Nikhil S. Chandra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nikhil S. Chandra has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Daniel W. Moran
Washington University
1 shared publication - Jawad M. Khalifeh
Department of Neurological Surgery, Washington University School of Medicine, St. Louis, USA
1 shared publication - John Matthew Felder
From the Division of Plastic and Reconstructive Surgery, Department of Surgery, Washington University in St. Louis School of Medicine, St. Louis, Mo
1 shared publication Leonard Green
Department of Psychological and Brain Sciences, Washington University in St. Louis, 1 Brookings Drive, St. Louis, MO 63130, USA
1 shared publicationMatthew R. MacEwan
Department of Neurosurgery, Washington University School of Medicine in St. Louis, 660S. Euclid Ave, St. Louis, MO 63110, USA
1 shared publication- Matthew R. MacEwan
Department of Neurosurgery, Washington University School of Medicine, St. Louis, MO 63110, USA
1 shared publication
Latest Publications
- 16 February 2022
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 371, 109528
A custom interface for the joint operation of Med Associates and Tucker-Davis Technologies hardware in a rodent behavioral model
- 16 February 2022
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 371, 109528
A custom interface for the joint operation of Med Associates and Tucker-Davis Technologies hardware in a rodent behavioral model
- Open Access
- 6 March 2021
- Published by Springer Nature in Cureus
- Vol. 13 (3)
High-Frequency Alternating Current Block Using Macro-Sieve Electrodes: A Pilot Study
High-frequency alternating current (HFAC) can yield a rapid-acting and reversible nerve conduction block. The present study aimed to demonstrate the successful implementation of HFAC block delivery via regenerative macro-sieve electrodes (MSEs). Dual-electrode assemblies in two configurations [dual macro-sieve electrode-1 (DMSE-I), DMSE-II] were fabricated from pairs of MSEs and implanted in the transected and subsequently repaired sciatic nerves of two male Lewis rats. After four months of postoperative nerve regeneration through the MSEs' transit zones, the efficacy of acute HFAC block was tested for both configurations. Frequencies ranging from 10 kHz to 42 kHz, and stimulus amplitudes with peak-to-peak voltages ranging from 2 V to 20 V were tested. Evoked muscle force measurement was used to quantify the nerve conduction block. HFAC stimulation delivered via DMSE assemblies obtained a complete block at frequencies of 14 to 26 kHz and stimulus amplitudes of 12 to 20 V p-p. The threshold voltage for the complete block showed an approximately linear dependence on frequency. The threshold voltage for the partial conduction block was also approximately linear. For those frequencies that displayed both partial and complete block, the partial block thresholds were consistently lower. This study provides a proof of concept that regenerative MSEs can achieve complete and reversible conduction block via HFAC stimulation of regenerated nerve tissue. A chronically interfaced DMSE assembly may thereby facilitate the inactivation of targeted nerves in cases wherein pathologic neuronal hyperactivity is involved.
- 6 March 2021
- Published by Springer Nature in Cureus
- Vol. 13 (3)
Open AccessHigh-Frequency Alternating Current Block Using Macro-Sieve Electrodes: A Pilot Study
High-frequency alternating current (HFAC) can yield a rapid-acting and reversible nerve conduction block. The present study aimed to demonstrate the successful implementation of HFAC block delivery via regenerative macro-sieve electrodes (MSEs). Dual-electrode assemblies in two configurations [dual macro-sieve electrode-1 (DMSE-I), DMSE-II] were fabricated from pairs of MSEs and implanted in the transected and subsequently repaired sciatic nerves of two male Lewis rats. After four months of postoperative nerve regeneration through the MSEs' transit zones, the efficacy of acute HFAC block was tested for both configurations. Frequencies ranging from 10 kHz to 42 kHz, and stimulus amplitudes with peak-to-peak voltages ranging from 2 V to 20 V were tested. Evoked muscle force measurement was used to quantify the nerve conduction block. HFAC stimulation delivered via DMSE assemblies obtained a complete block at frequencies of 14 to 26 kHz and stimulus amplitudes of 12 to 20 V p-p. The threshold voltage for the complete block showed an approximately linear dependence on frequency. The threshold voltage for the partial conduction block was also approximately linear. For those frequencies that displayed both partial and complete block, the partial block thresholds were consistently lower. This study provides a proof of concept that regenerative MSEs can achieve complete and reversible conduction block via HFAC stimulation of regenerated nerve tissue. A chronically interfaced DMSE assembly may thereby facilitate the inactivation of targeted nerves in cases wherein pathologic neuronal hyperactivity is involved.