Yanhua Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanhua Zhang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Wuliji Hasi
National Key Laboratory of Laser Spatial Information Harbin Institute of Technology Harbin P.R. China
3 shared publications - Siqingaowa Han
Affiliated Hospital of Inner Mongolia Minzu University, Tongliao, 028043, China
2 shared publications Xia Han
The Second Affiliated Hospital of Harbin Medical University, Harbin, 150086, China
2 shared publicationsYu Gao
Zhengzhou Research Institute, Harbin Institute of Technology, Zhengzhou, 450000, China; National Key Laboratory of Laser Spatial Information, Harbin Institute of Technology, Harbin, 150080, China
2 shared publicationsChen Zhang
National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology, Harbin, P. R. China
1 shared publicationGuoqiang Fang
National Key Laboratory of Laser Spatial Information, Harbin Institute of Technology, Harbin 150080, China; Zhengzhou Research Institute, Harbin Institute of Technology, Zhengzhou 450000, China
1 shared publication
Latest Publications
- 26 May 2025
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 342, 126482
Diagnosis of uterine diseases by label-free serum SERS fingerprints with machine learning
- 26 May 2025
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 342, 126482
Diagnosis of uterine diseases by label-free serum SERS fingerprints with machine learning
- 6 March 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (12) , 1662-1669
Effective SERS method for identification of dexmedetomidine hydrochloride in biological samples
In recent years, the abuse of dexmedetomidine hydrochloride (DH) in various criminal cases has increased demand for the rapid and effective supervision and determination of DH. In this paper, based on the SERS method, DH in aqueous solution, urine and serum was effectively and sensitively detected. On the basis of density functional theory (DFT), the Raman peaks of DH were identified by systematic calculation. The SERS performance for the measurement of DH was compared between Ag colloid and paper-based substrate. It was found that Ag colloid together with KI as an aggregator was equipped with better SERS behavior and could thus be applied in the analysis of DH in biological samples. Furthermore, with simple pre-treatment, DH in urine and serum were successfully determined with detection limits down to 10 μg mL−1 and 12 μg mL−1, respectively. The linear relationships between the characteristic peak intensity and the concentration of DH in urine and serum were established and the recovery rates were calculated with low relative standard deviation (RSD). This fast, accurate and non-destructive SERS method lays a reliable foundation for rapid on-site detection of DH.
- 6 March 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (12) , 1662-1669
Effective SERS method for identification of dexmedetomidine hydrochloride in biological samples
In recent years, the abuse of dexmedetomidine hydrochloride (DH) in various criminal cases has increased demand for the rapid and effective supervision and determination of DH. In this paper, based on the SERS method, DH in aqueous solution, urine and serum was effectively and sensitively detected. On the basis of density functional theory (DFT), the Raman peaks of DH were identified by systematic calculation. The SERS performance for the measurement of DH was compared between Ag colloid and paper-based substrate. It was found that Ag colloid together with KI as an aggregator was equipped with better SERS behavior and could thus be applied in the analysis of DH in biological samples. Furthermore, with simple pre-treatment, DH in urine and serum were successfully determined with detection limits down to 10 μg mL−1 and 12 μg mL−1, respectively. The linear relationships between the characteristic peak intensity and the concentration of DH in urine and serum were established and the recovery rates were calculated with low relative standard deviation (RSD). This fast, accurate and non-destructive SERS method lays a reliable foundation for rapid on-site detection of DH.