clinic visits as well as at conferences and community events across the United States. We trained deep learning models on these kinematic time series to differentiate between participants with neuromuscular disease and controls (AUROC = 0.97 [0.93-1.00]). We also developed a movement impairment severity score that correlates with both participants’ ratings of their own functional abilities (ρ= -0.81, p<0.001) and existing clinical tests of movement capabilities such as run speed (ρ= -0.83, p<0.001). Our methods for detecting disease and deriving quantitative biomarkers of movement impairment from smartphone videos have the potential to complement clinical assessments, inform screening protocols, and improve clinical trial endpoints.

  • Toward measurement of muscle forces during movement

    by Tian Tan, McKenzie S. White, Scott L. Delp

    Ultra-wideband radar identifies components of a muscle’s contractile state to estimate muscle force.

  • Top Cited Papers

    GaitDynamics: a generative foundation model for analyzing human walking and running

    by Tian Tan, Tom Van Wouwe, Keenon F. Werling, C. Karen Liu, Scott L. Delp, Jennifer L. Hicks, Akshay S. Chaudhari

    Understanding the dynamics of human gait, including both motions and forces, is vital to promote human mobility. While deep learning models may have advantages over costly laboratory-based experiments and physics-based simulations, existing models have been trained on small datasets with homogeneous demographics and focus on predicting a single output. We developed GaitDynamics, a generative foundation model trained on a large dataset of diverse gait patterns, which allows for flexible inputs, outputs and clinical applications. We illustrate the use of GaitDyanmics for: (1) estimating ground reaction forces from kinematics with high accuracy even with missing kinematic data, (2) predicting the effects of gait modifications on knee loading without resource-intensive experiments and (3) predicting kinematic and force changes that occur with increasing running speeds. Our results demonstrate the accuracy and efficiency of GaitDynamics, showing its potential to assess and optimize gait for injury prevention, disease treatment and performance coaching. All data, code and trained models are publicly shared.


  • Open Access

    Integrating Machine Learning with Musculoskeletal Simulation Improves OpenCap Video-Based Dynamics Estimation

    by Emily Y. Miller, Tian Tan, Antoine Falisse, Scott D. Uhlrich

    Objective: Musculoskeletal dynamics influence the progression and rehabilitation of many movement-related conditions. However, accurately estimating whole-body dynamics using accessible tools, like smartphone video, remains challenging. Physics-based and machine learning (ML)–based dynamic predictions each offer advantages, but both approaches struggle to achieve both high accuracy and physical realism. Here, we created a hybrid ML–simulation framework to improve estimates of ground reaction forces, joint moments, and joint contact forces from smartphone video kinematics. Methods: We used machine learning models to predict ground reaction forces and centers of pressure from video-based kinematics. The hybrid framework generates a dynamic simulation that tracks predicted forces and kinematics while enforcing dynamic consistency. We compared the hybrid model’s performance with a simulation-only approach and with ML forces applied through inverse dynamics. We evaluated mean absolute error from lab-based reference data (inverse dynamics from marker and force plate data) from 10 individuals walking. Results: The hybrid model had 29% lower joint moment errors compared to simulations (p<0.001) and 45% lower errors compared to the ML-only approach (p<0.001). It also reduced vertical ground force error by 40% compared to simulations. The hybrid approach improved key metrics of joint loading related to knee osteoarthritis progression by 13–30% compared to simulations. Conclusion: Our hybrid model outperforms purely physics-based and ML approaches for estimating dynamics from smartphone video during walking. Significance: These methods move us closer to fast, accurate, and scalable assessments of whole-body musculoskeletal dynamics, which will enable large out-of-lab biomechanics studies and precision treatment of gait-related conditions.

  • Novel Deep Learning Model to Estimate Knee Flexion and Adduction Moments With Wearable IMUs During Treadmill and Overground Walking

    by Alon Sabaty, Adi Fishman, Shani Batcir, Tian Tan, Peter B. Shull, Kfir Levy, Arielle G. Fischer

    A major issue after total knee replacement (TKR) surgery is asymmetric gait kinetics, which increases knee loads on the non-operated knee. This imbalance accelerates osteoarthritis (OA) progression, often leading to a second contralateral TKR. There is a clear need for an advanced wearable system with multiple sensors to accurately estimate gait kinetics in natural environments. This study aims to develop a machine learning framework that exclusively uses wearable inertial measurement units (IMUs) during overground and treadmill walking to estimate knee flexion moment (KFM) and knee adduction moment (KAM), significant biomechanical factors linked to OA. We introduce a novel deep learning model that combines a Long Short-Term Memory (LSTM)-based Autoencoder and Variational Gaussian Process (VGP) to estimate the mean and uncertainty region of the KAM and KFM. Seventeen healthy participants performed treadmill walking trials, while a separate group of seventeen healthy participants performed overground walking trials for model training and validation. Results demonstrated Root Mean Square Errors (RMSE) of 0.49%BW·BH (body weight × body height) and 0.73%BW·BH for KAM and KFM, respectively, during treadmill walking and 0.74%BW·BH and 0.49%BW·BH for KAM and KFM respectively during overground walking, which is more accurate than existing approaches. The proposed model with wearable IMUs could enable knee health monitoring and rehabilitation for these key biomechanical factors linked to the progression of knee joint pathologies outside of traditional biomechanical laboratories with large, tethered equipment and into clinics, hospitals, and the community.


  • Open Access

    GaitDynamics: A Generative Foundation Model for Analyzing Human Walking and Running

    by Tian Tan, Tom Van Wouwe, Keenon Werling, C. Karen Liu, Scott Delp, Jennifer Hicks, Akshay Chaudhari

    Understanding the dynamics of human gait, including both motions and forces, is vital to promote human health and performance. Conventional gait analysis requires laboratory-based experiments and physics-based simulations to quantify gait dynamics and analyze how dynamics change with treatment, training, injury, and disease. However, the high costs associated with experiments and simulations has confined the use of gait dynamics to small-scale research studies. While deep learning models offer low-cost prediction, and can be highly expressive in fitting large-scale data, existing models have primarily been trained on small datasets with homogenous demographics and focused on predicting a single output. To overcome these limitations, we developed GaitDynamics, a generative foundation model for human gait that is trained on a large dataset with diverse participant demographics and gait patterns. GaitDynamics can be used for diverse tasks with different inputs, outputs, and clinical applications, which we illustrate in three examples: i) estimating ground reaction forces from kinematics with high accuracy and robustness even with missing kinematic data and for populations not included in the training dataset, ii) predicting the influence of gait modifications on knee loading without the need for resource-intensive experiments, and iii) predicting kinematic and force changes that occur with increasing running speeds. These representative tasks demonstrate that GaitDynamics makes accurate and rapid predictions in seconds based on flexible inputs, showing its potential to assess and optimize gait for injury prevention, disease treatment, and performance coaching. All data, code, and trained models are publicly shared.


  • Influence of Number of Subjects and Number of Trials on Biomechanical Variable Estimation via Deep-Learning Models and Wearable IMUs During Drop Landings

    by Tao Sun, Tian Tan, Dongxuan Li, Bernd Markert, Peter B. Shull, Franz Bamer

    Data diversity and quantity are crucial for training deep learning models. However, the impact of dataset diversity and size on biomechanical variable estimation models has not been explicitly investigated during drop landings. This work investigates the impact of the number of subjects and the number of trials per subject on the performance of wearable IMU-driven deep-learning models for knee moment and ground reaction force estimation during drop landing tasks. An investigation dataset with 16 subjects and 25 trials per subject was collected in a biomechanical laboratory. The impact of subject and trial quantification was explored under different model complexity and types, as well as data augmentation methods using the investigation dataset. The deeplearning models were implemented by a feature extractor and an estimator realized by several fully connected layers. The feature extractor was independently evaluated with fully-connected neural networks, convolutional neural network (CNN), long short-term memory (LSTM) model, and transformer model. Three transformation-based data augmentation methods were proposed and compared with the measured dataset. The results showed that the minimum required number of subjects and trials for the models to achieve an estimation performance of 0:85 of R-squared, 0:4 body weight × body height of RMSE, and 0:1 of rRMSE is five subjects and five trials. Intriguingly, adding more subjects to the dataset improved the estimation performance while adding more trials did not. Additionally, the proposed data augmentation can alleviate the data scarcity issue when the number of trials is small.


  • Step Width Estimation in Individuals With and Without Neurodegenerative Disease via a Novel Data-Augmentation Deep Learning Model and Minimal Wearable Inertial Sensors

    by Hong Wang, Zakir Ullah, Eran Gazit, Marina Brozgol, Tian Tan, Jeffrey M. Hausdorff, Peter B. Shull, Penina Ponger

    Step width is vital for gait stability, postural balance control, and fall risk reduction. However, estimating step width typically requires either fixed cameras or a full kinematic body suit of wearable inertial measurement units (IMUs), both of which are often too expensive and time-consuming for clinical application. We thus propose a novel data-augmented deep learning model for estimating step width in individuals with and without neurodegenerative disease using a minimal set of wearable IMUs. Twelve patients with neurodegenerative, clinically diagnosed Spinocerebellar ataxia type 3 (SCA3) performed over ground walking trials, and seventeen healthy individuals performed treadmill walking trials at various speeds and gait modifications while wearing IMUs on each shank and the pelvis. Results demonstrated step width mean absolute errors of 3.3 $\pm$ 0.7cm and 2.9 $\pm$ 0.5cm for the neurodegenerative and healthy groups, respectively, which were below the minimal clinically important difference of 6.0cm. Step width variability mean absolute errors were 1.5cm and 0.8cm for neurodegenerative and healthy groups, respectively. Data augmentation significantly improved accuracy performance in the neurodegenerative group, likely because they exhibited larger variations in walking kinematics as compared with healthy subjects. These results could enable clinically meaningful and accurate portable step width monitoring for individuals with and without neurodegenerative disease, potentially enhancing rehabilitative training, assessment, and dynamic balance control in clinical and real-life settings.


  • Open Access

    Synthetic IMU Datasets and Protocols Can Simplify Fall Detection Experiments and Optimize Sensor Configuration

    by Jie Tang, Bin He, Junkai Xu, Tian Tan, Zhipeng Wang, Yanmin Zhou, Shuo Jiang

    Falls represent a significant cause of injury among the elderly population. Extensive research has been devoted to the utilization of wearable IMU sensors in conjunction with machine learning techniques for fall detection. To address the challenge of acquiring costly training data, this paper presents a novel method that generates a substantial volume of synthetic IMU data with minimal actual fall experiments. First, unmarked 3D motion capture technology is employed to reconstruct human movements. Subsequently, utilizing the biomechanical simulation platform Opensim and forward kinematic methods, an ample amount of training data from various body segments can be custom generated. Synthetic IMU data was then used to train a machine learning model, achieving testing accuracies of 91.99% and 86.62% on two distinct datasets of actual fall-related IMU data. Building upon the simulation framework, this paper further optimized the single IMU attachment position and multiple IMU combinations on fall detection. The proposed method simplifies fall detection data acquisition experiments, provides novel venue for generating low cost synthetic data in scenario where acquiring data for machine learning is challenging and paves the way for customizing machine learning configurations.


  • Self-Supervised Learning Improves Accuracy and Data Efficiency for IMU-Based Ground Reaction Force Estimation

    by Tian Tan, Peter B. Shull, Jenifer L. Hicks, Scott D. Uhlrich, Akshay S. Chaudhari

    Objective: Recent deep learning techniques hold promise to enable IMU-driven kinetic assessment; however, they require large extents of ground reaction force (GRF) data to serve as labels for supervised model training. We thus propose using existing self-supervised learning (SSL) techniques to leverage large IMU datasets to pre-train deep learning models, which can improve the accuracy and data efficiency of IMU-based GRF estimation. Methods: We performed SSL by masking a random portion of the input IMU data and training a transformer model to reconstruct the masked portion. We systematically compared a series of masking ratios across three pre-training datasets that included real IMU data, synthetic IMU data, or a combination of the two. Finally, we built models that used pre-training and labeled data to estimate GRF during three prediction tasks: overground walking, treadmill walking, and drop landing. Results: When using the same amount of labeled data, SSL pre-training significantly improved the accuracy of 3-axis GRF estimation during walking compared to baseline models trained by conventional supervised learning. Fine-tuning SSL model with 1–10% of walking data yielded comparable accuracy to training baseline model with 100% of walking data. The optimal masking ratio for SSL is 6.25–12.5%. Conclusion: SSL leveraged large real and synthetic IMU datasets to increase the accuracy and data efficiency of deep-learning-based GRF estimation, reducing the need for labeled data. Significance: This work, with its open-source code and models, may unlock broader use cases of IMU-driven kinetic assessment by mitigating the scarcity of GRF measurements in practical applications.