PRPrabhakar Ramachandran

Prabhakar Ramachandran

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Prabhakar Ramachandran has a total of 64 co-authors. Here are the top co-authors by number of shared publications:

  • Ben Perrett

    Department of Radiation Oncology, Cancer Services, Princess Alexandra Hospital, Woolloongabba, Queensland, Australia

    4 shared publications
  • Daniel Arrington

    Department of Radiation Oncology, Cancer Services, Princess Alexandra Hospital, Queensland, Australia

    4 shared publications
  • Margot Lehman

    Department of Radiation Oncology, Cancer Services, Princess Alexandra Hospital, Woolloongabba, Australia

    4 shared publications
  • Matthew Foote

    Department of Radiation Oncology, Princess Alexandra Hospital, Woolloongabba, Queensland 4102, Australia

    4 shared publications
  • Akash Mehta

    Department of Radiation Oncology, Princess Alexandra Hospital, Woolloongabba, Queensland 4102, Australia

    3 shared publications
  • Andrew Fielding

    School of Chemistry and Physics, Queensland University of Technology, Brisbane, Queensland, Australia

    3 shared publications

Latest Publications

  • Open Access

    Synthetic MRI from radiotherapy planning CT images for Head‐and‐Neck Cancer

    by Prabhakar Ramachandran, Akshay C Dhargave, Catherine Jones, Dionee Liefman, Lachlan McDowell, Howard Liu

    Background: Computed Tomography (CT) provides geometric accuracy and electron density information essential for radiotherapy planning; however, it offers limited soft‐tissue contrast. Magnetic Resonance Imaging (MRI) improves tumor visualization but introduces registration uncertainties when acquired separately from the radiotherapy planning CT (pCT). Cross‐modality image synthesis enables the generation of synthetic MRI (sMRI) directly from pCT and may combine the strengths of both modalities, reducing reliance on MRI access. Purpose: We propose a two‐stage deep‐learning framework for generating sMRI from pCT image‐sets specifically in head‐and‐neck (H&N) cancers, providing soft‐tissue contrast comparable to ground‐truth MR images (gtMRI). Methods: This study included 60 patient cases with H&N cancer treated with radical radiotherapy between March 2022 and April 2024 for model development (50 for training, 10 for validation), plus 10 additional cases, independent of the development cohort for testing. All patients underwent a standard, non‐contrast pCT scan followed by an MRI acquired on a 3T Siemens MR simulator. Images were deformably‐registered, yielding 10,000 matched CT–MRI slice‐pairs for model training. The proposed model utilizes a two‐stage architecture, a Pix2Pix conditional generative adversarial network (GAN) for coarse sMRI synthesis, followed by a conditional diffusion model for refinement. To test the model's robustness, 10 patient cases with both pCT and contrast‐enhanced CT (ceCT) were used to generate sMRI. Model performance was assessed using structural similarity index (SSIM), multi‐scale structural similarity index (MS‐SSIM), mean absolute error (MAE), and peak signal‐to‐noise ratio (PSNR). In addition, the geometric agreement of the primary (GTVp_70) and nodal (GTVn_70) gross tumor volumes delineated on sMRI vs. gtMRI was independently assessed by two radiation oncologists (ROs) using the Dice similarity coefficient (DSC), 95 th ‐percentile Hausdorff distance (HD95), and average symmetric surface distance (ASSD). Results: The average MS‐SSIM, SSIM, MAE and PSNR for pCT‐derived sMRI were 0.82 ± 0.02, 0.70 ± 0.03, 0.05 ± 0.01, and 20.42 ± 0.66 dB, respectively. The mean MS‐SSIM and SSIM values for ceCT‐derived sMRI were 0.02 lower than those for the corresponding pCT‐to‐sMRI metrics. For the contour‐based evaluation, sMRI‐derived GTV contours achieved a mean DSC of 0.56 and 0.60 for GTVp_70, and 0.72 and 0.74 for GTVn_70 across the two ROs, relative to gtMRI contours. Conclusion: Our proof‐of‐concept study demonstrates the feasibility of pCT‐derived sMRI for H&N cancers using a deep‐learning framework. The model produces grayscale patterns and soft‐tissue contrast that closely resemble the gtMRI.

  • Open Access

    A conical-reflector scintillation device for 3-dimensional measurement of radiotherapy beams: a feasibility study

    by Benjamin Broadhead, Scott Crowe, Tanya Kairn, Samuel Peet, Andrew Fielding, Timothy Moroney, Prabhakar Ramachandran, Jamie Trapp

    This study presents a novel optical dosimetry system designed to support three-dimensional characterisation of radiotherapy beams using a single-camera imaging geometry. The system combines a large-volume cylindrical plastic scintillator with a conical reflector, enabling scintillation light emitted during beam irradiation to be captured as both direct emission and secondary reflection arcs using a single camera. These reflected signals encode spatial information about the beam’s position, size, and intensity, forming the basis for extracting clinically relevant parameters such as beam geometry and intensity from a single 2D image. Controlled experiments using a 6 MV photon beam investigated the system’s response to changes in beam position, lateral width, and penumbra shape. Analysis of reflection arc geometry and intensity demonstrated strong linear correlations between beam position and arc radius over lateral and longitudinal shifts of up to 60 mm and 70 mm respectively, and a clear non-linear relationship between the average arc intensity and lateral beam field widths between 10 and 80 mm. Additionally, penumbra widths derived from reflection arc profiles were linearly proportional to those measured directly in the scintillator, with the arc penumbra approximately $$\:4.9\:\pm\:\:1.8$$ times wider than the underlying scintillator observed beam penumbra. This proof-of-concept study demonstrated that reflection arc geometry and intensity in a single 2D image provided sufficient information to infer spatial beam position, lateral field width, and penumbra characteristics for static irradiations. The simplicity, symmetry, and static design of the system support future development towards volumetric beam reconstruction and, through sequential image acquisition, potentially time-resolved treatment verification.

  • Open Access

    An advanced automated pipeline for brain tumour segmentation on magnetic resonance imaging for gamma knife radiosurgery

    by Prabhakar Ramachandran, Akshay C Dhargave, Zachery M Colbert, Akash Mehta, Catherine Jones, Ryan Lusk, Michael Jenkins, Heath Foley, Mihir Shanker, Michael Huo, et al.


  • India—A Growing Hub for Global Education

    by Ajitha Haridasan, Mahalakshmi Sankar, Prabhakar Ramachandran, Jithin Benedict

  • Electron Beams

    by Tharmarnadar Ganesh, Prabhakar Ramachandran

  • Clinical Radiation Physics

    by Tharmarnadar Ganesh, Manoj K. Semwal, Prabhakar Ramachandran, Biplab Sarkar, Raghavendra Holla, Arjunan Manikandan

  • Teletherapy Technology and Principles

    by Biplab Sarkar, Prabhakar Ramachandran

  • Open Access

    Enhancing Gamma Knife Cone-beam Computed Tomography Image Quality Using Pix2pix Generative Adversarial Networks: A Deep Learning Approach

    by Prabhakar Ramachandran, Darcie Anderson, Zachery Colbert, Daniel Arrington, Michael Huo, Mark B Pinkham, Matthew Foote, Andrew Fielding

    Aims: The study aims to develop a modified Pix2Pix convolutional neural network framework to enhance the quality of cone-beam computed tomography (CBCT) images. It also seeks to reduce the Hounsfield unit (HU) variations, making CBCT images closely resemble the internal anatomy as depicted in computed tomography (CT) images. Materials and Methods: We used datasets from 50 patients who underwent Gamma Knife treatment to develop a deep learning model that translates CBCT images into high-quality synthetic CT (sCT) images. Paired CBCT and ground truth CT images from 40 patients were used for training and 10 for testing on 7484 slices of 512 × 512 pixels with the Pix2Pix model. The sCT images were evaluated against ground truth CT scans using image quality assessment metrics, including the structural similarity index (SSIM), mean absolute error (MAE), root mean square error (RMSE), peak signal-to-noise ratio (PSNR), normalized cross-correlation, and dice similarity coefficient. Results: The results demonstrate significant improvements in image quality when comparing sCT images to CBCT, with SSIM increasing from 0.85 ± 0.05 to 0.95 ± 0.03 and MAE dropping from 77.37 ± 20.05 to 18.81 ± 7.22 (p < 0.0001 for both). PSNR and RMSE also improved, from 26.50 ± 1.72 to 30.76 ± 2.23 and 228.52 ± 53.76 to 82.30 ± 23.81, respectively (p < 0.0001). Conclusion: The sCT images show reduced noise and artifacts, closely matching CT in HU values, and demonstrate a high degree of similarity to CT images, highlighting the potential of deep learning to significantly improve CBCT image quality for radiosurgery applications.


  • Open Access

    Repurposing traditional U-Net predictions for sparse SAM prompting in medical image segmentation

    by Zachery Morton Colbert, Daniel Arrington, Matthew Foote, Jonas Gårding, Dominik Fay, Michael Huo, Mark Pinkham, Prabhakar Ramachandran

    Objective: Automated medical image segmentation (MIS) using deep learning has traditionally relied on models built and trained from scratch, or at least fine-tuned on a target dataset. The Segment Anything Model (SAM) by Meta challenges this paradigm by providing zero-shot generalisation capabilities. This study aims to develop and compare methods for refining traditional U-Net segmentations by repurposing them for automated SAM prompting. Approach: A 2D U-Net with EfficientNet-B4 encoder was trained using 4-fold cross-validation on an in-house brain metastases dataset. Segmentation predictions from each validation set were used for automatic sparse prompt generation via a bounding box prompting method (BBPM) and novel implementations of the point prompting method (PPM). The PPMs frequently produced poor slice predictions (PSPs) that required identification and substitution. A slice was identified as a PSP if it (1) contained multiple predicted regions per lesion or (2) possessed outlier foreground pixel counts relative to the patient’s other slices. Each PSP was substituted with a corresponding initial U-Net or SAM BBPM prediction. The patients’ mean volumetric dice similarity coefficient (DSC) was used to evaluate and compare the methods’ performances. Main results: Relative to the initial U-Net segmentations, the BBPM improved mean patient DSC by 3.93 ± 1.48% to 0.847 ± 0.008 DSC. PSPs constituted 20.01–21.63% of PPMs’ predictions and without substitution performance dropped by 82.94 ± 3.17% to 0.139 ± 0.023 DSC. Pairing the two PSP identification techniques yielded a sensitivity to PSPs of 92.95 ± 1.20%. By combining this approach with BBPM prediction substitution, the PPMs achieved segmentation accuracies on par with the BBPM, improving mean patient DSC by up to 4.17 ± 1.40% and reaching 0.849 ± 0.007 DSC. Significance: The proposed PSP identification and substitution techniques bridge the gap between PPM and BBPM performance for MIS. Additionally, the uniformity observed in our experiments’ results demonstrates the robustness of SAM to variations in prompting style. These findings can assist in the design of both automatically and manually prompted pipelines.


  • Open Access

    PAHPhysRAD: A Digital Imaging and Communications in Medicine Research Tool for Segmentation and Radiomic Feature Extraction

    by Daniel Arrington, Ryan Motley, Zachery Morton Colbert, Margot Lehman, Prabhakar Ramachandran

    Introduction: Segmentation and analysis of organs at risks (OARs) and tumor volumes are integral concepts in the development of radiotherapy treatment plans and prediction of patients’ treatment outcomes. Aims: To develop a research tool, PAHPhysRAD, that can be used to semi- and fully automate segmentation of OARs. In addition, the proposed software seeks to extract 3214 radiomic features from tumor volumes and user-specified dose-volume parameters. Materials and Methods: Developed within MATLAB, PAHPhysRAD provides a comprehensive suite of segmentation tools, including manual, semi-automatic, and automatic options. For semi-autosegmentation, meta AI’s Segment Anything Model was incorporated using the bounding box methods. Autosegmentation of OARs and tumor volume are implemented through a module that enables the addition of models in Open Neural Network Exchange format. To validate the radiomic feature extraction module in PAHPhysRAD, radiomic features extracted from gross tumor volume of 15 non-small cell lung carcinoma patients were compared against the features extracted from 3D Slicer™. The dose-volume parameters extraction module was validated using the dose volume data extracted from 28 tangential field-based breast treatment planning datasets. The volume receiving ≥20 Gy (V20) for ipsilateral lung and the mean doses received by the heart and ipsilateral lung, were compared against the parameters extracted from Eclipse. Results: The Wilcoxon signed-rank test revealed no significant difference between the majority of the radiomic features derived from PAHPhysRAD and 3D Slicer. The average mean lung and heart doses calculated in Eclipse were 5.51 ± 2.28 Gy and 1.64 ± 1.98 Gy, respectively. Similarly, the average mean lung and heart doses calculated in PAHPhysRAD were 5.45 ± 2.89 Gy and 1.67 ± 2.08 Gy, respectively. Conclusion: The MATLAB-based graphical user interface, PAHPhysRAD, offers a user-friendly platform for viewing and analyzing medical scans with options to extract radiomic features and dose-volume parameters. Its versatility, compatibility, and potential for further development make it an asset in medical image analysis.