Andrew D. Posner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrew D. Posner has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Afshin A. Anoushiravani
Orthopedic Trauma Institute, Department of Orthopedic Surgery, University of California San Francisco, San Francisco, CA
3 shared publications - Eric Perloff
Department of Orthopedic Surgery, Albany Medical Center, Albany, NY, USA
3 shared publications - Ajith Malige
Cedars-Sinai Kerlan-Jobe Institute, Los Angeles, California, USA
2 shared publications Dave T. Huang
Department of Orthopaedic Surgery, Cedars-Sinai, Los Angeles, California, USA
2 shared publications- Hamza Murtaza
Division of Orthopaedic Surgery, Albany Medical Center, Albany, New York
2 shared publications - Ian D. Hutchinson
Division of Sports Medicine, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Massachusetts General Brigham, Boston, Massachusetts
2 shared publications
Latest Publications
- Open Access
- 4 February 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (2)
Bone Quality Positively Correlates With Biomechanical Strength of All-Suture Anchors Utilized in Biceps Tenodesis
Background: All-suture anchors (ASAs) are increasingly used in biceps tenodesis (BT), and their fixation strength may vary with cortical bone and surgical position. Defining the influence of bone mineral density (BMD) on ASA pullout strength and failure mode across the high bicipital groove (HG), low bicipital groove suprapectoral position (SUP), and subpectoral (SUB) positions may allow for optimal anchor placement. Hypothesis: ASA biomechanical characteristics at each region of the bicipital groove would improve with increasing regional BMD. Study Design: Controlled laboratory study. Methods: ASAs measuring 2.6 mm were inserted into the HG, SUP, and SUB positions of the bicipital groove of 12 cadaveric specimens. Local measures of bone quality around each anchor were evaluated using micro–computed tomography. Afterward, each ASA was biomechanically loaded to failure to determine the ultimate pullout strength and mode of failure. Repeated-measures correlations were calculated to determine the relationship between measures of bone quality and pullout strength. Results: Mean load to failure of ASAs placed in the HG, SUP, and SUB positions were 370.7 ± 111.2 N (95% CI, 300.0-441.3 N), 600.5 ± 120.8 N (95% CI, 523.8-677.3 N), and 668.1 ± 117.2 N (95% CI, 593.6-742.5 N), respectively. Mean load to failure of ASAs placed in the SUP and SUB positions was significantly greater than in the HG position ( P < .01). There was no significant difference in mean pullout force between the SUP and SUB positions. The most common mode of failure was anchor pullout in the HG (100%) and suture breakage in the SUP (58%) and SUB (75%) positions. Mean BMD and cortical BMD were significantly greater in the SUP and SUB positions compared to the HG position ( P < .05). Pullout force measured throughout the bicipital groove was significantly correlated to cortex mean bone density, cortex volume, mean BMD, and bone volume ( P < .01). Conclusion: ASA pullout strength was correlated with local cortical BMD. ASA fixation strength and BMD were robust in all tested regions of the bicipital groove but were greatest in the SUP and SUB positions. Clinical Relevance: ASAs can effectively be placed throughout the bicipital groove. ASAs in all 3 tested positions can withstand not only the force reportedly placed on the anchor by the native biceps but also the force previously reported to cause failure at the suture-biceps tendon interface. These biomechanical findings add to the growing clinical and basic science evidence supporting the use of ASA for BT.
- 4 February 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (2)
Open AccessBone Quality Positively Correlates With Biomechanical Strength of All-Suture Anchors Utilized in Biceps Tenodesis
Background: All-suture anchors (ASAs) are increasingly used in biceps tenodesis (BT), and their fixation strength may vary with cortical bone and surgical position. Defining the influence of bone mineral density (BMD) on ASA pullout strength and failure mode across the high bicipital groove (HG), low bicipital groove suprapectoral position (SUP), and subpectoral (SUB) positions may allow for optimal anchor placement. Hypothesis: ASA biomechanical characteristics at each region of the bicipital groove would improve with increasing regional BMD. Study Design: Controlled laboratory study. Methods: ASAs measuring 2.6 mm were inserted into the HG, SUP, and SUB positions of the bicipital groove of 12 cadaveric specimens. Local measures of bone quality around each anchor were evaluated using micro–computed tomography. Afterward, each ASA was biomechanically loaded to failure to determine the ultimate pullout strength and mode of failure. Repeated-measures correlations were calculated to determine the relationship between measures of bone quality and pullout strength. Results: Mean load to failure of ASAs placed in the HG, SUP, and SUB positions were 370.7 ± 111.2 N (95% CI, 300.0-441.3 N), 600.5 ± 120.8 N (95% CI, 523.8-677.3 N), and 668.1 ± 117.2 N (95% CI, 593.6-742.5 N), respectively. Mean load to failure of ASAs placed in the SUP and SUB positions was significantly greater than in the HG position ( P < .01). There was no significant difference in mean pullout force between the SUP and SUB positions. The most common mode of failure was anchor pullout in the HG (100%) and suture breakage in the SUP (58%) and SUB (75%) positions. Mean BMD and cortical BMD were significantly greater in the SUP and SUB positions compared to the HG position ( P < .05). Pullout force measured throughout the bicipital groove was significantly correlated to cortex mean bone density, cortex volume, mean BMD, and bone volume ( P < .01). Conclusion: ASA pullout strength was correlated with local cortical BMD. ASA fixation strength and BMD were robust in all tested regions of the bicipital groove but were greatest in the SUP and SUB positions. Clinical Relevance: ASAs can effectively be placed throughout the bicipital groove. ASAs in all 3 tested positions can withstand not only the force reportedly placed on the anchor by the native biceps but also the force previously reported to cause failure at the suture-biceps tendon interface. These biomechanical findings add to the growing clinical and basic science evidence supporting the use of ASA for BT.
- Open Access
- 14 October 2025
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 13 (10)
The Relationship Between Bone Quality and Biomechanical Strength of All-Suture Anchors Utilized in Rotator Cuff Repairs
Background: All-suture anchors (ASAs) are increasingly used in arthroscopic rotator cuff repair and rely on cortical bone for strength. No study has compared ASA pullout strength in relation to bone mineral density (BMD) in the different quadrants of the supraspinatus footprint on the greater tuberosity (GT). Hypothesis: ASA biomechanical characteristics at each quadrant would improve with increasing regional BMD. Study Design: Controlled laboratory study. Methods: Four 2.6-mm ASAs were inserted into the anteromedial, posteromedial, anterolateral, and posterolateral quadrants of the GT supraspinatus footprint of 12 cadaveric specimens. Local measures of bone quality around each anchor were evaluated using micro-computed tomography. Afterward, each ASA was biomechanically loaded to failure to determine the ultimate pullout strength and mode of failure. Repeated measures correlations were calculated to determine the relationship between measures of bone quality and pullout strength. Results: The mean load to failure of ASA placed in the posterolateral GT was significantly greater than all 3 of the other quadrants ( P < .01). There was no significant difference in mean pullout force in the posteromedial, anterolateral, and anteromedial quadrants. Cortical BMD and mean BMD were also significantly greater in the posterolateral corner ( P < .05). The pullout force measured across all quadrants was significantly correlated with cortex mean bone density, cortex volume, mean bone mineral density, and bone volume ( P < .01). Conclusion: ASA pullout strength is correlated with local cortical BMD. ASA fixation strength and BMD were robust in all quadrants on the GT, and were greatest in the posterolateral GT. Clinical Relevance: This finding expands the available geography for ASA placement by demonstrating that the lateral GT has adequate BMD to support ASAs.
- 14 October 2025
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 13 (10)
Open AccessThe Relationship Between Bone Quality and Biomechanical Strength of All-Suture Anchors Utilized in Rotator Cuff Repairs
Background: All-suture anchors (ASAs) are increasingly used in arthroscopic rotator cuff repair and rely on cortical bone for strength. No study has compared ASA pullout strength in relation to bone mineral density (BMD) in the different quadrants of the supraspinatus footprint on the greater tuberosity (GT). Hypothesis: ASA biomechanical characteristics at each quadrant would improve with increasing regional BMD. Study Design: Controlled laboratory study. Methods: Four 2.6-mm ASAs were inserted into the anteromedial, posteromedial, anterolateral, and posterolateral quadrants of the GT supraspinatus footprint of 12 cadaveric specimens. Local measures of bone quality around each anchor were evaluated using micro-computed tomography. Afterward, each ASA was biomechanically loaded to failure to determine the ultimate pullout strength and mode of failure. Repeated measures correlations were calculated to determine the relationship between measures of bone quality and pullout strength. Results: The mean load to failure of ASA placed in the posterolateral GT was significantly greater than all 3 of the other quadrants ( P < .01). There was no significant difference in mean pullout force in the posteromedial, anterolateral, and anteromedial quadrants. Cortical BMD and mean BMD were also significantly greater in the posterolateral corner ( P < .05). The pullout force measured across all quadrants was significantly correlated with cortex mean bone density, cortex volume, mean bone mineral density, and bone volume ( P < .01). Conclusion: ASA pullout strength is correlated with local cortical BMD. ASA fixation strength and BMD were robust in all quadrants on the GT, and were greatest in the posterolateral GT. Clinical Relevance: This finding expands the available geography for ASA placement by demonstrating that the lateral GT has adequate BMD to support ASAs.
- 23 September 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (4) , 956-964
The effect of pretreatment of the pilosebaceous unit on Cutibacterium acnes burden during shoulder arthroplasty: a randomized controlled trial
- 23 September 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (4) , 956-964
The effect of pretreatment of the pilosebaceous unit on Cutibacterium acnes burden during shoulder arthroplasty: a randomized controlled trial
- 1 October 2024
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 14 (4)
Fourteen-Year-Old Male Football Player with Lesser Tuberosity Avulsion Fracture: Open Transosseous Equivalent Suture Repair
Case: We report a case of a lesser tuberosity avulsion fracture in a 14-year-old adolescent boy who presented to Orthopaedic Urgent Care where he was promptly diagnosed after magnetic resonance imaging. The patient was successfully treated with an open transosseous equivalent suture repair 3 weeks after initial injury. Conclusion: The purpose of this case report was to advance the understanding of these injuries, enable appropriate diagnosis and treatment, and optimize patient's shoulder outcomes and return to sport.
- 1 October 2024
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 14 (4)
Fourteen-Year-Old Male Football Player with Lesser Tuberosity Avulsion Fracture: Open Transosseous Equivalent Suture Repair
Case: We report a case of a lesser tuberosity avulsion fracture in a 14-year-old adolescent boy who presented to Orthopaedic Urgent Care where he was promptly diagnosed after magnetic resonance imaging. The patient was successfully treated with an open transosseous equivalent suture repair 3 weeks after initial injury. Conclusion: The purpose of this case report was to advance the understanding of these injuries, enable appropriate diagnosis and treatment, and optimize patient's shoulder outcomes and return to sport.
- 18 June 2024
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 17 (3) , 308-315
Achievement of the patient acceptable symptom state following total shoulder arthroplasty with nonspherical humeral head and inlay glenoid
Background: Total shoulder arthroplasty (TSA) with a nonspherical humeral head component and inlay glenoid is a bone preserving treatment for glenohumeral arthritis. This study aims to describe minimum two year patient reported outcomes, patient acceptable symptomatic state (PASS) achievement, and complications following TSA with this prosthesis. Methods: A retrospective review of patients undergoing TSA with nonspherical humeral head and inlay glenoid was performed. Outcomes included Single Assessment Numeric Evaluation (SANE) scores, American Shoulder and Elbow Surgeons (ASES) scores, and complications. SANE and ASES scores were compared to established PASS threshold values to determine PASS achievement. Results: 56 TSA in 53 patients were identified. The mean age was 64.5 years, 64% were male, and mean follow-up was 29.2 ± 4.9 months (24.0–42.8). Two complications (3.6%) were observed: one subscapularis tear requiring revision to reverse TSA and one traumatic minimally displaced greater tuberosity fracture successfully treated nonoperatively. The mean SANE score was 84.3 ± 16.9 (40–100) and 77% of patients surpassed the PASS threshold of 75.5. The mean ASES score was 85.3 ± 15.7 (40–100) and 77% of patients surpassed the PASS threshold of 76. Discussion: Patients undergoing TSA with a nonspherical humeral head and inlay glenoid demonstrated high PASS achievement rates and few complications at short-term follow-up.
- 18 June 2024
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 17 (3) , 308-315
Achievement of the patient acceptable symptom state following total shoulder arthroplasty with nonspherical humeral head and inlay glenoid
Background: Total shoulder arthroplasty (TSA) with a nonspherical humeral head component and inlay glenoid is a bone preserving treatment for glenohumeral arthritis. This study aims to describe minimum two year patient reported outcomes, patient acceptable symptomatic state (PASS) achievement, and complications following TSA with this prosthesis. Methods: A retrospective review of patients undergoing TSA with nonspherical humeral head and inlay glenoid was performed. Outcomes included Single Assessment Numeric Evaluation (SANE) scores, American Shoulder and Elbow Surgeons (ASES) scores, and complications. SANE and ASES scores were compared to established PASS threshold values to determine PASS achievement. Results: 56 TSA in 53 patients were identified. The mean age was 64.5 years, 64% were male, and mean follow-up was 29.2 ± 4.9 months (24.0–42.8). Two complications (3.6%) were observed: one subscapularis tear requiring revision to reverse TSA and one traumatic minimally displaced greater tuberosity fracture successfully treated nonoperatively. The mean SANE score was 84.3 ± 16.9 (40–100) and 77% of patients surpassed the PASS threshold of 75.5. The mean ASES score was 85.3 ± 15.7 (40–100) and 77% of patients surpassed the PASS threshold of 76. Discussion: Patients undergoing TSA with a nonspherical humeral head and inlay glenoid demonstrated high PASS achievement rates and few complications at short-term follow-up.
- Open Access
- 1 December 2023
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 26 (4) , 380-389
Anatomic total shoulder arthroplasty with a nonspherical humeral head and inlay glenoid: 90-day complication profile in the inpatient versus outpatient setting
Background: Total shoulder arthroplasty (TSA) with a nonspherical humeral head component and inlay glenoid is a successful bone-preserving treatment for glenohumeral arthritis. This study aimed to describe the 90-day complication profile of TSA with this prosthesis and compare major and minor complication and readmission rates between inpatient- and outpatient-procedure patients.Methods: A retrospective review was performed of a consecutive cohort of patients undergoing TSA with a nonspherical humeral head and inlay glenoid in the inpatient and outpatient settings by a single surgeon between 2017 and 2022. Age, sex, body mass index, American Society of Anesthesiologists (ASA) score, Charlson Comorbidity Index (CCI), and 90-day complication and readmission rates were compared between inpatient and outpatient groups.Results: One hundred eighteen TSAs in 111 patients were identified. Mean age was 64.9 years (range, 39–90) and 65% of patients were male. Ninety-four (80%) and 24 (20%) patients underwent outpatient and inpatient procedures, respectively. Four complications (3.4%) were recorded: axillary nerve stretch injury, isolated ipsilateral arm deep venous thrombosis (DVT), ipsilateral arm DVT with pulmonary embolism requiring readmission, and gastrointestinal bleed requiring readmission. There were no reoperations or other complications. Outpatients were younger with lower ASA and CCI scores than inpatients; however, there was no difference in complications (1/24 vs. 3/94, P=1.00) or readmissions (1/24 vs. 1/94, P=0.37) between these two groups.Conclusions: TSA with a nonspherical humeral head and inlay glenoid can be performed safely in both inpatient and outpatient settings. Rates of early complications and readmissions were low with no difference according to surgical setting.Level of evidence: IV.
- 1 December 2023
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 26 (4) , 380-389
Open AccessAnatomic total shoulder arthroplasty with a nonspherical humeral head and inlay glenoid: 90-day complication profile in the inpatient versus outpatient setting
Background: Total shoulder arthroplasty (TSA) with a nonspherical humeral head component and inlay glenoid is a successful bone-preserving treatment for glenohumeral arthritis. This study aimed to describe the 90-day complication profile of TSA with this prosthesis and compare major and minor complication and readmission rates between inpatient- and outpatient-procedure patients.Methods: A retrospective review was performed of a consecutive cohort of patients undergoing TSA with a nonspherical humeral head and inlay glenoid in the inpatient and outpatient settings by a single surgeon between 2017 and 2022. Age, sex, body mass index, American Society of Anesthesiologists (ASA) score, Charlson Comorbidity Index (CCI), and 90-day complication and readmission rates were compared between inpatient and outpatient groups.Results: One hundred eighteen TSAs in 111 patients were identified. Mean age was 64.9 years (range, 39–90) and 65% of patients were male. Ninety-four (80%) and 24 (20%) patients underwent outpatient and inpatient procedures, respectively. Four complications (3.4%) were recorded: axillary nerve stretch injury, isolated ipsilateral arm deep venous thrombosis (DVT), ipsilateral arm DVT with pulmonary embolism requiring readmission, and gastrointestinal bleed requiring readmission. There were no reoperations or other complications. Outpatients were younger with lower ASA and CCI scores than inpatients; however, there was no difference in complications (1/24 vs. 3/94, P=1.00) or readmissions (1/24 vs. 1/94, P=0.37) between these two groups.Conclusions: TSA with a nonspherical humeral head and inlay glenoid can be performed safely in both inpatient and outpatient settings. Rates of early complications and readmissions were low with no difference according to surgical setting.Level of evidence: IV.
- 1 October 2021
- Published by Georg Thieme Verlag KG in Journal of Wrist Surgery
- Vol. 11 (02) , 154-160
CT Scan versus Saline Load Test for Detection of Traumatic Wrist Arthrotomy
Background Traumatic arthrotomy of the wrist is most commonly detected using the saline load test (SLT); however, little data exists on the effectiveness of the SLT to this specific joint. The use of computed tomography (CT) scan has been validated as an alternative method to detect traumatic arthrotomy of the knee, as the presence of intra-articular air can be seen when there is violation of the joint capsule. Question/Purpose The purpose of this study was to determine the ability of CT scan to identify arthrotomy of the wrist capsule and compare the diagnostic performance of CT versus traditional SLT. Materials and Methods Ten fresh frozen cadavers which had undergone transhumeral amputation were initially used in this study. A baseline CT scan was performed to ensure no intra-articular air existed prior to intervention. After baseline CT, an arthrotomy was created at the 6R radiocarpal portal site. The wrists then underwent a postarthrotomy CT to identify the presence or absence of intra-articular air. Following CT, the wrists were subjected to the SLT to detect the presence of extravasation from the arthrotomy. Results Nine cadavers were included following baseline CT scan. Following arthrotomy, intra-articular air was visualized in eight of the nine cadavers in the postarthrotomy CT scan. Air was seen in the radiocarpal joint in eight of the nine wrists; midcarpal joint in seven of the nine wrists; and distal radioulnar joint in six of the nine wrists. All wrists (nine of the nine) demonstrated extravasation during the SLT. The mean volume of extravasation occurred at 3.7 mL (standard deviation = 2.6 mL), with a range of 1 to 7 mL. Conclusion CT scan correctly identified eight of the nine simulated traumatic arthrotomies. Injection of 7 mL during the SLT was necessary to identify 100% of the arthrotomies. Clinical Relevance CT scan is a sensitive modality for detection of traumatic arthrotomy of the wrist in a cadaveric model.
- 1 October 2021
- Published by Georg Thieme Verlag KG in Journal of Wrist Surgery
- Vol. 11 (02) , 154-160
CT Scan versus Saline Load Test for Detection of Traumatic Wrist Arthrotomy
Background Traumatic arthrotomy of the wrist is most commonly detected using the saline load test (SLT); however, little data exists on the effectiveness of the SLT to this specific joint. The use of computed tomography (CT) scan has been validated as an alternative method to detect traumatic arthrotomy of the knee, as the presence of intra-articular air can be seen when there is violation of the joint capsule. Question/Purpose The purpose of this study was to determine the ability of CT scan to identify arthrotomy of the wrist capsule and compare the diagnostic performance of CT versus traditional SLT. Materials and Methods Ten fresh frozen cadavers which had undergone transhumeral amputation were initially used in this study. A baseline CT scan was performed to ensure no intra-articular air existed prior to intervention. After baseline CT, an arthrotomy was created at the 6R radiocarpal portal site. The wrists then underwent a postarthrotomy CT to identify the presence or absence of intra-articular air. Following CT, the wrists were subjected to the SLT to detect the presence of extravasation from the arthrotomy. Results Nine cadavers were included following baseline CT scan. Following arthrotomy, intra-articular air was visualized in eight of the nine cadavers in the postarthrotomy CT scan. Air was seen in the radiocarpal joint in eight of the nine wrists; midcarpal joint in seven of the nine wrists; and distal radioulnar joint in six of the nine wrists. All wrists (nine of the nine) demonstrated extravasation during the SLT. The mean volume of extravasation occurred at 3.7 mL (standard deviation = 2.6 mL), with a range of 1 to 7 mL. Conclusion CT scan correctly identified eight of the nine simulated traumatic arthrotomies. Injection of 7 mL during the SLT was necessary to identify 100% of the arthrotomies. Clinical Relevance CT scan is a sensitive modality for detection of traumatic arthrotomy of the wrist in a cadaveric model.