Bolette Hestbek Nicolaisen
Bolette Hestbek Nicolaisen has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Ida Vogel
Department of Clinical Medicine Aarhus University Aarhus Denmark
3 shared publications Inga Baasch Christensen
ARCEDI Biotech Vejle Denmark
3 shared publications- Lotte Hatt
ARCEDI Biotech Vejle Denmark
3 shared publications - Niels Uldbjerg
Department of Clinical Medicine Aarhus University Aarhus Denmark
3 shared publications - Ripudaman Singh
ARCEDI Biotech Vejle Denmark
3 shared publications Helle Mogensen
Department of Obstetrics and Gynecology Kolding Hospital Kolding Denmark
2 shared publications
Latest Publications
- Open Access
- 8 July 2026
- Published by Wiley in Prenatal Diagnosis
- Vol. 46 (10) , 1536-1542
Novel and High‐Throughput Method of Isolating Single Fetal Cells Using FACS for NIPT
Objective: To evaluate fluorescence activated cell sorting (FACS) as a method of single‐cell isolation of rare circulating fetal cells from maternal blood for use in cell‐based non‐invasive prenatal testing (cbNIPT). Method: Blood samples (30 mL) were collected from 75 ‘low‐risk’ pregnant women (gestational age 10–15 weeks). Fetal cells were enriched and stained using magnetic activated cell sorting. Following enrichment, single fetal cells were sorted in individual PCR tubes by FACS. After cell lysis, verification of fetal cell origin was performed using short tandem repeat (STR) analysis with the GlobalFiler PCR Amplification kit. Results: An average of 13.7 cells were sorted using FACS. STR analysis identified 8.2 fetal cells on average, representing 60.2% of the sorted cells. The four‐step single‐cell isolation procedure facilitated an overall enrichment of approximately 16‐million‐fold. One sample did not render any fetal cell, corresponding to 1.3% of the samples. Conclusion: FACS, which is typically used for segregation of large populations of cells, can be used for single‐cell isolation of rare fetal cells in an automated setup. This not only helps in making cell isolation faster and high throughput but also provides fetal cells for a more comprehensive genetic analysis of the fetus.
- 8 July 2026
- Published by Wiley in Prenatal Diagnosis
- Vol. 46 (10) , 1536-1542
Open AccessNovel and High‐Throughput Method of Isolating Single Fetal Cells Using FACS for NIPT
Objective: To evaluate fluorescence activated cell sorting (FACS) as a method of single‐cell isolation of rare circulating fetal cells from maternal blood for use in cell‐based non‐invasive prenatal testing (cbNIPT). Method: Blood samples (30 mL) were collected from 75 ‘low‐risk’ pregnant women (gestational age 10–15 weeks). Fetal cells were enriched and stained using magnetic activated cell sorting. Following enrichment, single fetal cells were sorted in individual PCR tubes by FACS. After cell lysis, verification of fetal cell origin was performed using short tandem repeat (STR) analysis with the GlobalFiler PCR Amplification kit. Results: An average of 13.7 cells were sorted using FACS. STR analysis identified 8.2 fetal cells on average, representing 60.2% of the sorted cells. The four‐step single‐cell isolation procedure facilitated an overall enrichment of approximately 16‐million‐fold. One sample did not render any fetal cell, corresponding to 1.3% of the samples. Conclusion: FACS, which is typically used for segregation of large populations of cells, can be used for single‐cell isolation of rare fetal cells in an automated setup. This not only helps in making cell isolation faster and high throughput but also provides fetal cells for a more comprehensive genetic analysis of the fetus.
- Open Access
- 25 May 2023
- Published by Wiley in Prenatal Diagnosis
- Vol. 43 (7) , 854-864
How does cell‐based non‐invasive prenatal test (NIPT) perform against chorionic villus sampling and cell‐free NIPT in detecting trisomies and copy number variations? A clinical study from Denmark
Objectives: We aimed to compare cell‐based NIPT (cbNIPT) to chorionic villus sampling (CVS) and to examine the test characteristics of cbNIPT in the first clinical validation study of cbNIPT compared to cell‐free NIPT (cfNIPT).Material and Methods: Study 1: Women (N = 92) who accepted CVS were recruited for cbNIPT (53 normal and 39 abnormal). Samples were analyzed with chromosomal microarray (CMA). Study 2: Women (N = 282) who accepted cfNIPT were recruited for cbNIPT. cfNIPT was analyzed using sequencing and cbNIPT by CMA.Results: Study 1: cbNIPT detected all aberrations (32/32) found in CVS: trisomies 13, 18 and 21 (23/23), pathogenic copy number variations (CNVs) (6/6) and sex chromosome aberrations (3/3). cbNIPT detected 3/8 cases of mosaicism in the placenta. Study 2: cbNIPT detected all trisomies found with cfNIPT (6/6) and had no false positive (0/246). One of the three CNVs called by cbNIPT was confirmed by CVS but was undetected by cfNIPT, two were false positives. cbNIPT detected mosaicism in five samples, of which two were not detected by cfNIPT. cbNIPT failed in 7.8% compared to 2.8% in cfNIPT.Conclusion: Circulating trophoblasts in the maternal circulation provide the potential of screening for aneuploidies and pathogenic CNVs covering the entire fetal genome.
- 25 May 2023
- Published by Wiley in Prenatal Diagnosis
- Vol. 43 (7) , 854-864
Open AccessHow does cell‐based non‐invasive prenatal test (NIPT) perform against chorionic villus sampling and cell‐free NIPT in detecting trisomies and copy number variations? A clinical study from Denmark
Objectives: We aimed to compare cell‐based NIPT (cbNIPT) to chorionic villus sampling (CVS) and to examine the test characteristics of cbNIPT in the first clinical validation study of cbNIPT compared to cell‐free NIPT (cfNIPT).Material and Methods: Study 1: Women (N = 92) who accepted CVS were recruited for cbNIPT (53 normal and 39 abnormal). Samples were analyzed with chromosomal microarray (CMA). Study 2: Women (N = 282) who accepted cfNIPT were recruited for cbNIPT. cfNIPT was analyzed using sequencing and cbNIPT by CMA.Results: Study 1: cbNIPT detected all aberrations (32/32) found in CVS: trisomies 13, 18 and 21 (23/23), pathogenic copy number variations (CNVs) (6/6) and sex chromosome aberrations (3/3). cbNIPT detected 3/8 cases of mosaicism in the placenta. Study 2: cbNIPT detected all trisomies found with cfNIPT (6/6) and had no false positive (0/246). One of the three CNVs called by cbNIPT was confirmed by CVS but was undetected by cfNIPT, two were false positives. cbNIPT detected mosaicism in five samples, of which two were not detected by cfNIPT. cbNIPT failed in 7.8% compared to 2.8% in cfNIPT.Conclusion: Circulating trophoblasts in the maternal circulation provide the potential of screening for aneuploidies and pathogenic CNVs covering the entire fetal genome.
- Open Access
- 7 March 2021
- Published by Springer Nature in Journal of Assisted Reproduction and Genetics
- Vol. 38 (8) , 1959-1970
Cell-based non-invasive prenatal testing for monogenic disorders: confirmation of unaffected fetuses following preimplantation genetic testing
Purpose: Proof of concept of the use of cell-based non-invasive prenatal testing (cbNIPT) as an alternative to chorionic villus sampling (CVS) following preimplantation genetic testing for monogenic disorders (PGT-M). Method: PGT-M was performed by combined testing of short tandem repeat (STR) markers and direct mutation detection, followed by transfer of an unaffected embryo. Patients who opted for follow-up of PGT-M by CVS had blood sampled, from which potential fetal extravillous throphoblast cells were isolated. The cell origin and mutational status were determined by combined testing of STR markers and direct mutation detection using the same setup as during PGT. The cbNIPT results with respect to the mutational status were compared to those of genetic testing of the CVS. Results: Eight patients had blood collected between gestational weeks 10 and 13, from which 33 potential fetal cell samples were isolated. Twenty-seven out of 33 isolated cell samples were successfully tested (82%), of which 24 were of fetal origin (89%). This corresponds to a median of 2.5 successfully tested fetal cell samples per case (range 1–6). All fetal cell samples had a genetic profile identical to that of the transferred embryo confirming a pregnancy with an unaffected fetus, in accordance with the CVS results. Conclusion: These findings show that although measures are needed to enhance the test success rate and the number of cells identified, cbNIPT is a promising alternative to CVS. Trial registration number: N-20180001
- 7 March 2021
- Published by Springer Nature in Journal of Assisted Reproduction and Genetics
- Vol. 38 (8) , 1959-1970
Open AccessCell-based non-invasive prenatal testing for monogenic disorders: confirmation of unaffected fetuses following preimplantation genetic testing
Purpose: Proof of concept of the use of cell-based non-invasive prenatal testing (cbNIPT) as an alternative to chorionic villus sampling (CVS) following preimplantation genetic testing for monogenic disorders (PGT-M). Method: PGT-M was performed by combined testing of short tandem repeat (STR) markers and direct mutation detection, followed by transfer of an unaffected embryo. Patients who opted for follow-up of PGT-M by CVS had blood sampled, from which potential fetal extravillous throphoblast cells were isolated. The cell origin and mutational status were determined by combined testing of STR markers and direct mutation detection using the same setup as during PGT. The cbNIPT results with respect to the mutational status were compared to those of genetic testing of the CVS. Results: Eight patients had blood collected between gestational weeks 10 and 13, from which 33 potential fetal cell samples were isolated. Twenty-seven out of 33 isolated cell samples were successfully tested (82%), of which 24 were of fetal origin (89%). This corresponds to a median of 2.5 successfully tested fetal cell samples per case (range 1–6). All fetal cell samples had a genetic profile identical to that of the transferred embryo confirming a pregnancy with an unaffected fetus, in accordance with the CVS results. Conclusion: These findings show that although measures are needed to enhance the test success rate and the number of cells identified, cbNIPT is a promising alternative to CVS. Trial registration number: N-20180001