Nahid Imtiaz Masuk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nahid Imtiaz Masuk has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bahman Shabani
School of Engineering RMIT University Bundoora Victoria Australia
1 shared publication - Huy Quoc Nguyen
The University of Danang—University of Science and Technology
1 shared publication Khodadad Mostakim
Department of Mechanical Engineering, Rajshahi University of Engineering & Technology, Kazla, Rajshahi 6204, Bangladesh
1 shared publication- Monjur Mourshed
Mechanical and Automotive Engineering, School of Engineering, RMIT University, Bundoora 3083, Australia
1 shared publication Shithi Dey Kanka
Department of Mechanical Engineering, Rajshahi University of Engineering & Technology, Kazla, Rajshahi 6204, Bangladesh
1 shared publication
Latest Publications
- Open Access
An Experimental Approach to Energy and Exergy Analyses of a Hybrid PV/T System with Simultaneous Water and Air Cooling
In this paper, the effects of simultaneous air and water cooling on the energy performances of a single-pass hybrid PV/T system are experimentally investigated. Both air and water are used as coolants and are tested at four different mass flow rates, ranging from 0.0014 to 0.0026 kg/s. It is found that the overall efficiency of the PV/T system is dependent on the solar intensity and mass flow rate of coolants. Maximum PV/T system efficiency is found to be 62.2% for a simultaneous flow of water and air at a 0.0026 kg/s flow rate, which is 35.5% higher than the efficiency found at 0.0014 kg/s coolant flow rate. Maximum thermal energy outputs are 85.8 and 211.84 W/m2 while using air- and water-based coolants, respectively. Exergy analysis of the developed system indicates that exergy efficiency increased by up to two times by introducing simultaneous air and water cooling in this PV/T system.
Open AccessAn Experimental Approach to Energy and Exergy Analyses of a Hybrid PV/T System with Simultaneous Water and Air Cooling
In this paper, the effects of simultaneous air and water cooling on the energy performances of a single-pass hybrid PV/T system are experimentally investigated. Both air and water are used as coolants and are tested at four different mass flow rates, ranging from 0.0014 to 0.0026 kg/s. It is found that the overall efficiency of the PV/T system is dependent on the solar intensity and mass flow rate of coolants. Maximum PV/T system efficiency is found to be 62.2% for a simultaneous flow of water and air at a 0.0026 kg/s flow rate, which is 35.5% higher than the efficiency found at 0.0014 kg/s coolant flow rate. Maximum thermal energy outputs are 85.8 and 211.84 W/m2 while using air- and water-based coolants, respectively. Exergy analysis of the developed system indicates that exergy efficiency increased by up to two times by introducing simultaneous air and water cooling in this PV/T system.
- 5 March 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (6) , 4644-4669
Performance and Emission Characteristic Analysis of a Gasoline Engine Utilizing Different Types of Alternative Fuels: A Comprehensive Review
- 5 March 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (6) , 4644-4669
Performance and Emission Characteristic Analysis of a Gasoline Engine Utilizing Different Types of Alternative Fuels: A Comprehensive Review