Paul Kunnel Brince
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Paul Kunnel Brince has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Danick Briand
Ecole Polytechnique Fédérale de Lausanne (EPFL), Soft Transducers Laboratory (LMTS), Rue de la Maladière 71b, Neuchâtel, Switzerland.
2 shared publications - Cecilia Jiménez-Jorquera
Instituto de Microelectrnica de Barcelona (IMB-CNM),CSIC,Barcelona,Spain
1 shared publication Céline Lafaye
Sports Medicine Unit Swiss Olympic Medical Center Division of Physical Medicine and Rehabilitation Centre hospitalier universitaire vaudois (CHUV) Lausanne 1011 Switzerland
1 shared publication- César Fernández-Sánchez
Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Spain
1 shared publication Mathieu Saubade
Sports Medicine Unit Swiss Olympic Medical Center Division of Physical Medicine and Rehabilitation Centre hospitalier universitaire vaudois (CHUV) Lausanne 1011 Switzerland
1 shared publication- Meritxell Rovira
Instituto de Microelectrónica de Barcelona (IMB-CNM, CSIC), Campus UAB, 08193 Cerdanyola, Spain
1 shared publication
Latest Publications
- Open Access
- 17 May 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 6 (1) , 78
Multisensing Wearable Technology for Sweat Biomonitoring
This work describes a multisensing wearable platform for monitoring biomarkers in sweat during the practice of exercise. Five electrochemical sensors for pH, potassium, sodium, chloride, and lactate were implemented in a flexible patch approach, together with a paper microfluidic component, to continuously measure sweat composition. The sensors are fabricated with silicon technologies: ion selective field effect transistors (ISFETs) for pH and ionic species; and a gold thin-film microelectrode for lactate. The latter includes a polymeric membrane based on an electropolymerized polypyrroled structure, where all the biocomponents required for carrying out the lactate analyses are entrapped. The flexible patch is fabricated using hybrid integration technologies, including printed pads defined on a polyimide (Kapton®) substrate and wire bonding encapsulation of silicon chips. To fix and align the sensors to the flexible substrate, different laminated materials, such as polymethyl methacrylate (PMMA), polydimethylsiloxane (PDMS), and silicone-based adhesive, were used. The first results show good performance of the sensors—ISFETS sensitivity between 54–59 mV dec−1 for ion ranges in sweat from 2 to 100 mM and lactate sensor sensitivity of −135 × 102 µA M−1 cm−2 for the range of 2–50 mM. The microfluidic platform has been tested in terms of adequate sensor wettability and rapid response during the time span of exercise activity (2 h) showing excellent results.
- 17 May 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 6 (1) , 78
Open AccessMultisensing Wearable Technology for Sweat Biomonitoring
This work describes a multisensing wearable platform for monitoring biomarkers in sweat during the practice of exercise. Five electrochemical sensors for pH, potassium, sodium, chloride, and lactate were implemented in a flexible patch approach, together with a paper microfluidic component, to continuously measure sweat composition. The sensors are fabricated with silicon technologies: ion selective field effect transistors (ISFETs) for pH and ionic species; and a gold thin-film microelectrode for lactate. The latter includes a polymeric membrane based on an electropolymerized polypyrroled structure, where all the biocomponents required for carrying out the lactate analyses are entrapped. The flexible patch is fabricated using hybrid integration technologies, including printed pads defined on a polyimide (Kapton®) substrate and wire bonding encapsulation of silicon chips. To fix and align the sensors to the flexible substrate, different laminated materials, such as polymethyl methacrylate (PMMA), polydimethylsiloxane (PDMS), and silicone-based adhesive, were used. The first results show good performance of the sensors—ISFETS sensitivity between 54–59 mV dec−1 for ion ranges in sweat from 2 to 100 mM and lactate sensor sensitivity of −135 × 102 µA M−1 cm−2 for the range of 2–50 mM. The microfluidic platform has been tested in terms of adequate sensor wettability and rapid response during the time span of exercise activity (2 h) showing excellent results.
- 5 March 2021
- Published by Wiley in Advanced Materials Technologies
- Vol. 6 (4) , 2000910
Printed Iontophoretic‐Integrated Wearable Microfluidic Sweat‐Sensing Patch for On‐Demand Point‐Of‐Care Sweat Analysis
In recent years, wearable epidermal sweat sensors have received extensive attention owing to their great potential to provide personalized information on the health status of individuals at the molecular level. For on‐demand medical analysis of sweat in sedentary conditions, a cost‐effective wearable integrated platform combining sweat stimulation, sampling, transport, and analysis is highly desirable. In this work, a printed iontophoretic system integrated into a microfluidic sensing platform, which combines sweat induction, collection, and real‐time analysis of sweat‐ions into a single patch for on‐demand sweat monitoring on human subjects in stationary conditions is reported. The incorporation of microfluidics features facilitates sweat sampling, collection, and guiding through capillary effect. The multisensing sensor array exhibits sensitivity close to Nernstian behavior for sodium, potassium, and pH. The correlation between the concentrations of ions measured with the sweat patch and with ion chromatography analysis demonstrates the applicability of the system for real‐time point‐of‐care monitoring of the health status of individuals. Furthermore, the sweat patch electronic interface with wireless transmission enables real‐time data monitoring and storage over a cloud platform. This printed iontophoretic‐integrated fluidic sweat patch provides a cost‐effective solution for the on‐demand analysis of sweat components for healthcare applications.
- 5 March 2021
- Published by Wiley in Advanced Materials Technologies
- Vol. 6 (4) , 2000910
Printed Iontophoretic‐Integrated Wearable Microfluidic Sweat‐Sensing Patch for On‐Demand Point‐Of‐Care Sweat Analysis
In recent years, wearable epidermal sweat sensors have received extensive attention owing to their great potential to provide personalized information on the health status of individuals at the molecular level. For on‐demand medical analysis of sweat in sedentary conditions, a cost‐effective wearable integrated platform combining sweat stimulation, sampling, transport, and analysis is highly desirable. In this work, a printed iontophoretic system integrated into a microfluidic sensing platform, which combines sweat induction, collection, and real‐time analysis of sweat‐ions into a single patch for on‐demand sweat monitoring on human subjects in stationary conditions is reported. The incorporation of microfluidics features facilitates sweat sampling, collection, and guiding through capillary effect. The multisensing sensor array exhibits sensitivity close to Nernstian behavior for sodium, potassium, and pH. The correlation between the concentrations of ions measured with the sweat patch and with ion chromatography analysis demonstrates the applicability of the system for real‐time point‐of‐care monitoring of the health status of individuals. Furthermore, the sweat patch electronic interface with wireless transmission enables real‐time data monitoring and storage over a cloud platform. This printed iontophoretic‐integrated fluidic sweat patch provides a cost‐effective solution for the on‐demand analysis of sweat components for healthcare applications.