Irene Rubia-Rodríguez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Irene Rubia-Rodríguez has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Ortega
IMDEA Nanoscience, Faraday 9, 28049 Madrid, Spain
4 shared publications - Alessandro Arduino
Istituto Nazionale di Ricerca Metrologica (INRiM) Torino Italy
2 shared publications - Daniel Jaque
Nanomaterials for Bioimaging Group (nanoBIG) Departamento de Física de Materiales Facultad de Ciencias Universidad Autónoma de Madrid Madrid Spain
2 shared publications - Erving Ximendes
Nanomaterials for Bioimaging Group (NanoBIG), Departamento de Física de Materiales, Facultad de Ciencias, Universidad Autónoma de Madrid, Madrid, Spain
2 shared publications - Luca Zilberti
Istituto Nazionale di Ricerca Metrologica (INRiM) Torino Italy
2 shared publications - Mario Chiampi
Istituto Nazionale di Ricerca Metrologica (INRiM) Torino Italy
2 shared publications
Latest Publications
- Open Access
- 14 September 2022
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 39 (1) , 1222-1232
Heating of metallic biliary stents during magnetic hyperthermia of patients with pancreatic ductal adenocarcinoma: an in silico study
To investigate the eddy current heating that occurs in metallic biliary stents during magnetic hyperthermia treatments and to assess whether these implants should continue to be an exclusion criter...
- 14 September 2022
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 39 (1) , 1222-1232
Open AccessHeating of metallic biliary stents during magnetic hyperthermia of patients with pancreatic ductal adenocarcinoma: an in silico study
To investigate the eddy current heating that occurs in metallic biliary stents during magnetic hyperthermia treatments and to assess whether these implants should continue to be an exclusion criter...
- Open Access
- 3 March 2021
- Published by Wiley in Advanced Science
- Vol. 8 (9) , 2003838
Reaching Deeper: Absolute In Vivo Thermal Reading of Liver by Combining Superbright Ag2S Nanothermometers and In Silico Simulations
Luminescent nano‐thermometry is a fast‐developing technique with great potential for in vivo sensing, diagnosis, and therapy. Unfortunately, it presents serious limitations. The luminescence generated by nanothermometers, from which thermal readout is obtained, is strongly distorted by the attenuation induced by tissues. Such distortions lead to low signal levels and entangle absolute and reliable thermal monitoring of internal organs. Overcoming both limitations requires the use of high‐brightness luminescent nanothermometers and adopting more complex approaches for temperature estimation. In this work, it is demonstrated how superbright Ag2S nanothermometers can provide in vivo, reliable, and absolute thermal reading of the liver during laser‐induced hyperthermia. For that, a new procedure is designed in which thermal readout is obtained from the combination of in vivo transient thermometry measurements and in silico simulations. The synergy between in vivo and in silico measurements has made it possible to assess relevant numbers such as the efficiency of hyperthermia processes, the total heat energy deposited in the liver, and the relative contribution of Ag2S nanoparticles to liver heating. This work provides a new way for absolute thermal sensing of internal organs with potential application not only to hyperthermia processes but also to advanced diagnosis and therapy.
- 3 March 2021
- Published by Wiley in Advanced Science
- Vol. 8 (9) , 2003838
Open AccessReaching Deeper: Absolute In Vivo Thermal Reading of Liver by Combining Superbright Ag2S Nanothermometers and In Silico Simulations
Luminescent nano‐thermometry is a fast‐developing technique with great potential for in vivo sensing, diagnosis, and therapy. Unfortunately, it presents serious limitations. The luminescence generated by nanothermometers, from which thermal readout is obtained, is strongly distorted by the attenuation induced by tissues. Such distortions lead to low signal levels and entangle absolute and reliable thermal monitoring of internal organs. Overcoming both limitations requires the use of high‐brightness luminescent nanothermometers and adopting more complex approaches for temperature estimation. In this work, it is demonstrated how superbright Ag2S nanothermometers can provide in vivo, reliable, and absolute thermal reading of the liver during laser‐induced hyperthermia. For that, a new procedure is designed in which thermal readout is obtained from the combination of in vivo transient thermometry measurements and in silico simulations. The synergy between in vivo and in silico measurements has made it possible to assess relevant numbers such as the efficiency of hyperthermia processes, the total heat energy deposited in the liver, and the relative contribution of Ag2S nanoparticles to liver heating. This work provides a new way for absolute thermal sensing of internal organs with potential application not only to hyperthermia processes but also to advanced diagnosis and therapy.
- Open Access
- 1 January 2021
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 38 (1) , 846-861
In silico assessment of collateral eddy current heating in biocompatible implants subjected to magnetic hyperthermia treatments
Purpose: Bearing partially or fully metallic passive implants represents an exclusion criterion for patients undergoing a magnetic hyperthermia procedure, but there are no specific studies backing this restrictive decision. This work assesses how the secondary magnetic field generated at the surface of two common types of prostheses affects the safety and efficiency of magnetic hyperthermia treatments of localized tumors. The paper also proposes the combination of a multi-criteria decision analysis and a graphical representation of calculated data as an initial screening during the preclinical risk assessment for each patient. Materials and methods: Heating of a hip joint and a dental implant during the treatment of prostate, colorectal and head and neck tumors have been assessed considering different external field conditions and exposure times. The Maxwell equations including the secondary field produced by metallic prostheses have been solved numerically in a discretized computable human model. The heat exchange problem has been solved through a modified version of the Pennes' bioheat equation assuming a temperature dependency of blood perfusion and metabolic heat, i.e. thermorregulation. The degree of risk has been assessed using a risk index with parameters coming from custom graphs plotting the specific absorption rate (SAR) vs temperature increase, and coefficients derived from a multi-criteria decision analysis performed following the MACBETH approach. Results: The comparison of two common biomaterials for passive implants - Ti6Al4V and CoCrMo - shows that both specific absorption rate (SAR) and local temperature increase are found to be higher for the hip prosthesis made by Ti6Al4V despite its lower electrical and thermal conductivity. By tracking the time evolution of temperature upon field application, it has been established that there is a 30 s delay between the time point for which the thermal equilibrium is reached at prostheses and tissues. Likewise, damage may appear in those tissues adjacent to the prostheses at initial stages of treatment, since recommended thermal thresholds are soon surpassed for higher field intensities. However, it has also been found that under some operational conditions the typical safety rule of staying below or attain a maximum temperature increase or SAR value is met. Conclusion: The current exclusion criterion for implant-bearing patients in magnetic hyperthermia should be revised, since it may be too restrictive for a range of the typical field conditions used. Systematic in silico treatment planning using the proposed methodology after a well-focused diagnostic procedure can aid the clinical staff to find the appropriate limits for a safe treatment window. Graphical Abstract
- 1 January 2021
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 38 (1) , 846-861
Open AccessIn silico assessment of collateral eddy current heating in biocompatible implants subjected to magnetic hyperthermia treatments
Purpose: Bearing partially or fully metallic passive implants represents an exclusion criterion for patients undergoing a magnetic hyperthermia procedure, but there are no specific studies backing this restrictive decision. This work assesses how the secondary magnetic field generated at the surface of two common types of prostheses affects the safety and efficiency of magnetic hyperthermia treatments of localized tumors. The paper also proposes the combination of a multi-criteria decision analysis and a graphical representation of calculated data as an initial screening during the preclinical risk assessment for each patient. Materials and methods: Heating of a hip joint and a dental implant during the treatment of prostate, colorectal and head and neck tumors have been assessed considering different external field conditions and exposure times. The Maxwell equations including the secondary field produced by metallic prostheses have been solved numerically in a discretized computable human model. The heat exchange problem has been solved through a modified version of the Pennes' bioheat equation assuming a temperature dependency of blood perfusion and metabolic heat, i.e. thermorregulation. The degree of risk has been assessed using a risk index with parameters coming from custom graphs plotting the specific absorption rate (SAR) vs temperature increase, and coefficients derived from a multi-criteria decision analysis performed following the MACBETH approach. Results: The comparison of two common biomaterials for passive implants - Ti6Al4V and CoCrMo - shows that both specific absorption rate (SAR) and local temperature increase are found to be higher for the hip prosthesis made by Ti6Al4V despite its lower electrical and thermal conductivity. By tracking the time evolution of temperature upon field application, it has been established that there is a 30 s delay between the time point for which the thermal equilibrium is reached at prostheses and tissues. Likewise, damage may appear in those tissues adjacent to the prostheses at initial stages of treatment, since recommended thermal thresholds are soon surpassed for higher field intensities. However, it has also been found that under some operational conditions the typical safety rule of staying below or attain a maximum temperature increase or SAR value is met. Conclusion: The current exclusion criterion for implant-bearing patients in magnetic hyperthermia should be revised, since it may be too restrictive for a range of the typical field conditions used. Systematic in silico treatment planning using the proposed methodology after a well-focused diagnostic procedure can aid the clinical staff to find the appropriate limits for a safe treatment window. Graphical Abstract
- 6 September 2018
- Published by Wiley in Advanced Functional Materials
- Vol. 28 (43)
In Vivo Early Tumor Detection and Diagnosis by Infrared Luminescence Transient Nanothermometry
The development of technologies capable of early tumor detection is unquestionably demanded by physicians, as early diagnosis is key to achieve more efficient and less invasive treatments with improved outcomes. At the preclinical level, nanotechnology has already provided innovative solutions for tumor imaging and therapy, but it has failed to provide real early tumor diagnosis. In this work, an infrared nanothermometry‐based approach toward early melanoma detection, based on the changes produced in the thermal relaxation dynamics of tissues as the tumor develops, is introduced. In vivo experiments demonstrate that detection of incipient tumors from their very onset is possible through monitoring changes in their thermal relaxation dynamics using Ag2S infrared luminescent nanothermometers. For a total tumor development time of 14 days, luminescence nanothermometry allows tumor detection 6 days before its presence is evident by visual inspection. Simultaneous study of the tumoral vasculature reveals that the premature variation in the thermal relaxation dynamics is a consequence of the interplay between tumor angiogenesis and necrosis during the different tumor development stages.
- 6 September 2018
- Published by Wiley in Advanced Functional Materials
- Vol. 28 (43)
In Vivo Early Tumor Detection and Diagnosis by Infrared Luminescence Transient Nanothermometry
The development of technologies capable of early tumor detection is unquestionably demanded by physicians, as early diagnosis is key to achieve more efficient and less invasive treatments with improved outcomes. At the preclinical level, nanotechnology has already provided innovative solutions for tumor imaging and therapy, but it has failed to provide real early tumor diagnosis. In this work, an infrared nanothermometry‐based approach toward early melanoma detection, based on the changes produced in the thermal relaxation dynamics of tissues as the tumor develops, is introduced. In vivo experiments demonstrate that detection of incipient tumors from their very onset is possible through monitoring changes in their thermal relaxation dynamics using Ag2S infrared luminescent nanothermometers. For a total tumor development time of 14 days, luminescence nanothermometry allows tumor detection 6 days before its presence is evident by visual inspection. Simultaneous study of the tumoral vasculature reveals that the premature variation in the thermal relaxation dynamics is a consequence of the interplay between tumor angiogenesis and necrosis during the different tumor development stages.